• Title/Summary/Keyword: SIMPLE method

Search Result 13,709, Processing Time 0.039 seconds

Application of Simple Method of Vibration Analysis to the Simply Supported Sandwich Panels with Point Mass/Masses (첨가된 질량이 있는 단순지지된 샌드위치 패널에 대한 간편한 진동해석의 적용)

  • Lee, Jung-ho;Kim, Seong-Hwan;Jung, Kyoung-il;Lee, Bong-Hak
    • Journal of Industrial Technology
    • /
    • v.16
    • /
    • pp.139-145
    • /
    • 1996
  • Many of the bridge systems, including the girders and cross-beams, and concrete decks behave as the special othotropic plates. A method of calculating the natural frequency corresponding to the first mode of vibration of beam and tower structures with irregular cross-sections was developed and reported by D. H. Kim in 1974. Since 1989, The author has extended this method to Vibration analysis of two dimensional problems including composite laminates, and has reported at several conferenes. Frequently, the bridge floor panels are supported by girders and cross beams. Such panels as well as some of the building floor panels can be assumed as simple supported special orthotropic plates. In this paper, the result of application of simple method of vibration analysis developed by D. H. Kim, to the simply supported sandwich panels with point Mass/Masses is presented.

  • PDF

Improved Hysteresis Current Control Regulator for High-efficiency Switching (고효율 스위칭을 위한 개선된 히스테리시스 전류제어기)

  • Hong, Sun-Ki;Park, Jin-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.11
    • /
    • pp.1606-1610
    • /
    • 2012
  • Hysteresis current regulator has been used widely because of its simple principle and structure. However, when the current band width is too narrow or the applied voltage is relatively too high, the switching frequency may increase abruptly and it generates a large amount of heat. Thus, this study will suggest a better and simple method to reduce the switching frequency. For single phase current control, the proposed hysteresis current control is executed by adding 0 mode state and comparing the slope of the current reference. This simple method decreases the generated switching frequency and significantly reduces the generated heat. This proposed method was proved with simulations and experiments comparing with the classical hysteresis current control method.

A Simple Stable Method in Real-time Lane Tracking of Broken Lanes

  • Xu, Sudan;Chi, Yaohuan;Kim, Kwon;Lee, Chang-Woo
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2007.10a
    • /
    • pp.229-230
    • /
    • 2007
  • Lane detection is one of the major components of traffic intelligence. It is impossible to recognize lanes as human do in all kinds of special situations; however, we can try to solve special problems with special methods. In this paper we propose a simple method using color segmentation, the Probabilistic Hough Transform (PHT), and the Least-Square in real-time lane tracking. Vehicles in neighborhood can be eliminated with one simple threshold in segmentation. Meanwhile, broken shape lanes in different road conditions can be successfully detected using the combination of PHT and Least-Square method. Eventually, this method is tested with groups of static images downloaded from internet and video sequences shot randomly on some highways. Satisfactory results are received.

  • PDF

A Simple Method for Cat Bone Marrow-derived Mesenchymal Stem Cell Harvesting

  • Jin, Guang-Zhen;Lee, Young-Soo;Choi, Eu-Gene;Cho, Kyu-Woan;Kong, Il-Keun
    • Journal of Embryo Transfer
    • /
    • v.23 no.2
    • /
    • pp.127-131
    • /
    • 2008
  • Bone marrow (BM) cell harvesting is a crucial element in the isolation of mesenchymal stem cells (MSCs). A simple method for harvesting cat BM cells is described. The results show that a large number of BM cells can rapidly be harvested from the cat by this simple procedure. MSCs prepared by density-gradient method were spindle-shaped morphology with bipolar or polygonal cell bodies and strongly positive for CD9 and CD44 and negative for CD18 and CD45-like. They were capable of differentiation to adipocytic and osteocytic phenotypes when exposed to appropriate induction media. The advantages of this method are its rapidity, simplicity, low invasiveness, and low donor attrition and good outcome.

Experiment of a Simple Feed-forward Active Control Method for the Shock Response of a Flexible Beam and Performance Analysis (유연빔의 충격응답에 대한 단순 피드포워드 능동제어 실험 및 성능분석)

  • Pyo, Sang-Ho;Shin, Ki-Hong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.634-639
    • /
    • 2006
  • Active control method is applied to a flexible beam excited by a shock impulse in order to reduce the residual vibrations after the shock event. It is assumed that the shock input can be measured and is always occurred on the same point of the beam. If the system is well identified and the corresponding inverse system is designed reliably, it has shown that a very simple feed-forward active control method may be applied to suppress the residual vibrations without using error sensors and adaptive algorithm. Both numerical simulations and experimental results show a promising possibility of applying to a practical problem. Also, the performance of the method is examined by considering various practical aspects : shock duration, shock magnitude, and control point.

  • PDF

Simple Protection Method against Deregistration Attack in SIP (SIP 등록취소 공격에 대한 단순한 방어 기법)

  • Kwon, Kyung Hee
    • Journal of the Semiconductor & Display Technology
    • /
    • v.15 no.4
    • /
    • pp.92-96
    • /
    • 2016
  • Although deregistration attack is caused by simple spoofing the REGISTER message of a legitimate SIP UA, its impact is serious. The root cause of this attack is based on the fact that RFC 3261 allows the UA to remove the binding from the Location Server. In this paper, we propose a simple protection method to allow Registrar or Location Server just to ignore deregistration messages. We also show that this method works well by analyzing the process of registration and deregistration. Without any additional overhead such as an encryption or authentication, this method is able to establish a secure SIP environment efficiently protecting against the deregistration attack.

A Simple Feed-forward Active Control Method for the Shock Response of a Flexible Beam: Experiments and Its Performance Analysis (유연보의 충격응답에 대한 단순 피드포워드 능동제어 실험 및 성능분석)

  • Pyo, Sang-Ho;Shin, Ki-Hong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.6 s.111
    • /
    • pp.651-657
    • /
    • 2006
  • Active control method is applied to a flexible beam excited by a shock impulse in order to reduce the residual vibrations after the shock event. It is assumed that the shock input can be measured and is always occurred on the same point of the beam. If the system is well identified and the corresponding inverse system is designed reliably, it has shown that a very simple feed-forward active control method may be applied to suppress the residual vibrations without using error sensors and adaptive algorithm. Both numerical simulations and experimental results show a promising Possibility of applying to a practical problem. Also, the performance of the method is examined by considering various practical aspects : shock duration, shock magnitude, and control point.

Simple Calculation Method as a Supplementary Radiation Safety Assessment for Facility with Radiation Generator

  • Kim, Sang-Tae
    • International Journal of Contents
    • /
    • v.14 no.4
    • /
    • pp.65-69
    • /
    • 2018
  • The objective of this study was to conduct a radiation shielding analysis for the facility equipped with radiation generator. The analysis was carried out in two aspects. First, from the aspect of the effect caused by primary and leakage radiation. Second, effect of scattered radiation was evaluated by applying a simple calculation method based on a scattering rate concept since effect of scattered radiation is significantly important at maze entrance of the radiation facility. The calculated results obtained using the simple method were compared to the results calculated using Geant4 code and the measured values. The results calculated by the suggested method indicate that slight error exists in a radiation shielding analysis done at the maze entrance comparing to other two results, while the results evaluated at the outside of the maze entrance door are relatively consistent with other values.

Analysis of loop duct system by extended T-method (확장 T-method에 의한 환상식 덕트시스템 해석)

  • 이승철;문종선;이재헌
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.4
    • /
    • pp.389-397
    • /
    • 1998
  • A loop duct system is often found in a VAV-HVAC(variable air volume heating, ventilating and air conditioning) design. It is known that the simple T-method is not be applicable to the loop duct system and cannot be used to calculate the flow rate and the pressure drop at each duct section of the loop duct system. In this paper, the extended T-method has been developed and it is found to be applicable to the loop duct system to which the simple T-method cannot be applied. The validity of the extended T-method has been verified by using to solve for a simple, ideal loop duct system for which there exists analytical solution. In addition, the extended T-method is employed to compute the loop duct system of a real building with an area of 380$m^2$. The results show that the computed flow rate at the exit differs from the designed flow rate by a range of -13.6~43.5 %. Consequently, three design factors must be adjusted in order that the flow rate may be balanced. These include the duct sizes, in terms of their lengths and diameters, the sub-duct locations and the positioning of damper which is found upstream of the exit duct.

  • PDF

Formulation and Verification on Ritz Method for In-Cabinet Response Spectrum (캐비닛내부응답스펙트럼 산정을 위한 리츠방법의 정식화 및 단순예제를 통한 검증)

  • Kim, Ki Hyun;Hong, Kee-Jeung;Cho, Sung Gook;Park, Woong Ki
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.23 no.5
    • /
    • pp.279-288
    • /
    • 2019
  • Safety-related cabinets and their electrical parts, such as relays and switches in nuclear power plants, should maintain continuous functioning, as well as structural safety according to the nuclear regulatory guidelines. Generally, an electrical part is qualified if its functioning is maintained without abnormality during excitement by motion compatible with the test response spectrum, which is larger than its in-cabinet response spectrum (ICRS). ICRS can be determined by shake-table test or dynamic analysis. Since existing cabinets in use can hardly be stopped and moved, dynamic analysis is preferred over shake-table test in determining ICRS. The simple method, suggested by the Electric Power Research Institute (EPRI) to determine ICRS, yields conservative or non-conservative results from time to time. In order to determine that the ICRS is better than EPRI method in a simple way, Ritz method considering global and local plate behaviors was suggested by Gupta et al. In this paper, the Ritz method is modified in order to consider the rocking and frame behaviors simultaneously, and it is applied to a simple numerical example for verification. ICRS is determined by Ritz method and compared with the results by finite element method (FEM). Based on this numerical example, recommendations for using Ritz method are suggested.