• Title/Summary/Keyword: SIM Protocol

Search Result 184, Processing Time 0.026 seconds

A Study of the Temperature Dependency for Photocatalytic VOC Degradation Chamber Test Under UVLED Irradiations (UVLED 광원을 이용한 광촉매 VOC 제거 특성 평가시 온도에 따른 농도 변화에 관한 연구)

  • Moon, Jiyeon;Lee, Kyusang;Kim, Seonmin
    • Korean Chemical Engineering Research
    • /
    • v.53 no.6
    • /
    • pp.755-761
    • /
    • 2015
  • Photocatalytic VOCs removal test in gas phase is generally performed by placing the light source on the outside due to maintaining a constant temperature inside the test chamber. The distance between light source and photocatalysts is importantin the VOC degradation test since the intensity of light is rapidly decreased as the distance farther. Especially, for the choice of light source as UVLED, this issue is more critical because UVLED light source emits lots of heat and it is hard to measure the exact concentration of VOCs due to changed temperature in the test chamber. In this study, we modified VOC removal test chamber base on the protocol of air cleaner test and evaluated the efficiency of photocatalystunder UVLED irradiation. Photocatalystsof two different samples (commercial $TiO_2$ and the synthesized vanadium doped $TiO_2$) weretested for the p-xylene degradation in the closed chamber system and compared with each other in order to exclude any experimental uncertainties. During the VOC removal test, VOC concentrations were monitored and corrected at regular time intervals because the temperature in the chamber increases ${\sim}20^{\circ}C$ due tothe heat of UVLED. The results showed that theconversion ratio of p-xylene has 40~43% difference before and after the temperature correction. Based on those results, we conclude that the VOC concentration correction must be required for the VOC removal test in a closed chamber system under UVLED light source and obtained the corrected efficiencies of various photocatlysts.

Development of the Power Monitoring System for the Planetary Geared Motor using Hall Effect Sensor (홀 이펙트 센서를 이용한 유성기어 감속기모터의 동력 모니터링 시스템 개발)

  • Jang, In-Hun;Sim, Kwee-Bo;Oh, Se-Hoon
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.14 no.7
    • /
    • pp.914-919
    • /
    • 2004
  • When the motor is rotating, the torque and rpm are varying as the loads or the driving status connecting through reduction units are changing. On the contrary, one can monitor the changes of the loads or the driving status in the manner of measuring motor torque and rpm. There is a torque measuring method using the strain gauge and bridge circuit. But, because this is the contact method, it has the life time which is dependent on rotating velocity and used time. So this system demands on replacement of some Parts or whole system itself for maintenance. And this system is also relatively big and expensive, requiring preceding annoying process. In this paper, we are going to suppose non-contact method to measure torque and rpm using the Hall effects sensor For this we have made the planetary geared reduction motor with Hall sensors and with the monitoring system. The monitoring system displays the sensing data(torque, rpm) and calculated data( power) and also has the network capability with Bluetooth protocol. Our solution is much more inexpensive ;md simple method to measure torque and rpm than before.

The Design and Implementation of Automotive Smart-key System Using general-purpose RFID (교통카드와 같은 범용 RFID를 활용한 자동차용 스마트키 시스템 설계 및 구현)

  • Lee, Yun-Sub;Kim, Kyeong-Seob;Yun, Jeong-Hee;Choi, Sang-Bang
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.46 no.4
    • /
    • pp.42-50
    • /
    • 2009
  • Ubiquitous computing technology is widely used in not only our everyday lives but also in education, medical care, military, environment and administration. RFID system, the basis of ubiquitous, is in the spotlight which can be an alternative solution of a bar code recognition system and magnetic system as they basically have practicality and security issues. An electronic authentication named smart-key system is recently concerned by an alternative solution of the security unit for an automobile. RFID system which has a general purpose is also in the limelight by an application technology. In this paper we designed vehicle smart key system with general-propose RFID system that is already in use. First, we designed control unit and RFID card reader for vehicle smart key system. Then we propose an algorithm and prove that the vehicle key system is controllable by showing the result of implementing and testing, after installing. Also security level is enlarged by proposing a authentication protocol between RFID reader and control unit.

Review on asbestos analysis (석면 분석방법에 대한 고찰)

  • Ham, Seung hon;Hwang, Sung Ho;Yoon, Chungsik;Park, Donguk
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.19 no.3
    • /
    • pp.213-232
    • /
    • 2009
  • This document was prepared to review and summarize the analytical methods for airborne and bulk asbestos. Basic principles, shortcomings and advantages for asbestos analytical instruments using phase contrast microscopy(PCM), polarized light microscopy(PLM), X-ray diffractometer (XRD), transmission electron microscopy(TEM), scanning electron microscopy(SEM) were reviewed. Both PCM and PLM are principal instrument for airborne and bulk asbestos analysis, respectively. If needed, analytical electron microscopy is employed to confirm asbestos identification. PCM is used originally for workplace airborne asbestos fiber and its application has been expanded to measure airborne fiber. Shortcoming of PCM is that it cannot differentiate true asbestos from non asbestos fiber form and its low resolution limit ($0.2{\sim}0.25{\mu}m$). The measurement of airborne asbestos fiber can be performed by EPA's Asbestos Hazard Emergency Response Act (AHERA) method, World Health Organization (WHO) method, International Standard Organization (ISO) 10312 method, Japan's Environmental Asbestos Monitoring method, and Standard method of Indoor Air Quality of Korea. The measurement of airborne asbestos fiber in workplace can be performed by National Institute for Occupational Safety and Health (NIOSH) 7400 method, NIOSH 7402 method, Occupational Safety and Health Administration (OSHA) ID-160 method, UK's Health and Safety Executive(HSE) Methods for the determination of hazardous substances (MDHS) 39/4 method and Korea Occupational Safety and Health Agency (KOSHA) CODE-A-1-2004 method of Korea. To analyze the bulk asbestos, stereo microscope (SM) and PLM is required by EPA -600/R-93/116 method. Most bulk asbestos can be identified by SM and PLM but one limitation of PLM is that it can not see very thin fiber (i.e., < $0.25{\mu}m$). Bulk asbestos analytical methods, including EPA-600/M4-82-020, EPA-600/R-93/116, OSHA ID-191, Laboratory approval program of New York were reviewed. Also, analytical methods for asbestos in soil, dust, water were briefly discussed. Analytical electron microscope, a transmission electron microscope equipped with selected area electron diffraction (SAED) and energy dispersive X-ray analyser(EDXA), has been known to be better to identify asbestiform than scanning electron microscope(SEM). Though there is no standard SEM procedures, SEM is known to be more suitable to analyze long, thin fiber and more cost-effective. Field emission scanning electron microscope (FE-SEM) imaging protocol was developed to identify asbestos fiber. Although many asbestos analytical methods are available, there is no method that can be applied to all type of samples. In order to detect asbestos with confidence, all advantages and disadvantages of each instrument and method for given sample should be considered.

A Study on change from an RTU-based substation to IEC 6 1850-based SA substation (RTU 기반 변전소의 IEC 61850 기반 SA 변전소로의 전환에 대한 실증 연구)

  • Yuk, Sim-Bok;Lee, Sung-Hwan;Kim, Chong-il
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.11 no.4
    • /
    • pp.436-444
    • /
    • 2018
  • Currently, the new substation automation uses the international standard IEC 61850 communication protocol. KEPCO is also constructing a new substation based on IEC 61850 from 2013 through the pilot application and research and development starting from 2007. However, there are few cases where existing substations(Transformer, T/L GIS, D/L GIS, etc.) have been used, and RTU based substations operating systems have been changed to SA substations based on IEC 61850. Therefore, the introduction of IEC 61850 in existing substation facilities has the advantage of enhancing the substantiality of the substation by reusing existing facilities, improving the interoperability with the latest substations introduced, and converting existing substations into systems suitable for unmanned operation. In this paper, we introduce a case of changing the existing RTU based substation operation system to digital substation using IEC 61850 field information processor, Ethernet switch and SA operation system. Also, IEC 61850 client authentication program and Wireshark, which is a packet analysis tool, verify IEC 61850 conformance and its feasibility.

Literature Review Nursing Intervention for Developmental Support on Preterm Infants (미숙아의 발달지지를 위한 간호중재에 관한 문헌연구)

  • Kim, Tae-Im;Sim, Mi-Kyung
    • Korean Parent-Child Health Journal
    • /
    • v.4 no.1
    • /
    • pp.35-55
    • /
    • 2001
  • Recently attention has been focused on the effects of early intervention, or its lack, on both normal and preterm infants. Particularly numerous studies suggest that premature infants are not necessarily understimulated but instead are subjected to inappropriate stimulation. Developmental support and sensory stimulation have become clinical opportunities in which nursing practice can impact on the neurobehavioral outcome of premature infants. Developmental care has been widely accepted and implemented in neonatal intensive care units across the country. Increasingly, attention and concern in caring for low-birth-weight infants and premature infants has led clinicians in the field to explore the effects of a complex of interventions designed to create and maintain a developmentally supportive environment; to provide age-appropriate sensory input; and to protect the infant from inappropriate, excessive and stressful stimulation. The components of developmental care include modifications of the macro-environment to reduce NICU light and sound levels, care clustering, nonnutritive sucking, and containment strategies, such as flexed positioning or swaddling. Sensory stimulation of the premature infants is presented to standardize the modification of a developmental intervention based on physiologic and behavioral cues. The most appropriate type of stimuli are those that are sensitive to infant cues. Evaluation of infant physiological and behavioral responds to specific intervention stimuli may help to identify more appropriate interventions based on infants' cues. A critical question confronting the clinician is that of determining when the evidence supporting a change in practice is sufficient to justify making that change. There are acknowledged limitations in the current studies. Many of the studies examined had small sample sizes; used nonprobability sampling; and used a phase lag design, which introduces the possibility of threats to internal validity and limits the generalizability of the results. Although many issues regarding the effects of developmental interventions remain unresolved, the available research base documents significant benefits of developmental care for LBW infants in consistent outcomes, without significant adverse effects. Particularly, although the individual studies vary somewhat in the definition of specific outcomes measured, instrumentation used, time and method of data collection, and preparaion of the care providers, in all studies, infants receiving the full protocol of individualized developmentally supportive care had improvements in some aspect of four areas of infant functioning: level of respiratory or oxygen support, the establishment of oral feeding; length of hospital stay, and infant behavioral regulation. In summary, based on the available literature, individualized developmental intervention should be incorporated into standard practice in neonatal intensive care. And this implementation needs to be coupled with ongoing research to evaluate the impact of an individualized developmental care programs on the short- and long-tenn health outcomes of LBW infants.

  • PDF

Short-term Hypothermic Preservation of CHO Cells Using Serum-Free Media (무혈청 배지를 이용한 CHO 세포의 단기 저온보존)

  • Byoun, Soon-Hwi;Park, Hong-Woo;Choe, Tae-Boo
    • KSBB Journal
    • /
    • v.21 no.4
    • /
    • pp.306-311
    • /
    • 2006
  • Cell preservation is indispensable in animal cell culture process and should be established according to the cell characteristics. In this study, we experimented hypothermic preservation of CHO cells that is widely used in pharmaceutical industry to produce therapeutic proteins and established a stable method of preservation. The highest viability of CHO cells was obtained when the cells were preserved using rolling tube, which means the cells should be suspended to avoid the cell lumping during the preservation. Also, we obtained superior preservation result under the anaerobic condition. To evaluate the serum-free media as a preservation solution, we investigated cell growth after hypothermic preservation using serum-free media. High cell viability and normal cell growth was observed during 10 days using serum-free media. Moreover, we found that more effective preservation when ${\alpha}$-tocopherol and retinoic acid is added to media as an additive. In the case of 1 liter large scale hypothermic preservation using established protocol, cell viability and growth rate was obtained as good as small scale one. This study is considered to be helpful for hypothermic preservation of CHO cells and large scale hypothermic preservation may be available through the further studies.

Effect of cultivar and ascorbic acid on in vitro shoot regeneration and development of bombardment-mediated plastid transformation of tomato (Lycopersicon esculentum) (토마토 재분화 효율 향상 및 엽록체 형질전환 조건)

  • Roh, Kyung-Hee;Lee, Ki-Jong;Park, Jong-Sug;Kim, Jong-Bum;Lee, Seung-Bum;Suh, Seok-Cheol
    • Journal of Plant Biotechnology
    • /
    • v.37 no.1
    • /
    • pp.77-83
    • /
    • 2010
  • Eighteen cultivars of tomato were tested for their regeneration response. Lycopersicon esculentum cv. 2001-58 showed a very high frequency of regeneration (93%). We evaluated the effect of two compounds with known antioxidant activity (ascorbic acid and cystein). The use of ascorbic acid ($200\;-\;300\;{\mu}M/L$) has a positive effect on shoot regeneration. To develope a system for plastid transformation in tomato via homologous recombination, we constructed the tomato plastid expression vector (pKRT22-AG) harboring 2.2 kb flanking sequences cloned from intact plastid genome and gfp gene. To investigate the factors affecting the delivery system of the pKRT22-AG into chloroplast using bombardment, We assessed the optimal DNA concentration, gold particle volume and target distance. Expression of the GFP protein was observed within chloroplast on protoplast of cotyledon explant by confocal laser scanning microscopy, which indicates that the protocol developed in this study be useful for the production of plastid transgenic plants in tomato.

A Study on Clinical Response to Controlled Ovarian Hyperstimulation of In Vitro Fertilization and Embryo Transfer According to the Size of Baseline Ovarian Cyst (체외수정시술을 위한 과배란유도시 난소낭종의 크기에 따른 임상적 반응에 대한 연구)

  • Lee, Yong-Soek;Jung, Byeong-Jun;Lee, Sang-Hoon;Hur, Min
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.26 no.3
    • /
    • pp.355-362
    • /
    • 1999
  • Objective: This study was performed to compare the clinical response to controlled ovarian hyperstimulation (COH) of in vitro fertilization and embryo transfer (IVF-ET) according to the size of baseline ovarian cyst. Method: From February 1992 to March 1999, a retrospective analysis was done of 272 cases who underwent COH using mid-luteal phase long protocol of gonadotropin-releasing hormone agonist (GnRH-a) for IVF-ET. These cases were divided into four group; group 1 (n=63) had cysts with mean diameters between 20.0 and 29.0 mm on their baseline ultrasound on cycle day 3, group 2 (n=57, $30.0{\sim}49.0mm$), group 3 (n=68, >50.0 mm) and control group (n=84). Cases were excluded according to the following criteria; pure male factor infertility, the presence of only one ovary, high CA-125 level and previous endometriosis. Results: There were no statistically significant differences between cases with baseline ovarian cyst <50.0 mm in diameter and control group in any of the parameters. However, cases with baseline ovarian cyst>50.0 mm in mean diameter needed more amount of human menopausal gonadotropin (hMG), showed significantly lower estradiol ($E_2$) level, the number of follicle >15.0 mm on the day of human chorionic gonadotropin (hCG) administration, the number of oocytes retrieved, the number of mature oocytes, and pregnancy rate compared with control group. Conclusion: This study suggests that cases with baseline ovarian cyst <50.0 mm in diameter do not adversely impact on IVF-ET outcome. However, cases with baseline ovarian cyst >50.0 mm in diameter had adverse effects on various parameters. Therefore, to improve the outcome of IVF-ET in these cases, ovarian cyst aspiration prior to initiating COH may be required.

  • PDF

A STUDY ON THE BONE FORMATION OF GRAFT MATERIAL CONTAINING DEMINERALIZED BONE MATRIX WITH A SIMULTANEOUS INSTALLATION OF IMPLANT (임프란트 식립시 이식된 탈회골기질을 함유한 이식재의 골형성에 대한 연구)

  • Kim, Yeo-Gab;Yoon, Byung-Wook;Ryu, Dong-Mok;Lee, Baek-Soo;Oh, Jung-Hwan;Kwon, Yong-Dae
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.31 no.6
    • /
    • pp.481-491
    • /
    • 2005
  • Purpose: The aim of the present study is to evaluate the effect of autogenous bone and allograft material coverd with a bioresorbable membrane on bone regeneration after a simultaneous installation of implant. Materials and methods: Twelve healthy rabbits, weighing about $3{\sim}4$ kg, were used in this experiment. Following impalnt(with 3.25 mm diameter and 8 mm length) site preparation by surgical protocol of $Oraltronics^{(R)}$, artificial bony defect, 5mm sized in height and depth, was created on femoral condyle using trephine drill(with 5 mm diameter and 5 mm length). Then implant was inserted. In the experimental group A, the bony defect was filled with autogenous particulated bone and coverd with $Lyoplant^{(R)}$ resorbable membrane. In the experimental group B, the bony defect was filled with allograft material(Orthoblast $II^{(R)}$) containing demineralized bone matrix and covered with $Lyoplant^{(R)}$. In the control group, without any graft materials, the bony defect was covered with $Lyoplant^{(R)}$. The experimental group A and B were divided into each 9 cases and control group into 3 cases. The experimental animals were sacrificed at 3, 6 and 8 weeks after surgery and block specimens were obtained. With histologic and histomorphometric analysis, we observed the histologic changes of the cells and bone formation after H-E staining and then, measured BIC and bone density with KAPPA Image $Base^{(R)}$ system. Results: As a result of this experiment, bone formation and active remodeling process were examined in all experimental groups and the control. But, the ability of bone formation of the experimental group A was somewhat better than any other groups. Especially bone to-implant contact fraction ranged from 12.7% to 43.45% in the autogenous bone group and from 9.02% to 29.83% in DBM group, at 3 and 8 weeks. But, bone density ranged from 15.67% to 23.17% in the autogenous bone group and from 25.95% to 46.06% in DBM group at 3 and 6 weeks, respectively. Although the bone density of DBM group was better than that of autogenous bone group at 3 and 6weeks, the latter was better than the former at 8 weeks, 54.3% and 45.1%, respectively. Therefore these results showed that DBM enhanced the density of newly formed bone at least initially.