• Title/Summary/Keyword: SI traceability

Search Result 17, Processing Time 0.019 seconds

Development of Certified Reference Materials for Specific Surface Area (비표면적 인증표준물질 개발)

  • Choi, Byung Il;Kim, Jong Chul;Kim, Taeyoung;Nham, Hyunsoo;Kwon, Su Yong
    • Analytical Science and Technology
    • /
    • v.18 no.1
    • /
    • pp.74-84
    • /
    • 2005
  • Understandings of adsorption characteristic of interface are very important in several advanced materials processes, related to NT and BT technology. Volumetric gas adsorption method, suitable for absolute measurements, is regarded as the standardized measurement technique for specific surface area. In order to verify the reliability of commercial equipments, certified reference materials (called CRM) of specific surface area are developed and evaluated its uncertainty factors by standard equipment which has traceability to SI units. Specific surface areas of developed materials are $10.72{\pm}0.46m^2g^{-1}$ for silicon nitride powders and $149.50{\pm}3.44m^2g^{-1}$ for alumina. These disseminations of CRMs would result in improved reliability chains in industrial processes, and lead eventually to contribution to productivity improvement, quality management, safety evaluation, and possibly to new material development.

A case study on the RFID technology and the necessity of development for smart management of railway vehicle (철도차량 스마트 운영관리를 위한 RFID 기술현황 및 개발 필요성)

  • Lee, Sang-Hak;Cha, Jung-Hoon;Seo, Bong-Jin;Park, Chan-Young;Ha, Byoung-Yong;Lee, Eun-Mi;Kim, Chang-Hyun;Lee, Hak-Yong;Kim, Jae-Sik;Kim, Kwan-Soo;Song, Jeong-Hun;Park, Se-Young;Hwang, Si-Won;Ryeu, Jin-Kyung
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.9 no.2
    • /
    • pp.219-230
    • /
    • 2014
  • There are many economical and industrial as well as social demands enabling smart management of railway vehicle including parts management by introducing RFID system in railway vehicle. In this paper, overseas researches and developments which use cases of RFID were investigated and analyzed. In this process, cases of various industries adopting RFID technology as well as cases of railway part were investigated. RFID system is used mainly for railway vehicle position detection and identification of vehicles in the field of railway. Also there are cases of application on traceability management of railway vehicle parts. The system in which RFID technology can be applied to railway parts management and traceability management is necessary for smart management of domestic railway vehicle.

A Parentage Test using Indel, Microsatellite Markers and Genotypes of MC1R in the Jeju Black Cattle Population (제주 흑우 집단에서 Indel, Microsatellite 마커와 MC1R 유전자형을 이용한 친자 확인)

  • Han, Sang Hyun;Cho, Sang-Rae;Cho, In-Cheol;Cho, Won-Mo;Kim, Sang-Geum;Yang, Sung-Nyun;Kang, Yong-Jun;Park, Yong-Sang;Kim, Young-Hoon;Park, Se-Phil;Kim, Eun-Young;Lee, Sung-Soo;Ko, Moon-Suck
    • Journal of Embryo Transfer
    • /
    • v.28 no.3
    • /
    • pp.207-213
    • /
    • 2013
  • This study was carried out to examine a molecular marker system for parentage test in Jeju Black cattle (JBC). Based on the preliminarily studies, we finally selected for construction of a novel genetic marker system for molecular traceability, identity test, breed certification, and parentage test in JBC and its related industrial populations. The genetic marker system had eight MS markers, five indel markers, and two single nucleotide polymorphisms (SNPs; g.G299T and g.del310G) within MC1R gene which is critical to verify the breed specific genotypes for coat color of JBC differing from those of exotic black cattle breeds such as Holstein and Angus. The results showed lower level of a combined non-exclusion probability for second parent (NE-P2) of $4.1202{\times}10^{-4}$ than those previously recommended by International Society of Animal Genetics (ISAG) of $5.000{\times}10^{-4}$ for parentage, and a combined non-exclusion probability for sib identity (NE-SI) of $2.679{\times}10^{-5}$. Parentage analysis has been successfully identified the JBC offspring in the indigenous population and cattle farms used the certified AI semens for production using the JBC-derived offspring for commercial beef. This combined molecular marker system will be helpful to supply genetic information for parentage test and traceability and to develop the molecular breeding system for improvement of animal productivity in JBC population.

Mass Balance Method for Purity Assessment of Organic Reference Materials: for Thermolabile Materials with LC-UV Method

  • Lee, Joonhee;Kim, Byungjoo
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.11
    • /
    • pp.3275-3279
    • /
    • 2014
  • A mass balance method for purity assessment of thermolabile organic reference materials was established by combining several techniques, including liquid chromatography with UV/VIS detector (LC-UV), Karl-Fischer (K-F) Coulometry, and thermal gravimetric analysis (TGA). This method was applied to three fluoroquinolones like enrofloxacin, norfloxacin and ciprofloxacin. LC-UV was used to analyze structurally related organic impurities based on UV/VIS absorbance spectra obtained in combination with LC separation. For all three organic reference materials, the UV/VIS spectra of the separated impurities were similar to that of the major component of the corresponding materials. This indicates that the impurities are structurally related to the respective reference material sharing common chromophores. Impurities could be quantified by comparing their absorbances at the wavelength of maximum absorbance (${\lambda}_{max}$). The water contents of the reference materials were measured by K-F Coulometry by an oven-drying method. The total inorganic impurities contents were assayed from ash residues in TGA analysis with using air as a reagent gas. The final purities estimated from results of those analytical techniques were assigned as ($99.91{\pm}0.06$), ($97.09{\pm}0.17$) and ($91.85{\pm}0.17$)% (kg/kg) for enrofloxacin, norfloxacin and ciprofloxacin, respectively. The assigned final purities would be applied to the reference materials which will be used as calibrators for the certification of those compounds in matrix CRMs as starting points for the traceability of their certified values to SI units.

Intercomparison of the KAERI Reference Photon and Beta Radiation Measurements (한국원자력연구소 기준 광자 및 베타선장 측정의 국제상호비교)

  • Chang, Si-Yeong;Kim, Bong-Hwan;Kim, Jang-Lyul;McDonald, J.C.;Murphy, M.K.
    • Journal of Radiation Protection and Research
    • /
    • v.21 no.4
    • /
    • pp.255-262
    • /
    • 1996
  • This paper describes the results of intercomparison measurements of KAERI reference photon and beta radiation fields between the KAERI and the PNNL(Pacific Northwest National Laboratory), recently performed at KAERI radiation calibration and dosimetry laboratory on the basis of the ANSI N13.11 criteria for personal dosimeter performance test. Each laboratory used her own radiation detectors or measurement devices traceable to her national primary standard in measuring the exposure rates for photon fields, the absorbed dose rates for beta radiation fields. The agreements in reference radiation measurements between two laboratories were found to be less than ${\pm}2.0%$ for photon fields, ${\pm}1.0%$ for beta radiation fields. Therefore, it could be concluded that KAERI reference radiation fields comply well with the international standard and thus can further serve as a national basis for the researches and developments in radiation protection dosimetry in Korea.

  • PDF

Investigation on the Stability of Uric Acid and its Isotope (1,3-15N2) in Ammonium Hydroxide for the Absolute Quantification of Uric Acid in Human Serum

  • Lee, Sun Young;Kim, Kwonseong;Oh, Han Bin;Hong, Jongki;Kang, Dukjin
    • Mass Spectrometry Letters
    • /
    • v.8 no.3
    • /
    • pp.59-64
    • /
    • 2017
  • In clinical diagnosis, it's well known that the abnormal level of uric acid (UA) in human body is implicated in diverse human diseases, for instance, chronic heart failure, gouty arthritis, diabetes, and so on. As a primary method, an isotope dilution mass spectrometry (IDMS) has been used to obtain the accurate quantity of UA in blood or serum and also develop the certificated reference material (CRM) so as to provide a SI-traceability to clinical laboratories. Due to the low solubility of UA in water, an ammonium hydroxide ($NH_4OH$) has been considered as a promising solvent to increase the solubility of UA that enables the preparation of both UA and its isotope standard solution for next IDMS-based absolute quantification. But, because of using this $NH_4OH$ solvent, it gives rise to the unwanted degradation of UA. In this study, we sought to optimize condition for the stability of UA in $NH_4OH$ solution by varying the mole ratios of UA to $NH_4OH$, followed by ID-LC-MRM analysis. In addition, we also inspected minutely the effect of the storage temperatures. Additionally, we also performed the quantitative analysis of UA in the KRISS serum certificated reference material (CRM, 111-01-02A) with diverse mixing ratios of UA to $NH_4OH$ and then compared those values to its certification value. Based on our experiments, adjusting the mole ratio of 1/2 ($UA/NH_4OH$) with the storage temperature of $-20^{\circ}C$ is an effective way to secure both the solubility and stability of UA in $NH_4OH$ solution for next IDMS-based quantification of UA in serum.

Proficiency Test of Water Flow Rate for Measurement Equivalence Among KOLAS Accredited Laboratories (KOLAS 교정기관의 측정동등성 확립을 위한 물유량 숙련도 시험)

  • Chun, Sejong;Yoon, Byung-Ro;Kim, Soo-Jin
    • Transactions of the KSME C: Technology and Education
    • /
    • v.5 no.2
    • /
    • pp.105-113
    • /
    • 2017
  • KOLAS (KOrea Laboratory Accreditation Scheme) belongs to APLAC (Asia Pacific Laboratory Accreditation Cooperation). KOLAS manages the accreditation scheme for measurement traceability to SI units. As per June 2016, there are 22 KOLAS laboratories for liquid flow metering. Among them, 12 laboratories participated in the proficiency test (PM2015-08) for water flow metering, organized by KASTO (Korea Association of Standards and Testing Organizations). This proficiency test was performed with three kinds of flow ranges ($3.6m^3/h{\sim}12m^3/h$, $40m^3/h{\sim}80m^3/h$, $40m^3/h{\sim}200m^3/h$) considering the CMC (calibration and measurement capability) of the participating laboratories. The purpose of the proficiency test was to find out measurement equivalence of the CMC's between each participating laboratory and the reference testing laboratory (KRISS). The measurement equivalence was tested by the number of equivalence ($E_n$). If ${\mid}E_n{\mid}$ < 1, the measurement equivalence was established. All the participating laboratories passed this proficiency test.