• 제목/요약/키워드: SHEAR STRENGTH

검색결과 5,534건 처리시간 0.032초

강연선과 아일랜드타입 전단키를 이용한 쉴드터널 체결기술 연구 (A Study on Shield Tunnel Assembling System Using a Cable and Island-Type Shear Key)

  • 마상준;이영섭;김동민
    • 한국지반공학회논문집
    • /
    • 제31권3호
    • /
    • pp.17-25
    • /
    • 2015
  • 본 연구에서는 볼트체결을 이용한 쉴드터널 세그먼트의 체결방식의 문제점을 보완하기 위해 새로운 세그먼트 체결기술을 개발하였다. 개발된 체결방식과 볼트체결방식에 대하여 구조검토와 수치해석 기법을 통해 세그먼트에 발생하는 역학적 거동을 평가하였다. 아일랜드타입 전단키는 기존 세그먼트 체결방식의 고인장력 볼트보다 높은 전단강도를 확보하였으며, 강연선에 의한 인장강도의 증대로 세그먼트 전체의 안정성 증가를 기대할 수 있을 것으로 판단된다.

흙-토목섬유 Interface 특성에 관한 연구 (A Study on the Characteristics of the Soil-Geotextile Interface)

  • 고홍석;고남영;홍순영
    • 한국농공학회지
    • /
    • 제33권2호
    • /
    • pp.82-93
    • /
    • 1991
  • The objective of this paper is to show that the soil-geotextile interaction needs to he addressed in addition to the usual tensile and modulus properties when the geotextile is being designed for a specific application. The soil-geotextile interaction can be directly assessed by standard direct shear test. The data presented here show that the shear strength paramaters describing the soil-geotextile interface can he greatly influenced by the type of the geotextile. In this investigation, we examined nine different geotextiles of varying construction and surface textures with two standard soil, under five loading conditions, and compared the shear strength and the frictional resistance with the corresponding values of soil itself The following conclusions were drawned from this study. 1. The shear stress-strain curve shows that there are the residual shear stresses at the soil-geotextile interface. Because of the hydraulic gradient between the soil and the geotextile, the excessive pore water can migrate into the geotextile and among the filaments and dissipate through the soil-geotextile interface. 2. The shear strength of the soil-geotextile interface is affected by the moisture content of the soil. At moisture content lower than the optimum water content of the Proctor compaction test, the shear strength of the soil-geotextile interface is greater. 3. The type and surface roughness of the geotextile have the greatest influence on the interface friction angle between the soil and the geotextile.

  • PDF

Rate of softening and sensitivity for weakly cemented sensitive clays

  • Park, DongSoon
    • Geomechanics and Engineering
    • /
    • 제10권6호
    • /
    • pp.827-836
    • /
    • 2016
  • The rate of softening is an important factor to determine whether the failure occurs along localized shear band or in a more diffused manner. In this paper, strength loss and softening rate effect depending on sensitivity are investigated for weakly cemented clays, for both artificially cemented high plasticity San Francisco Bay Mud and low plasticity Yolo Loam. Destructuration and softening behavior for weakly cemented sensitive clays are demonstrated and discussed through multiple vane shear tests. Artificial sensitive clays are prepared in the laboratory for physical modeling or constitutive modeling using a small amount of cement (2 to 5%) with controlled initial water content and curing period. Through test results, shear band thickness is theoretically computed and the rate of softening is represented as a newly introduced parameter, ${\omega}_{80%}$. Consequently, it is found that the softening rate increases with sensitivity for weakly cemented sensitive clays. Increased softening rate represents faster strength loss to residual state and faster minimizing of shear band thickness. Uncemented clay has very low softening rate to 80% strength drop. Also, it is found that higher brittleness index ($I_b$) relatively shows faster softening rate. The result would be beneficial to study of physical modeling for sensitive clays in that artificially constructed high sensitivity (up to $S_t=23$) clay exhibits faster strain softening, which results in localized shear band failure once it is remolded.

Investigation of the shear behaviour of multi-story reinforced concrete walls with eccentric openings

  • Taleb, Rafik;Bechtoula, Hakim;Sakashita, Masanubo;Bourahla, Noureddine;Kono, Susumu
    • Computers and Concrete
    • /
    • 제10권4호
    • /
    • pp.361-377
    • /
    • 2012
  • Four Reinforced Concrete (RC) single span structural walls having various opening sizes and locations were constructed and tested under lateral reversed cyclic loading at the structural laboratory of Kyoto University. These specimens were scaled to 40% and represented the lower three stories of a six-storied RC building. The main purposes of the experimental tests were to evaluate the shear behavior and to identify the influence of opening ratios on the cracks distribution and shear strength of RC structural walls. The shear strength of the specimens was estimated by combining the shear strength of structural wall without openings and the reduction factor that takes into account the openings. Experimental and analytical results showed that the shear strength was different depending on the loading direction due to opening locations. A two-dimensional finite element analysis was carried out to simulate the performance of the tested specimens. The constructed finite elements model simulated the lateral load-drift angle relations quite well.

Shear Strength of an Aluminum Alloy Bonded with a DP-460 Adhesive: Single Lap-shear Joints

  • Kim, Hyun-Bum;Nishida, Tomohisa;Oguma, Hiroyuki;Naito, Kimiyoshi
    • 접착 및 계면
    • /
    • 제21권1호
    • /
    • pp.20-26
    • /
    • 2020
  • Single lap-shear joints (SLJ) specimens with and without partial round fillets were fabricated to measure the average shear strength of adhesives. The effects of the length of the adherend on the SLJ specimens were also investigated. An epoxy adhesive was used to bond aluminum alloy. Tensile tests were performed on the adhesive bulk specimens to measure the mechanical properties. The finite element analysis (FEA) method was used to measure the adhesive stress distributions, i.e., the peel and shear stresses, on the bonded part. The experimental results revealed that the specimen consisting short length of adherend and without the partial round fillets exhibited the smallest average shear strength of adhesive among the investigated specimens. FEA revealed that the low average shear strength for the specimen with a short adherend length was caused by high stress concentrations on the adhesive at the edge of the bonded part.

초간편 강합성 바닥판의 펀칭 전단에 관한 실험적 연구 (An Experimental Study on Punching Shear of Simplified Composite Deck)

  • 윤기용;이승열;이규세;김상섭
    • 한국방재학회 논문집
    • /
    • 제9권5호
    • /
    • pp.23-30
    • /
    • 2009
  • 현행 도로교설계기준의 바닥판에 대한 설계방법은 휨 이론에 따라 바닥판을 단위 폭의 보로 보고 강도설계법으로 설계하고 있다. 그러나 실제 교량 바닥판의 파괴 형태는 펀칭에 의한 파괴이므로 바닥판의 극한성능은 펀칭전단강도를 토대로 평가해야 할 것이다. 하지만 기존에 연구된 결과로는 초간편 강합성 바닥판의 펀칭전단강도를 산정하기 어려워 이에 대한 연구가 필요한 실정이다. 본 논문에서는 초간편 강합성 바닥판과 기존의 RC 바닥판에 대하여 펀칭전단강도실험을 실시하여 거동특성을 비교하였으며, 기존 RC 바닥판에 적용하고 있는 각국의 설계식들과 비교하였다.

Crack-controlled design methods of RC beams for ensuring serviceability and reparability

  • Chiu, Chien-Kuo;Saputra, Jodie;Putra, Muhammad Dachreza Tri Kurnia
    • Structural Engineering and Mechanics
    • /
    • 제82권6호
    • /
    • pp.757-770
    • /
    • 2022
  • For the design of flexural and shear crack control for reinforced concrete (RC) beams related to serviceability and reparability ensuring, eight simply-supported normal-strength reinforced concrete (NSRC) beam specimens are tested and the existing high-strength reinforced concrete (HSRC) experimental data are included in the investigation of this work. According to the investigation results of flexural and shear cracks, this works modifies the existing design formulas to determine the spacing of the tensile reinforcement for the flexural crack control of a HSRC/NSRC beam design. Additionally, for a specified shear crack width of 0.4 mm, the allowable stresses of the shear reinforcement are also identified. For the serviceability and reparability ensuring of HSRC/NSRC beams, this works proposes the relationship curves between the maximum flexural width and allowable stress of the tensile reinforcement, and the relationship curves between the shear crack width and allowable shear force that can be used to do the crack width control directly.

높이가 변하는 플레이트거더의 극한전단강도 (Ultimate Shear Strength of Tapered Steel Plate Girders)

  • 이두성;박찬식;이성철
    • 대한토목학회논문집
    • /
    • 제26권2A호
    • /
    • pp.391-399
    • /
    • 2006
  • 정 부모멘트 사이의 효과적인 휨강성분배를 통한 경제적인 단면을 설계하고 하부플랜지의 교축방향 곡선화를 통한 교량의 미를 도모하기 위해, 강플레이트거더 교각부에서 높이가 변하는 복부판을 설계에 종종 반영하고 있다. 이 같은 높이가 변하는 플레이트거더의 전단거동은 일반적인 플레이트거더에 비해 복잡하다. 그러나 관련연구의 부족으로 현행 하중-저항계 수설계규정은 명확한 전단설계기준을 제시하고 있지 못하다. 본 연구에서는 전단력을 받는 높이가 변하는 복부판의 탄성좌굴 및 극한전단거동을 조사하기 위해 다양한 매개변수가 고려된 3차원 유한요소해석이 수행되었으며, 해석결과로부터 높이가 변하는 복부판의 전단강도를 간단하며 합리적으로 산정할 수 있는 전단설계식을 제안하였다.

실내시험 시 재하속도가 미고결 및 고결 모래의 강도에 미치는 영향 (Effect of Shear Rate on Strength of Non-cemented and Cemented Sand in Laboratory Testing)

  • 문홍득;김정숙;우승욱;;박성식
    • 한국지반공학회논문집
    • /
    • 제37권11호
    • /
    • pp.23-36
    • /
    • 2021
  • 본 논문에서는 실내시험 시 재하속도가 미고결 모래의 내부 마찰각 그리고 고결모래의 일축압축강도에 미치는 영향에 대해 연구하였다. 건조상태의 주문진모래를 상대밀도 40%로 느슨하거나, 60%로 중간 정도 및 80%로 조밀한 상태로 제작한 다음 0.32, 0.64, 2.54mm/min의 재하속도로 직접전단시험을 실시하였다. 또한, 주문진모래에 시멘트 8% 및 12%로 다짐한 직경 50mm, 높이 100mm의 고결 공시체를 일축압축시험 시 0.1, 0.5, 1, 5, 10%/min의 재하속도로 압축하였다. 모래의 고결 여부나 정도에 관계없이 재하속도가 증가할수록 내부 마찰각과 일축압축강도는 증가하는 경향을 보였다. 미고결 모래의 경우 재하속도가 증가할수록 최대 4° 까지 내부 마찰각이 증가하였다. 고결 모래의 경우도 일반적으로 재하속도에 따라 일축압축강도가 증가하였으나, 표준 재하속도인 1%/min를 기준으로 증가하는 경향이 감소하였다. 또한, 개별요소법을 이용하여 고결 모래의 재하속도에 따른 균열 발생 및 발달 과정을 분석하였으며, 해석결과 또한 재하속도가 증가함에 따라 강도가 증가하는 경향을 보였으며 강도가 증가할수록 균열이 뚜렷하게 발달하였다.

Retrofitting of shear damaged RC beams using CFRP strips

  • Altin, Sinan;Anil, Ozgur;Toptas, Tolga;Kara, M. Emin
    • Steel and Composite Structures
    • /
    • 제11권3호
    • /
    • pp.207-223
    • /
    • 2011
  • The results of an experimental investigation are presented in this paper for retrofitting of shear damaged reinforced concrete beams by using U shaped CFRP strips. The experimental program is consisted of seven shear deficient T cross sectioned 1/2 scale simply supported beam specimens. One beam was used as reference specimen, and the remaining six specimens were tested in two stages. At the first stage, specimens were shear damaged severely, and then were retrofitted by using CFRP strips with or without fan type anchorages. Finally, retrofitted beams were tested up to failure. Three different CFRP strip spacing were used such as 125 mm, 150 mm, and 200 mm. The effect of anchorages on shear strength and behavior of the retrofitted specimens is investigated. CFRP strips without anchorages improved the shear strength, but no flexural failure mode was observed. Specimens showed brittle shear failure due to peeling of CFRP strip from RC beam surface. Shear damaged specimens retrofitted with anchoraged CFRP strips showed improved shear strength and ductile flexural failure. Maximum strains at anchoraged strips were approximately 68% larger than that of strips without anchorages.