The insulation characteristic of $SF_6$ at temperatures (온도변화에 따른 $SF_6$ 가스의 절연특성)

  • Park, K.T.;Park, K.S.;Lee, K.S.;Chio, P.J.;Do, D.H.;Yoon, Y.D.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1662-1664
    • /
    • 2002
  • 경제성장과 더불어 신뢰성이 높은 양질의 전기에너지의 공급이 필요하게 되었다. 최근에는 고압 $SF_6$가스를 절연매체로 하는 가스절연개폐기(Gas Insulate Switchgear:GIS)설비가 여러 지역에서 건설 운전 중이다. 본 논문은 GIS내의 $SF_6$가스의 온도변화에 따른 절연특성 및 $SF_6$의 액화에 따른 절연특성에 관한 연구이다.

  • PDF

Breakdown Characteristics of $SF_6-N_2$ Mixtures under Uniform and Non uniform Electricc Field (평등/불평등 전계에서 $SF_6-N_2$ 혼합가스의 절연파괴 특성연구)

  • Seo, C.S.;Lee, J.S.;Kim, J.T.;Koo, J.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2299-2301
    • /
    • 1999
  • In this work, experimental investigation was carried out for the breakdown characteristics of $SF_6$, $N_2$ and their mixtures under the uniform and non-uniform electric field, by use of HVAC and standard impulse testing voltages, as a function of different gas pressures from 1 atm to 5 atm. The results show that the dielectric strength of the $SF_6$ mixed in $N_2$ was significantly increased at its portion of 10%, which might imply that the optimum mixture of $SF_6$ for the HV switch gear could be proposed to be 10%.

  • PDF

Characteristics of $SF_6$ Gas for Kinds of Applied Voltage (인가전원에 따른 $SF_6$ 가스의 절연특성)

  • Yoon, D.H.;Choi, E.H.;Song, H.J.;Do, Y.H.;Kim, J.H.;Lee, K.S.
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.293-295
    • /
    • 2005
  • 산업현장에서 많이 사용되고 있는 전력기기의 이상 발생에는 여러 가지 원인이 있을 수 있다. 어떤 경우든 사고로 진전되면 경제적, 인적 손실이 발생된다. 본 논문은 GIS 및 많은 전력기기에서 사용되고 있는 절연매체인 $SF_6$의 인가되는 전압의 종류에 따라 저온에서의 절연파괴 특성을 알아보기 위해 모의 GIS 장치에 교류 전압 및 부극성 직류 전압 등 전원의 종류를 달리 하면서 각각의 전원 종류에 대한 $SF_6$가스의 절연파괴 전압을 측정하였다. 본 연구 결과는 SF6가스를 절연매체로 이용하는 전력기기를 혹한지역의 전력계통에서 사용할 때 전원의 종류에 따른 절연설계에 중요한 자료가 될 것으로 사료된다.

  • PDF

Characteristics of Frequency Spectrum & Ground Current Wave-form with Pressure Variation of $SF_6$ Gas (압력변화에 따른 $SF_6$ 가스의 주파수 스펙트럼 및 접지전류파형 특성)

  • Yoon, D.H.;Doo, Y.H.;Park, K.S.;Choi, S.T.;Kim, K.C.;Lee, K.S.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2088-2090
    • /
    • 2005
  • 산업현장에서 많이 사용되고 있는 전력기기에 결함이 발생하면 치명적인 사고로 진전되어 경제적, 인적 손실이 발생될 수 있다. 본 논문은 현재 대전력기기에서 많이 사용되는 $SF_6$ 절연가스의 압력 변화에 따른 부분방전을 모의하고, UHF법을 이용한 모의 GIS 내부 부분방전 신호 측정 및 접지전류를 측정하여 부분방전 시 방사되는 방사전자파의 스펙트럼 특성과 접지 전류 파형 특성을 분석하여, 챔버 내의 압력변화가 $SF_6$ 가스 부분방전에 미치는 영향을 측정하였다. 이러한 연구는 현장 GIS 및 $SF_6$가스 절연 전력설비에서 내부 압력 변화가 원인이 되어 발생되는 절연파괴 사고의 방지에 중요한 역할을 할 것으로 사료된다.

  • PDF

Fabrication and Properties of GaAs-MIS Capacitor using $SF_6$ Plasma Discharge ($SF_6$ 플라즈마 방전을 이용한 G3AS-MIS 커패시터의 제작 밑 특성)

  • 이남열;정순원;김광호;유병곤;이원재;유인규;양일석
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.29-32
    • /
    • 1999
  • $GaF_3$ films were directly grown on p' and p-type GaAs(100) substrates using a $SF_6$ plasma discharge system. GaAs MIS(Meta1-Insulator-Semiconductor) capacitor was successfully fabricated for about 1 hour at temperature $290^{\circ}C$ using the as-grown $GaF_3$ films. The as-grown films on p'-GaAs exhibited a current density of less than 6.68 $\times$ $1O^{-9}$ A/$cm^2$ at a breakdown field of 500kV/cm and a refractive index of 2.0 ~ 2.3 at a wavelength of 632.8 nm. The dielectric constant was about 5 derived from 1 MHz capacitance-voltage (C-V) measurements. Dielectric dispersion of the fluoridated films on p'-GaAs measured ranged from 100 Hz to 10 MHz was not observed.

  • PDF

Influence of Conducting Particle on the Breakdown Phenomena of $SF_6$ gas in Gas Insulated System ([$SF_6$] 가스 절연기기내에 도전성 금속이물 존재시 섬락전압에 미치는 영향)

  • Lee, B.W.;Ham, G.H.;Kim, I.S.;Koo, J.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1687-1689
    • /
    • 1998
  • In this work, the behaviours of conducting wire type particles within the coaxial electrode gap energized with high ac voltage have been systematically investigated using charge simulation method. For this, spheroidal charge is adopted as a image charge for the CSM analysis in order to calculate the acquired charge of the particles which are erected on the surface of the outer electrode. For this purpose, the effects of the lengths and diameters of Cu, Al particles in gas insulated system have been studied by a numerical computation and particle lifting voltage, lifting field, breakdown voltage, acquired charge and travelling distance have been considered. From this, we understand that the particle behaviours have different characteristics according to the particle lengths and diameters. And a possible countermeasure, based on the proposed simulation, has been provided with a view to estimating the flashover voltage of $SF_6$ gas under the 1 atm.

  • PDF

Analysis on Temperature Distribution and Current-Carrying Capacity of GIL Filled with Fluoronitriles-CO2 Gas Mixture

  • Chen, Geng;Tu, Youping;Wang, Cong;Cheng, Yi;Jiang, Han;Zhou, Hongyang;Jin, Hua
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.6
    • /
    • pp.2402-2411
    • /
    • 2018
  • Fluoronitriles-$CO_2$ gas mixtures are promising alternatives to $SF_6$ in environmentally-friendly gas-insulated transmission lines (GILs). Insulating gas heat transfer characteristics are of major significance for the current-carrying capacity design and operational state monitoring of GILs. In this paper, a three-dimensional calculation model was established for a GIL using the thermal-fluid coupled finite element method. The calculated results showed close agreement with experimentally measured data. The temperature distribution of a GIL filled with the Fluoronitriles-$CO_2$ mixture was obtained and compared with those of GILs filled with $CO_2$ and $SF_6$. Furthermore, the effects of the mixture ratio of the component gases and the gas pressure on the temperature rise and current-carrying capacity of the GIL were analyzed. Results indicated that the heat transfer performance of the Fluoronitriles-$CO_2$ gas mixture was better than that of $CO_2$ but worse than that of $SF_6$. When compared with $SF_6$, use of the Fluoronitriles-$CO_2$ gas mixture caused a reduction in the GIL's current-carrying capacity. In addition, increasing the Fluoronitriles gas component ratio or increasing the pressure of the insulating gas mixture could improve the heat dissipation and current-carrying capacity of the GIL. These research results can be used to design environmentally-friendly GILs containing Fluoronitriles-$CO_2$ gas mixtures.

Investigation of the Supercritical Fluids as an Insulating Medium for High Speed Switching

  • Shon, Chae-Hwa;Song, Ki-Dong;Oh, Yeon-Ho;Oh, Ho-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.6
    • /
    • pp.1783-1786
    • /
    • 2016
  • The paper investigates the insulation properties of the supercritical $CO_2$ ($SCCO_2$) fluid as an insulating medium for electrical apparatuses. The insulating material is crucial for electrical apparatuses and $SF_6$ gas has been widely used for high power electrical apparatuses. There have been many research efforts to develop substituents for $SF_6$ gas because of high global warming potential. We obtained above 350 kV/mm insulation strength with 12.0 MPa $SCCO_2$. The positive and negative IEC standard pulses are applied between two 10 mm diameter spherical electrodes. The insulation strength of $SCCO_2$ is at least 2.5 times higher than that of $CO_2$ gas at 6.0MPa. The insulation strength of $SCCO_2$ fluid is about 10 times higher than that of $SF_6$ at 0.5MPa which is the ordinary operating pressure of electrical switchgears. Using the result, we expect that the time for switching and dielectric recovery could be reduced using $SCCO_2$ fluid as an insulating medium.

Predischarge Phenomena in Nonuniform Fields Caused by Lightning Impulse Voltages in SF(sub)6-$N_2$Mixtures (SF(sub)6-$N_2$혼합가스중에 뇌임펄스전압에 의해 형성된 불평등전장에서의 전구방전현상)

  • 이복희;이경옥;백승권
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.6
    • /
    • pp.288-295
    • /
    • 2001
  • Predischarges in nonuniform electric field stressed by lightning impulse voltagesin SF(sub)6-$N_2$mixtures are initiated by streamer coronas. Due to field ehnancement at a protrusion point of electrodes new ionization processes occur and a precursor, which leads to a first leader, is created. The leader proceeds step by step to the opposite electrode and the final jump bridges the test gap. It was found that the predischarge is propagated with a leader mechanism of stepwise expansion from the predischarge current waveforms measured by a shunt. The predischarge current is closely related to the amplitude and polarity of applied voltages, the gas pressure and the gap geometry. The time intervals between step leaders for the positive and negative polarities were inversely proportional to V.P$^2$. When the gas pressure increases in the positive polarity, statistical time lag to statistical time lag to streamer corona inception increase slightly, but the formative time lag to flashover is significantly decreased.

  • PDF