• Title/Summary/Keyword: SET*

Search Result 38,053, Processing Time 0.065 seconds

Usefulness of Pulsatile Flow Aortic Aneurysm Phantoms for Stent-graft Placement (스텐트그라프트 장치술을 위한 대동맥류 혈류 팬텀의 유용성)

  • Kim, Tae-Hyung;Ko, Gi-Young;Song, Ho-Young;Park, In-Kook;Shin, Ji-Hoon;Lim, Jin-Oh;Kim, Jin-Hyoung;Choi, Eu-Gene K.
    • Journal of radiological science and technology
    • /
    • v.30 no.3
    • /
    • pp.205-212
    • /
    • 2007
  • To evaluate the feasibility and efficacy of a pulsatile aortic aneurysm phantoms for in-vitro study. The phantoms consisted of a pulsating motor part(heart part) and an aortic aneurysm part, which mimicked true physiologic conditions. The heart part was created from a high-pressured water pump and a pulsatile flow solenoid valve for the simulation of aortic flow. The aortic aneurysm part was manufactured from paper clay, which was placed inside a acrylic plastic square box, where liquid silicone was poured. After the silicone was formed, the clay was removed, and a silicone tube was used to connect the heart and aneurysm part. We measured the change in pressure as related to the opening time(pulse rate, Kruskal-Wallis method) and pressure before and after the stent-graft implantation(n = 5, Wilcoxon's signed ranks test). The changes in blood pressures according to pulse rate were all statistically significant(p<0.05). The systolic/diastolic pressures at the proximal aorta, the aortic aneurysm, and the distal aorta of the model were $157.80{\pm}1.92/130.20{\pm}1.92$, $159.40{\pm}1.14/134.00{\pm}2.92$, and $147.20{\pm}1.480/129.60{\pm}2.70\;mmHg$, respectively, when the pulse rate was 0.5 beat/second. The pressures changed to $161.40{\pm}1.34/90.20{\pm}1.64$, $175.00{\pm}1.58/93.00{\pm}1.58$, and $176.80{\pm}1.48/90.80{\pm}1.92\;mmHg$, respectively, when the pulse rate was 1.0 beat/second, and $159.40{\pm}1.82/127.20{\pm}1.48$, $166.60{\pm}1.67/138.00{\pm}1.87$, and $161.00{\pm}1.22/135.40{\pm}1.67\;mmHg$, respectively, when it was 1.5 beat/second. When pulse rate was set at 1.0 beat/second, the pressures were $143.60{\pm}1.67/90.20{\pm}1.64$, $147.20{\pm}1.92/84.60{\pm}1.82$, and $137.40{\pm}1.52/88.80{\pm}1.64\;mmHg$ after stent-graft implantation. The changes of pressure before and after stent-graft implantation were statistically significant(p<0.05) except the diastolic pressures at the proximal(p =1.00) and distal aorta(p=0.157). The aortic aneurysm phantoms seems to be useful for the evaluation of the efficacy of stent-graft before animal or clinical studies because of its easy reproducibility and ability to display a wide range of pressures.

  • PDF

Analysis and Improvement Strategies for Korea's Cyber Security Systems Regulations and Policies

  • Park, Dong-Kyun;Cho, Sung-Je;Soung, Jea-Hyen
    • Korean Security Journal
    • /
    • no.18
    • /
    • pp.169-190
    • /
    • 2009
  • Today, the rapid advance of scientific technologies has brought about fundamental changes to the types and levels of terrorism while the war against the world more than one thousand small and big terrorists and crime organizations has already begun. A method highly likely to be employed by terrorist groups that are using 21st Century state of the art technology is cyber terrorism. In many instances, things that you could only imagine in reality could be made possible in the cyber space. An easy example would be to randomly alter a letter in the blood type of a terrorism subject in the health care data system, which could inflict harm to subjects and impact the overturning of the opponent's system or regime. The CIH Virus Crisis which occurred on April 26, 1999 had significant implications in various aspects. A virus program made of just a few lines by Taiwanese college students without any specific objective ended up spreading widely throughout the Internet, causing damage to 30,000 PCs in Korea and over 2 billion won in monetary damages in repairs and data recovery. Despite of such risks of cyber terrorism, a great number of Korean sites are employing loose security measures. In fact, there are many cases where a company with millions of subscribers has very slackened security systems. A nationwide preparation for cyber terrorism is called for. In this context, this research will analyze the current status of Korea's cyber security systems and its laws from a policy perspective, and move on to propose improvement strategies. This research suggests the following solutions. First, the National Cyber Security Management Act should be passed to have its effectiveness as the national cyber security management regulation. With the Act's establishment, a more efficient and proactive response to cyber security management will be made possible within a nationwide cyber security framework, and define its relationship with other related laws. The newly passed National Cyber Security Management Act will eliminate inefficiencies that are caused by functional redundancies dispersed across individual sectors in current legislation. Second, to ensure efficient nationwide cyber security management, national cyber security standards and models should be proposed; while at the same time a national cyber security management organizational structure should be established to implement national cyber security policies at each government-agencies and social-components. The National Cyber Security Center must serve as the comprehensive collection, analysis and processing point for national cyber crisis related information, oversee each government agency, and build collaborative relations with the private sector. Also, national and comprehensive response system in which both the private and public sectors participate should be set up, for advance detection and prevention of cyber crisis risks and for a consolidated and timely response using national resources in times of crisis.

  • PDF

A Study on the Availability of the On-Board Imager(OBI) and Cone-Beam CT(CBCT) in the Verification of Patient Set-up (온보드 영상장치(On-Board Imager) 및 콘빔CT(CBCT)를 이용한 환자 자세 검증의 유용성에 대한 연구)

  • Bak, Jino;Park, Sung-Ho;Park, Suk-Won
    • Radiation Oncology Journal
    • /
    • v.26 no.2
    • /
    • pp.118-125
    • /
    • 2008
  • Purpose: On-line image guided radiation therapy(on-line IGRT) and(kV X-ray images or cone beam CT images) were obtained by an on-board imager(OBI) and cone beam CT(CBCT), respectively. The images were then compared with simulated images to evaluate the patient's setup and correct for deviations. The setup deviations between the simulated images(kV or CBCT images), were computed from 2D/2D match or 3D/3D match programs, respectively. We then investigated the correctness of the calculated deviations. Materials and Methods: After the simulation and treatment planning for the RANDO phantom, the phantom was positioned on the treatment table. The phantom setup process was performed with side wall lasers which standardized treatment setup of the phantom with the simulated images, after the establishment of tolerance limits for laser line thickness. After a known translation or rotation angle was applied to the phantom, the kV X-ray images and CBCT images were obtained. Next, 2D/2D match and 3D/3D match with simulation CT images were taken. Lastly, the results were analyzed for accuracy of positional correction. Results: In the case of the 2D/2D match using kV X-ray and simulation images, a setup correction within $0.06^{\circ}$ for rotation only, 1.8 mm for translation only, and 2.1 mm and $0.3^{\circ}$ for both rotation and translation, respectively, was possible. As for the 3D/3D match using CBCT images, a correction within $0.03^{\circ}$ for rotation only, 0.16 mm for translation only, and 1.5 mm for translation and $0.0^{\circ}$ for rotation, respectively, was possible. Conclusion: The use of OBI or CBCT for the on-line IGRT provides the ability to exactly reproduce the simulated images in the setup of a patient in the treatment room. The fast detection and correction of a patient's positional error is possible in two dimensions via kV X-ray images from OBI and in three dimensions via CBCT with a higher accuracy. Consequently, the on-line IGRT represents a promising and reliable treatment procedure.

Review of 2015 Major Medical Decisions (2015년 주요 의료판결 분석)

  • Yoo, Hyun Jung;Lee, Dong Pil;Lee, Jung Sun;Jeong, Hye Seung;Park, Tae Shin
    • The Korean Society of Law and Medicine
    • /
    • v.17 no.1
    • /
    • pp.299-346
    • /
    • 2016
  • There were also various decisions made in medical area in 2015. In the case that an inmate in a sanatorium was injured due to the reason which can be attributable to the sanatorium and the social welfare foundation that operates the sanatorium request treatment of the patient, the court set the standard of fixation of a party in medical contract. In the case that the family of the patient who was declared brain dead required withdrawal of meaningless life sustaining treatment but the hospital rejected and continued the treatment, the court made a decision regarding chargeable fee for such treatment. When it comes to the eye brightening operation which received measure of suspension from the Ministry of Health and Welfare for the first time in February, 2011, because of uncertainty of its safety, the court did not accept the illegality of such operation itself, however, ordered compensation of the whole damage based on the violation of liability for explanation, which is the omission of explanation about the fact that the cost-effectiveness is not sure as it is still in clinical test stage. There were numerous cases that courts actively acknowledged malpractices; in the cases of paresis syndrome after back surgery, quite a few malpractices during the surgery were acknowledged by the court and in the case of nosocomial infection, hospital's negligence to cause such nosocomial infection was acknowledged by the court. There was a decision which acknowledged malpractice by distinguishing the duty of installation of emergency equipment according to the Emergency Medical Service Act and duty of emergency measure in emergency situations, and a decision which acknowledged negligence of a hospital if the hospital did not take appropriate measures, although it was a very rare disease. In connection with the scope of compensation for damage, there were decisions which comply with substantive truth such as; a court applied different labor ability loss rate as the labor ability loss rate decreased after result of reappraisal of physical ability in appeal compared to the one in the first trial, and a court acknowledged lower labor ability loss rate than the result of appraisal of physical ability considering the condition of a patient, etc. In the event of any damage caused by malpractice, in regard to whether there is a limitation on liability in fee charge after such medical malpractice, the court rejected the hospital's claim for setoff saying that if the hospital only continued treatments to cure the patient or prevent aggravation of disease, the hospital cannot charge Medical bills to the patient. In regard to the provision of the Medical Law that prohibit medical advertisement which was not reviewed preliminarily and punish the violation of such, a decision of unconstitutionality was made as it is a precensorship by an administrative agency as the deliberative bodies such as Korean Medical Association, etc. cannot be denied to be considered as administrative bodies. When it comes to the issue whether PRP treatment, which is commonly performed clinically, should be considered as legally determined uninsured treatment, the court made it clear that legally determined uninsured treatment should not be decided by theoretical possibility or actual implementation but should be acknowledged its medical safety and effectiveness and included in medical care or legally determined uninsured treatment. Moreover, court acknowledged the illegality of investigation method or process in the administrative litigation regarding evaluation of suitability of sanatorium, however, denied the compensation liability or restitution of unjust enrichment of the Health Insurance Review & Assessment Service and the National Health Insurance Corporation as the evaluation agents did not cause such violation intentionally or negligently. We hope there will be more decisions which are closer to substantive truth through clear legal principles in respect of variously arisen issues in the future.

  • PDF

The Evaluation of SUV Variations According to the Errors of Entering Parameters in the PET-CT Examinations (PET/CT 검사에서 매개변수 입력오류에 따른 표준섭취계수 평가)

  • Kim, Jia;Hong, Gun Chul;Lee, Hyeok;Choi, Seong Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.43-48
    • /
    • 2014
  • Purpose: In the PET/CT images, The SUV (standardized uptake value) enables the quantitative assessment according to the biological changes of organs as the index of distinction whether lesion is malignant or not. Therefore, It is too important to enter parameters correctly that affect to the SUV. The purpose of this study is to evaluate an allowable error range of SUV as measuring the difference of results according to input errors of Activity, Weight, uptake Time among the parameters. Materials and Methods: Three inserts, Hot, Teflon and Air, were situated in the 1994 NEMA Phantom. Phantom was filled with 27.3 MBq/mL of 18F-FDG. The ratio of hotspot area activity to background area activity was regulated as 4:1. After scanning, Image was re-reconstructed after incurring input errors in Activity, Weight, uptake Time parameters as ${\pm}5%$, 10%, 15%, 30%, 50% from original data. ROIs (region of interests) were set one in the each insert areas and four in the background areas. $SUV_{mean}$ and percentage differences were calculated and compared in each areas. Results: $SUV_{mean}$ of Hot. Teflon, Air and BKG (Background) areas of original images were 4.5, 0.02. 0.1 and 1.0. The min and max value of $SUV_{mean}$ according to change of Activity error were 3.0 and 9.0 in Hot, 0.01 and 0.04 in Teflon, 0.1 and 0.3 in Air, 0.6 and 2.0 in BKG areas. And percentage differences were equally from -33% to 100%. In case of Weight error showed $SUV_{mean}$ as 2.2 and 6.7 in Hot, 0.01 and 0.03 in Tefron, 0.09 and 0.28 in Air, 0.5 and 1.5 in BKG areas. And percentage differences were equally from -50% to 50% except Teflon area's percentage deference that was from -50% to 52%. In case of uptake Time error showed $SUV_{mean}$ as 3.8 and 5.3 in Hot, 0.01 and 0.02 in Teflon, 0.1 and 0.2 in Air, 0.8 and 1.2 in BKG areas. And percentage differences were equally from 17% to -14% in Hot and BKG areas. Teflon area's percentage difference was from -50% to 52% and Air area's one was from -12% to 20%. Conclusion: As shown in the results, It was applied within ${\pm}5%$ of Activity and Weight errors if the allowable error range was configured within 5%. So, The calibration of dose calibrator and weighing machine has to conduct within ${\pm}5%$ error range because they can affect to Activity and Weight rates. In case of Time error, it showed separate error ranges according to the type of inserts. It showed within 5% error when Hot and BKG areas error were within ${\pm}15%$. So we have to consider each time errors if we use more than two clocks included scanner's one during the examinations.

  • PDF

The Correction Factor of Sensitivity in Gamma Camera - Based on Whole Body Bone Scan Image - (감마카메라의 Sensitivity 보정 Factor에 관한 연구 - 전신 뼈 영상을 중심으로 -)

  • Jung, Eun-Mi;Jung, Woo-Young;Ryu, Jae-Kwang;Kim, Dong-Seok
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.208-213
    • /
    • 2008
  • Purpose: Generally a whole body bone scan has been known as one of the most frequently executed exams in the nuclear medicine fields. Asan medical center, usually use various gamma camera systems - manufactured by PHILIPS (PRECEDENCE, BRIGHTVIEW), SIEMENS (ECAM, ECAM signature, ECAM plus, SYMBIA T2), GE (INFINIA) - to execute whole body scan. But, as we know, each camera's sensitivity is not same so it is hard to consistent diagnosis of patients. So our purpose is when we execute whole body bone scans, we exclude uncontrollable factors and try to correct controllable factors such as inherent sensitivity of gamma camera. In this study, we're going to measure each gamma camera's sensitivity and study about reasonable correction factors of whole body bone scan to follow up patient's condition using different gamma cameras. Materials and Methods: We used the $^{99m}Tc$ flood phantom, it recommend by IAEA recommendation based on general counts rate of a whole body scan and measured counts rates by the use of various gamma cameras - PRECEDENCE, BRIGHTVIEW, ECAM, ECAM signature, ECAM plus, IFINIA - in Asan medical center nuclear medicine department. For measuring sensitivity, all gamma camera equipped LEHR collimator (Low Energy High Resolution multi parallel Collimator) and the $^{99m}Tc$ gamma spectrum was adjusted around 15% window level, the photo peak was set to 140-kev and acquirded for 60 sec and 120 sec in all gamma cameras. In order to verify whether can apply calculated correction factors to whole body bone scan or not, we actually conducted the whole body bone scan to 27 patients and we compared it analyzed that results. Results: After experimenting using $^{99m}Tc$ flood phantom, sensitivity of ECAM plus was highest and other sensitivity order of all gamma camera is ECAM signature, SYMBIA T2, ECAM, BRIGHTVIEW, IFINIA, PRECEDENCE. And yield sensitivity correction factor show each gamma camera's relative sensitivity ratio by yielded based on ECAM's sensitivity. (ECAM plus 1.07, ECAM signature 1.05, SYMBIA T2 1.03, ECAM 1.00, BRIGHTVIEW 0.90, INFINIA 0.83, PRECEDENCE 0.72) When analyzing the correction factor yielded by $^{99m}Tc$ experiment and another correction factor yielded by whole body bone scan, it shows statistically insignificant value (p<0.05) in whole body bone scan diagnosis. Conclusion: In diagnosing the bone metastasis of patients undergoing cancer, whole body bone scan has been conducted as follow up tests due to its good points (high sensitivity, non invasive, easily conducted). But as a follow up study, it's hard to perform whole body bone scan continuously using same gamma camera. If we use same gamma camera to patients, we have to consider effectiveness of equipment's change by time elapsed. So we expect that applying sensitivity correction factor to patients who tested whole body bone scan regularly will add consistence in diagnosis of patients.

  • PDF

The effect of four different temperatures on the growth of Aedes albopictus larva (네 가지 다른 온도가 흰줄숲모기(Aedes albopictus) 유충 생장에 미치는 영향)

  • Na, Sumi;Jang, Hyeji;Park, Sojung;Lee, Eunyoung;Doh, Jiseon;Hong, Seungbie;Yi, Hoonbok
    • Journal of Wetlands Research
    • /
    • v.20 no.2
    • /
    • pp.155-160
    • /
    • 2018
  • We investigated to know the growth patterns of Aedes albopictus larva at the four different temperature conditions. Each of 120 individuals was placed into a $20m{\ell}$ vial and 12 sets (a set of 10 vials) were separated into 12 water tanks ($17{\times}24{\times}18cm^3$). Each water tank was composed of 3 the $1^{st}$ instar, 3 the $2^{nd}$ instar, 2 the $3^{rd}$ instar, and 2 the $4^{th}$ instar. Three sets of water tanks were placed under the four different incubator temperatures ($17^{\circ}C$, $21^{\circ}C$, $24^{\circ}C$, $28^{\circ}C$). We found that the eclosion rates were $20.00{\pm}5.77%$ at $21^{\circ}C$ and $3.33{\pm}3.33%$ at other temperatures. For the mosquito larva mortality rate, $1^{st}$ instar was $19.24{\pm}3.65%$, $2^{nd}$ instar was $16.48{\pm}3.25%$, $3^{rd}$ instar was $23.54{\pm}5.06%$, and $4^{th}$ instar was $40.74{\pm}7.08%$. The lowest mortality rate in growth stages according to temperature was $13.33{\pm}6.67%$ at $17^{\circ}C$ in $1^{st}$ instar larva, $7.41{\pm}7.41%$ at $21^{\circ}C$ at $2^{nd}$ instar larva, $10.74{\pm}6.43%$ at $24^{\circ}C$ in $3^{rd}$ instar larva, and $20.37{\pm}5.46%$ at $28^{\circ}C$ in $4^{th}$ instar larva. The survival period of mosquitoes in underwater were $26.33{\pm}0.67days$ at $17^{\circ}C$, $23.33{\pm}1.33days$ at $21^{\circ}C$, $20.00{\pm}2.52days$ at $24^{\circ}C$, and $11.67{\pm}1.20days$ at $28^{\circ}C$. From our results the most effective temperature to the normal growth of mosquito larva was $21^{\circ}C$, and the highest mortality rate was shown at the $4^{th}$ instar stage of larva growth. Our results would provide the basic data for the mosquito larva's growth pattern.

Geological Structure of the Moisan Epithermal Au-Ag Mineralized Zone, Haenam and its Tectonic Environment at the Time of the Mineralization (해남 모이산 천열수 금-은 광호대의 지질구조와 광화작용 당시의 지구조환경)

  • Kang, Ji-Hoon;Lee, Deok-Seon;Ryoo, Chung-Ryul;Koh, Sang-Mo;Chi, Se-Jung
    • Economic and Environmental Geology
    • /
    • v.44 no.5
    • /
    • pp.413-431
    • /
    • 2011
  • An Epithemal Au-Ag mineralized zone is developed in the Moisan area of Hwangsan-myeon, Haenam-gun, Jeol-lanam-do, Korea, which is located in the southwestern part of the Ogcheon metamorphic zone. It is hosted in the Hwangsan volcaniclastics of the Haenam Formation of the Late Cretaceous Yucheon Group. This research investigated the characteristics of bedding arrangement, fold, fault, fracture system, quartz vein and the time-relationship of the fracture system to understand the geological structure related to the formation of the mineralized zone. On the basis of this result, the tectonic environment at the time of the mineralization was considered. Beds mainly trend east-northeast and gently dip into north-northwest or south-southeast. Their poles have been rearranged by subhorizontal-upright open fold of (east)-northeast trend as well as dip-slip fault. Fracture system was formed through at least 6~7 different deformation events. D1 event; formation phase of the main fracture set of EW (D1-1) and NS (D1-2) trends with a good extensity, D2 event; that of the extension fracture of NW trend, and conjugate shear fracturing of the EW (dextral) and NS (sinistral) trends, D3 event; that of the extension fracture of NE trend, and conjugate shear refracturing of the EW (sinistral) and NS (dextral) trends, D4 event; that of the extension fracture of NS trend showing a poor extensity, D5 event; that of the extension fracture of NW trend, and conjugate shear refracturing of the EW (dextral) and NS (sinistral) trends, D6 event; that of the extension fracture of EW trend showing a poor extensity. Frequency distribution of fracture sets of each deformation event is D1-1 (19.73 %)> D1-2 (16.44 %)> D3=D5 (14.79 %)> D2 (13.70 %)> D4 (12.33 %)> D6 (8.22 %) in descending order. The average number of fracture sets within 1 meter at each deformation event is D6 (5.00)> D5 = D4 (4.67)> D2 (4.60)> D3 (4.13)> D1-1 (3.33)> D1-2 (2.83) in descending order. The average density of all fractures shows 4.20 fractures/1 m, that is, the average spacing of all fractures is more than 23.8 cm. The frequency distribution of quartz veins at each orientation is as follows: EW (52 %)> NW (28 %)> NS (12 %)> NE (8 %) trends in descending order. The average density of all quartz veins shows 4.14 veins/1 m, that is, the average spacing of all quartz veins is more than 24.2 cm. Microstructural data on the quartz veins indicate that the epithermal Au-Ag mineralization (ca. 77.9~73.1 Ma) in the Moisan area seems to occur mainly along the existing D1 fracture sets of EW and NS trends with a good extensity not under tectonic stress but non-deformational environment directly after epithermal rupture fracturing. The D1 fracturing is considered to occur under the unstable tectonic environment which alternates compression and tension of NS trend due to the oblique northward subduction of the Izanagi plate resulting in the igneous activity and deformation of the Yucheon Group and the Bulguksa igneous rocks during Late Cretaceous time.

Adaptive RFID anti-collision scheme using collision information and m-bit identification (충돌 정보와 m-bit인식을 이용한 적응형 RFID 충돌 방지 기법)

  • Lee, Je-Yul;Shin, Jongmin;Yang, Dongmin
    • Journal of Internet Computing and Services
    • /
    • v.14 no.5
    • /
    • pp.1-10
    • /
    • 2013
  • RFID(Radio Frequency Identification) system is non-contact identification technology. A basic RFID system consists of a reader, and a set of tags. RFID tags can be divided into active and passive tags. Active tags with power source allows their own operation execution and passive tags are small and low-cost. So passive tags are more suitable for distribution industry than active tags. A reader processes the information receiving from tags. RFID system achieves a fast identification of multiple tags using radio frequency. RFID systems has been applied into a variety of fields such as distribution, logistics, transportation, inventory management, access control, finance and etc. To encourage the introduction of RFID systems, several problems (price, size, power consumption, security) should be resolved. In this paper, we proposed an algorithm to significantly alleviate the collision problem caused by simultaneous responses of multiple tags. In the RFID systems, in anti-collision schemes, there are three methods: probabilistic, deterministic, and hybrid. In this paper, we introduce ALOHA-based protocol as a probabilistic method, and Tree-based protocol as a deterministic one. In Aloha-based protocols, time is divided into multiple slots. Tags randomly select their own IDs and transmit it. But Aloha-based protocol cannot guarantee that all tags are identified because they are probabilistic methods. In contrast, Tree-based protocols guarantee that a reader identifies all tags within the transmission range of the reader. In Tree-based protocols, a reader sends a query, and tags respond it with their own IDs. When a reader sends a query and two or more tags respond, a collision occurs. Then the reader makes and sends a new query. Frequent collisions make the identification performance degrade. Therefore, to identify tags quickly, it is necessary to reduce collisions efficiently. Each RFID tag has an ID of 96bit EPC(Electronic Product Code). The tags in a company or manufacturer have similar tag IDs with the same prefix. Unnecessary collisions occur while identifying multiple tags using Query Tree protocol. It results in growth of query-responses and idle time, which the identification time significantly increases. To solve this problem, Collision Tree protocol and M-ary Query Tree protocol have been proposed. However, in Collision Tree protocol and Query Tree protocol, only one bit is identified during one query-response. And, when similar tag IDs exist, M-ary Query Tree Protocol generates unnecessary query-responses. In this paper, we propose Adaptive M-ary Query Tree protocol that improves the identification performance using m-bit recognition, collision information of tag IDs, and prediction technique. We compare our proposed scheme with other Tree-based protocols under the same conditions. We show that our proposed scheme outperforms others in terms of identification time and identification efficiency.

Essay on Form and Function Design (디자인의 형태와 기능에 관한 연구)

  • 이재국
    • Archives of design research
    • /
    • v.2 no.1
    • /
    • pp.63-97
    • /
    • 1989
  • There is nothing more important than the form and function in design, because every design product can be done on the basis of them. Form and Function are already existed before the word of design has been appeared and all the natural and man-made things' basic organization is based on their organic relations. The organic relations is the source of vitality which identifies the subsistance of all the objects and the evolution of living creatures has been changed their appearances by the natural law and order. Design is no exception. Design is a man-made organic thing which is developed its own way according to the purposed aim and given situations. If so, what is the ultimate goal of design. It is without saying that the goal is to make every effort to contribute to the -human beings most desirable life by the designer who is devoting himself to their convenience and well-being. Therefore, the designer can be called the man of rich life practitioner. This word implies a lot of meanings since the essence of design is improving the guality of life by the man-made things which are created by the designer. Also, the things are existed through the relations between form and function, and the things can keep their value when they are answered to the right purpose. In design, thus, it is to be a main concern how to create valuable things and to use them in the right way, and the subject of study is focused on the designer's outlook of value and uk relations between form and function. Christopher Alexander mentioned the importance of form as follows. The ultimate object of design is form. Every design problem begins with an effort to achieve fittness between the form and its context. The form is the solution to the problem: the context defmes the problem. In other words, when we speak of design, the real object of discussion is not form alone, but the ensemble comprising the form and its context. Good fit is a desirable property of this ensemble which relates to some particular division of the ensemble into form and context. Max Bill mainatined how important form is in design. Form represents a self-contained concept, and its embodiment in an object results in that object becoming a work of art. Futhermore, this explains why we use form so freguently in a comparative sense for determining whether one thing is less or more beautiful than another, and why the ideal of absolute beauty is always the standard by which we appraise form, and through form, art itself. Hence form has became synonymous with beauty. On the other hand, Laszlo Moholy-Nagy stated the importance of function as follows. Function means the task an object is designed to fulfill the task instrument is shaping the form. Unfortunately, this principle was not appreciated at the same time but through the endeavors of Frank Lloyd Wright and of the Bauhaus group and its many collegues in Europe, the idea of functionalism became the keynote of the twenites. Functionalism soon became a cheap slogan, however, and its original meaning blurred. It is neccessary to reexamine it in the light of present circumstances. Charles William Eliot expressed his idea on the relations between function and beauty. Beauty often results chiefly from fittness: indeed it is easy to manitain that nothing is fair except what is fit its uses or functions. If the function of the product of a machine be useful and valuable, an the machine be eminently fit for its function, it conspicuously has the beauty of fittness. A locomotive or a steamship has the same sort of beauty, derived from the supreme fittness for its function. As functions vary, so will those beauty..vary. However, it is impossible to study form and function in separate beings. Function can't be existed without form, and without function, form is nothing. In other words, form is a function's container, and function is content in form. It can be said that, therefore, the form and function are indispensable and commensal individuals which have coetemal relations. From the different point of view, sometimes, one is more emphasized than the other, but in this case, the logic is only accepted on the assumption of recognizing the importance of the other's entity. The fact can be proved what Frank Hoyd wright said that form and function are one. In spite of that, the form and function should be considered as independent indivisuals, because they are too important to be treated just as the simple single one. Form and function have flexible properties to the context. In other words, the context plays a role as the barometer to define the form and function, also which implies every meaning of surroun'||'&'||'not;dings. Thus, design is formed under the influence of situations. Situations are dynamic, like the design process itself, in which fixed focus can be cripping. Moreover, situations control over making the good design. Judging from the respect, I defined the good design in my thesis An Analytic Research on Desigh Ethic, "good design is to solve the problem by the most proper way in the situations." Situations are changeable, and so is design. There is no progress without change, but change is not neccessarily progress. It is highly desirable that there changes be beneficial to mankind. Our main problem is to be able to discriminate between that which should be discarded and that which should be kept, built upon, and improved. Form and Function are no exception. The practical function gives birth to the inevitable form and the $$\mu$ti-classified function is delivered to the varieties of form. All of these are depended upon changeable situations. That is precisely the situations of "situation de'||'&'||'not;sign", the concept of moving from the design of things to the design of the circumstances in which things are used. From this point of view, the core of form and function is depended upon how the designer can manage it efficiently in given situations. That is to say that the creativity designer plays an important role to fulfill the purpose. Generally speaking, creativity is the organization of a concept in response to a human need-a solution that is both satisfying and innovative. In order to meet human needs, creative design activities require a special intuitive insight which is set into motion by purposeful imagination. Therefore, creativity is the most essential quality of every designer. In addition, designers share with other creative people a compulsive ingenuity and a passion for imaginative solutions which will meet their criteria for excellence. Ultimately, it is said that the form and function is the matter which belongs to the desire of creative designers who constantly try to bring new thing into being to create new things. In accordance with that the main puppose of this thesis is to catch every meaning of the form and function and to close analyze their relations for the promotion of understanding and devising practical application to gradual progression in design. The thesis is composed of four parts: Introduction, Form, Function and Conclusion. Introduction, the purpose and background of the research are presented. In Chapter I, orgin of form, perception of form, and classification of form are studied. In Chapter II, generation of function, development of function, and diversification of function are considered. Conclusion, some concluding words are mentioned.ioned.

  • PDF