• Title/Summary/Keyword: SEP

Search Result 1,148, Processing Time 0.023 seconds

Clinical Somatosensory Evoked Potential (임상 체성감각 유발전위 검사)

  • Ryoo, Jae-Kwan;Kim, Jong-Soon
    • Journal of Korean Physical Therapy Science
    • /
    • v.3 no.1
    • /
    • pp.907-918
    • /
    • 1996
  • Evoked potentials(EP) are defined as electric responses of the nerves system to sensory stimulation. EPs are used mainly to test conduction in the visual, auditory, and somatosensory systems, especially in the central parts of these systems. Somatosensory evoked potentials (SEP) are the potentials elicited by stimulation of peripheral nerves and recorded at various sites along the sensory pathway. SEPs types consist mainly of SEPs to electric stimulation of arm or leg nerves. SEPs to arm stimulation are usually recorded simultaneously from clavicular, cervical, and scalp electrodes; SEPs to leg stimulation are recorded from lumbar, low thoracic, and scalp electrodes. Subject variables that have practical impotance are age, limb length, body height, and temperature. General clinical interpretation of abnormal SEPs wave decreases of peripheral conduction time, and abolition of SEPs recorded from different levels to identify lesions of peripheral nerves, plexus, nerve root, spinal cord, cauda equina, hemispheric brainstem, and cerebral parts of the somatosensory pathway.

  • PDF

Quantitative Analysis of Indomethacin by the Portable Near-Infrared (NIR) System (근적외분광분석법을 이용한 인도메타신의 정량분석)

  • 김도형;우영아;김효진
    • YAKHAK HOEJI
    • /
    • v.47 no.5
    • /
    • pp.261-265
    • /
    • 2003
  • Near-infrared (NIR) system was used to determine rapidly and simply indomethacin in buffer solution for a dissolution test of tablets and capsules. Indomethacin standards were prepared ranging from 10 to 50 ppm using the mixture of phosphate buffer (pH 7.2) and water (1 : 4). The near-infrared (NIR) transmittance spectra of indomethacin standard solutions were collected by using a quartz cell in 1 mm and 2 mm pathlength. Partial least square regression (PLSR) was explored to develop calibration models over the spectral range 1100∼1700 nm. The model using 1 mm quartz cell was better than that using 2 mm quartz cell. The PLSR models developed gave standard error of prediction (SEP) of 0.858 ppm. In order to validate the developed calibration model, routine analysis was performed using another standard solutions. The NIR routine analysis showed good correlation with actual values. Standard error of prediction (SEP) is 1.414 ppm for 7 indomethacin samples in routine analysis and its error was permeable in the regulation of Korean Pharmacopoeia (VII). These results show the potential use of the real time monitoring for indomethacin during a dissolution test.

A Study on the Voltage Stability Direct Analysis reflecting Load Increase Pattern (부하의 증가 패턴을 고려한 전압 안정도 직접 해석에 관한 연구)

  • Moon, Y.H.;Choi, D.K.;Roh, T.H.;Lee, E.H.
    • Proceedings of the KIEE Conference
    • /
    • 1996.11a
    • /
    • pp.80-83
    • /
    • 1996
  • This paper develops a method for reliably estimating an UEP(Unstable Equilibrium Point) which is located in the direction of SEP(Stable Equilibrium Point)'s moving as system load is getting heavy. As power systems are getting loaded heavily, the SEP which is an operable solution, and the UEP which is occurring voltage collapse, are moving toward each other linearly. The estimated UEP is used as a good initial guess for the real UEP. The proposed method is tested by 3 bus system and Stagg 5 bus system. It is demonstrated that the proposed method is very useful for assessing system voltage stability in the case of heavy loaded power system. The result solutions are often used in conjunction with energy methods and the stability margin.

  • PDF

Application of Variable Selection for Prediction of Target Concentration

  • 김선우;김연주;김종원;윤길원
    • Bulletin of the Korean Chemical Society
    • /
    • v.20 no.5
    • /
    • pp.525-527
    • /
    • 1999
  • Many types of chemical data tend to be characterized by many measured variables on each of a few observations. In this situation, target concentration can be predicted using multivariate statistical modeling. However, it is necessary to use a few variables considering size and cost of instrumentation, for an example, for development of a portable biomedical instrument. This study presents, with a spectral data set of total hemoglobin in whole blood, the possibility that modeling using only a few variables can improve predictability compared to modeling using all of the variables. Predictability from the model using three wavelengths selected from all possible regression method was improved, compared to the model using whole spectra (whole spectra: SEP = 0.4 g/dL, 3-wavelengths: SEP=0.3 g/dL). It appears that the proper selection of variables can be more effective than using whole spectra for determining the hemoglobin concentration in whole blood.

유한요소법에 의한 철근콘크리트 부재의 거동해석

  • 이재홍
    • Computational Structural Engineering
    • /
    • v.9 no.4
    • /
    • pp.30-34
    • /
    • 1996
  • 본문에서는 유한요소법에 의한 철근콘크리트 구조해석에 관한 지난 20여년간의 연구현황에 대해 일리노이대학의 Schnobrich 교수가 쓴 글 (Behavior of Reinforced Concrete Members by Finite Element, APCOM, Sep. 16, 1996, Korea)의 일부를 번역하여 소개한다.

  • PDF

A Single-End-Point DTW Algorithm for Keyword Spotting (핵심어 검출을 위한 단일 끝점 DTW알고리즘)

  • 최용선;오상훈;이수영
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.41 no.3
    • /
    • pp.209-219
    • /
    • 2004
  • In order to implement a real time hardware for keyword spotting, we propose a Single-End-Point DTW(SEP-DTW) algorithm which is simple and less complex for computation. The SEP-DTW algorithm only needs a single end point which enables efficient applications, and it has a small wont of computations because the global search area is divided into successive local search areas. Also, we adopt new local constraints and a new distance measure for a better performance of the SEP-DTW algorithm. Besides, we make a normalization of feature same vectors so that they have the same variance in each frequency bin, and each frame has the same energy levels. To construct several reference patterns for each keyword, we use a clustering algorithm for all training patterns, and mean vectors in every cluster are taken as reference patterns. In order to detect a key word for input streams of speech, we measure the distances between reference patterns and input pattern, and we make a decision whether the distances are smaller than a pre-defined threshold value. With isolated speech recognition and keyword spotting experiments, we verify that the proposed algorithm has a better performance than other methods.

Effects on Nociceptive Neuron Excitability by application of Electroacupuncture and Meloxicam gel in Rat with Inflammation (염증유발 백서에서 전침자극과 Meloxicam gel 적용이 유해성굴곡반사 및 체성감각유발전위에 미치는 효과)

  • Kim, Young-Pil;Lee, Jeong-Woo;Seo, Sam-Ki;Yoon, Se-Won;Yoon, Hee-Jong;Kim, Tae-You
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.5 no.1
    • /
    • pp.45-58
    • /
    • 2007
  • This study aims to examine the effects on nociceptive neuron excitability by application of electroacupuncture and Meloxicam gel in rat with inflammation. It used 24 rats for experiment, divided them into control group, electroacupuncture group(EA group), Meloxicam group(ME group), combination of electroacupuncture with Meloxicam group(EA+ME group), caused hyperalgesia by injecting ${\lambda}$-carrageenan into hindpaw and conducted treatment three times for experimental period. Noxious flexion withdrawal reflex(NFR) and somatosensory evoked potential(SEP) were measured immediately after induction, at 24 hours, 48 hours and 72 hours after induction. Change of NFR(reaction time, RMS) showed no significant differences among EA group, Meloxicam group, and EA+Meloxicam group, but all treatment groups showed significant differences compared to control group from 48 hours. In NFR threshold, there were significant differences between EA+Meloxicam and other groups. In SEP amplitude, there were significant differences between EA+Meloxicam and control group from 48 hours. This study showed that EA+Meloxicam gel had an effect on nociceptive neurone excitability. Therefore, it is considered that appropriate combination of anti-inflammatory drug with electroacupuncture for pain control will be very desirable.

  • PDF

Involvement of Amino Acids Flanking Glu7.32 of the Gonadotropin-releasing Hormone Receptor in the Selectivity of Antagonists

  • Wang, Chengbing;Oh, Da Young;Maiti, Kaushik;Kwon, Hyuk Bang;Cheon, Jun;Hwang, Jong-Ik;Seong, Jae Young
    • Molecules and Cells
    • /
    • v.25 no.1
    • /
    • pp.91-98
    • /
    • 2008
  • The Glu/$Asp^{7.32}$ residue in extracellular loop 3 of the mammalian type-I gonadotropin-releasing hormone receptor (GnRHR) interacts with $Arg^8$ of GnRH-I, conferring preferential ligand selectivity for GnRH-I over GnRH-II. Previously, we demonstrated that the residues (Ser and Pro) flanking Glu/$Asp^{7.32}$ also play a role in the differential agonist selectivity of mammalian and non-mammalian GnRHRs. In this study, we examined the differential antagonist selectivity of wild type and mutant GnRHRs in which the Ser and Pro residues were changed. Cetrorelix, a GnRH-I antagonist, and Trptorelix-2, a GnRH-II antagonist, exhibited high selectivity for mammalian type-I and non-mammalian GnRHRs, respectively. The inhibitory activities of the antagonists were dependent on agonist concentration and subtype. Rat GnRHR in which the Ser-Glu-Pro (SEP) motif was changed to Pro-Glu-Val (PEV) or Pro-Glu-Ser (PES) had increased sensitivity to Trptorelix-2 but decreased sensitivity to Cetrorelix. Mutant bullfrog GnRHR-1 with the SEP motif had the reverse antagonist selectivity, with reduced sensitivity to Trptorelix-2 but increased sensitivity to Cetrorelix. These findings indicate that the residues flanking $Glu^{7.32}$ are important for antagonist as well as agonist selectivity.

Detection and Quantitation of Residual Antibiotics and Antibacterial Agents in Foods

  • Ryu, Jae-Chun;Seo, Ja-Won;Song, Yun-Seon;Park, Jong-Sei
    • Journal of Food Hygiene and Safety
    • /
    • v.5 no.3
    • /
    • pp.159-164
    • /
    • 1990
  • To detect and quantitation residual antibiotics and antibacterial agents in meats, we performed a biological assay employing the three microorganisms Bacillus subtilis ATCC 6633, Micrococcus luteus ATCC 9341, and Bacillus cereus var. mycoides ATCC 11778 for the screening purpose and developed a Gas Chromatography-mass Spectrometry(GC/MS) analysis for the confirmation and quantiation. In the biological assay (paper disk method), three test solution are used depending on the character of the residual antibiotics and antibacterial agents, follow by a simple clean up procedure which includes homogenization with Mcilvaine buffer, defatting with includes homogenization with Mcilvaine buffer, defatting with hexane, extraction with chloroform, clean-up by Sep-Pak $C_{18}$ and Bakerbond SPE carboxylic acid column. The chloroform layer is used for the analysis of sulfa agents. macrolides antibiotics and antibacterial agents, Adsorbed materials in the Sep-Pak $C_{18}$ were also employed for th analysis of penicillins and tetracyclines. Effluents from the Sep-Pak $C_{18}$ were cleaned-up one more by Bakerbond 10 SPE COOH column and employed for the analysis of aminoglycosides. In the instrumental analysis by using the GC/MSD, residual antibiotics and antibacterial agent were quantitated by selected ion monitoring (SIM) mode after derivatization. A simultaneous analysis of six residual antibiotic and antibacterial agent such as oxytetracycline, penicillin, ampicillin, choliraphenicol and thiamphenicol was developed with simple cleanup procedures revealing good recovery and reproducibility. Also, simultaneous detection of macrolides antibiotics such as erythromycin, spiramycin, and oleandomycin was developed after acid hydrolysis due to their large molecular structures. Because of the high reproducibility and selectivity of these two methods, it is very desirable that the combination of the two methods be used in the bioassay for the screening of residual antibiotics and antibacterial agent and that GC/MSD analysis be used for the confirmation and quantitation.

  • PDF

Application of Near Infrared Reflectance Spectroscopy in Quality Evaluation of Domestic Rice (한국산 쌀의 품질측정에 있어서 근적외분광분석법의 응용)

  • Moon, Sung-Sik;Lee, Kyung-Hee;Cho, Rae-Kwang
    • Korean Journal of Food Science and Technology
    • /
    • v.26 no.6
    • /
    • pp.718-725
    • /
    • 1994
  • The applicability of near infrared reflectance spectroscopy (NIRS) to determine moisture, protein, fat and amylose content of domestic rice was studied. The standard error of prediction (SEP) of moisture, protein, fat and amylose in polished rice was 0.014, 0.196, 0.098 and 1.427%, and those SEP of brown rice was 0.12, 1.226, 0.153 and 1.923%, respectively. It is concluded that the NIRS method allowed to detect the content of moisture and protein in rice samples with fair precision comparing conventional analysis, but the accuracy for determining amylose and fat was not acceptable.

  • PDF