• 제목/요약/키워드: SCREEN TEST

검색결과 627건 처리시간 0.021초

Scientific Approach to Fashion Websites Using Eye Trackers

  • Lee, Seunghee;Choi, Jung Won
    • 패션비즈니스
    • /
    • 제24권6호
    • /
    • pp.63-79
    • /
    • 2020
  • This study analyze consumers' unconscious visual attention to color and images of internet shopping malls by using eye-tracking method. Twenty-nine participants, including 15 females and 14 males, participated. The average ages of the male and female participants were 27.3 years and 27.7 years, respectively. Ten images of five layouts (multi-composition images, single-model images, gender-composed images, videos, and moving banner images) of internet shopping malls were shown on an eye-tracker computer screen. Quantitative analyses of the eye-tracking responses were conducted. SPSS was used to analyze the descriptive characteristics and to conduct an independent-sample t-test, along with an ANOVA. The data analysis showed that the image area generally had the shortest time to first fixation (TFF), the longest duration of fixation (DOF), the highest number of fixations (NOF), and the highest numbers of revisits(NOR).Notably, visual attention towards female models was high among various images. The results can be used to improve credibility and design online shopping layout with a scientific evidence that helps consumers through their purchase decisions.

Elimination of Screen-Flickering Phenomenon in Multi-Function Display During Flight of Fixed-Wing Aircraft

  • Kwon, Jung-Hyuk;Kwon, Ik-Hyun;Beak, Jun-Ho;Jang, Geun-Hyung;Lee, Wang-Sang
    • 항공우주시스템공학회지
    • /
    • 제15권2호
    • /
    • pp.45-51
    • /
    • 2021
  • In this study, we aim to eliminate the flickering phenomenon in multi-function display (MFD) units during the flight of fixed-wing aircraft. To execute flight missions effectively, the video signals transmitted to MFDs must provide information accurately and seamlessly. Therefore, a method for addressing the flickering phenomenon-including cause analysis and failure diagnosis-is adopted; specifically, a wiring configuration with a direct connection between the video signal cables and with a short cable length is adopted. The proposed method is experimentally verified using a flight test.

Performance Analysis of GLTF/GLB to Improve 3D Content Rendering Performance

  • Jae Myeong Choi;Ki-Hong Park
    • Journal of Platform Technology
    • /
    • 제11권4호
    • /
    • pp.13-18
    • /
    • 2023
  • 3D content rendering is one of the important factors that give a sense of realism when creating content, and this process takes a lot of time. In this paper, we proposed a method to improve rendering performance by reducing the vast amount of 3D data in the web environment, and conducted a performance test using DEM and 3D model elevation data. As a result of the experiment, the digital elevation model showed faster performance than the Blender-based 3D modeling, but when the screen was moved using OrbitControl, the fps dropped momentarily. In the case of Terrain, if the range is limited to a speed that maintains 24 to 60 fps using frustum culling and LOD techniques, it is considered that a higher quality map can be produced than GeoTIFF.

  • PDF

영상의학과 이동검사 영역의 공간선량 분포에 대한 측정 및 분석 (The Measurement and Analysis by Free Space Scatter Dose Distribution of Diagnostic Radiology Mobile Examination Area)

  • 김성규;손상혁
    • 대한디지털의료영상학회논문지
    • /
    • 제11권1호
    • /
    • pp.5-13
    • /
    • 2009
  • There are several reasons to take X-ray in case of inpatients. Some of them who cannot ambulate or have any risk if move are taken portable X-ray at their wards. Usually, in this case, many other people-patients unneeded X-ray test, family, hospital workers etc-are indirectly exposed to X-ray by scatter ray. For that reason I try to be aware of free space scatter dose accurately and make the point at issue of portable X-ray better in this study. kVp dose meter is used for efficiency management of portable X-ray equipment. Mobile X-ray equipment, ionization chamber, electrometer, solid water phantom are used for measuring of free space scatter dose. First of all the same surroundings condition is made as taken real portable X-ray, inquired amount of X-ray both chest AP and abdomen AP most frequently examined and measured scatter ray distribution of two tests individually changing distance. In the result of measuring horizontal distribution with condition of chest AP it is found that the mAs is decreased as law of distance reverse square but no showed mAs change according to direction. Vertical distribution showed the mAs slightly higher than horizontal distribution but it isnt found out statistical characteristic. In abdomen AP, compare with chest AP, free space scatter dose is as higher as five-hundred times and horizontal, vertical distribution are quite similar to chest AP in result. In portable X-ray test, in order to reduce the secondary exposure by free space scatter dose first, cut down unnecessary portable order the second, set up the specific area at individual ward for the test the third, when moving to a ward for the X-ray test prepare a portable shielding screen. The last, expose about 2m apart from patients if unable to do above three ways.

  • PDF

A Strategy for Multi-target Paths Coverage by Improving Individual Information Sharing

  • Qian, Zhongsheng;Hong, Dafei;Zhao, Chang;Zhu, Jie;Zhu, Zhanggeng
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제13권11호
    • /
    • pp.5464-5488
    • /
    • 2019
  • The multi-population genetic algorithm in multi-target paths coverage has become a top choice for many test engineers. Also, information sharing strategy can improve the efficiency of multi-population genetic algorithm to generate multi-target test data; however, there is still space for some improvements in several aspects, which will affect the effectiveness of covering the target path set. Therefore, a multi-target paths coverage strategy is proposed by improving multi-population genetic algorithm based on individual information sharing among populations. It primarily contains three aspects. Firstly, the behavior of the sub-population covering corresponding target path is improved, so that it can continue to try to cover other sub-paths after covering the current target path, so as to take full advantage of population resources; Secondly, the populations initialized are prioritized according to the matching process, so that those sub-populations with better path coverage rate are executed firstly. Thirdly, for difficultly-covered paths, the individual chromosome features which can cover the difficultly-covered paths are extracted by utilizing the data generated, so as to screen those individuals who can cover the difficultly-covered paths. In the experiments, several benchmark programs were employed to verify the accuracy of the method from different aspects and also compare with similar methods. The experimental results show that it takes less time to cover target paths by our approach than the similar ones, and achieves more efficient test case generation process. Finally, a plug-in prototype is given to implement the approach proposed.

Cross Validation of Attention-Deficit/Hyperactivity Disorder-After School Checklist

  • Lee, Sukhyun;Kim, Bongseog;Yoo, Hanik K.;Huh, Hannah;Roh, Jaewoo
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • 제29권3호
    • /
    • pp.129-136
    • /
    • 2018
  • Objectives: This study aimed to evaluate the efficacy of the attention-deficit/hyperactivity disorder (ADHD)-After School Checklist (ASK) by comparing the results of the Comprehensive Attention Test (CAT) and Clinical Global Impression-Severity (CGI-S) Scale and then by calculating the area under the receiver operating characteristic (ROC) curve. Methods: We performed correlation analyses on the ASK and CAT results and then the ASK and CGI-S results. We created a ROC curve and evaluated performance on the ASK as a diagnostic tool. We then analyzed the test results of 1348 subjects (male 56.8%), including 1201 subjects in the general population and 147 ADHD subjects, aged 6-15 years, from kindergarten to middle school in Seoul and Gyeonggi province, South Korea. Results: According to the correlation analyses, ASK scores and the Attention Quotient (AQ) of CAT scores showed a significant correlation of -0.20--0.29 (p<0.05). The t-test between ADHD scores and CGI-S also showed a significant correlation (t=-2.55, p<0.05). The area under the ROC curve was calculated as 0.81, indicating good efficacy of the ASK, and the cut-off score was calculated as 15.5. Conclusion: The ASK can be used as a valid tool not only to evaluate functional impairment of ADHD children and adolescents but also to screen ADHD.

분광타원해석기를 이용한 자외선 차단제의 평가방법 연구 (Study on the Sun Screen Test Method using Elipsometer)

  • 김준우;이종수;이지혜;정석진
    • 대한화장품학회지
    • /
    • 제37권2호
    • /
    • pp.137-141
    • /
    • 2011
  • 자외선 차단제는 자외선의 흡수 기능을 갖는 유기 계열과 반사 기능을 갖는 무기계로 구분된다. 이들은 SPF지수로 평가되는데 in-vivo 실험은 높은 비용과 시간이 오래 걸리는 단점이 있어 in-vitro 평가가 연구에 많이 이용된다. 하지만 in-vitro 평가로 사용되는 SPF 평가 장치는 재현성이 매우 낮아 값에 대한 신뢰가 매우 어렵다. 또한, UV-vis spectrometer를 이용한 분석은 재현성은 높지만 투과/흡수/반사의 구분된 결과를 구하기 어려운 단점이 있다. 본 연구에서 제시하는 elipsometer는 높은 재현성과 투과/흡수/반사의 구분된 결과, 다양한 각도에서의 평가의 장점이 있어 자외선 차단제 평가에 매우 유용하다. 이를 위해 상업용 자외선 차단제를 다양한 방법으로 평가하여 elipsometer를 이용한 방법의 타당성을 알아보았다.

열전소자 원리를 이용한 부품 Tester용 온도공급 장치 연구 (메모리 Device Tester용 온도제어장치 도입을 위한 연구) (A Study for Adopting the Temperature Control Unit on Memory Device Tester Based on Principle of Thermoelectric Semiconductor)

  • 김선주;홍철호;신동욱;서승범;이무재
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 B
    • /
    • pp.414-416
    • /
    • 2003
  • 메모리 제품의 사용 환경은 점차적으로 High Speed/High Density화됨에 따라 현 Comp. Test 환경으로 Field 환경을 모두 수용하기가 어려워지고 있다. 따라서, Component Level에서 다양한 실장 System을 이용한 Screen 방법이 요구 되고 있다. 다양한 환경에서 Test를 실시하기 위해서 필수 불가결한 조건은 온도(Temperature)를 자동으로 제어(Control)할 수 있는 기능이 필요하게 되었다. 이에, 현재 사용하고 있는 방법은 Chamber나 히터를 이용하고 있으나 온도 제어가 보다 용이하고 정밀한 기능이 요구됨에 따라 열전반도체(Thermoelectric semiconductor)원리를 이용한 온도 제어 장치 도입을 위한 연구가 진행되었다. 본 논문에서는 그 개발 현황 및 평가 결과를 근거로 신규 Component실장 Tester에 효율적으로 도입 적용 가능함을 제시 하고자 한다. 또한, 향후 기타 Tester 및 산업용 설비 등에 까지 확대적용 가능함으로써 전자부품(메모리)의 품질 향상 및 설비투자 Cost절감 효과가 기대 된다.

  • PDF

기계학습을 이용한 로봇 관절부 고장진단에 대한 연구 (Study on the Failure Diagnosis of Robot Joints Using Machine Learning)

  • 김미진;구교문;심재홍;김효영;김기현
    • 반도체디스플레이기술학회지
    • /
    • 제22권4호
    • /
    • pp.113-118
    • /
    • 2023
  • Maintenance of semiconductor equipment processes is crucial for the continuous growth of the semiconductor market. The process must always be upheld in optimal condition to ensure a smooth supply of numerous parts. Additionally, it is imperative to monitor the status of the robots that play a central role in the process. Just as many senses of organs judge a person's body condition, robots also have numerous sensors that play a role, and like human joints, they can detect the condition first in the joints, which are the driving parts of the robot. Therefore, a normal state test bed and an abnormal state test bed using an aging reducer were constructed by simulating the joint, which is the driving part of the robot. Various sensors such as vibration, torque, encoder, and temperature were attached to accurately diagnose the robot's failure, and the test bed was built with an integrated system to collect and control data simultaneously in real-time. After configuring the user screen and building a database based on the collected data, the characteristic values of normal and abnormal data were analyzed, and machine learning was performed using the KNN (K-Nearest Neighbors) machine learning algorithm. This approach yielded an impressive 94% accuracy in failure diagnosis, underscoring the reliability of both the test bed and the data it produced.

  • PDF

Inhibin-A를 추가한 Quad Test의 한국인 산모의 임신주수별 Median치에 대한 평가 (Evaluation of Gestational Age Median Value by Use of the Quad Test with Dimeric Inhibin A for Korea Pregnant Women)

  • 유자영;최삼규;조영숙;황도영
    • 대한임상검사과학회지
    • /
    • 제37권1호
    • /
    • pp.56-60
    • /
    • 2005
  • Human chorionic gonadotrophin (hCG) and unconjugated estriol (uE3) were added to AFP to make what is commonly known as the Triple test. The Triple test combines results from these three tests and has been a standard screening procedure for several years. Recent studies have demonstrated the usefulness of adding inhibin-A to Down's syndrome risk assessment. The Quad test adds dimeric Inhibin-A (DIA) to the three other markers and uses the same computer program to calculate risk factors. Testing was performed between 14 and 21 weeks of gestation. Sample size were 648 samples and period of study was from 1, July, 2004 to 30, September, 2004. Used analytical methods for AFP, hCG and uE3 were radioimmunoassay (RIA) and dimeric inhibin A was enzyme-linked immunosorbent assay (ELISA). Adding dimeric inhibin-A as a fourth marker to the standard triple test increases the detection rate from 62 % to 75 % with a false-positive rate of 5%. The DIA based Quad test has been shown to be the most effective second trimester screening test for Down's syndrome suitable for routine use. Increased DIA values are observed during normal pregnancy where a bimodal pattern response is seen. Values increase during the first trimester, decline after 14 weeks, and re-ascend between 17-25 weeks. Values for DIA may be additionally elevated during a Down's syndrome pregnancy. Dimeric inhibin A is a glycoprotein hormone made by the ovary and placenta. DIA levels are twice as high in Down's syndrome pregnancies. AFP, hCG, and uE3 levels vary with gestational age, and incorrect gestational dating will influence results. DIA levels do not vary substantially with gestational age, resulting in greater screening accuracy. Although the Quad test is an improvement over the Triple test, it is important to underscore the fact that a positive test on both should be done. Most women who initially screen positive will be found to be carrying normal babies when amniocentesis and definitive diagnostic chromosome analysis are done.

  • PDF