• Title/Summary/Keyword: SCALE ANNULUS

Search Result 7, Processing Time 0.02 seconds

Simulated Experiments on High Pressure Melt Ejection in the Reactor Cavity During Severe Accident (원자로 가상사고시(노심) 용융물 고압 분출 모의 실험 연구)

  • Jeong, Han-Won;Kim, Do-Hyeong;Lee, Gyu-Jeong;Kim, Sang-Baek;Park, Rae-Jun;Kim, Hui-Dong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.11
    • /
    • pp.1447-1456
    • /
    • 2000
  • Simulated experiments of high pressure melt ejection(HPME) are performed to measure the released fraction of corium simulant from the French type PWR cavity. The experiments are carried out on a 1/20th linear scaled model of the Ulchin 1&2 cavity. Water or woods metal and nitrogen is used as simulant of molten corium and steam, respectively. Experimental parameters are water mass, annulus area and breach size. It is shown that only breach size effects is very important while the mass and the annulus area do not affect the released fraction. It is found that the liquid film transport is much more dominant mechanism than the entrainment droplet transport, especially in linear scale down simulated HPME experiment.

Direct ECC Bypass Phenomena in the MIDAS Test Facility During LBLOCA Reflood Phase

  • B.J. Yun;T.S. Kwon;D.J. Euh;I.C. Chu;Park, W.M.;C.H. Song;Park, J.K.
    • Nuclear Engineering and Technology
    • /
    • v.34 no.5
    • /
    • pp.421-432
    • /
    • 2002
  • As one of the advanced design features of the APR1400, direct vessel injection (DVI) system is being considered instead of conventional cold leg injection (CLI) system. It is known that the DVI system greatly enhances the reliability of the emergency core cooling (ECC) system. However, there is still a dispute on its performance in terms of water delivery to the reactor core during the reflood phase of a large-break loss-of-coolant accident (LOCA). Thus, experimental validation is under progress. In this paper, test results of direct ECC bypass performed in the steam-water test facility tailed MIDAS (Multi-dimensional Investigation in Downcomer Annulus Simulation) are presented. The test condition is determined, based on the preliminary analysis of TRAC code, by applying the ‘modified linear scaling method’with the l/4.93 length scale . From the tests, ECC direct bypass fraction, steam condensation rate and information on the flow distribution in the upper annulus downcomer region are obtained.

Estimation on Population Ecological Characteristics of Crucian Carp, Carassius auratus in the Mid-Upper System of the Seomjin River (섬진강 중.상류 수계에서 붕어 개체군의 생태학적 특성치 추정)

  • Jang, Sung-Hyun;Ryu, Hui-Seong;Lee, Jung-Ho
    • Korean Journal of Environment and Ecology
    • /
    • v.25 no.3
    • /
    • pp.318-326
    • /
    • 2011
  • The population ecological characteristics of the Crucian carp, Carassius auratus, were determined in order to estimate stock of the mid-upper system of the Seomjin River. The fish ranged in size from 95 to 288mm total length. The age was determined by counting the scale annulus. The scales displayed clear annulus that were used to estimate the age. The oldest fish observed in this study was 5 years old. Age-2 fishes were the most numerous in the sample(n=38), followed in frequency be age-3(n=22). Marginal index analysis validated the formation of a single annulus per year. The relationship between body length and body weight was BW = $0.0038BL^{3.73}$($R^2$=0.96) (p<0.01). The relationship between the scale radius and body length was BL = 2.362R+2.76($R^2$=0.89). The von Bertalanffy growth parameters estimated from a non-linear regression method were $L_{\infty}$=33.2 cm, $W_{\infty}$=1,798.4 g, $K=0.20year^{-1}$ and $t_0$=-0.51year. Therefore, Growth in length of the fish was expressed by the von Bertalanffy's growth equation as $L_t=33.23$($1-e^{-0.20(t+0.51)}$)($R^2$=0.98). The annual survival rate was estimated to be 0.427year$^{-1}$. The instantaneous coefficient of natural mortality of estimated from the Zhang and Megrey method was $0.784year^{-1}$, and instantaneous coefficient of fishing mortality was calculated $0.067year^{-1}$. From the estimates of survival rate, the instantaneous coefficient of total mortality was estimated to be $0.851year^{-1}$.

Characterization of flow properties of pharmaceutical pellets in draft tube conical spout-fluid beds

  • Foroughi-Dahr, Mohammad;Sotudeh-Gharebagh, Rahmat;Mostoufi, Navid
    • Journal of Industrial and Engineering Chemistry
    • /
    • v.68
    • /
    • pp.274-281
    • /
    • 2018
  • Experimental studies of the hydrodynamic performance of the draft tube conical spout-fluid bed (DCSF) were conducted using pharmaceutical pellets. The experiments were carried out in a DCSF consisted of two sections: (a) a conical section with the cross section of $120mm{\times}250mm$ and the height of 270 mm, (b) a cylindrical section with the diameter of 250 mm and the height of 600 mm. The flow characteristics of solids were investigated with a high speed camera and a pezoresistive absolute pressure transducer simultaneously. These characteristics revealed different flow regimes in the DCSF: packed bed at low gas velocities, fluidized bed in draft tube at higher gas velocities until minimum spouting, and spouted bed. The stable spouting was identified by the presence of two dominant frequencies of the power spectrum density of pressure fluctuation signature: (i) the frequency band 6-9 Hz and (ii) the frequency band 12-15 Hz. The pressure drops across the draft tube as well as the annulus measured in order to better recognize the flow structure in the DCSF. It was observed that the pressure drop across the draft tube, the pressure drop across the annulus, and the minimum spouting velocity increase with the increase in the height of draft tube and distance of the entrainment zone, but with the decrease in the distributor hole pitch. Finally, this study provided novel insight into the hydrodynamic of DCSF, particularly minimum spouting and stable spouting in the DCSF which contains valuable information for process design and scale-up of spouted bed equipment.

Characteristics of the Onset of Flooding for Countercurrent Air-Water Flow in Vertical Annuli with a Direct Injection Mode (수직 환상관내 반류 공기-물 유동에서 직접분사방식에 따른 플러딩 시작점 특성)

  • Lee, S.C.;Shin, I.H.;Lee, S.M.;Chung, M.;Kim, D.S.;Chang, W.P.
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.1
    • /
    • pp.266-274
    • /
    • 1996
  • An experimental work was conducted to investigate the characteristics of the onset of flooding in vertical annuli with a direct injection mode using air and water. The onset of flooding was determined by means of pressure drop measurement while the air velocity was increased gradually under fixed liquid flow rates. Data of the onset of flooding were collected for various combinations of the tube size and the nozzle number. A theoretical analysis of the onset of flooding was also performed based on an envelope theory. The result shows that the onset of flooding in small-scale annuli can be predicted relatively well by the theory. A modified Wallis parameter was used to investigate the scaling effect of flooding phenomena in the annuli, indicating a relatively reasonable result. The number of nozzle has no effect on the flooding velocity when liquid was injected through 2, 3, 4 and 6 nozzles but the initiation of flooding was significantly expedited when 12 nozzles were employed for liquid injection.

Efficacy of transforaminal laser annuloplasty versus intradiscal radiofrequency annuloplasty for discogenic low back pain

  • Park, Chan Hong;Lee, Kyoung Kyu;Lee, Sang Ho
    • The Korean Journal of Pain
    • /
    • v.32 no.2
    • /
    • pp.113-119
    • /
    • 2019
  • Background: Discogenic pain is a common cause of disability and is assumed to be a major cause of non-specific low back pain. Various treatment methods have been used for the treatment of discogenic pain. This study was conducted to compare the therapeutic success of radiofrequency (an intradiscal procedure) and laser annuloplasty (both an intradiscal and extradiscal procedure). Methods: This single-center study included 80 patients and followed them for 6 months. Transforaminal laser annuloplasty (TFLA, 37 patients) or intradiscal radiofrequency annuloplasty (IDRA, 43 patients) was performed. The main outcomes included pain scores, determined by the numeric rating scale (NRS), and Oswestry disability index (ODI), at pre-treatment and at post-treatment months 1 and 6. Results: The patients were grouped according to procedure. In all procedures, NRS and ODI scores were significantly decreased over time. Mean post-treatment pain scores at months 1 and 6 were significantly lower (P < 0.01) in both groups, and between-group differences were not significant. The ODI score was also significantly decreased compared with baseline. Among patients undergoing TFLA, 70.3% (n = 26) reported pain relief (NRS scores < 50% of baseline) at post-treatment 6 months, vs. 58.1% (n = 25) of those undergoing IDRA. There were no statistically significant differences between the groups in ODI reduction of > 40%. Conclusions: Our results indicate that annuloplasty is a reasonable treatment option for carefully selected patients with lower back and radicular pain of discogenic origin, and TFLA might be superior to IDRA in patients with discogenic low back pain.

Analysis of Plugging Effect for Open-ended Piles Based on Field Tests (현장시험을 통한 개단말뚝의 폐색효과에 대한 연구)

  • Ko, Jun-Young;Jeong, Sang-Seom
    • Journal of the Korean Geotechnical Society
    • /
    • v.30 no.12
    • /
    • pp.51-61
    • /
    • 2014
  • This paper presents an experimental study of the plugging effect on the capacity of open-ended piles installed in sandy soil. Full-scale tests, including dynamic and static axial-compression load tests, were carried out on three instrumented piles with different diameters (508.0, 711.2 and 914.4 mm). To measure the outer and inner shaft resistances acting on the piles, a double-walled system was utilized with instrumented strain gauges on the outside and inside walls of the pile. The results of field tests show that the inner shaft resistance was mostly mobilized at the location between the pile tip and 18-34% of the total plug length. It was found that the soil plugging in the lower portion has influence on the inner shaft resistance. In addition, it can be also demonstrated that the ratio of inner shaft resistance plus annulus load resistance to total resistance decreased with increasing pile diameters. The results of these tests show that the relationship between the degree of plugging and pile diameter is clearly established. Direct observations of the soil plugs were made and used to quantify both the plug length ratio (PLR) and the incremental filling ratio (IFR). Based on this result, it was found that the N value of the standard penetration test (SPT) is highly correlated with the IFR.