• Title/Summary/Keyword: SCALE

Search Result 46,642, Processing Time 0.056 seconds

Development of a Knowledge Scale of Fall Risk Factors for Community-dwelling Older Adults (재가노인의 낙상위험요인 지식 측정도구 개발)

  • Hong, Chong-Min
    • Korean Journal of Adult Nursing
    • /
    • v.24 no.3
    • /
    • pp.244-252
    • /
    • 2012
  • Purpose: The purpose of the study was to develop a knowledge scale of risk factors for fall among community-dwelling older adults. Further, the validity and reliability of the scale was developed. Methods: A preliminary scale was developed through content validity by five experts and targeted subjects using the CVI (Content Validity Index). Following the establishment of content validity, the scale was used with 359 community-dwelling older adults to further establish both validity and reliability of the scale. Specifically, construct validity using known-group comparison technique, and reliability using Cronbach's ${\alpha}$ were established. Results: After content validity testing, 44 preliminary items were selected. Construct validity was established by known group-comparison, in which scores between the fall and no fall groups were compared. The Cronbach's ${\alpha}$ of the final scale was .83. Conclusion: Reliability and validity of the scale were confirmed. This tool may be used for measuring knowledge of fall risk factor for the community-dwelling older adults.

Performance Evaluation of Scale Mitigation Unit for Heat Exchangers (열교환기에 대한 스케일 완화장치의 성능평가)

  • Mo, Jeong-Ha;Sin, Sang-Cheol;Kim, Gyeong-U
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.9
    • /
    • pp.1149-1156
    • /
    • 2001
  • The objective of the present study is to investigate the performance of electronic scale mitigation unit(ESMU), which reduces the amount of scale in a heat exchanger. The circular tube with diameter of 19mm and plate-and-frame heat exchangers with 20 thermal plates were used for the tests. In order to accelerate the rate of scale in a laboratory test, artificial hard water of 1000ppm(as CaCO$_3$) was recirculated at a flow rate of 5 lpm, 7 lpm, and 9 lpm throughout the tests. The effect of ESMU on the scale thickness and overall heat transfer coefficients was examined. The test results showed that the ESMU could reduce the scale deposits even in the acceleated test.

Subjective Measures of Operator Status in Surface Transportation: h Critical Review and Recommendations for Application (지상 교통에 있어서 운전자 상태의 주관적 척도: 비판적 고찰 및 응용을 위한 제언)

  • Heidi D. Howarth;Sohn, Young-Woo
    • Science of Emotion and Sensibility
    • /
    • v.5 no.4
    • /
    • pp.11-32
    • /
    • 2002
  • This article evaluates the existing subjective measures that have been utilized in surface transportation to assess various aspects of operator status such as fatigue, sleepiness, arousal, mood, etc. Specifically, the representative six subjective instruments - Epworth Sleepiness Scale, Karolinska Sleepiness Scale, Pearson and Byars Fatigue Checklist, Stanford Sleepiness Scale, Stress-Arousal Checklist, and NPRU Mood Scale - are compared and contrasted in terms of reliability, . validity, sensitivity, and appropriateness for application. Recommendations for application of the subjective measures in surface transportation are discussed.

  • PDF

The Comparison of Postural Assesment Scale for Stroke (PASS : 5items-3Level) and Berg Balance Scale (BBS : 7items-3Level) Used for Patients with Stroke (뇌졸중 환자의 Postural Assessment Scale for Stroke (축소형 PASS : 5항목-3점 척도)와 Berg Balance Scale (축소형 BBS : 7항목-3점 척도)의 비교 연구)

  • An, Seung-Heon;Kim, Jae-Hyun;Song, Chang-Ho
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.5 no.1
    • /
    • pp.89-99
    • /
    • 2010
  • Purpose : This study were to examine the test-retest and inter-rater reliability as well as the concurrent validity, and convergent validity of the 2 simplified Postural Assessment Scale for Stroke:5itmes-3Level(PASS:5i-3L) & Berg Balance Scale:7items

Application of the SERVQUAL Scale to Health Care Services (의료서비스에서 SERVQUAL 활용에 대한 고찰)

  • 조우현;이선희;최귀선;문기태
    • Health Policy and Management
    • /
    • v.9 no.4
    • /
    • pp.140-156
    • /
    • 1999
  • The purpose of this article was to review the basic concept of the SERVQUAL scale and to evaluate its usefulness in health care settings. The SERVQUAL scale was developed by Parasuraman et al. in 1988. Its purpose was to provide an instrument for measuring the quality of service that would apply across a broad range of services with minor modifications in the scale. The SERVQUAL scale is based on gap theory, which indicates the difference between consumers' expectations and their assessment of the actual performance of a specific firm. It has five dimensions to define service quality. These dimensions include: (1) tangibles' (2) reliability' (3) responsiveness' (4) assurance' (5) empathy. While the SERVQUAL scale has been tested in a number of health care settings. the findings have been mixed. So. health care marketers should be cautious in their use of the SERVQUAL scale. However, it is rare to find instruments that are as well validated as SERVQUAL appears to be. As well the SERVQUAL scale provides valuable information about the quality of health care service.

  • PDF

Fracture Mechanics Study on Wear Mechanism of Ceramics -Discussions on Experimental Results of Wear Test- (세라믹의 마멸기구에 관한 파괴역학적 연구 -마멸실험 결과의 고찰-)

  • 김석삼;김재호
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.3
    • /
    • pp.636-645
    • /
    • 1990
  • Analytically induced wear mechanism of elastic body under Hertzian contact is applied in acutual wear test of ceramics. There are two types of wear in ceramics, a large scale wear and a small scale wear. The large scale wear is commensurable with Hertzian contact area and the small scale wear with real contact area. Nondimensional parameter, S$_{c}$, is introduced and fully examined to estimate or predict wear rate of ceramics. Ceramic wear for S$_{c}$.leq.0.8 is in small scale wear and for S$_{c}$;geq.1.6 in large scale wear. wear.

High resolution linear scale using collimated LASER (레이저를 이용한 광학식 리니어 스케일의 분해능 향상에 관한 연구)

  • 박윤창;정경민
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.170-174
    • /
    • 1999
  • The main scale of linear scale greatly affects on the precision of displacement measurement. Especially when needing the long range measurement, the length of main scale should be increased accordingly. In this paper, we propose a linear scale that uses laser interference pattern as main scale for long range measurement. The linear scale is similar to Michelson interferometer excepting that the reference mirror is tilted so as to obtain interference fringe pattern and a grating panel is attached on a quadratic photo diodes. Four kinds of grating having phase differences of 0, $\pi$ /4, $\pi$ /2, 3 $\pi$ /4 are arranged on the panel. The experimental results show that signals of - quadratic photo diode, A, B,$\overline{A}$ and $\overline{B}$ are cosine wavelike and successive signals have phase difference of $\pi$/4 each other. So the proposed method can achieve improved measurement resolution.

  • PDF

Construction of a Hydraulic Scale Model for Representing the Field Tracer Experiment in River (하천 현장 실험 재현을 위한 수리모형 장치 제작)

  • Chun, Il Young;Kim, Ki Chul;Lee, Jung Lyul;Suh, Kyung Suk
    • Journal of Radiation Industry
    • /
    • v.2 no.3
    • /
    • pp.155-161
    • /
    • 2008
  • A hydraulic scale model was constructed to investigate the characteristics of flows and pollutant transport in laboratory. The distorted hydraulic scale model by assuming Froude similarity was adopted to represent hydrodynamics and dispersion in a river system. The scale model was composed of water reservoir, slope control part, booster pump, distributing plate and main channel. A constructed scale model will be used to present the overall concentration profiles of tracer and a research will be performed to convert the measured values using a hydraulic scale model to real field scale.

A Study on the Domestic Scale-up Policy Direction through the Analysis of Scale-up Support Policy for Global Startups (글로벌 창업기업 스케일업(Scale-up) 지원 정책 분석을 통한 국내 스케일업 정책 방향에 관한 연구)

  • Hong, Dae Ung;Jun, Byung Hoon
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.14 no.6
    • /
    • pp.11-27
    • /
    • 2019
  • The second venture "boom" diffusion strategy can be confirmed to be focused only on financing investment and finance, including achieving 5 trillion won annually in new venture investments, creating 20 unicorns, activating M&As and creating dynamic recovery markets. Of course, existing studies show that the fund is a very important policy for corporate growth, but various policy support will be needed to effectively scale up. To overcome these limitations, the scale-up support policies already in operation are analyzed by introducing scale-up policies in advanced countries such as the U.S. and Britain. It also aims to analyze domestic scale-up policies to draw up implications for establishing more effective scale-up policies. Academically, we are very lacking in research on scale-up at home and abroad, and we propose suggestions through this comparative study of policy cases to contribute to the promotion of various studies related to the scalability aspects of future research topics related to scale-up.

Study of the Validity Test on the Self-monitoring Scale for Primi-Gravida (초임부를 대상으로 한 자가검색도 척도의 타당도 비교)

  • Lee, Seon-Ah
    • Women's Health Nursing
    • /
    • v.4 no.2
    • /
    • pp.173-186
    • /
    • 1998
  • In this study, both the literary survey as well as empirical research has been executed to test the validity of the scales that measure the construct of self-monitoring scale could not be classified into five factors as Snyder suggested. Many other scholars (Briggs, Cheek and Buss, 1980) suggested 3 different classifications which was accepted by Snyder and Gangestad (1986). John, Cheek and Klohnen (1996) claimed a two-factor classification. As has been discussed, factor analysis is used to prove convergent validity within the factor and discriminant validity between the factors. However, depending on the researchers, many variations in classification of the factors were found and a lack of content and discriminant validity was found in the previous research findings. It is also important to note that Snyder's self-monitoring scale, did not factor-load at over 30 for all 25 items, regardless of how many factors could be classified. According to findings of this study, the self-monitoring scale neither classified as five, three or two factors nor factor loaded as hypothesized. It is also clear that Snyder's self-monitoring scale lack convergent validity as the sub-factors of the scale fail to prove its uni-dimensionality. The A self-monitoring scale not only fail to overcome the problems of Snyder's self-monitoring scale but even lost the attractiveness of the self-monitoring scale. In this study, it was also found that the A self-monitoring scale was not classified as hypothesized in either in a two or three-factor classification. It is, of course, not desirable to use any scale that lacks convergent and discriminant validity even though it has been widely used but also has held a great deal of influence on the field of social psychology. To overcome the shortcomings of Snyder's self-monitoring scale, Lennox and Wolfe(1984) suggested 13 items. This study 1. was dedicated to test the validity and reliability of the scale, in which we found that the data presented in validity as the two factors were classified and loaded as expected. Reliability was also proven by checking Cronbach's alpha for each factor and for the total items. In addition, a confirmatory factor analysis was executed for the 13 items using LISREL 8.12 program to confirm convergent validity in a two-factor classification. The model was fitting and sound ; however, the self-monitoring scale was unfitted and not validated. Thus, it is recommended to use not the original or the abbreviated self-monitoring scale but the 13 items in future studies. It should also be noted that items 7 and 13 should be removed to obtain better uni-dimensionality for the 13 items. These items loaded at over .30, too high for the two factors in the test results of factor analysis. In addition, it is necessary to double-check the cause of two-hold loading at over .30 for the two factors. It could be a problem caused by data or by the scale itself. Therefore, additional studies should follow to better clarify this matter.

  • PDF