• 제목/요약/키워드: SCADA data

검색결과 207건 처리시간 0.027초

Security Issues & Application in Korea SCADA

  • Kim, Hak-Man;Kang, Dong-Joo
    • 조명전기설비학회논문지
    • /
    • 제21권9호
    • /
    • pp.95-100
    • /
    • 2007
  • The importance of communication security is increased in the power industry. The representative communication network of power industry is the SCADA(Supervisory Control and Data Acquisition) systems. The SCADA system has been used for remote measurement and control in the power industry. Recently, many studies of SCADA network security have been carried out around the world. In this paper, we introduce recent security issues in the SCADA network and propose the application of a symmetric encryption method to the Korea SCADA network.

전력감시제어설비(SCADA)의 open system architecture 적용 (The application of open system architecture in power SCADA system)

  • 이용해;문국연;박장범
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.992-995
    • /
    • 1996
  • The major roles of Power SCADA System are continuous monitoring of electrical equipments state, real-time data processing and dispatching. Especially, SCADA system demands fast response time in heavy load condition, high reliability, fault tolerance, expansion capacity for the future. According to developing computer system technology, SCADA system is changing system configuration from centralized processing system to distributed processing system. This paper describes operational benefits, problems and improvement (which is studying in theory) in the application of Open System Architecture SCADA which has been installed since 1994, Seoul regional control center in KEPCO.

  • PDF

안전한 SCADA 통신을 위한 트리 기반의 효율적인 키 관리 구조 (Advanced Key Management Architecture Based on Tree Structure for Secure SCADA Communications)

  • 최동현;이성진;정한재;강동주;김학만;김경신;원동호;김승주
    • 정보처리학회논문지C
    • /
    • 제16C권1호
    • /
    • pp.37-50
    • /
    • 2009
  • SCADA(Supervisory Control and Data Acquisition) 시스템은 국가 기반시설에서 주로 사용되는 제어 시스템이다. 과거 SCADA 시스템은 폐쇄 망에서 운영되어진다는 이유로 보안에 대한 고려 없이 설계되었다. 하지만 기술의 발달로 SCADA 시스템과 공용망과의 연계가 추진되면서 보안에 대한 문제점이 대두 되고 있다. 본 논문에서는 SCADA 시스템의 제약사항과 보안요구사항을 살펴보고, 안전한 SCADA 시스템을 위한 키 관리 구조를 제안한다. 기존에 제안되어있는 SCADA 시스템을 위한 키 관리 방식이 메시지 브로드캐스팅을 지원하지 못하는 반면, 제안하는 방식은 메시지 브로드캐스팅을 지원한다. 또한 제안하는 방식은 성능상의 제약을 가지고 있는 RTU의 계산량을 최소화하기 위해, 상위 노드(SUB-MTU 또는 MTU)에 계산량을 분배하여 RTU의 잠재적인 성능 병목을 해결하였다.

Key Distribution Process for Encryption of SCADA Communication using Game Theory applied Multiagent System

  • Kim, Hak-Man;Kang, Dong-Joo
    • 조명전기설비학회논문지
    • /
    • 제23권11호
    • /
    • pp.34-43
    • /
    • 2009
  • SCADA (Supervisory Control and Data Acquisition) system has been used for remote measurement and control on the critical infrastructures as well as modem industrial facilities. As cyber attacks increase on communication networks, SCADA network has been also exposed to cyber security problems. Especially, SCADA systems of energy industry such as electric power, gas and oil are vulnerable to targeted cyber attack and terrorism Recently, many research efforts to solve the problems have made progress on SCADA network security. In this paper, flexible key distribution concept is proposed for improving the security of SCADA network using Multiagent System (MAS).

TETRA 기반 IEC 61850 SCADA 시스템 구축 (Building IEC 61850 SCADA system based on TETRA)

  • 송병권;정태의
    • 전기전자학회논문지
    • /
    • 제13권3호
    • /
    • pp.87-94
    • /
    • 2009
  • TETRA(TErrestrial Trunked RAdio)는 국내 전력IT무선기간망에 적용된 ETSI(European Telecommunications Standards Institute)가 정한 디지털 주파수공용통신(TRS, Trunked Radio System) 기술로서 공중망 및 기간망에 적용되고 있는 무선통신시스템이다. IEC 61850은 SCADA(Supervisory Control And Data Acquisition) 시스템에서 SAS(Substation Automation System)를 위해 제안된 프로토콜이다. 본 논문에서는 리눅스 운영체제 기반의 IEC 61850 Server와 Client Simulator를 사용하였다. 또한 IEC 61850 Server Simulator와 Client Simulator 간의 TCP/IP 기반의 통신을 TETRA Packet Data Service 기반의 통신으로 변환하는 다기능 게이트웨이를 개발하여 TETRA 기반 IEC 61850 SCADA 시스템을 구축하였다.

  • PDF

영상정보 통합형 전기설비 감시시스템 개발 연구 (A study on development of multimedia SCADA system for electric facility)

  • 이원태;이재조;정영경;김관호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 G
    • /
    • pp.2445-2447
    • /
    • 1998
  • For increasing the quality of SCADA system, the application of image information is demanded from typical SCADA system based on data information. Until now, the remote control and monitoring systems combine data information but now gradually have trends to combine voice, data and image information. So multimedia technology is applied to realize new SCADA system. Depends on these requires, we apply new concepts of communication network and multimedia technology to the SCADA system for electric facility. In this paper, we aim at developing multi media supervisory control and data acquisition system based on data and image information, which used electric power system and security system.

  • PDF

한전 변전자동차시스템과 배전자동화시스템의 자료연계방안에 관한 연구 (A Study on the data link between SCADA and DAS)

  • 고상천;김용팔
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 G
    • /
    • pp.2393-2395
    • /
    • 1998
  • Today it is hard to imagine the operation of power network and its facilities without the control systems such as EMS/SCADA/DAS. In KEPCO, data links to the upper layer of control system (SCABA) is required to launched DAS project lately, in terms of the needs of saving cost for the data gathering facilities (RTU) in the substation that previously equipped SCADA RTU. In this Paper we researched the circumstance of the KEPCO SCADA systems for data link and present the scheme of the data link between DAS and SCADA.

  • PDF

SCADA 시스템의 보안성 평가를 위한 테스트베드 구성 (A SCADA Testbed Implementation Architecture for Security Assessment)

  • 이종주;김석주;강동주
    • 조명전기설비학회논문지
    • /
    • 제24권4호
    • /
    • pp.50-56
    • /
    • 2010
  • 집중 원격감시 제어 또는 감시제어 데이터 수집 시스템인 SCADA(Supervisory Control And Data Acquisition) 는 기존의 국지적인 산업용 네트워크 기반의 제어시스템이 정보통신 기술의 발전으로 광역화되면서 전력, 가스, 상하수도, 교통시스템 등 주요 기반시설에 적용되어 분산제어와 공정제어 시스템으로 사용되고 있다. SCADA 시스템의 중요성과 사고시 미치는 파급효과를 고려하여 구성 장치 및 통신 설비들에 대한 사이버 보안(cyber security) 인식이 점차 높아지고 있으며, SCADA 시스템의 취약성 분석과 보안성 확보에 대한 연구가 이루어지고 있다. 본 논문에서는 현장에서 운용중인 상용 SCADA 시스템의 계층구조와 통신 사양 및 규약을 고려하여 보안성 평가를 위한 테스트베드를 제안하고자 한다. 특히 계측 제어 명령을 수행하는 RTU, IED와 같은 단말 장치의 직렬통신 구간에서 보안성 평가를 수행하기 위한 물리적 접속과 평가 절차를 제시하였다.

직접연계방법에 의한 DAS-SCADA 연계 연구 (A Study on the Interface between DAS and SCADA by using Direct Method)

  • 박소영;신창훈
    • 한국산학기술학회논문지
    • /
    • 제9권5호
    • /
    • pp.1154-1163
    • /
    • 2008
  • 배전자동화시스템(DAS:Distribution Automation System)과 변전자동화시스템(SCADA:Supervisory Control And Data Acquisition)은 전력계통을 컴퓨터와 통신기술을 이용하여 운용하는 주된 시스템으로, 현재 독립적으로 운영됨으로 인해 신속하게 처리되어야 하는 고장처리 및 활선작업처리가 지연되는 등의 문제점이 제기되어왔고, 이에 따라 DAS-SCADA 연계 연구가 요구되었다. 연계방법으로 직접연계, 웹연계, DAS 기능부 전력량계를 이용한 연계가 2005년 11월부터 2007년 12월까지 한전 사업소에서 시범 운영되었고, 그 결과 투자비용 면에서 직접연계방법이 웹연계 방법에 비해 약 1.3배 높지만 다양한 변전소 운전정보 전달의 신속성, 제어기능 우수 등의 타당성이 입증됨으로써 직접연계방법에 의한 DAS-SCADA 연계가 2010년까지 한전 사업소에 전국적으로 확대 적용될 계획이다. 시범 운영시 제기된 문제점을 개선하기 위해 변전소 개체별 통신 방법을 이용한 데이터 연계방안으로 개선하여 연계DB 자동구축 기능 및 연계시스템 진단/Log 기능을 개발하였다. 연계데이터 포인트와 통신데이터 종류를 정의하고, SCADA HMI 프로그램을 개발하여 변전소 단선도 자동생성 기능, 변전소 단선도 수동편집 기능, SCADA 감시 제어기능 및 이력관리 기능을 개발하였다. DAS-SCADA 연계시 정전건당 평균시간을 약 33% 단축하여 전력공급 신뢰도를 향상하고, 배전 계통운영센터와 변전소간 활선작업 처리절차 축소로 전력계통 효율적 운영에 기여하고, 나아가 고장시 부하절체 자동처리로 완전한 배전자동화 실현 및 해외 수출화 사업에도 크게 기여할 것으로 기대된다.

Securing Internet-based SCADA Wireless Component Communication

  • Robles, Rosslin John;Kim, Tai-hoon
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제4권1호
    • /
    • pp.3-7
    • /
    • 2012
  • Traditionally SCADA is connected only in a limited private network. With new technology and facilities, there are also demands of connecting SCADA though the internet. The internet SCADA facility has brought a lot of advantages in terms of control, data viewing and generation. Aside from connecting SCADA to the internet, there are also operators who want to connect their system wirelessly. This can save budget for communication lines. Along with the advantages it brings, are security issues regarding wireless internet SCADA. In this paper, we discuss internet SCADA, its connection through wireless communication and the security issues surrounding it. To answer the security issues, a symmetric-key encryption for internet SCADA is proposed.