• Title/Summary/Keyword: SCADA System

Search Result 291, Processing Time 0.039 seconds

Calculation of Network Analysis and Fault Decision using Equality Constraint Condition with MATLAB (등호제약조건을 이용한 계통 해석 및 고장판단 계산 구현)

  • Yang, Min-Uk;Kim, Kern-Joong;Hwang, In-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.11
    • /
    • pp.2101-2106
    • /
    • 2009
  • The power system state estimation and prediction are very important for operation. Because that accidents of the Power system are the cause that many devices and etc are damaged. Currently, almost every power systems have 2nd,3rd back-upsystem for prevention of accident. But prevention of accident by miss-operation, due to operator or miss data, has not acounter plan. Because, we need to estimate the power system for correcting miss data and preventing miss operation by operator. We suggest algorithm for integrity of power system network data.

Optimal WAMS Configuration in Nordic Power System

  • Mohamed A.M. Hassan;Omar H. Abdalla;Hady H. Fayek;Aisha H.A. Hashim;Siti Fauziah Toha
    • International Journal of Computer Science & Network Security
    • /
    • v.23 no.3
    • /
    • pp.130-138
    • /
    • 2023
  • The Smart grids are considered as multi-disciplinary power systems where the communication networks are highly employed. This paper presents optimal wide area measurement system (WAMS) configuration in Nordic power system. The transition from SCADA to WAMS becomes now trend in all power systems to ensure higher reliability and data visibility. The optimization applied in this research considered the geographical regions of the Nordic power system. The research considered all the devices of WAMS namely phasor measurement units (PMUs), phasor data concentrators (PDCs) and communication links. The study also presents two scenarios for optimal WAMS namely base case and N-1 contingency as different operating conditions. The result of this research presents technical and financial results for WAMS configuration in a real power system. The optimization results are performed using MATLAB 2017a software application.

The study of linkage between systems to make the database of distribution automation system (대규모 배전자동화 시스템의 데이터베이스 구축을 위한 시스템 연계 연구)

  • Ha, B.N.;Kang, M.H.;Cho, N.H.;Jeong, C.S.;Kim, J.S.;Lee, H.H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.419-421
    • /
    • 2001
  • The large distribution automation system for metropolitan city was developed in KEPCO just recently. This system has many functions for remote control and data acquisition, and it will be linked the other computer aided system such as NDIS(new distribution automation system) and SCADA(supervisory control and data acquisition) to construct the database of DAS(distribution automation system).

  • PDF

Establishment of Cyber Security Countermeasures amenable to the Structure of Power Monitoring & Control Systems (전력계통 제어시스템 구조에 따른 사이버 보안대책 수립)

  • Woo, Pil Sung;Kim, Balho H.
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.12
    • /
    • pp.1577-1586
    • /
    • 2018
  • The emergence of the Smart Grid is an integrated solution for the next generation power system that combines IT technology in the power system to create optimal energy utilization and various services. However, these convergence technologies (power systems and information communications) are not only improving the related technologies but also producing various problems especially exposure to cyber risk. In particular, the intelligent power grid has security vulnerabilities through real-time information sharing among various organically linked systems, and it is more complicated than the cyber risk problem in the existing IT field and is directly connected to national disaster accidents. Therefore, in order to construct and operate a more stable smart grid, this paper analyzes the system of power system control system in Korea, and proposes a cyber security element definition and a countermeasure establishment method of power monitoring & control systems based on security standards of smart grid (No. SPS-SGSF-121-1-1).

IEC 61970 CIM based Study on the application of model for Wide Area Monitoring And Control System (IEC 61970 CIM을 기반으로 한 Wide Area Monitoring And Control system 모델 적용 연구)

  • Cho, Jun-Hee;Oh, Young-Suk;Choi, Mi-Hwa;Shin, Seung-Hee;Kim, Ji-Young
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.178-179
    • /
    • 2011
  • The exchange of information with legacy systems is a main issue in the era of SMARTGRID. Because WAMAC(Wide Area Monitoring and Control) system has monitoring function, as well as control function, it is very necessary for WAMAC to exchange data and information with SCADA(Supervisory Control and Data Acquisition) / EMS(Energy Management System). IEC 61970 CIM(Common Information Model) is an abstract model that represents all the major objects in an electric utility enterprise typically involved in utility operations. In this paper, a proposal that adopting CIM to WAMAC model be submitted so that the integration of various legacy system and application for itself be able to be flexible.

  • PDF

The Structure Of The New EMS in KEPCO (한국전력공사의 차세대 EMS 구상)

  • Yu, Sung-Chul;Kim, Chung-Kil;Kim, Jae-Ki;Lee, In-Kyu;Kim, Sung-Hak
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.893-895
    • /
    • 1996
  • This paper presents the concept of the structure and major functions for the new EMS in KEPCO. This system will be in operation in the beginning of the 21 century in compliance with power system expansion and system architecture consists of distributed and open computer technology. The transmission operation control center as a back-up control center of NCC will control under 345kV transmission system and regional control centers.

  • PDF

EMS 메모리 데이터베이스 동기화 기능 개선 개발

  • Kim, Tae-Seop;Kwak, Jong-Kab;Lee, Seok-Chan
    • Annual Conference of KIPS
    • /
    • 2015.10a
    • /
    • pp.1131-1133
    • /
    • 2015
  • EMS(Energy Management System)는 우리나라 전체 전력 계통을 실시간으로 감시, 제어하고 계통 주파수를 자동으로 조정하여 성능 최적화를 유도하는 시스템으로 전력 계통의 두뇌와 같은 역할을 한다. 본 연구에서는 차세대 EMS(Next Generation Energy Management System: NG-EMS)에서 Enable과 Standby 서버 간 데이터베이스 동기화 기능 개선 개발 기술을 소개한다. EMS는 원방제어감시에 사용되는 SCADA(Supervisory Control And Data Acquisition) 데이터를 포함하여 자동발전, 경제급전 등의 전력 계통을 위해 가공된 데이터를 메모리 데이터베이스에 저장한다. 본 연구에서는 EMS의 메모리 데이터베이스에 저장되어 있는 데이터를 시스템 운영자가 선별을 하여 동기화를 수행할 수 있도록 한다. 또한 동기화 되고 있는 현황을 가시적으로 보임으로써 Enable 서버의 장애 발생 시 Standby 서버로의 대체가 유연하고 안정적이며, 신뢰성을 줄 수 있다.

A Study on the Substation for the Bad Measuring Devices Detection and Correction (변전소 측정기기의 검.교정 알고리즘에 관한 연구)

  • Lee, H.J.;Park, S.M.;Kim, Y.H.;Kim, J.K.
    • Proceedings of the KIEE Conference
    • /
    • 2001.05a
    • /
    • pp.313-315
    • /
    • 2001
  • The power system automation, especially the substation automation is a major issue. so it has been widely studied each country in the world. Since the substation system includes lots of measuring devices. a lot of data and system information are transmitted to operators. The measured values usually have the error that results from the communication process, and it can degrade the reliability of estimated values. So. the detection and correction of measured values at a substation are important factors for substation automation. In this paper, we study the detection and col of measured values at the domestic 154kV/2 distribution substation of double bus structure study will be useful for expected economic dispatch measuring device's inspection and corr management by SCADA system operation, substation automation.

  • PDF

Development of open MMI system for integration of business computers and process computers (포항제철소 B/C-P/C 통합을 위한 개방형 MMI 개발)

  • 추영열;김경백;황화원;김영일
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.684-687
    • /
    • 1997
  • In order to access to the Business Computer (B/C), the Process Computer(P/C), and the Database Server in one terminal, the Open Man Machine Interface (MMI) System has been developed. The testbed to develop the interface functions for B/C, P/C, DB server, and CCD camera were constructed, which consisted of Workstations and Personal Computers (PC). Graphic display programs Monitoring the process states of Tandem Cold Mill plant were developed using four Graphic User Interface tools: InTouch, FIX32, Open Interface Environment, and ILOG Views. With regard to the CPU utilization and response delay required to open new display, the performance tests have been carried out on each MMI platform.

  • PDF

Fuzzy Petri-net Approach to Fault Diagnosis in Power Systems Using the Time Sequence Information of Protection System

  • Roh, Myong-Gyun;Hong, Sang-Eun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1727-1731
    • /
    • 2003
  • In this paper we proposed backward fuzzy Petri-net to diagnoses faults in power systems by using the time sequence information of protection system. As the complexity of power systems increases, especially in the case of multiple faults or incorrect operation of protective devices, fault diagnosis requires new and systematic methods to the reasoning process, which improves both its accuracy and its efficiency. The fuzzy Petri-net models of protection system are composed of the operating process of protective devices and the fault diagnosis process. Fault diagnosis model, which makes use of the nature of fuzzy Petri-net, is developed to overcome the drawbacks of methods that depend on operator knowledge. The proposed method can reduce processing time and increase accuracy when compared with the traditional methods. And also this method covers online processing of real-time data from SCADA (Supervisory Control and Data Acquisition)

  • PDF