• Title/Summary/Keyword: SAR(Specific absorption rate)

Search Result 91, Processing Time 0.025 seconds

Design of a Compact MIMO Antenna for Smart Glasses (스마트 안경용 초소형 MIMO 안테나 설계)

  • Choi, Sehwan;Choi, Jaehoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.4
    • /
    • pp.351-354
    • /
    • 2017
  • In this paper, a compact MIMO(Multiple Input Multiple Output) antenna for smart glasses is proposed. The proposed MIMO antenna is designed using T-shaped isolator inserted between two closely located Inverted-F Antenna(IFA) and using two slots located in the ground for isolation enhancement and impedance matching characteristic. The proposed antenna has only the overall dimensions of $35mm{\times}9mm{\times}0.8mm$ and operates in the 2.4 GHz industrial, scientific, and medical(ISM) band. To verify human body effect, the phantom is used for antenna performance. The measured specific absorption rate(SAR) value is 1.38 W/kg with an input power of 18 dBm. The performance of the proposed antenna is compared with that of previous works for verification.

Development of a Model to Evaluate RF Exposure Level from Cellular Phone using a Neural Network (신경망을 이용한 휴대전화에 의한 RF 노출 평가 모델의 개발)

  • Kim Soo-Chan;Nam Ki-Chang;Ahn Seon-Hui;Kim Deok-Won
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.10 s.89
    • /
    • pp.969-976
    • /
    • 2004
  • The wide and growing use of cellular phones has raised the question about the possible health risks associated with radio-frequency electromagnetic fields. It would be helpful for phone users to blow the exposure levels during cellular phone use. But it is very difficult to recognize the amount of exposure, because measuring accurate level of RF is a difficult matter. In this study, we developed a model to estimate the exposure level and the individual risk of exposure by utilizing the available informations that we can get. We used such parameters as usage time a day, total using period, distance between cellular phone and head, slope of cellular phone, hands-free usage, antenna pulled out or not SAR(Specific Absorption Rate) of cellular phone, and flip or folder type. We proposed a model presenting individual risk of RF exposure from level 0 to 10 by using a neural network.

A Study on the SAR Measurement System Validation at 150 MHz Band (150 MHz 대역에서의 SAR 측정시스템의 유효성 연구)

  • Choi, Donggeun;Kim, Kihwea;Choi, Jaehoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.10
    • /
    • pp.1008-1016
    • /
    • 2013
  • SAR measurement which was applied only to the mobile phone has been expanded in the Korean radio regulation law to the portable wireless communication equipments within 20 cm from the human body since Jan. 2012. The two-way radio operating at 150 MHz frequency band was newly included following the revised radio regulation in the target equipment of measurement. SAR measurement system at 150 MHz satisfying this regulation is necessary accordingly for SAR conformity assessment. The international SAR measurement standard(IEC 62209-2) includes the evaluation method on frequencies above 300 MHz, and the commercial SAR measurement system can measure SAR above 300 MHz only. The size of the reference dipole antenna(760 mm, return loss: -27.57 dB) and flat phantom ($1,300 mm(L){\times}900 mm(W){\times}200 mm(H)$), targeted SAR values for numerical analysis(1 g: 1.08 W/kg, 10 g: 0.77 W/kg) for SAR validation evaluation at 150 MHz frequency are proposed in this paper. The suggested dipole antenna and flat phantom are assembled and used to verify the conformity assessment of commercial SAR measurement system. The measured SAR values of 1 g and 10 g were obtained respectively to be 1.13 W/kg, 0.81 W/kg, and they satisfied the effective range(within ${\pm}10$ %) of IEC international standard. The standards based on this study are expected to be used for the domestic SAR measurement standard and IEC(International Electrotechnical Commission) international standard.

Implementation about measurement of the head SAR and variable parameter according to operation control mode in brain MR study with 1.5Tesia (1.57 BRAIN MRI검사에서의 작동제어모드를 통한 두부 SAR측정과 변화인자에 관한 고찰)

  • Lee, Kyu-Su;Sim, Hyun;Moon, Ji-Hoon;Oh, Jae-Cheol
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.58-60
    • /
    • 2007
  • Magnetic Resonance Imaging(MRI) has become a very widely used medical procedur e. Clo.sed and open systems are typically used with static magnetic fields at or below 2 Tesla. BWhole body SAR(specific absorbsion rate) is the value of SAR averaged over the entire body of the patient over any period of 15 minutes. Head SAR is the value of SAR averaged over the head of the patient for any period of 10 minutes. SAR is a measure of the absorption of electromagnetic energy in the body' (typically in watts per kilogram (W/kg)). The normal operating mode comprises values of head SAR not higher than 3 W/kg. The second level controlled operating mode comprises values higher than 3 W/kg. Current FDA guidance limits the SAR in the whole body. including the head to a range of 1.5 to 4.0 W/kg, depending on the patient's clinical condition. SAR, limit restrictions are incorporated in all MRI systems. and domestic' s guidance limits the SAR in a part body. including the head to 3.2w/kg and less. The purpose of this study is to evaluate on change of head SAR in using MRI pulse sequence and to check if exceed 3.2(w/kg) level in domestic a part exposure through measured head SAR. 23 patient's the average head SAR of pulse sequence is that T2WI sagittal is 0.5375. T2WI axial(FSE) is 0.4817, T1WI axial(SE) is, 0.8179. FLAIR axial is 0.4580. GRE axial is 0.0077, Diffusion is 0.0824w/kg. The head SAR exposed per patient was proved 2.3845w/kg less than the international standard. Coefficient of correlation for the relations body weight and SAR or for the relations ETL(echo train length) and SAR is 1 value. Coefficient of correlation for the relations between TR(time to repeat) and SAR is -0.602 value. so SAR increased relative to weight body and ETL. But the relations between TR and SAR is negative definite.

  • PDF

Human Safety Assessment for a 4 × 8 Array Antenna Used for Wireless Power Transfer at 2.4 GHz (2.4 GHz의 무선전력전송에 사용되는 4 × 8 배열 안테나에 대한 인체안전성평가)

  • Ju, Young Jun;Kim, Jun Hee;Lee, Yu-ri;Gimm, Yoon-Myoung;Lim, Yong Seok
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.10a
    • /
    • pp.338-341
    • /
    • 2018
  • Wireless Power Transfer(WPT) of array antenna applied to beam-forming techniques enables highly efficient WPT when transmitters and receivers are not contacting and even when they are separated. However, this WPT method is possible to use only when human safety restriction by distance between the transmitters and the receivers is satisfied. In the paper, a $4{\times}8$ array antenna for 2.4 GHz is modeled by simulation, then electric field intensity and 10 gram average head SAR(Specific Absorption Rate) by distance away from the array antenna inputted 1 W of 2.4 GHz sinusoidal wave at each single antenna of the array antenna for 2.4 GHz were obtained. And they were compared with human safety restriction of draft of 2018 ICNIRP(International Commission on Non-Ionizing Radiation Protection) guidelines. As the result, power density of far field derived from the electric field intensity was $33.257W/m^2$, which satisfied with occupational human safety restriction but exceeded public's. In addition, the 10 gram average head SAR exceeded the human safety restriction.

  • PDF

Analysis of Electromagnetic Wave Exposure Due to 6.78 MHz Wireless Power Transfer System (6.78 MHz 무선전력전송 시스템에 의한 전자파 노출량 분석)

  • Yoon, Seok;Jung, Hyeonjong;Lim, Yeongseog
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.12
    • /
    • pp.954-963
    • /
    • 2017
  • In this paper, we analyzed the electric/magnetic field distribution and SAR distribution in a human body due to the resonant-type wireless power transfer(WPT) system with an operating frequency of 6.78 MHz. To analyze the field distribution under the unperturbed condition, a prototype system was fabricated and the measured results were compared with the simulation results. For safety during measurement, the available power to the transmitter coil is limited to 1 W. To analyze the induced current density and SAR distribution, a simple human model consisting of three layers, skin, fat, and muscle, was used for the simulation. The electromagnetic wave exposure levels obtained through measurement and simulation were compared with the recommended levels by the ICNIRP.

A Triple Band Deep-Tissue Antenna for Biomedical Implants (심부 조직 인체 삽입용 세 가지 밴드 안테나)

  • Yoo, Hyoungsuk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.2
    • /
    • pp.383-386
    • /
    • 2017
  • In this study, we introduce a triple-band flexible implantable antenna that is tuned by using a ground slot in three specific bands, namely Medical Implanted Communication Service (MICS: 402-405 MHz) for telemetry, the midfield band (lower gigahertz: 1.45-1.6 GHz) for Wireless Power Transfer (WPT), and the Industrial, Scientific and Medical band (ISM: 2.4-2.45 GHz) for power conservation. This antenna is wrapped inside a printed 3D capsule prototype to show its applicability in different implantable or ingestible devices. The telemetry performance of the proposed antenna was simulated and measured by using a porcine heart. From the simulation and measurement, we found that use of a ground slot in the implantable antenna can improve the antenna performance and can also reduce the Specific Absorption Rate (SAR).

High-resolution Spiral-scan Imaging at 3 Tesla MRI (3.0 Tesla 자기공명영상시스템에서 고 해상도 나선주사영상)

  • Kim, P.K.;Lim, J.W.;Kang, S.W.;Cho, S.H.;Jeon, S.Y.;Lim, H.J.;Park, H.C.;Oh, S.J.;Lee, H.K.;Ahn, C.B.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.10 no.2
    • /
    • pp.108-116
    • /
    • 2006
  • Purpose : High-resolution spiral-scan imaging is performed at 3 Tesla MRI system. Since the gradient waveforms for the spiral-scan imaging have lower slopes than those for the Echo Planar Imaging (EPI), they can be implemented with the gradient systems having lower slew rates. The spiral-scan imaging also involves less eddy currents due to the smooth gradient waveforms. The spiral-scan imaging method does not suffer from high specific absorption rate (SAR), which is one of the main obstacles in high field imaging for rf echo-based fast imaging methods such as fast spin echo techniques. Thus, the spiral-scan imaging has a great potential for the high-speed imaging in high magnetic fields. In this paper, we presented various high-resolution images obtained by the spiral-scan methods at 3T MRI system for various applications. Materials and Methods : High-resolution spiral-scan imaging technique is implemented at 3T whole body MRI system. An efficient and fast higher-order shimming technique is developed to reduce the inhomogeneity, and the single-shot and interleaved spiral-scan imaging methods are developed. Spin-echo and gradient-echo based spiral-scan imaging methods are implemented, and image contrast and signal-tonoise ratio are controlled by the echo time, repetition time, and the rf flip angles. Results : Spiral-scan images having various resolutions are obtained at 3T MRI system. Since the absolute magnitude of the inhomogeneity is increasing in higher magnetic fields, higher order shimming to reduce the inhomogeneity becomes more important. A fast shimming technique in which axial, sagittal, and coronal sectional inhomogeneity maps are obtained in one scan is developed, and the shimming method based on the analysis of spherical harmonics of the inhomogeneity map is applied. For phantom and invivo head imaging, image matrix size of about $100{\times}100$ is obtained by a single-shot spiral-scan imaging, and a matrix size of $256{\times}256$ is obtained by the interleaved spiral-scan imaging with the number of interleaves of from 6 to 12. Conclusion : High field imaging becomes increasingly important due to the improved signal-to-noise ratio, larger spectral separation, and the higher BOLD-based contrast. The increasing SAR is, however, a limiting factor in high field imaging. Since the spiral-scan imaging has a very low SAR, and lower hardware requirements for the implementation of the technique compared to EPI, it is suitable for a rapid imaging in high fields. In this paper, the spiral-scan imaging with various resolutions from $100{\times}100$ to $256{\times}256$ by controlling the number of interleaves are developed for the high-speed imaging in high magnetic fields.

  • PDF

Development and evaluation of MR compatible patch antenna for hyperthermia (온열치료를 위한 MR호환 평판가열안테나 개발 및 성능평가)

  • Kim, D.H.;Chun, S.I.;Jang, M.Y.;Yoon, M.S.;Kim, Y.B.;Jung, B.D.;Nam, S.H.;Mun, C.W.
    • Journal of the Korean Society of Radiology
    • /
    • v.3 no.2
    • /
    • pp.17-21
    • /
    • 2009
  • The thermal treatment have been combined with MRI which is able to acquire both an anatomical image with high-contrast and a thermal image, and have recently used for removing the tumor effectively. This study is to make a patch antenna which is designed to operate at 2.45GHz that has compatibility with MRI. The characteristic and specific absorption rate(SAR) were confirmed using computer simulation and confirmed a possibility of hyperthermia by performing experiment.

  • PDF

Design and SAR Analysis of Broadband Monopole Antenna Using Loop and T-Shaped Patches (사각 루프와 T자형 패치를 결합한 광대역 평면형 모노폴 안테나 설계 및 SAR 분석)

  • Jang, Ju-Dong;Lee, Seungwoo;Kim, Nam;Choi, Dong-Geun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.1
    • /
    • pp.1-10
    • /
    • 2013
  • In this paper, a broadband planar monopole antenna for multi-band services is proposed. The physical size of the proposed antenna is miniaturized by folding a rectangular loop. And a resonance point in the 3.9 GHz band is reduced by a coupling phenomenon with the central part of the T-shaped patch and the folded rectangular loop. In addition, the T-shaped patch is inserted to the rectangular shaped monopole antenna due to deriving the broadband frequency characteristics. The frequency characteristic is optimized by adjusting the gap and length of the folded rectangular loops and a transverse diameter of the T-shaped patch. The antenna dimensions including the ground plane are $40{\times}60{\times}1.6mm^3$. It is fabricated on the FR-4 substrate(${\epsilon}_r$=4.4) using a microstrip line of $50{\Omega}$ for impedance matching. In the measured result, the bandwidth corresponding to the VSWR of 2:1 is 162 MHz(815~977 MHz) and 2,530 MHz(1.43~3.96 GHz). For analyzing the human effect by the proposed antenna, 1 g and 10 g averaged SARs are simulated and measured. As the simulated results, 1 g-averaged SAR is 1.044 W/kg, and 10 g-averaged SAR is 0.718 W/kg. This result are satisfied by the SAR guidelines which are 1.6 W/kg(1 g-averaged) and 2.0 W/kg(10 g-averaged).