• Title/Summary/Keyword: SAG2

Search Result 218, Processing Time 0.033 seconds

Analysis of Couch Sag Using Image Processing of MVCT Images in Tomotherapy (토모테라피에서 MVCT 영상을 이용한 환자 테이블의 처짐 정도의 분석)

  • Park, Ha Ryung;Kim, Yong Ho;Park, Dahl;Kim, Wontaek;Ki, Yongkan;Kim, Donghyun;Bae, Jin Suk
    • Progress in Medical Physics
    • /
    • v.26 no.2
    • /
    • pp.106-111
    • /
    • 2015
  • In Tomotherapy the couch sags during the treatment due to the weight of the patient. In this study, we developed a simple method to obtain the amount of the sag and the pitch angle of the couch using the image processing technique of MVCT images in Tomotherapy. Using the method we evaluated the sag and pitch of couch for 22 head and neck patients and one craniospinal irradiation (CSI) patient. The sag and the average pitch angle of couch were 0.40~1.54 mm and $0.7^{\circ}$ for head and neck patients, respectively. For head and neck patients, the sag increased as the longitudinal length of the irradiation volume increased and the pitch angle showed no relationship with the longitudinal length. For the CSI patient the sag was 4.97 mm. Using the method the amount of the couch sag could be measured easily and the measured data could be useful in determination of margins considering the table sag error.

Characteristics of Voltage Sag/Swell Compensator Utilizing Single-Phase Matrix Converter

  • Yamamoto, Kichiro;Ikeda, Keisuke;Tsurusaki, Yu;Ikeda, Minoru
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.2 no.4
    • /
    • pp.447-453
    • /
    • 2013
  • Compensating characteristics of a voltage sag/swell compensator utilizing single-phase matrix converter is examined. First, system configuration and operation for both voltage sag and swell are described. Next, in order to suppress pulsations of the source voltage, a countermeasure using low pass filter and all pass filter is introduced. Then, compensating characteristics of the compensator are investigated for R-L load by simulation. Finally, the validity of the simulated results is confirmed by the experimental results.

Compensating Characteristics of Voltage Sag Compensator Utilizing Single-Phase Matrix Converter

  • Yamamoto, Kichiro;Ikeda, Keisuke;Iimori, Kenichi
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.2 no.1
    • /
    • pp.77-82
    • /
    • 2013
  • By using simulation, compensating characteristics of a voltage sag compensator utilizing single-phase matrix converter is examined. System configuration is described and mathematical model of single-phase matrix converter is derived by using the state space averaging method. In addition, the single-phase matrix converter is stabilized by phase-lead compensation. Finally, compensating characteristics of the compensator is investigated for 500 W R-L load and it is demonstrated that the compensator can operate correctly for loads for the range of power factor 0.6 (lagging) - 0.8 (leading) and for up to 50% voltage sag.

Analysis on Voltage Compensating Effect of DVR using PSCAD/EMTDC (PSCAD/EMTDC를 이용한 DVR의 전압보상 효과분석)

  • Park, Sang-Ho;Choy, Young-Do;Park, Young-Shin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.9
    • /
    • pp.165-171
    • /
    • 2010
  • There are many researches on Power Quality Device to protect the critical load and power system as the nonlinear load and precision load are adopted into the power system recently. To analyze the voltage compensation of voltage sag and voltage swell by DVR, which is connected to the important load in series, this paper shows PSCAD/EMTDC simulation and its verification by comparing with the actual DVR output of 2MVA. DVR control scheme in this paper is applicable to compensate single-phase, 2-phases or 3-phases voltage sag as well as DVR for distribution system.

An Investigation into the Impact on Voltage Sag due to Faults in Low Voltage Power Distribution Systems

  • Aggarwal R. K.
    • KIEE International Transactions on Power Engineering
    • /
    • v.5A no.2
    • /
    • pp.97-102
    • /
    • 2005
  • Voltage sags are the most widespread quality issues affecting distribution systems. This paper describes in some detail the voltage sag characteristics due to different types and locations of fault in a practical low voltage power distribution system encountered in the UK. The results not only give utility engineers very useful information when identifying parts of the system most likely to pose problems for customer equipments, but also assist the facility personnel to make decisions on purchasing power quality mitigation equipment.

Should We Recommend Ultrasonography for an Incidental Thyroid Nodule on Additional Cervicothoracic Sagittal T2-Weighted Image of Lumbar Spine MRI?

  • Cho, Hee Woo;Park, Jin-Oh;Lee, Young Han;Chung, Soo Yoon;Suh, Jin-Suck
    • Investigative Magnetic Resonance Imaging
    • /
    • v.19 no.4
    • /
    • pp.224-230
    • /
    • 2015
  • Purpose: To determine whether we should recommend ultrasonography (US) for an incidental thyroid nodule identified by additional cervicothoracic sagittal T2-weighted image (C-T sag T2WI) of lumbar spine magnetic resonance imaging (MRI). Materials and Methods: A retrospective study of 61 patients who underwent both lumbar spine MRI and thyroid US between December 2011 and April 2015 was conducted. For all US-found thyroid nodules > 1 cm, investigators evaluated whether there was any correlation between thyroid nodule detectability by C-T sag T2WI and US features such as echogenicity, composition, or suspicion of malignancy. Results: Solid hypoechoic (2/4; 50%) or mixed echoic nodules (4/8; 50%) appeared to be found relatively more easily by C-T sag T2WI than more benign-looking solid isoechoic (1/4; 25%) or spongiform nodules (0/6; 0%). Among six nodules with ultrasonographic suspicion for malignancy, only one nodule was detected by C-T sag T2WI. Conclusion: If an incidental thyroid nodule is seen by C-T sag T2WI, it would be better to recommend thyroid US for identifying malignancy.

Tat-Fused Recombinant Human SAG Prevents Dopaminergic Neurodegeneration in a MPTP-Induced Parkinson's Disease Model

  • Sohn, Eun Jeong;Shin, Min Jea;Kim, Dae Won;Ahn, Eun Hee;Jo, Hyo Sang;Kim, Duk-Soo;Cho, Sung-Woo;Han, Kyu Hyung;Park, Jinseu;Eum, Won Sik;Hwang, Hyun Sook;Choi, Soo Young
    • Molecules and Cells
    • /
    • v.37 no.3
    • /
    • pp.226-233
    • /
    • 2014
  • Excessive reactive oxygen species (ROS) generated from abnormal cellular process lead to various human diseases such as inflammation, ischemia, and Parkinson's disease (PD). Sensitive to apoptosis gene (SAG), a RING-FINGER protein, has anti-apoptotic activity and anti-oxidant activity. In this study, we investigate whether Tat-SAG, fused with a Tat domain, could protect SH-SY5Y neuroblastoma cells against 1-methyl-4-phenylpyridinium ($MPP^+$) and dopaminergic (DA) neurons in the substantia nigra (SN) against 1-methyl-4-phenyl-1,2,3,6-tetra-hydropyridine (MPTP) toxicity. Western blot and immunohistochemical analysis showed that, unlike SAG, Tat-SAG transduced efficiently into SH-SY5Y cells and into the brain, respectively. Tat-SAG remarkably suppressed ROS generation, DNA damage, and the progression of apoptosis, caused by $MPP^+$ in SH-SY5Y cells. Also, immunohistochemical data using a tyrosine hydroxylase antibody and cresyl violet staining demonstrated that Tat-SAG obviously protected DA neurons in the SN against MPTP toxicity in a PD mouse model. Tat-SAG-treated mice showed significant enhanced motor activities, compared to SAG- or Tat-treated mice. Therefore, our results suggest that Tat-SAG has potential as a therapeutic agent against ROS-related diseases such as PD.

Bus-voltage Sag Suppressing and Fault Current Limiting Characteristics of the SFCL Due to its Application Location in a Power Distribution System

  • Kim, Jin-Seok;Lim, Sung-Hun;Kim, Jae-Chul
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.6
    • /
    • pp.1305-1309
    • /
    • 2013
  • The application of the superconducting fault current limiter (SFCL) in a power distribution system is expected to contribute the voltage-sag suppression of the bus line as well as the fault-current reduction of the fault line. However, the application effects of the SFCL on the voltage sag of the bus line including the fault current are dependent on its application location in a power distribution system. In this paper, we investigated the fault current limiting and the voltage sag suppressing characteristics of the SFCL due to its application location such as the outgoing point of the feeder, the bus line, the neutral line and the 2nd side of the main transformer in a power distribution system, and analyzed the trace variations of the bus-voltage and fault-feeder current. The simulated power distribution system, which was composed of the universal power source, two transformers with the parallel connection and the impedance load banks connected with the 2nd side of the transformer through the power transmission lines, was constructed and the short-circuit tests for the constructed system were carried out. Through the analysis on the short-circuit tests for the simulated power distribution system with the SFCLs applied into its representative locations, the effects from the SFCL's application on the power distribution system were discussed from the viewpoints of both the suppression of the bus-voltage sag and the reduction of the fault current.

Evaluation of Optimal Condition for Recombinant Bacterial Ghost Vaccine Production with Four Different Antigens of Streptococcus iniae-enolase, GAPDH, sagA, piaA (연쇄구균증 항원-enolase, GAPDH, sagA, piaA에 대한 재조합 고스트 박테리아 백신의 생산 최적화)

  • Ra, Chae-Hun;Kim, Yeong-Jin;Son, Chang-Woo;Jung, Dae-Young;Kim, Sung-Koo
    • Journal of Life Science
    • /
    • v.19 no.7
    • /
    • pp.845-851
    • /
    • 2009
  • A vector harboring double cassettes; a heterologous gene expression cassette of pHCE-InaN-antigen and a ghost formation cassette of pAPR-cI-E lysis 37 SDM was constructed and introduced to E. coli DH5a. For the production of a bacterial ghost vaccine, bacterial ghosts from E. coli / Streptococcus iniae with four different types of antigens - enolase, GAPDH, sagA and piaA - were produced by the optimization of fermentation parameters such as a glucose concentration of 1 g/l, agitation of 300 rpm and aeration of 1 vvm. Efficiency of ghost bacteria formation was evaluated with cultures of OD$_{600}$=1.0, 2.0 and 3.0. The efficiency of the ghost bacteria formation was 99.54, 99.67, 99.99 and 99.99% with inductions at OD$_{600}$=3.0, 1.0, 2.0 and 1.0 for E. coli/S. iniae antigens enolase, piaA, GAPDH and sagA, respectively. Ghost bacteria as a vaccine was harvested by centrifugation. The antigen protein expressions were analyzed by SDS-PAGE and western blot analysis, and the molecular weights of the enolase, piaA, GAPDH and sagA were 78, 26, 67 and 26 kDa, respectively. The molecular weights of the expressed antigens were consistent with theoretical sizes obtained from the amino acid sequences.

A Study on the Coordination Scheme Considering the Loss of Sensitive Load by Voltage Sag at Distribution System Interconnected Dispersed Generation (배전계통에 분산전원 연계시 전압강하에 의한 민감부하의 피해를 고려한 보호협조 연구)

  • Jung, Seung-Bock;Kim, Jae-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.363-365
    • /
    • 2003
  • Recently, the concern of power qualiaty problem is increasing. Especially, Voltage quality problem have been increased important problem. Electronic device was affected by voltage sag. So, sensitive load that included many electronic Device was affected by voltage sag. also, it may have economic loss. In this paper, we argue the coordination scheme considering the loss of sensitive load. The coordination device of distribution system for instaneous fault is recloser and sectionalizer, But, the fault clearing time of recloser is more than 2 seconds. So, voltage sag generates long time that affected sensitive load. HS(high speed switchgear) has fast fault clearing time(0.015s) that not affected sensitive load. Therefore, the coordination applied HS is used. The proposed schemes are proved and evaluated by a case study using PSCAD/EMTDC simulation.

  • PDF