Analysis of Couch Sag Using Image Processing of MVCT Images in Tomotherapy  

Park, Ha Ryung (Department of Radiation Oncology, Pusan National University Hospital)
Kim, Yong Ho (Department of Radiation Oncology, Pusan National University Hospital)
Park, Dahl (Department of Radiation Oncology, Pusan National University Hospital)
Kim, Wontaek (Department of Radiation Oncology, Pusan National University School of Medicine)
Ki, Yongkan (Department of Radiation Oncology, Pusan National University School of Medicine)
Kim, Donghyun (Department of Radiation Oncology, Pusan National University School of Medicine)
Bae, Jin Suk (Department of Radiation Oncology, Pusan National University Hospital)
Publication Information
Progress in Medical Physics / v.26, no.2, 2015 , pp. 106-111 More about this Journal
Abstract
In Tomotherapy the couch sags during the treatment due to the weight of the patient. In this study, we developed a simple method to obtain the amount of the sag and the pitch angle of the couch using the image processing technique of MVCT images in Tomotherapy. Using the method we evaluated the sag and pitch of couch for 22 head and neck patients and one craniospinal irradiation (CSI) patient. The sag and the average pitch angle of couch were 0.40~1.54 mm and $0.7^{\circ}$ for head and neck patients, respectively. For head and neck patients, the sag increased as the longitudinal length of the irradiation volume increased and the pitch angle showed no relationship with the longitudinal length. For the CSI patient the sag was 4.97 mm. Using the method the amount of the couch sag could be measured easily and the measured data could be useful in determination of margins considering the table sag error.
Keywords
Tomotherapy; MVCT; Couch sag;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Ramsey C, Dube S, Hendee WR, et al: Is is necessary to validate each individual IMRT treatment plan before delivery Med Phys 30:2271-2273 (2003)   DOI
2 Olivera GH, Shepard DM, Ruchala KJ, et al: "Tomotherapy." In The Modern Technology of Radiation Oncology: A Compendium for Medical Physicists and Radiation Oncologists. (Madison, WI) 521-587 (1999)
3 Ruchala KJ, Olivera GH, Kapatoes J, et al: Limited-data image registration for radiotherapy positioning and verification. Int J Radiat Oncol Biol Phys 54:592-605 (2002)   DOI
4 mackie TR, Olivera GH, Kapatoes JM, et al: Intensity-modulated radiation therapy. The state of the art. AAPM Summer School Proceedings. Colorado Springs, CO: Med Phys. Publishing 247-284 (2003)
5 Boswell SA, Jeraj R, Ruchala KJ, et al: A novel method to correct for pitch and yaw patient setup errors in helical tomotherapy. Med Phys 32:1630-1639 (2005)   DOI
6 Logan DL: First course in the element method. (Boston:PWS Publishing Company, Inc)
7 Kazubek M: Wavelet domain image denoising by thresholding and Wiener filtering. Signal Processing Letters IEEE 10:324-326 (2003)   DOI
8 Kaiser A, Schultheiss TE, Wong JYC, et al: Pitch, roll, and yaw variations in patient positioning. Int J Radiation Oncology Biol Phys 66:949-995 (2006)   DOI
9 Hornick DC, Litzenberg DW, Lam KL, et al: A tilt and roll device for automated correction of rotational setup errors. Med Phys 25:1739-1740 (1998)   DOI
10 Litzenberg DW, Balter JM, Hornic DC, et al: A mathematical model for correcting patient setup errors using a tilt and roll device Med Phys 26:2586-2588 (1999)   DOI