• Title/Summary/Keyword: SAFE 댐퍼

Search Result 13, Processing Time 0.018 seconds

Force Control of Main Landing Gear using Hybrid Magneto-Rheological Damper (하이브리드 MR댐퍼를 이용한 주륜 착륙장치 하중제어기법 연구)

  • Hyun, Young-O;Hwang, Jae-Up;Hwang, Jae-Hyuk;Bae, Jae-Sung;Lim, Kyoung-Ho;Kim, Doo-Man;Kim, Tae-Wook;Park, Myung-Ho
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.4
    • /
    • pp.315-320
    • /
    • 2010
  • To improve not only the basic performance but also the fail-safe performance, power consumption of the main landing gear for helicopters, a semi-active control landing gear using hybrid MR damper, was introduced in this paper. This damper of the configuration to install a permanent magnet in a electromagnet MR damper, was designed by the trade-off study on permanent magnet location and a magnet field analysis. Force control algorithm which keep the sum of air spring force and damping force at a specified value during landing, was used for the controller. The drop simulations using ADAMS Model for this semi-active control landing gear, were done. The improvement of the preceding performances as the result to evaluate the landing performance by the simulations, has been confirmed.

Structural Performance of RC Frame with SAFE Damper (SAFE댐퍼 보강골조의 구조성능 실험적 평가)

  • So, Byeong-Chan;Lee, Chang-Hwan;Ju, Young-Kyu
    • Journal of Korean Association for Spatial Structures
    • /
    • v.15 no.1
    • /
    • pp.85-94
    • /
    • 2015
  • SAFE damper is a hybrid damper which is comprised of a friction damper and a metallic damper. These two dampers combine to resist external energy in stages. Under minor earthquake loads, the friction damper operates alone. However, the friction damper and metallic damper dissipate the energy together when a severe earthquake occurs. In comparison with other methods for seismic retrofitting, the SAFE damper has many advantages. The SAFE damper doesn't cause damage to façade of the building, and the construction period can be reduced when retrofitting. This paper describes experiments evaluating the structural performance of the SAFE damper. From the results, it was found that the structural performance of a conventional RC bare frame can be significantly improved by the installation of the SAFE damper.

Pressure Differentials in the Elevator Lobby Depending on the Reference Pressures of the Pressurizing Dampers (급기가압 댐퍼의 설정 기준압에 따른 부속실 차압 특성 연구)

  • Park, Yong-Hwan
    • Fire Science and Engineering
    • /
    • v.21 no.4
    • /
    • pp.12-17
    • /
    • 2007
  • This paper investigated pressure differentials in the elevator lobby depending on reference pressures of the pressurizing damper using FDS fire modeling. The results showed the temperatures and pressures in the contained fire room with small leak gaps can increase significantly. Setting reference pressure of the pressurizing dampers to 0 Pa can cause reduction of real pressure differentials and air velocity to resist smoke flow. This would cause smoke movement from fire room to elevator lobby which should be safe area for evacuation.

Basic Study on the Performance of a Pressure-difference Control Damper Affected by Flow Disturbance in a Wind Tunnel (풍도 내 유동 교란과 자동차압 댐퍼의 성능 특성 기초 연구)

  • Yun, Yung-Min;Lee, Min-Jung;Kim, Nam-Il;Ryou, Hong-Sun
    • Fire Science and Engineering
    • /
    • v.23 no.6
    • /
    • pp.16-23
    • /
    • 2009
  • The performance characteristics of a smoke damper, which aims to suppress the penetration of smoke to a safe area, have been tested under the regulation of the FIS 001. However, the improvement of the test methods and the regulation has consecutively been requested. From a view-point of fluid mechanical theory, a pressure control damper, that is installed at the end of the flow control system, is important and it dominates flow characteristics in all designed flow systems. In this study, the weak points of the regulation of the FIS 001 concerned with the pressure control damper was visited and the some important characteristics of the damper was examined. Based on these results, it was confirmed that the effects of flow disturbance in the air supplying duct on the performance of the damper are not significant. This results gives some information for the modification of the experimental regulation concerned to the pressure control damper.

The Experimental Study on the Leakage of Automatic Pressure Differential · Overpressure Control Dampers (자동차압 · 과압조절형댐퍼의 누설량 실험 연구)

  • Shin, Pyung-Shik;Kim, Hak-Joong
    • Fire Science and Engineering
    • /
    • v.29 no.6
    • /
    • pp.71-75
    • /
    • 2015
  • Recently, Since buildings are bigger and higher, the damage of human life can be increased by fire flame and smoke in fire. Smoke control system is necessary to decrease this damage. Therefore, Air supply pressurization smoke control system is applied to vestibule of escape stairway. NFSC requires pressure differential of 40 Pa~60 Pa, but pressure differential is over 60 Pa in the field. It is known that the cause of this over pressure differential is much leakage of damper. Over pressure differential can bad effect to escaper by pressurizing the door. Analyze the real leakage of damper by testing for identifying this problems. The result of testing, leakage is $0.090m^3/s{\sim}0.154m^3/s$. It is necessary to limit the leakage of dampers for safe of escapers.

A Ship Berthing System Design by Cooperating with Tugboats and Dampers (터그보트와 댐퍼 협조제어를 통한 선박접안시스템 설계에 관한 연구)

  • Tran, Anh-Minh D.;Ji, S.W.;Kim, Y.B.
    • Journal of Drive and Control
    • /
    • v.11 no.3
    • /
    • pp.7-13
    • /
    • 2014
  • Everyday about 90% of cargos are delivered by ships, and thousands of vessels enter and depart the international container harbors such as Shanghai, Singapore, Hong Kong, Busan, Rotterdam, etc. Maneuvering at harbor is known as the most sophisticated and difficult procedure, because the effectiveness of actuators during low speed berthing is reduced. In this paper, a new berthing method is discussed. Tugboats are combined with damper systems to ensure safe berthing. A mathematical model describing the interaction between unactuated ship, tugboats and damper systems is presented. An optimal controller is designed to maneuver the ship without oscillation and overshoot. MCL (Marine Cybernetics Lab) model ship is used to evaluate the efficiency of the proposed approach through MatLab simulation.

A Study on the Structural Safety Evaluation of Light Weight Damper for Offshore Rigs (해양시추선용 경량수밀댐퍼의 구조안전성 평가에 관한 연구)

  • Jang, Ji-Seong;Ji, Sang-Won;Han, Seung-Hun
    • Journal of Power System Engineering
    • /
    • v.20 no.6
    • /
    • pp.80-86
    • /
    • 2016
  • In this study, The watertight damper was designed to improve conventional DN 350A butterfly valve. The FSI(Fluid-Structure Interaction) analysis has performed to investigate the safety factor for the watertight damper. When watertight damper of disk was closed, the disk of pressure value is constant. However depending on the opening angle of disk, the flow velocity and pressure are changed. The maximum velocity was appeared at the end of disk on the small outlet area of duct. When the opening angel of disk is $90^{\circ}$, the maximum velocity was appeared at the center of ending disk. So we were found the opening angle of disk is bigger, the flow rate is increased and velocity is also increased from the result of FSI analysis. We can find the least deformation and stress when the opening angel of damper is $90^{\circ}$. When the $45^{\circ}$ opening angle of disk, the largest deformation and stress was found and the minimum safety factor 1.3 was calculated. As a result, we found that the structure of watertight damper is safe enough irrespective of opening angel.

The Study of Reinforcement through the Nonlinear Static Analysis and Inelastic Seismic Performance Evaluation in School Building (학교건물에 있어서 비탄성해석 및 비선형 정적해석을 통한 내진성능 평가에 따른 보강 연구)

  • Lee, Ho;Kwon, Young-Wook;Kim, Hong-Do
    • Journal of Korean Association for Spatial Structures
    • /
    • v.12 no.2
    • /
    • pp.55-63
    • /
    • 2012
  • This study is about earthquake-proof reinforcement through structural function evaluation of an school building. The purpose of this study is to comparatively analyze structure reinforcement measures in consideration of safety and usability through structural function evaluation of school buididng, to offer rational measures for earthquake-proof function and to provide help in maintaining safe structures against earthquake. For this purpose, was selected for this study as an existing school building, earthquake-proof function evaluation was conducted, and measures to reinforce earthquake-proof function was offered. As for the research method, the first and the second earthquake-proof function evaluations were conducted which is an existing reinforced concrete school building. Through the abovementioned methods, earthquake-proof function evaluation were conducted, the results were analyzed and the measure to reinforce earthquake-proof function were offered(Steel damper, Carbon plate stiffeners). The offered measure to reinforce earthquake-proof function was applied to the subject structure, and comprehensive results were derived from earthquake-proof function evaluation regarding before and after earthquake-proof function reinforcement.

Design of a Light Weight Watertight Damper for Offshore Rigs (해양시추선용 경량수밀댐퍼 설계)

  • HAN, Seung-Hun;JANG, Ji-Seong;JI, Sang-Won
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.28 no.5
    • /
    • pp.1470-1477
    • /
    • 2016
  • This study has designed and evaluated the safety of watertight damper for Offshore Rigs. The watertight damper is an improved design for conventional DN 350 butterfly valve. Numerical analysis has been performed to investigate the safety factor and seat leakage of the designed 3-type disk dampers. The structure analysis results present the deformations, the equivalent stresses and the safety factor. It was confirmed that the designed disk, rib-disk and streamlined disk of watertight damper are safe enough in maximum operating pressure of 0.98MPa. The results show that the disk damper had the smallest maximum deformations and stress among 3-type disk dampers and the safety factor was 4.3. Therefore it is confirmed that the disk damper has the most excellent strength. Also linear static structural analysis was individually conducted for disk and body. The results show that the maximum disk deformation was larger than the body deformation, Therefore the disk damper is causes no seat leakage.

The Analysis of Correlation Major System Factors with the Performance of Smoke Control Systems Using Pressure Differentials (차압제연설비의 성능과 관련된 시스템 및 환경 변수와의 상관성 분석)

  • Yeo, Yong-Ju;Kim, Hak-Jung;Park, Yong-Hwan
    • Fire Science and Engineering
    • /
    • v.24 no.2
    • /
    • pp.97-105
    • /
    • 2010
  • The smoke control systems using pressure differentials are already well known as the most reliable method to prevent the smoke infiltration into the emergency stairs or safe spaces. However, it is true that many problems are domestically pointed out due to the insufficient understanding and technology on the smoke control systems using pressure differentials. In this regard, this work analyzed the effect of major factors for smoke control system using pressure differentials such as a duct area, opening area of air supply damper, improvement on open vestibules, stack effect and location of air supply. In conclusion, adequate pressure differentials can not be maintained in small duct because the smaller duct area have the large friction loss. Especially, It is confirmed that the major factor for deterioration of smoke control system performance is stack effect that makes pressure differentials smaller in the lower floors.