• Title/Summary/Keyword: S2S Radiation

Search Result 2,860, Processing Time 0.035 seconds

Reconsideration of CN Radiation an d $C_2$ Dissociation Rate Coefficient ($C_2$의 해리 반응 계수와 CN 복사에 대한 재고찰)

  • Hyun, Seong-Yoon;Park, Chul;Chang, Keun-Shik
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.92-95
    • /
    • 2008
  • We performed the theoretical calculation of CN Violet radiation using the code SPRADIAN07 to predict the Lee et al.'s experimental measurements and to reinvestigate $C_2$ dissociation rate. CN Violet radiations are calculated under the Boltzmann and non-Boltzmann distribution using two chemical reaction sets: Park-Losev-G\"{o}kcen-Tsang and Park-Losev-G\"{o}kcen-Tsang-Lee models. Our SPRADIAN07 calculations show improvement in prediction of absolute radiation intensity of CN Violet and its decay rate by Park-Losev-G\"{o}kcen-Tsang reaction set with $C_2$ dissociation rate coefficient of $k_f$ = 1.5${\times}$10$^{16}$ exp(-71,600/$T_x$) cm$^3$ mole$^{-1}$ s$^{-1}$.

  • PDF

Calculation of Dobe Distributions in Brachytherapy by Personal Microcomputer (Microcomputer를 이용한 근접조사 장치의 선량분포 계산)

  • Chu S. S.;Park C. Y.
    • Radiation Oncology Journal
    • /
    • v.2 no.1
    • /
    • pp.129-137
    • /
    • 1984
  • In brachytherapy, it is important to determine the positions of the radiation sources which are inserted into a patient and to estimate the dose resulting from the treatment. Calculation of the dose distribution throughout an implant is so laborious that it is rarely done by manual methods except for model cases. It is possible to calculate isodose distributions and tumor doses for individual patients by the use of a microcomputer. In this program, the dose rate and dose distributions are calculated by numerical integration of point source and the localization of radiation sources are obtained from two radiographs at right angles taken by a simulator developed for the treatment planning. By using microcomputer for brachytherapy, we obtained the result as following 1. Dose calculation and irradiation time for tumor could be calculated under one or five seconds after input data. 2. It was same value under$\pm2\%$ error between dose calculation by computer program and measurement dose. 3. It took about five minutes to reconstruct completely dose distribution for intracavitary irradiation. 4. Calculating by computer made remarkly reduction of dose errors compared with Quimby's calculation in interstitial radiation implantation. 5. It could calculate the biological isoffect dose for high and low dose rate activities.

  • PDF

High Power RF Commissioning for S-band Electron LINAC

  • Park, Hyung Dal;Lee, Byeong-No;Song, Ki Baek;Cha, Sung Su;Kim, Yujong;Lee, Byung Cheol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.111.2-111.2
    • /
    • 2013
  • 고주파 전자가속기는 고출력 RF 시스템으로 구동된다. 이러한 고주파 전자가속기에서 고출력 RF 시스템은 종종 고출력 방전으로 인해 가속관에 손상을 입힐 수 있기 때문에 조심스럽게 RF conditioning을 진행 하여야 한다. 일반적으로 RF conditioning은 아주 긴 시간을 필요로 하고, RF 출력을 서서히 높여가며 진행할 필요성이 있다. 한국원자력연구원에서는 9 MeV와 6 MeV 에너지를 출력하기 위해서는 가속관으로 RF 입력을 약 5.5 MW까지 RF conditioning을 진행하여야 한다. 따라서, 본 연구에서는 Klystron 최대 출력이 약 5.5 MW로 한국원자력연구원에서 개발된 S-band (2,856 MHz) RF 전자가속관에 RF conditioning을 진행 하였다. 가속관의 진공을 약 1.0e-7을 유지하면서 반복률을 10 Hz부터 180 Hz로 증가시켰고, RF 입력 파워는 약 6 MW까지 RF conditioning을 진행 하였다. 그 결과 짧은 시간에 RF commissioning을 진행할 수 있었다.

  • PDF

Analysis of Public Perception on Radiation: with One Year after Fukushima Nuclear Accident (방사선의 대국민 인식도 분석: 일본 후쿠시마 원전 사고 1주년 계기)

  • Park, Bang-Ju
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.1
    • /
    • pp.1-9
    • /
    • 2012
  • A year has passed since the nuclear power plant accident in Fukushima on March 11, 2011, and a survey for public perception on radiation by Korean people has been made. The methodological design was based on a quantitative survey and a frequency analysis was done. The analysis objects were survey papers (n=2,754pcs) answered by random ordinary citizens chosen from all over the country. The questionnaires, and study tool, were directly distributed and collected. A total of 40 questionnaires using a coefficient of Cronbach's ${\alpha}$ per each area was 'self perception of radiation' (0.620), 'radiation risk' (0.830), 'benefit from radiation' (0.781), 'radiation controlled' (0.685), 'informative source of radiation' (0.831), 'influence degree from Fukushima accident' (0.763), showing rather high score from all areas. As the result of the questionnaires, the knowledge of radiation concept was 69.50 out of 100 points, which shows a rather significant difference from the result of 'know well about radiation' (53.7%) and 'just know about radiation' (37.40%). According to the survey, one of the main reasons why radiation seems risky was that once exposed to radiation, it may not have negative impacts presently but, the next generation could see negative impacts (66.1%). About 41% of our respondents showed a negative position against the government's report on radiation while 39.5% of respondents said that we should stop running nuclear power in light of Fukushima nuclear power plant accident. This study was done for the first time by Korean people's public perception on radiation after the Fukushima nuclear power plant accident. We expect this might have significant contributions to the establishment of the government's policy on radiation.

The Study of Shielding Effect on Ovoids of Three Different Gynecological Applicator Sets in microSelectron-HDR System (microSelectron-HDR System에서 부인암 강내조사에 쓰이는 세 가지 Applicator Set들의 Ovoids에 대한 차폐효과 연구)

  • Cho, Young-K.;Park, Sung-Y.;Choi, Jin-H.;Kim, Hung-J.;Kim, Woo-C.;Loh, John-J.K.;Kim, Joo-Y.
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.4
    • /
    • pp.259-266
    • /
    • 1998
  • There are three different types of gynecological applicator sets available in microSelectron-high dose-rate(HDR) System by Nucletron; standard applicator set(SAS), standard shielded applicator set(SSAS), and Fletcher-Williamson applicator set(FWAS). Shielding effect of a SAS without shielding material was compared with that of a SSAS with shielding material made of stainless steel(density ${\varrho}=8,000kg/m^3$) at the top and bottom of each ovoid, and of a FWAS with shielding material made of tungsten alloy(density ${\varrho}=14,000kg/m^3$ at the top and bottom of each ovoid. The shielding effects to the rectum and bladder of these two shielded applicator sets were to be measured at reference points with an ion chamber and specially designed supporting system for applicator ovoids inside of the computerized 3-dimensional water phantom. To determine the middle point of two ovoids the measurement was performed with the reference tip of ion chamber placed at the same level and at the middle point from the two ovoids, while scanning the dose with the ion chamber on each side of ovoids. The doses to the reference points of rectum were measured at 20(Rl), 25(R2), 30(R3), 40(R4), 50(R5), and 60(R6) mm located posteriorly on the vertical line drawn from M5(the middle dwell position of ovoid), and the doses to the bladder were measured at 20(Bl), 30(B2), 40(B3), 50(B4), and 60(B5) mm located anteriorly on the vertical line drawn from M5. The same technique was employed to measure the doses on each reference point of both SSAS and FWAS. The differences of measured rectal doses at 25 mm(R2) and 30 mm(R3) between SAS and SSAS were 8.0 % and 6.0 %: 25.0% and 23.0 % between SAS and FWAS. The differences of measured bladder doses at 20 mm(Bl) and 30 mm(B2) between SAS and SSAS were 8.0 % and 3.0 %: 23.0 % and 17.0 % between SAS and FWAS. The maximum shielding effects to the rectum and bladder of SSAS were 8.0 % and 8.0 %, whereas those of FWAS were 26.0 % and 23.0 %, respectively. These results led to the conclusion that FWAS has much better shielding effect than SSAS does, and when SSAS and FWAS were used for gynecological intracavitary brachytherapy in microSelectron-HDR system, the dose to the rectum and bladder was significantly reduced to optimize the treatment outcome and to lower the complication rates in the rectum and bladder.

  • PDF

Determination of Phantom Scatter Factors for Small Photon Fields (소조사면 광자선의 팬톰산란인수 결정)

  • Oh, Young-Kee;Choi, Tae-Jin;Kim, Jin-Hee;Kim, Ok-Bae
    • Progress in Medical Physics
    • /
    • v.20 no.2
    • /
    • pp.106-111
    • /
    • 2009
  • Total scatter factor ($S_{cp}$), head scatter factor ($S_c$) and phantom scatter factor ($S_p$) are very important for accurate radiation therapy at stereotactic radiosurgery (SRS) with irregular field shape using micro-MLC and intensity modulated radiation therapy (IMRT) including many small field sizes. In this study we measured and compared $S_{cp}$ with reference ion chamber, pinpoint chamber and diode detector and adapted the resuls form diode detector. Head scatter factors for small field sizes were also measured with diode detector covered 1.5 cm-thick solid water build-up cap. Some errors like as electron contamination of 1~3% were included in the values of Sc but trend of total results of $S_c$ was coincided with basic theory. Phantom scatter factors for small field sizes were calculated form $S_{cp}$ and $S_c$. The results of $S_p$ were compared and were well-agreed with those of other authors.

  • PDF

Comparison between preoperative and postoperative concurrent chemoradiotherapy for rectal cancer: an institutional analysis

  • Lee, Jeong Won;Lee, Jong Hoon;Kim, Jun-Gi;Oh, Seong Taek;Chung, Hyuk Jun;Lee, Myung Ah;Chun, Hoo Geun;Jeong, Song Mi;Yoon, Sei Chul;Jang, Hong Seok
    • Radiation Oncology Journal
    • /
    • v.31 no.3
    • /
    • pp.155-161
    • /
    • 2013
  • Purpose: To evaluate the treatment outcomes of preoperative versus postoperative concurrent chemoradiotherapy (CRT) on locally advanced rectal cancer. Materials and Methods: Medical data of 114 patients with locally advanced rectal cancer treated with CRT preoperatively (54 patients) or postoperatively (60 patients) from June 2003 to April 2011 was analyzed retrospectively. 5-Fluorouracil (5-FU) or a precursor of 5-FU-based concurrent CRT (median, 50.4 Gy) and total mesorectal excision were conducted for all patients. The median follow-up duration was 43 months (range, 16 to 118 months). The primary end point was disease-free survival (DFS). The secondary end points were overall survival (OS), locoregional control, toxicity, and sphincter preservation rate. Results: The 5-year DFS rate was 72.1% and 48.6% for the preoperative and postoperative CRT group, respectively (p = 0.05, the univariate analysis; p = 0.10, the multivariate analysis). The 5-year OS rate was not significantly different between the groups (76.2% vs. 69.0%, p = 0.23). The 5-year locoregional control rate was 85.2% and 84.7% for the preoperative and postoperative CRT groups (p = 0.98). The sphincter preservation rate of low-lying tumor showed significant difference between both groups (58.1% vs. 25.0%, p = 0.02). Pathologic tumor and nodal down-classification occurred after the preoperative CRT (53.7% and 77.8%, both p < 0.001). Acute and chronic toxicities were not significantly different between both groups (p=0.10 and p = 0.62, respectively). Conclusion: The results confirm that preoperative CRT can be advantageous for improving down-classification rate and the sphincter preservation rate of low-lying tumor in rectal cancer.

Small Bowel Sparing Effect of Small Bowel Displacement System in 3D-CRT and IMRT for Cervix Cancer (자궁경부암의 3D-CRT와 IMRT시 소장전위장치의 소장 선량에 대한 영향)

  • Kang, Min-Kyu;Huh, Seung-Jae;Han, Young-Yih;Park, Won;Ju, Sang-Gyu;Kim, Kyoung-Ju;Lee, Jeung-Eun;Park, Young-Je;Nam, Hee-Rim;Lim, Do-Hoon;Ahn, Yong-Chan
    • Radiation Oncology Journal
    • /
    • v.22 no.2
    • /
    • pp.130-137
    • /
    • 2004
  • Purpose : In radiotherapy for cervix cancer, both 3-dimensioal radiotherapy (3D-CRT) and intensity-modulated radiation therapy (IMRT) could reduce the dose to the small bowel (SB), while the small bowel displacement system (SBDS) could reduce the SB volume in the pelvic cavity. To evaluate the effect of the SBDS on the dose to the SB in 3D-CRT and IMRT plans, 3D-CRT and IMRT plans, with or without SBDS, were compared. Materials and Methods : Ten consecutive uterine cervix cancer patients, receiving curative radiotherapy, were accrued. Ten pairs of computerized tomography (CT) scans were obtained in the prone position, with or without SBDS, which consisted of a Styrofoam compression device and an individualized custom-made abdominal immobilization device. Both 3D-CRT, using the 4-field box technique, and IMRT plans, with 7 portals of 15 MV X-ray, were generated for each CT image, and proscribed 50 Gy (25 fractions) to the isocenter. For the SB, the volume change due to the SBDS and the DVHs of the four different plans were analyzed using palled t-tests. Results : The SBDS significantly reduced the mean SB volume from 522 to 262 cm$^{3}$ (49.8$\%$ reduction). The SB volumes that received a dose of 10$\~$50 Gy were significantly reduced in 3D-CRT (65$\~$80$\%$ reduction) and IMRT plans (54$\~$67$\%$ reduction) using the SBDS. When the SB volumes that received 20$\~$50 Gy were compared between the 3D-CRT and IMRT plans, those of the IMRT without the SBDS were significantly less, by 6$\~$7$\%$, than those for the 3D-CRT without the SBDS, but the volume difference was less than 1$\%$ when using the SBDS. Conclusion : The SBDS reduced the radiation dose to the SB in both the 3D-CRT and IMRT plans, so could reduce the radiation injury of the SB.

The Effects of $Sb_2O_3$ on the Radiation Properties of a Far-Infrared in Semiconducting PTC Thermistor (반도성 PTC 서미스터의 원적외선 방사특성에 미치는 $Sb_2O_3$의 영향)

  • Cho, H.S.;Song, M.J.;Shin, Y.D.;Jang, S.H.;Park, C.B.
    • Proceedings of the KIEE Conference
    • /
    • 1991.11a
    • /
    • pp.278-281
    • /
    • 1991
  • 1) The specimen with 0.175[mol%] of additive $Sb_2O_3$ was minute and didn't appear porosity. The relation between the ratio of resistivity at $160^{\circ}C$ to that at $121^{\circ}C$ of the specimen with 0.175[mol%] of additive $Sb_2O_3$ was $3{\times}10^4$ and it's great value from among specimens. 2) The curie temperature of the specimen with 0.2 [mol%] of additive $Sb_2O_3$ was $140^{\circ}C$ AND it's great value from among specimens and those of other were $121^{\circ}C$ in all therefore, the specimen with above 0.2[mol%] of additive $Sb_2O_3$ is not match for PTCR 3) The variation of radiation properties of the specimen with 0.2[mol%] of additive $Sb_2O_3$ was very steep in the range of far-infrared $5{\sim}10[{\mu}m]$ but radiation percentage was very high of 0.92 in the range of $10[{\mu}m]$.

  • PDF

Effect of Natural Ingredients and Red Wine for Manufacturing Meat Products on Radiation Sensitivity of Pathogens Inoculated into Ground Beef (식육제품 제조용 천연 부재료 및 적색 와인이 분쇄 우육에 접종된 병원성 미생물의 방사선 감수성에 미치는 영향)

  • Yun, Hye-Jeong;Kim, Hyun-Joo;Jung, Yeon-Kook;Jung, Samooel;Lee, Ju-Woon;Jo, Cheo-Run
    • Food Science of Animal Resources
    • /
    • v.30 no.5
    • /
    • pp.819-825
    • /
    • 2010
  • This study was conducted to investigate the effect of various natural ingredients for manufacturing meat products on the $D_{10}$ value and relative radiation sensitivity (RRS) of foodborne pathogens inoculated into ground beef. The pathogens used for this study were Salmonella Typhimurium (KCTC 1925), Escherichia coli (KCTC 41682), Listeria monocytoges (KCTC 3569), and Staphylococcus aureus (KCTC 11764), and the natural ingredients added into ground beef were garlic, onion, black pepper, hot pepper, ginger, green onion, carrot, and red wine. The $D_{10}$ of E. coli was decreased significantly by 5% of garlic addition (RRS=1.460), and the addition of carrot (RRS=1.086) and red wine (RRS=2.864) also showed similar results. Most natural ingredients were effective in increasing radiation sensitivity of L. monocytogens, but only garlic, onion, hot pepper, carrot, and red wine were effective against S. aureus. In particular, the addition of red wine to ground beef showed the greatest increase of radiation sensitivity for 3 pathogens tested in the present study, except for S. Typhimurium. Results indicate that the use of certain natural ingredients for manufacturing processed meat products may have effects in the increase of radiation sensitivity of pathogens. This increased radiation sensitivity can reduce the target irradiation dose for obtaining the same level of safety, resulting in lowering the adverse quality changes caused by a high-dose irradiation process.