• Title/Summary/Keyword: S.I.F Calibration

Search Result 11, Processing Time 0.023 seconds

Performance of a Bayesian Design Compared to Some Optimal Designs for Linear Calibration (선형 캘리브레이션에서 베이지안 실험계획과 기존의 최적실험계획과의 효과비교)

  • 김성철
    • The Korean Journal of Applied Statistics
    • /
    • v.10 no.1
    • /
    • pp.69-84
    • /
    • 1997
  • We consider a linear calibration problem, $y_i = $$\alpha + \beta (x_i - x_0) + \epsilon_i$, $i=1, 2, {\cdot}{\cdot},n$ $y_f = \alpha + \beta (x_f - x_0) + \epsilon, $ where we observe $(x_i, y_i)$'s for the controlled calibration experiments and later we make inference about $x_f$ from a new observation $y_f$. The objective of the calibration design problem is to find the optimal design $x = (x_i, \cdots, x_n$ that gives the best estimates for $x_f$. We compare Kim(1989)'s Bayesian design which minimizes the expected value of the posterior variance of $x_f$ and some optimal designs from literature. Kim suggested the Bayesian optimal design based on the analysis of the characteristics of the expected loss function and numerical must be equal to the prior mean and that the sum of squares be as large as possible. The designs to be compared are (1) Buonaccorsi(1986)'s AV optimal design that minimizes the average asymptotic variance of the classical estimators, (2) D-optimal and A-optimal design for the linear regression model that optimize some functions of $M(x) = \sum x_i x_i'$, and (3) Hunter & Lamboy (1981)'s reference design from their paper. In order to compare the designs which are optimal in some sense, we consider two criteria. First, we compare them by the expected posterior variance criterion and secondly, we perform the Monte Carlo simulation to obtain the HPD intervals and compare the lengths of them. If the prior mean of $x_f$ is at the center of the finite design interval, then the Bayesian, AV optimal, D-optimal and A-optimal designs are indentical and they are equally weighted end-point design. However if the prior mean is not at the center, then they are not expected to be identical.In this case, we demonstrate that the almost Bayesian-optimal design was slightly better than the approximate AV optimal design. We also investigate the effects of the prior variance of the parameters and solution for the case when the number of experiments is odd.

  • PDF

Calibration and Sensitivity Analysis of LRCS Rainfall-Runoff Model(II) : Application (LRCS 강우-유출 모형의 보정 및 민감도 분석(II) : 적용)

  • O, Gyu-Chang;Lee, Gil-Seong;Lee, Sang-Ho
    • Journal of Korea Water Resources Association
    • /
    • v.32 no.6
    • /
    • pp.665-674
    • /
    • 1999
  • This paper confirmed the applicability of model to Korean rivers through the calibration and sensitivity analysis of LRCS rainfall runoff model for 18 storm events of Songriweon station in Nakdong river system, and achieved that LS and WLS were better than LAD by model fitting results. Diagonal element of "hat" matrix and affluence measures were used by analysis of parameter estimates, and parameter IL was the most important parameter in model output. By the results of error propagation according to parameter error, parameters IL, TP, F1 were affected by error propagation, and this is measure of sensitivity for the model output. This paper confirmed the relationship of calibration and sensitivity analysis of model through analysis of sensitivity coefficient, diagonal element $h_i$ and $D_i$._i$.

  • PDF

Dyeability of Nylon Fabrics with Dyestuff for Supercritical Fluid Dyeing (1) : C.I. Disperse Red 167, C.I. Disperse Violet 93 (초임계 유체 염색용 염료에 따른 Nylon 섬유의 염색 특성 (1) : C.I. Disperse Red 167, C.I. Disperse Violet 93 Azo계 염료)

  • Choi, Hyunseuk;Park, Shin;Kim, Taeyoung
    • Textile Coloration and Finishing
    • /
    • v.32 no.4
    • /
    • pp.217-225
    • /
    • 2020
  • In this study, the dyeing characteristics of nylon fabric which is dyed with supercritical fluid were investigated. There were two dyes used in the dyeing experiment: C.I. Disperse Red 167 and C.I. Disperse Violet 93. Dyeing temperature, pressure, and leveling time were fixed at 110℃, 250bar, 60minutes, and the experiment was conducted with dyeing concentration of 0.1, 0.3, 0.5, and 0.85% o.w.f. The analysis of the experimental results was found out through the measurement of washing fastness and color coordinate. In addition, the calibration curve of each dye was drawn up and the amount of remaining dye was checked by measuring the absorbance of the residual dye. As a result of color difference measurement, as the concentration increased, the L⁎ value decreased and the K/S value increased. However, the increase in K/S value compared to the amount of input decreased as the concentration increased. The comparative experiment on the amount of residual dye(C.I. Disperse Red 167) in the pot showed that 99.14% of the amount was dyed at the concentration of 0.1% o.w.f, while it rapidly decreased to 77% at 0.85% o.w.f. C.I. Disperse Violet 93 dye also decreased from 0.5% o.w.f to 93.91%. In the washing fastness experiment of both dyes, the level of washing fastness began to decrease from samples dyed at 0.5% o.w.f. It may be because the simply absorbed dye was produced instead of completely being fixed in the amorphous region of the nylon fiber.

Efficiency calibration and coincidence summing correction for a NaI(Tl) spherical detector

  • Noureddine, Salam F.;Abbas, Mahmoud I.;Badawi, Mohamed S.
    • Nuclear Engineering and Technology
    • /
    • v.53 no.10
    • /
    • pp.3421-3430
    • /
    • 2021
  • Spherical NaI(Tl) detectors are used in gamma-ray spectrometry, where the gamma emissions come from the nuclei with energies in the range from a few keV up to 10 MeV. A spherical detector is aimed to give a good response to photons, which depends on their direction of travel concerning the detector center. Some distortions in the response of a gamma-ray detector with a different geometry can occur because of the non-uniform position of the source from the detector surface. The present work describes the calibration of a NaI(Tl) spherical detector using both an experimental technique and a numerical simulation method (NSM). The NSM is based on an efficiency transfer method (ETM, calculating the effective solid angle, the total efficiency, and the full-energy peak efficiency). Besides, there is a high probability for a source-to-detector distance less than 15 cm to have pulse coincidence summing (CS), which may occur when two successive photons of different energies from the same source are detected within a very short response time. Therefore, γ-γ ray CS factors are calculated numerically for a 152Eu radioactive cylindrical source. The CS factors obtained are applied to correct the measured efficiency values for the radioactive volumetric source at different energies. The results show a good agreement between the NSM and the experimental values (after correction with the CS factors).

A Study of Dyeing Properties of Cotton Fabrics Under Supercritical CO2 Depending on Dyestuff : by C.I. Disperse orange 155, C.I. Disperse red 167 (초임계 유체 염색용 염료에 따른 면 섬유의 염색 특성 : C.I. Disperse orange 155, C.I. Disperse red 167)

  • Choi, Hyunseuk;Kim, Hunmin;Jeon, Taeyoung
    • Textile Coloration and Finishing
    • /
    • v.34 no.2
    • /
    • pp.93-101
    • /
    • 2022
  • In this study, the dyeing properties of supercritical fluid dyed cotton fabrics were investigated which use two types of dyes, such as C.I. Disperse orange and C.I. Disperse red 167. Dyeing temperature, pressure and leveling time were equally applied at 130 ℃, 250 bar, and 60 minutes with reference to the related literature, and experiments were performed at concentrations of 0.04, 0.1, 0.4 and 0.8 % o.w.f with different concentrations. Dyeability was confirmed through measurement of washing fastness and color coordinate, and a calibration curve of each dye was drawn up and the absorbance of the residual dye was measured to confirm the amount of residual dye and the dye exhaustion rate at the corresponding concentration. As a result of color difference measurement, as the concentration increased, the L* value decreased and the K/S value increased. However, as the concentration increased, the increase in K/S value decreased compared to the input amount, and this tendency was more obvious in C.I. Disperse red 167 than in C.I. Disperse orange 155. The dye exhaustion rate which was calculated by using the amount of residual dye in the pot was also C.I. Disperse orange 155 was 96.16 % and C.I. Disperse red 167 was 94.57 %. However, as the dyeing concentration increased, the dye exhaustion rate decreased, that C.I. Disperse orange was 95.33 % and C.I. Disperse red 167 was 90.63 %. As a result of the washing fastness test for both dyes, dyed samples of which concentrations were 0.4 and 0.8 % o.w.f decreased by 0.5 ~ 1.0 grade. This is predicted because the dye did not completely adhere to the amorphous region of the cotton fiber and the dye simply adsorbed. The fastness to rubbing also maintained at least grade 3-4 up to the 0.1 % o.w.f concentration, but at the concentration of 0.4 % o.w.f or higher, it fell to grade 1 or lower, showing a very poor friction fastness.

THE EVOLUTION OF THE GALACTIC GLOBULAR CLUSTERS.: I. METAL ABUNDANCE CALIBRATIONS

  • Lee, See-Woo;Park, Nam-Kyu
    • Journal of The Korean Astronomical Society
    • /
    • v.17 no.2
    • /
    • pp.69-103
    • /
    • 1984
  • Five different calibrations of metal abundances of globular clusters are examined and these are compared with metallicity ranking parameters such as $(Sp)_c$, . Q39 and IR-indices. Except for the calibration $[Fe/H]_H$ by the high dispersion echelle analysis. the other calibration scales are correlated with the morphological parameters of red giant branch. In the $[Fe/H]_H$-scale. the clusters later than ${\sim}F8$ have nearly a constant metal abundance. $[Fe/H]_H{\simeq}-1.05$, regradless of morphological characteristics of horizontal branch and red giant branch. By the two fundamental calibration scales of $[Fe/H]_L$ (derived by the low dispersion analysis) and $[Fe/H]_{{\Delta}s}$ (derived by the spectral analysis of RR Lyrae stars). the globular clusters are divided into the halo clusters with [Fe/H]<-1.0 and the disk clusters confined within the galactocentric distance ${\tau}_G=10\;kpc$ and galactic plane distance |z|=3 kpc. In this case the abundance gradient is given by d[Fe/H]/$dr_G{\approx}-0.05\;kpc^{-1}$ and d[Fe/H]/$d|z|{\simeq}-0.08\;kpc^{-1}$ within ${\tau}_G=20\;kpc$ and |z|=10 kpc, respectively. According to these characteristics of the spatial distribution of globular clusters. the chemical evolution of the galactic globular clusters can be accounted for by the two-zone (disk-halo) slow collapse model when the $[Fe/H]_L$-or $[Fe/H]_{{\Delta}s}$-scale is applied. In the case of $[Fe/H]_H$-scale, the one-zone fast collapse model is preferred for the evolution of globular clusters.

  • PDF

Evalustion and Prediction for the Fatigue crack Initiation and Growth Life by Reliability Approach (I) -Statistical Consideration for Fatigue Crack Growth Life- (신뢰성 공학적 피로 균열의 발생, 진전 수명 평가 및 예측에 관한 연구 ( I ) -피로 균열 진전 수명의 통계학적 분포 특성-)

  • 권재도;최선호;황재석;곽상국;전경옥;장재영
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.6
    • /
    • pp.1583-1591
    • /
    • 1990
  • Life prediction and residual life prediction of structures of machines are one of the most strongly world wide needed problems as requirement in the stage of slowly developing economy which comes after rapidly and highly developing stage. For the purpose of statistical life prediction, fatigue test was conducted under the 4 stress levels, and for each stress level, about 20 specimens are used. The statistical properties of crack growth parameter m and C in the fatigue crack growth law of da/dN=C(.DELTA.K)sup m/, and the relationship between m and C, and the statistical distribution pattern of fatigue crack growth rate can be obtained by experimental results.

The X-Ray Fluorescent Spectrographic Analysis of Silicate Minerals (X線螢光分析에 依한 珪酸鹽鑛物의 分析)

  • Chan Kuk Kim;Ki Nam Sang;Hwang Am Kim
    • Journal of the Korean Chemical Society
    • /
    • v.13 no.1
    • /
    • pp.49-55
    • /
    • 1969
  • X-ray Fluorescence Spectrographic method has been applied for the rapid determination of main components, such as $SiO_2$, $Al_2O_3$, $Fe_2O_3$, CaO, MgO and $K_2O$ in Silicate Minerals. In this method, Boric Acid was used as a binder after fusion with Lithium Tetraborate in the briquet-making process. The Lithium Flubride, Ammonium di-Hydrogen Phosphate and Ethylene Diamine d-Tartrate crystals were used with Scintillation counter and Gas Flow counter as the detectors. Several influences on this method were discussed, including the particle size of samples and reducing of the matrix effects by dilution with Boric Acid and addition of Lanthanum Oxide with the diluent. In order to test the reproducibility of this method described above, the determination of the same kind of samples were carried out repeatedly, and the results obtained were presented in the table. Calibration curves for each element were presented, and the application of the method was tested with International Rock Standard T-Ⅰ. All the results obtained by X-Ray Fluorescence Spectrographic method were compared with the results by conventional chemical method.

  • PDF

Modeling of Estimating Soil Moisture, Evapotranspiration and Yield of Chinese Cabbages from Meteorological Data at Different Growth Stages (기상자료(氣象資料)에 의(依)한 배추 생육시기별(生育時期別) 토양수분(土壤水分), 증발산량(蒸發散量) 및 수량(收量)의 추정모형(推定模型))

  • Im, Jeong-Nam;Yoo, Soon-Ho
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.21 no.4
    • /
    • pp.386-408
    • /
    • 1988
  • A study was conducted to develop a model for estimating evapotranspiration and yield of Chinese cabbages from meteorological factors from 1981 to 1986 in Suweon, Korea. Lysimeters with water table maintained at 50cm depth were used to measure the potential evapotranspiration and the maximum evapotranspiration in situ. The actual evapotranspiration and the yield were measured in the field plots irrigated with different soil moisture regimes of -0.2, -0.5, and -1.0 bars, respectively. The soil water content throughout the profile was monitored by a neutron moisture depth gauge and the soil water potentials were measured using gypsum block and tensiometer. The fresh weight of Chinese cabbages at harvest was measured as yield. The data collected in situ were analyzed to obtain parameters related to modeling. The results were summarized as followings: 1. The 5-year mean of potential evapotranspiration (PET) gradually increased from 2.38 mm/day in early April to 3.98 mm/day in mid-June, and thereafter, decreased to 1.06 mm/day in mid-November. The estimated PET by Penman, Radiation or Blanney-Criddle methods were overestimated in comparison with the measured PET, while those by Pan-evaporation method were underestimated. The correlation between the estimated and the measured PET, however, showed high significance except for July and August by Blanney-Criddle method, which implied that the coefficients should be adjusted to the Korean conditions. 2. The meteorological factors which showed hgih correlation with the measured PET were temperature, vapour pressure deficit, sunshine hours, solar radiation and pan-evaporation. Several multiple regression equations using meteorological factors were formulated to estimate PET. The equation with pan-evaporation (Eo) was the simplest but highly accurate. PET = 0.712 + 0.705Eo 3. The crop coefficient of Chinese cabbages (Kc), the ratio of the maximum evapotranspiration (ETm) to PET, ranged from 0.5 to 0.7 at early growth stage and from 0.9 to 1.2 at mid and late growth stages. The regression equation with respect to the growth progress degree (G), ranging from 0.0 at transplanting day to 1.0 at the harvesting day, were: $$Kc=0.598+0.959G-0.501G^2$$ for spring cabbages $$Kc=0.402+1.887G-1.432G^2$$ for autumn cabbages 4. The soil factor (Kf), the ratio of the actual evapotranspiration to the maximum evapotranspiration, showed 1.0 when the available soil water fraction (f) was higher than a threshold value (fp) and decreased linearly with decreasing f below fp. The relationships were: Kf=1.0 for $$f{\geq}fp$$ Kf=a+bf for f$$I{\leq}Esm$$ Es = Esm for I > Esm 6. The model for estimating actual evapotranspiration (ETa) was based on the water balance neglecting capillary rise as: ETa=PET. Kc. Kf+Es 7. The model for estimating relative yield (Y/Ym) was selected among the regression equations with the measured ETa as: Y/Ym=a+bln(ETa) The coefficients and b were 0.07 and 0.73 for spring Chinese cabbages and 0.37 and 0.66 for autumn Chinese cabbages, respectively. 8. The estimated ETa and Y/Ym were compared with the measured values to verify the model established above. The estimated ETa showed disparities within 0.29mm/day for spring Chinese cabbages and 0.19mm/day for autumn Chinese cabbages. The average deviation of the estimated relative yield were 0.14 and 0.09, respectively. 9. The deviations between the estimated values by the model and the actual values obtained from three cropping field experiments after the completion of the model calibration were within reasonable confidence range. Therefore, this model was validated to be used in practical purpose.

  • PDF

STATUS AND PROGRESS OF ARGO-M SYSTEM DEVELOPMENT (인공위성 레이저추적 시스템(ARGO-M) 개발 현황)

  • Park, Eun-Seo;Yu, S.Y.;Lim, H.C.;Bang, S.C.;Seo, Y.K.;Park, J.H.;Jo, J.H.;Park, J.U.;Nah, J.K.;Jang, J.G.;Jang, B.H.;Kim, K.D.;Kim, B.I.;Park, C.H.;Lee, S.H.;Ham, S.Y.;Son, Y.S.
    • Publications of The Korean Astronomical Society
    • /
    • v.27 no.3
    • /
    • pp.49-59
    • /
    • 2012
  • KASI (Korea Astronomy and Space Science Institute) has developed an SLR (Satellite Laser Ranging) system since 2008. The name of the development program is ARGO (Accurate Ranging system for Geodetic Observation). ARGO has a wide range of applications in the satellite precise orbit determination and space geodesy research using SLR with mm-level accuracy. ARGO-M (Mobile, bistatic 10 cm transmitting/40 cm receiving telescopes) and ARGO-F (Fixed stationary, about 1 m transmitting/receiving integrated telescope) SLR systems development will be completed by 2014. In 2011, ARGO-M system integration was completed. At present ARGO-M is in the course of system calibration, functionality, and performance tests. It consists of six subsystems, OPS (Optics System), TMS (Tracking Mount System), OES (Opto-Electronic System), CDS (Container-Dome System), LAS (Laser System) and AOS (ARGO Operation System). In this paper, ARGO-M system structure and integration status are introduced and described.