• 제목/요약/키워드: S.C. charging mode

검색결과 13건 처리시간 0.025초

A High Frequency-Link Bidirectional DC-DC Converter for Super Capacitor-Based Automotive Auxiliary Electric Power Systems

  • Mishima, Tomokazu;Hiraki, Eiji;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • 제10권1호
    • /
    • pp.27-33
    • /
    • 2010
  • This paper presents a bidirectional DC-DC converter suitable for low-voltage super capacitor-based electric energy storage systems. The DC-DC converter presented here consists of a full-bridge circuit and a current-fed push-pull circuit with a high frequency (HF) transformer-link. In order to reduce the device-conduction losses due to the large current of the super capacitor as well as unnecessary ringing, synchronous rectification is employed in the super capacitor-charging mode. A wide range of voltage regulation between the battery and the super capacitor can be realized by employing a Phase-Shifting (PS) Pulse Width Modulation (PWM) scheme in the full-bridge circuit for the super capacitor charging mode as well as the overlapping PWM scheme of the gate signals to the active power devices in the push-pull circuit for the super capacitor discharging mode. Essential performance of the bidirectional DC-DC converter is demonstrated with simulation and experiment results, and the practical effectiveness of the DC-DC converter is discussed.

Energy Storage Characteristics In Fixed Beds (Charging, Storing, Discharging)

  • Hassanein, Soubhi A.;Choi, Sang-Min
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2004년도 제29회 KOSCI SYMPOSIUM 논문집
    • /
    • pp.17-23
    • /
    • 2004
  • In the present work, the numerical model was refined to predict the thermal analysis of energy storage in a fixed beds during (charging ,storing, discharging) mode. The governing energy equations of both fluid and the solid particles along with their initial and boundary conditions are derived using a two-phase, one dimensional model. The refined model is carried out by taking into account change of (air density , air specific heat) with air temperature and also by taking into considerations heat losses from bed to surrounding. Finite difference method was used to obtain solution of two governing energy equations of both fluid and solid particles through a computer program especially constructed for this purpose. The temperature field for the air and the solid are obtained, also efficiency of energy stored inside the bed is computed. Finally using refined model the effect of air flow rate per unit area Ga (0.2, 0.3, and 0.4 kg/$m^2$-s), and inlet air temperature (200, 250, 300 $^{\circ}C$) on energy storage characteristics was studied in three mode ( charging ,storing, discharging). The rock particles of diameter 1 em is used as bed material in this research.

  • PDF

Analysis of the Charging Characteristics of High Voltage Capacitor Chargers Considering the Transformer Stray Capacitance

  • Lee, Byungha;Cha, Hanju
    • Journal of Power Electronics
    • /
    • 제13권3호
    • /
    • pp.329-338
    • /
    • 2013
  • In this paper, the charging characteristics of series resonant type high voltage capacitor chargers considering the transformer stray capacitance have been studied. The principles of operation for the four operational modes and the mode changes for the four different switching frequency sections are explained and analyzed in the range of switching frequency below the resonant frequency. It is confirmed that the average charging currents derived from the above analysis results have non-linear characteristics in each of the four modes. The resonant current, resonant voltage, charging current, and charging time of this capacitor charger as variations of the switching frequency, series parallel capacitance ratio ($k=C_p/C_s$), and output voltage are calculated. From the calculation results, the advantages and disadvantages arising from the parallel connection of this stray capacitance are described. Some methods to minimize charging time of this capacitor charger are suggested. In addition, the results of a comparative test using two transformers whose stray capacitances are different are described. A 1.8 kJ/s prototype capacitor charger is assembled with a TI28335 DSP controller and a 40 kJ, 7 kV capacitor. The analysis results are verified by the experiment.

태양광 저에너지 출력을 위한 Buck, Boost 컨버터 구동방식 (Buck and Boost Photovoltaic Converter Driving Schemes under Low power level)

  • 김병우;박성준;김광헌;손무헌;조수억;김철우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.669-672
    • /
    • 2005
  • Normally, the buck converter is used for the charging converter of photovoltaic generator because this converter has good characteristics compare with boost and buck-booster converter But, in case of the sollar-cell voltage is lower than charging voltage, we cannot charge the sollar energy to the charger. So, in this paper, we proposed the novel hybrid converter using by combination of buck and boost converter for the charging converter of photovoltaic generator, as a results, it can operate buck, boost and buck-boost mode. The proposed novel converter has the same characteristics of the existent buck converter and furthermore it can operate as a boost converter. So, we can make the more effective photovoltaic charging system.

  • PDF

A Capacitor-Charging Power Supply Using a Series-Resonant Three-Level Inverter Topology

  • Song I. H.;Shin H. S.;Choi C. H.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.301-303
    • /
    • 2001
  • In this paper we present a Capacitor Charging Power Supply (CCPS) using a series-resonant three-level inverter topology to improve voltage regulation and use semiconductor switches having low blocking voltage capability such as MOSFETs. This inverter can be operated with two modes, Full Power Mode (FPM) and Half Power Mode (HPM). In FPM inverter supplies the high frequency step up transformer with full DC-link voltage and in HPM with half DC-link voltage. HPM switching method will be adopted when CCPS output voltage reaches the preset target value and operates in refresh mode-charge is maintained on the capacitor. In this topology each semiconductor devices blocks a half of the DC-link voltage[2]. A 15kW, 30kV CCPS has been built and will be tested for an electric precipitator application. The CCPS operates from an input voltage of 500VDC and has a variable output voltage between 10 to 30kV and 1kHz repetition rate at 44nF capacitive load [3]. A resonant frequency of 67.9kHz was selected and a voltage regulation of $0.83\%$ has been achieved through the use of half power mode without using the forced cut off the switch current [1]. The theory of operation, circuit topology and test results are given.

  • PDF

전기수력학적 미립화에서 액적 형성에 영향을 미치는 인자에 관한 실험적 연구 (A Study on Influence Factors on Drop Formation in Electrohydrodynamic Atomization)

  • 성기안;이창식
    • 한국분무공학회지
    • /
    • 제8권2호
    • /
    • pp.24-30
    • /
    • 2003
  • An experimental study was performed to investigate the influence factors of drop formation in electrohydrodynamic atomization. The mode of electrohydrodynamic atomization depended on the various factors such as the flow rate of the liquid, the inner diameter of the nozzle, the distance between the nozzle tip and the ground electrode, the shape of the ground electrode. and the applied high voltage. This work was performed to investigate the experimental analysis for the flow pattern visualization of droplets, and the relationship between voltage application and the behavior of liquid atomization. Uniform drops of different sizes can be obtained at the inception of the spindle mode by charging the flow rate and the electric field. The drop size also decreased when the flow rate was raised for the spindle mode. The whipping motion occurred beyond 7kV and before the corona started to take effect.

  • PDF

다이나믹 UPS의 모드별 동작특성 분석 (Analysis of Operating Mode Characteristics of Dynamic UPS)

  • 이기수;김중원;변우열;노의철;김인동;전태원;김흥근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1257-1259
    • /
    • 2004
  • This paper deals with the operation of a flywheel energy storage UPS. The operating principle of the UPS is analysed in each mode including charging, voltage compensation, discharging, and voltage unbalance compensation. The usefulness of the operation is proved through simulations.

  • PDF

전기수력학적 미립화에서 교류 주파수가 액적 분열에 미치는 영향 (Influence of AC Frequency on the Liquid Breakup in Electrohydrodynamic Atomization)

  • 성기안;이창식
    • 한국분무공학회지
    • /
    • 제9권2호
    • /
    • pp.41-49
    • /
    • 2004
  • Liquid breakup under the variation of AC frequency has been studied experimentally in the electrohydrodynamic atomization. The effect of parameters such as charging voltage, flow rate, nozzle tip inner diameter and power frequency have been considered. This work was performed to investigate the experimental analysis for the effect of AC frequency on breakup process, the mapping of occurrence of disintegration region, and the relationship between the applied power and the droplet radius. The experimental results show that the increase of applied voltage in a certain frequency band leads to a reduction in the droplet size within the limits from 50Hz to 400Hz. The transition phenomena from dripping mode to spindle mode were observed under the band of sudden fall of droplet radius changing ratio, and the synchronous region were produced within the range of applied voltage from 5kV to 6kV.

  • PDF

발전기 운전조건을 고려한 조상설비계획 (Shunt Compensator Planning considering generator's operating condition)

  • 이철휴;이상호;박종근;이송근;김홍균;이석진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1496-1498
    • /
    • 1999
  • The line charging is becoming larger due to the expansion of underground cable and extra high voltage lines. It causes reactive power surplus at light load condition which may force generators to operate reluctantly in the under excited mode. This paper proposes the pratical criteria and methodolgy for the shunt reactor planning while suppressing generator's under excited operation.

  • PDF

플라이휠 저장 에너지를 이용한 무순단 전압보상 기능을 갖는 UPS (Flywheel Energy Storage UPS with Voltage Compensation)

  • 이기수;김중원;변우열;노의철;김인동;전태원;김흥근
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2004년도 전력전자학술대회 논문집(2)
    • /
    • pp.592-596
    • /
    • 2004
  • This paper deals with the operation of a flywheel energy storage UPS. The ups has good features such as long life-time, improved efficiency, no environment problems, reduced size and space, and low maintenance cost compared with the conventional UPS using battery. The operating principle of the UPS is analysed in each mode including charging, voltage compensation, discharging, and voltage unbalance compensation. Especially, the tracking characteristic of the disturbed phase of the source voltage after outage is analysed. The usefulness of the operation is proved through simulations.

  • PDF