• Title/Summary/Keyword: S-band

Search Result 4,768, Processing Time 0.044 seconds

A Newly Designed a TiO2-Loaded Spherical ZnS Nano/Micro-Composites for High Hydrogen Production from Methanol/Water Solution Photo-Splitting

  • Kim, Ji-Eun;Kang, Mi-Sook
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.7
    • /
    • pp.2133-2139
    • /
    • 2012
  • A new system using $TiO_2$ (nano-sized, band-gap 3.14 eV)-impregnated spherical ZnS (micro-sized, band-gap 2.73 eV) nano/micro-composites (Ti 0.001, 0.005, 0.01, and 0.05 mol %/ZnS) was developed to enhance the production of hydrogen from methanol/water splitting. The ZnS particles in a spherical morphology with a diameter of about 2-4 mm which can absorb around 455 nm were prepared by hydrothermal method. This material was used as a photocatalyst with loading by nano-sized $TiO_2$ (20-30 nm) for hydrogen production. The evolution of $H_2$ from methanol/water (1:1) photo splitting over the $TiO_2$/ZnS composite in the liquid system was enhanced, compared with that over pure $TiO_2$ and ZnS. In particular, 1.2 mmol of $H_2$ gas was produced after 12 h when 0.005 mol % $TiO_2$/ZnS nano/micro-composite was used. On the basis of cyclic voltammeter (CV) and UV-visible spectrums results, the high photoactivity was attributed to the larger band gap and the lower LUMO in the $TiO_2$/ZnS composite, due to the decreased recombination between the excited electrons and holes.

A Compact Arbitrary Dual-Band Band-stop Filter Using Composite Right/Left-Handed Transmission Lines (CRLH 전송선을 이용한 소형 이중 대역 대역저지 여파기)

  • Jung, Seung-Back;Yand, Seung-In
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.47 no.5
    • /
    • pp.69-74
    • /
    • 2010
  • In this paper, we proposed a compact arbitrary dual-band band-stop filter using CRLH transmission line. The proposed filter used CRLH transmission line as stub and it developed dual-band band-stop characteristics using non-linear phase response of CRLH transmission line. The size of proposed filter is compact. And it can control arbitrary dual stop band. In this paper, designed band-stop filter at GPS band and ISM band As result, the S(2,1) is about -30dB at GPS band and about -29dB at ISM band. The fabricated filter is very compact. Its dimension is 10mm*15mm.

Multi-Band Rejection Slot-Shaped DGS and Its Equivalent Circuit Model (다중 대역 슬롯형 DGS와 등가 회로 모델)

  • Woo, Duk-Jae
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.5
    • /
    • pp.537-543
    • /
    • 2010
  • This paper presents a slot-shaped defected ground structure(DGS) which has multi-band rejection property. The proposed structure, in which the spiral slot-shaped defects with different size are aligned in the transverse direction to the guiding direction of the coplanar waveguide(CPW), provides multiple resonance frequencies. Compared with the simulated results, the band rejection characteristic is in good agreement with the measurement. Also, an equivalent circuit model of the proposed structure is presented, where the DGS on the ground plane is modeled as LC-resonators. This resonators are inductively coupled to the signal line through mutual inductance. From the equivalent circuit model, multi-band rejection property was derived.

Comparison of Antenna Parameters of R-/S-Band Standard Gain Horn Antennas

  • Kang, Jin-Seob;Kim, Jeong-Hwan;Park, Jeong-Il
    • Journal of electromagnetic engineering and science
    • /
    • v.15 no.4
    • /
    • pp.224-231
    • /
    • 2015
  • A comparison of the antenna parameters for R-band (1.7-2.6 GHz) and S-band (2.6-3.95 GHz) standard gain horn antennas has been performed by the Korea Research Institute of Standards and Science (KRISS), together with seven domestic participants from private companies and public institutions. Its purpose, as a proficiency test program of the 'Antenna Measurement Club' of KRISS, was to check equivalences in antenna parameter measurements between KRISS and the participants, particularly in the R-/S-band, to support antenna manufacturers and end users in Korea. The measurement parameters of this comparison are the power gain, radiation pattern, and reflection coefficient of the traveling standards for R-/S-band pyramidal standard gain horn antennas. The comparison used a gain comparison method and an extrapolation method to measure the power gain of the two traveling standards; the radiation patterns were measured in the far-field region of the transmitting and receiving antennas.

Klystron and Modulator Controller for L-band Industrial Accelerator System (L-band 산업용 가속기 RF 증폭기의 전원장치를 위한 제어기 개발)

  • Kwon, S.J.;Son, Y.G.;Jang, S.D.;Oh, J.S.;Cho, M.H.;NamKung, W.;Jung, K.H.;Lee, K.T.;Park, S.W.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1468-1469
    • /
    • 2007
  • 포항가속기 연구소에서는 RIS 프로젝트 사업과제의 일환인 L-band 산업용 전자빔 가속기의 제작 및 기술개발 연구를 철원의 물리기술연고소 주관으로 수행하고 있다. L-band 산업용 전자빔 가속기는 전자빔에 의한 고분자개질 공정, 농수산물의 멸균 및 의료기기의 멸균 등에 적용이 가능하다. 포항가속기연구소에서는 10 MeV급 산업용 전자빔 조사장치에 적용되는 RF증폭기용 펄스 전원장치인 모듈레이터를 설계, 제작을 하였다. 펄스 전원장치인 이 모듈레이터 시스템은 평균 출력 60 kW, 펄스폭 7 us, 펄스반복율 300 Hz의 L-band 상업용 RF 증폭기 전원장치이며, RF 증폭기로 사용되는 클라이스트론은 Thales 사의 TV2022D를 사용하였다. 본 논문에서는 펄스 전원장치인 모듈레이터의 운전과 인터록을 위한 제어장치의 개발과 제작에 대하여 논하고자 한다.

  • PDF

A Dual-Band Through-the-Wall Imaging Radar Receiver Using a Reconfigurable High-Pass Filter

  • Kim, Duksoo;Kim, Byungjoon;Nam, Sangwook
    • Journal of electromagnetic engineering and science
    • /
    • v.16 no.3
    • /
    • pp.164-168
    • /
    • 2016
  • A dual-band through-the-wall imaging radar receiver for a frequency-modulated continuous-wave radar system was designed and fabricated. The operating frequency bands of the receiver are S-band (2-4 GHz) and X-band (8-12 GHz). If the target is behind a wall, wall-reflected waves are rejected by a reconfigurable $G_m-C$ high-pass filter. The filter is designed using a high-order admittance synthesis method, and consists of transconductor circuits and capacitors. The cutoff frequency of the filter can be tuned by changing the reference current. The receiver system is fabricated on a printed circuit board using commercial devices. Measurements show 44.3 dB gain and 3.7 dB noise figure for the S-band input, and 58 dB gain and 3.02 dB noise figure for the X-band input. The cutoff frequency of the filter can be tuned from 0.7 MHz to 2.4 MHz.

Electrophoresis Techniques for Identification of Callus Induced from Pinella ternata (Thunb.) Breit 1. Analysis of protein and Enzymes of Callus Induced from Pinella ternata (Thunb.) Breit (기내 배양된 반하의 전기영동에 의한 생약학적 연구 1. 전기영동법에 의한 반하 Callus의 단백질 및 효소분석)

  • Choi, Jung-Sik;Ryu, Jeom-Ho;Park, Hak-Bong;Kim, Hyung-Moo
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.33 no.2
    • /
    • pp.122-125
    • /
    • 1988
  • A comparative electrophoretic study on protein and several important enzymes of calli induced from stem, intercostal area and minor vein area were conducted in Pinella ternata (Thunb.) Breit. Soluble protein band patterns of calli induced from stem, intercostal area and minor vein area were distinctly different from those of the corresponding plant parts. Esterase isozyme patterns of calli induced from stem, intercostal area and minor vein area were different from those of the corresponding plant parts. Glutamate oxalo-acetate transaminase isozyme patterns of calli grown for 4 weeks induced from 3 plant parts were similar to those of the corresponding plant parts. But a high molecular weight isozyme band appeared in the calli grown for 8 weeks. Alow molecular weight isozyme band disappeared on the peroxidase isozyme patterns of calli grown for 4 weeks appeared on those of the corresponding plant parts.

  • PDF

Design and Implementation of Dual Wideband Dipole Type Antenna for the Reception of S-DMB and 2.4/5 GHz WLAN Signals (S-DMB와 2.4/5 GHz WLAN 신호 수신을 위한 이중 광대역 다이폴형 안테나의 설계 및 구현)

  • Kim, Sung-Min;Yang, Woon-Geun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.11 s.114
    • /
    • pp.1021-1029
    • /
    • 2006
  • In this paper, we designed and implemented a dual wideband dipole type antenna for the reception of S-DMB (Satellite Digital Multimedia Broadcasting) and 2.4/5 GHz WLAN(Wireless Local Area Network) signals. The proposed antenna based on conventional monopole type dual band antenna was implemented as planar wideband dipole type antenna with the volume of $8{\times}33.8{\times}1.68mm^3$. The proposed antenna is printed type on FR4 substrate of 1.6 mm thick and composed of a dipole type antenna for low frequency band and two symmetric structured resonance elements for high frequency band. We confirmed antenna area with dense surface current for each frequency band with simulation. By varying the length of the antenna area with dense surface current, we could vary resonance frequency of each frequency band separately. Impedance bandwidths$(VSWR{\leq}2)$ are 362 MHz(14.23 %) for 2 GHz band and 1188 MHz(22.13, %) for 5 GHz band which show wideband characteristic. Measured maximum gains were 4.33 dBi for 2 GHz band and 5.48 dBi for 5 GHz band which showed improved performance. And the implemented antenna has a good omni-directional radiation pattern characteristic.

Experiences with Endoscopic Interventions for Variceal Bleeding in Children with Portal Hypertension: A Single Center Study

  • Kim, Seung Jin;Oh, Seak Hee;Jo, Jin Min;Kim, Kyung Mo
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.16 no.4
    • /
    • pp.248-253
    • /
    • 2013
  • Purpose: The aim of this study was to compare the efficacy and safety of band ligation and injection sclerotherapy in the endoscopic treatment of children with variceal bleeding. Methods: The study population included 55 children, all of whom were treated at the time of endoscopic diagnosis of esophageal varices at Asan Medical Center, Seoul, Korea, between January 1994 and January 2011. The primary outcomes included initial success rates and duration of hemostasis after endoscopic management (band ligation vs. injectionsclerotherapy). Results: The mean age was $6.7{\pm}5.2$ years and the mean follow-up time was $5.4{\pm}3.7$ years. The most common cause of esophageal varices was biliary atresia. Of 55 children with acute variceal bleeding, 39 had band ligation and 16 had injection sclerotherapy. No differences between groups were observed in terms of the size, location, and presence of red color sign. The success rates of band ligation and sclerotherapy in the control of acute bleeding episodes were 89.7% and 87.5%. The mean duration of hemostasis after endoscopic intervention was $13.2{\pm}25.1$ months. After one year, 19 of 39 patients (48.7%) treated with band ligation and 7 of 16 patients (43.8%) with injection sclerotherapy had experienced rebleeding episodes. Complications after the procedures were observed in 10.3% and 18.8% of children treated with band ligation and injection sclerotherapy. Conclusion: The results of our current study suggest that band ligation and injection sclerotherapy are equally efficient treatments for the control of acute variceal bleeding and prevention of rebleeding.