• Title/Summary/Keyword: S-N line

Search Result 872, Processing Time 0.032 seconds

Antioxidant and Anti-inflammatory Effects of Ficus erecta var. sieboldii Leaf Extract in Murine Macrophage RAW 264.7 Cells (좁은잎천선과나무(Ficus erecta var. sieboldii) 잎 추출물이 대식세포 RAW 264.7 세포에서 미치는 항산화 및 항염증 효과)

  • Jung, Yong-Hwan;Ham, Young-Min;Yoon, Seon-A;Oh, Dae-Ju;Kim, Chang-Suk;Yoon, Weon-Jong
    • Korean Journal of Plant Resources
    • /
    • v.31 no.4
    • /
    • pp.303-311
    • /
    • 2018
  • In this study, a preliminary evaluation of the antioxidant and anti-inflammatory activity of the Ficus erecta var. sieboldii (Miq.) King (FES) leaf extract has been performed to assess its potential as a natural resource for food and medicinal materials. FES was extracted using 70% EtOH and then fractionated sequentially using n-hexane, $CH_2Cl_2$, EtOAc, and n-BuOH. To screen for antioxidant and anti-inflammatory agents effectively, the inhibitory effect of the FES extracts on the production of oxidant stresses (DPPH, xanthine oxidase, and superoxide) and pro-inflammatory factors (NO, iNOS, COX-2, $PGE_2$, IL-6, and $IL-1{\beta}$) in the murine macrophage cell line RAW 264.7 activated with lipopolysaccharide (LPS) was examined. Among the sequential solvent fractions of FES, the $CH_2Cl_2$ and EtOAc fractions showed decreased production of oxidant stresses (DPPH, xanthine oxidase and superoxide), and the hexane and $CH_2Cl_2$ fractions of FES inhibited the production of pro-inflammatory factors (NO, iNOS, COX-2, and $PGE_2$). The $CH_2Cl_2$ fraction also inhibited the production of pro-inflammatory cytokines ($TNF-{\alpha}$, IL-6, and $IL-1{\beta}$). These results suggest that FES has a significant effects on the production of oxidant stresses and pro-inflammatory factors and may be used a natural resource for antioxidant and anti-inflammatory agents.

On-Line Determination Steady State in Simulation Output (시뮬레이션 출력의 안정상태 온라인 결정에 관한 연구)

  • 이영해;정창식;경규형
    • Proceedings of the Korea Society for Simulation Conference
    • /
    • 1996.05a
    • /
    • pp.1-3
    • /
    • 1996
  • 시뮬레이션 기법을 이용한 시스템의 분석에 있어서 실험의 자동화는 현재 많은 연구와 개발이 진행 중인 분야이다. 컴퓨터와 정보통신 시스템에 대한 시뮬레이션의 예를 들어 보면, 수많은 모델을 대한 시뮬레이션을 수행할 경우 자동화된 실험의 제어가 요구되고 있다. 시뮬레이션 수행회수, 수행길이, 데이터 수집방법 등과 관련하여 시뮬레이션 실험방법이 자동화가 되지 않으면, 시뮬레이션 실험에 필요한 시간과 인적 자원이 상당히 커지게 되며 출력데이터에 대한 분석에 있어서도 어려움이 따르게 된다. 시뮬레이션 실험방법을 자동화하면서 효율적인 시뮬레이션 출력분석을 위해서는 시뮬레이션을 수행하는 경우에 항상 발생하는 초기편의 (initial bias)를 제거하는 문제가 선결되어야 한다. 시뮬레이션 출력분석에 사용되는 데이터들이 초기편의를 반영하지 않는 안정상태에서 수집된 것이어야만 실제 시스템에 대한 올바른 해석이 가능하다. 실제로 시뮬레이션 출력분석과 관련하여 가장 중요하면서도 어려운 문제는 시뮬레이션의 출력데이터가 이루는 추계적 과정 (stochastic process)의 안정상태 평균과 이 평균에 대한 신뢰구간(confidence interval: c. i.)을 구하는 것이다. 한 신뢰구간에 포함되어 있는 정보는 의사결정자에게 얼마나 정확하게 평균을 추정할 구 있는지 알려 준다. 그러나, 신뢰구간을 구성하는 일은 하나의 시뮬레이션으로부터 얻어진 출력데이터가 일반적으로 비정체상태(nonstationary)이고 자동상관(autocorrelated)되어 있기 때문에, 전통적인 통계적인 기법을 직접적으로 이용할 수 없다. 이러한 문제를 해결하기 위해 시뮬레이션 출력데이터 분석기법이 사용된다.본 논문에서는 초기편의를 제거하기 위해서 필요한 출력데이터의 제거시점을 찾는 새로운 기법으로, 유클리드 거리(Euclidean distance: ED)를 이용한 방법과 현재 패턴 분류(pattern classification) 문제에 널리 사용 중인 역전파 신경망(backpropagation neural networks: BNN) 알고리듬을 이용하는 방법을 제시한다. 이 기법들은 대다수의 기존의 기법과는 달리 시험수행(pilot run)이 필요 없으며, 시뮬레이션의 단일수행(single run) 중에 제거시점을 결정할 수 있다. 제거시점과 관련된 기존 연구는 다음과 같다. 콘웨이방법은 현재의 데이터가 이후 데이터의 최대값이나 최소값이 아니면 이 데이터를 제거시점으로 결정하는데, 알고기듬 구조상 온라인으로 제거시점 결정이 불가능하다. 콘웨이방법이 알고리듬의 성격상 온라인이 불가능한 반면, 수정콘웨이방법 (Modified Conway Rule: MCR)은 현재의 데이터가 이전 데이터와 비교했을 때 최대값이나 최소값이 아닌 경우 현재의 데이터를 제거시점으로 결정하기 때문에 온라인이 가능하다. 평균교차방법(Crossings-of-the-Mean Rule: CMR)은 누적평균을 이용하면서 이 평균을 중심으로 관측치가 위에서 아래로, 또는 아래서 위로 교차하는 회수로 결정한다. 이 기법을 사용하려면 교차회수를 결정해야 하는데, 일반적으로 결정된 교차회수가 시스템에 상관없이 일반적으로 적용가능하지 않다는 문제점이 있다. 누적평균방법(Cumulative-Mean Rule: CMR2)은 여러 번의 시험수행을 통해서 얻어진 출력데이터에 대한 총누적평균(grand cumulative mean)을 그래프로 그린 다음, 안정상태인 점을 육안으로 결정한다. 이 방법은 여러 번의 시뮬레이션을 수행에서 얻어진 데이터들의 평균들에 대한 누적평균을 사용하기 매문에 온라인 제거시점 결정이 불가능하며, 작업자가 그래프를 보고 임의로 결정해야 하는 단점이 있다. Welch방법(Welch's Method: WM)은 브라운 브리지(Brownian bridge) 통계량()을 사용하는데, n이 무한에 가까워질 때, 이 브라운 브리지 분포(Brownian bridge distribution)에 수렴하는 성질을 이용한다. 시뮬레이션 출력데이터를 가지고 배치를 구성한 후 하나의 배치를 표본으로 사용한다. 이 기법은 알고리듬이 복잡하고, 값을 추정해야 하는 단점이 있다. Law-Kelton방법(Law-Kelton's Method: LKM)은 회귀 (regression)이론에 기초하는데, 시뮬레이션이 종료된 후 누적평균데이터에 대해서 회귀직선을 적합(fitting)시킨다. 회귀직선의 기울기가 0이라는 귀무가설이 채택되면 그 시점을 제거시점으로 결정한다. 일단 시뮬레이션이 종료된 다음, 데이터가 모아진 순서의 반대 순서로 데이터를 이용하기 때문에 온라인이 불가능하다. Welch절차(Welch's Procedure: WP)는 5회이상의 시뮬레이션수행을 통해 수집한 데이터의 이동평균을 이용해서 시각적으로 제거시점을 결정해야 하며, 반복제거방법을 사용해야 하기 때문에 온라인 제거시점의 결정이 불가능하다. 또한, 한번에 이동할 데이터의 크기(window size)를 결정해야 한다. 지금까지 알아 본 것처럼, 기존의 방법들은 시뮬레이션의 단일 수행 중의 온라인 제거시점 결정의 관점에서는 미약한 면이 있다. 또한, 현재의 시뮬레이션 상용소프트웨어는 작업자로 하여금 제거시점을 임의로 결정하도록 하기 때문에, 실험중인 시스템에 대해서 정확하고도 정량적으로 제거시점을 결정할 수 없게 되어 있다. 사용자가 임의로 제거시점을 결정하게 되면, 초기편의 문제를 효과적으로 해결하기 어려울 뿐만 아니라, 필요 이상으로 너무 많은 양을 제거하거나 초기편의를 해결하지 못할 만큼 너무 적은 양을 제거할 가능성이 커지게 된다. 또한, 기존의 방법들의 대부분은 제거시점을 찾기 위해서 시험수행이 필요하다. 즉, 안정상태 시점만을 찾기 위한 시뮬레이션 수행이 필요하며, 이렇게 사용된 시뮬레이션은 출력분석에 사용되지 않기 때문에 시간적인 손실이 크게 된다.

  • PDF

Surrogate Internet Shopping Malls: The Effects of Consumers' Perceived Risk and Product Evaluations on Country-of-Buying-Origin Image (망상대구점(网上代购店): 소비자감지풍험화산품평개대원산국형상적영향(消费者感知风险和产品评价对原产国形象的影响))

  • Lee, Hyun-Joung;Shin, So-Hyoun;Kim, Sang-Uk
    • Journal of Global Scholars of Marketing Science
    • /
    • v.20 no.2
    • /
    • pp.208-218
    • /
    • 2010
  • Internet has grown fast and become one of the most important retail channels now. Various types of Internet retailers, hereafter etailers, have been introduced so far and as one type of Internet shopping mall, 'surrogate Internet shopping mall' has been prosperous and attracting consumers in the domestic market. Surrogate Internet shopping mall is a unique type of etailer that globally purchases well-known brand goods that are not imported in the market, completes delivery in the favor of individual buyers, and collects fees for these specific services. The consumers, who are usually interested in purchasing high-end and unique but not eligible brands, have difficulties to purchase these items overseas directly from the retailers or brands in other countries due to worries of payment failure and no address available for their usually domestic only delivery. In Korea, both numbers of surrogate Internet shopping malls and the magnitude of sales have been growing rapidly up to more than 430 active malls and 500 billion Korean won in 2008 since the population of consumers who want this agent shopping service is also expending. This etail business concept is originated from 'surrogate-mediated purchase' and this type of shopping agent has existed in many different forms and also in wide ranges of context level for quite a long time. As marketers face their individual buyers' representatives instead of a direct contact with them in many occasions, the impact of surrogate shoppers on consumer's decision making has been enormously important and many scholars have explored various range of agent's impact on consumer's purchase decisions in marketing and psychology field. However, not much rigorous research in the Internet commerce has been conveyed yet. Moreover, since as one of the shopping agent surrogate Internet shopping malls specifically connect overseas brands or retailers to domestic consumers, one specific character of the mall's, image of surrogate buying country, where surrogate purchases are conducted in, may play an important role to form consumers' attitude and purchase intention toward products. Furthermore it also possibly affects various dimensions of perceived risk in consumer's information processing. However, though tremendous researches have been carried exploring the effects of diverse dimensions of country of origin, related studies in Internet context has been rarely executed. There have been some studies that prove the positive impact of country of origin on consumer's evaluations as one of information clues in product manufacture descriptions, yet studies detecting the relationship between country image of surrogate buying origin and product evaluations rarely undertaken regarding this specific mall type. Thus, the authors have found it well-worth investigating in this specific retail channel and explored systematic relationships among focal constructs and elaborated their different paths. The authors have proven that country image of surrogate buying origin in the mall, where surrogate malls purchase products in and brings them from for buyers, not only has a positive effect on consumers' product evaluations including attitude and purchase intention but also has a negative effect on all three dimensions of perceived risk: product-related risk, shipping-related risk, and post-purchase risk. Specifically among all the perceived risk, product-related risk which is arisen from high uncertainty of product performance is most affected (${\beta}$= -.30) by negative country image of surrogate buying origin, and also shipping-related risk (${\beta}$= -.18) and post-purchase risk (${\beta}$= -.15) get influenced in order. Its direct effects on product attitude (${\beta}$= .10) and purchase intention (${\beta}$= .14) are also secured. Each of perceived risk dimension is proven to have a negative effect on purchase intention through product attitude as a mediator (${\beta}$= -.57: product-related risk ${\rightarrow}$ product attitude; ${\beta}$= -.24: shipping-related risk ${\rightarrow}$ product attitude; ${\beta}$= -.44: post-purchase risk ${\rightarrow}$ product attitude) as well. From the additional analysis, the paths of consumers' information processing are shown to be different based on their levels of product knowledge. While novice consumers with low level of knowledge consider only perceived risk important, expert consumers with high level of knowledge take both the country image, where surrogate services are conducted in, and perceived risk seriously to build their attitudes and formulate decisions toward products more delicately and systematically, which is in line with previous studies. This study suggests several pieces of academic and practical advice. Precisely, country image of surrogate buying origin does affect on consumer's risk perceptions and behavioral consequences. Therefore a careful selection of surrogate buying origin is recommended. Furthermore, reducing consumers' risk level is required to blossom this new type of retail business whether its consumer are novices or experts. Additionally, since consumer take different paths of elaborating information based on their knowledge levels, sophisticated marketing approaches to each group of consumers are required. For novice buyers strong devices for risk mitigation are needed to induce them to form better attitudes and for experts selections of better and advanced countries as surrogate buying origins are advised while endorsement strategy for the site might work as a reliable information clue to all consumers to mitigate the barriers to purchase goods online. The authors have also explained that the study suffers from some limitations, including generalizability. In future studies, tests of and comparisons among different types of etailers with relevant constructs are recommended to broaden the findings.

A Store Recommendation Procedure in Ubiquitous Market for User Privacy (U-마켓에서의 사용자 정보보호를 위한 매장 추천방법)

  • Kim, Jae-Kyeong;Chae, Kyung-Hee;Gu, Ja-Chul
    • Asia pacific journal of information systems
    • /
    • v.18 no.3
    • /
    • pp.123-145
    • /
    • 2008
  • Recently, as the information communication technology develops, the discussion regarding the ubiquitous environment is occurring in diverse perspectives. Ubiquitous environment is an environment that could transfer data through networks regardless of the physical space, virtual space, time or location. In order to realize the ubiquitous environment, the Pervasive Sensing technology that enables the recognition of users' data without the border between physical and virtual space is required. In addition, the latest and diversified technologies such as Context-Awareness technology are necessary to construct the context around the user by sharing the data accessed through the Pervasive Sensing technology and linkage technology that is to prevent information loss through the wired, wireless networking and database. Especially, Pervasive Sensing technology is taken as an essential technology that enables user oriented services by recognizing the needs of the users even before the users inquire. There are lots of characteristics of ubiquitous environment through the technologies mentioned above such as ubiquity, abundance of data, mutuality, high information density, individualization and customization. Among them, information density directs the accessible amount and quality of the information and it is stored in bulk with ensured quality through Pervasive Sensing technology. Using this, in the companies, the personalized contents(or information) providing became possible for a target customer. Most of all, there are an increasing number of researches with respect to recommender systems that provide what customers need even when the customers do not explicitly ask something for their needs. Recommender systems are well renowned for its affirmative effect that enlarges the selling opportunities and reduces the searching cost of customers since it finds and provides information according to the customers' traits and preference in advance, in a commerce environment. Recommender systems have proved its usability through several methodologies and experiments conducted upon many different fields from the mid-1990s. Most of the researches related with the recommender systems until now take the products or information of internet or mobile context as its object, but there is not enough research concerned with recommending adequate store to customers in a ubiquitous environment. It is possible to track customers' behaviors in a ubiquitous environment, the same way it is implemented in an online market space even when customers are purchasing in an offline marketplace. Unlike existing internet space, in ubiquitous environment, the interest toward the stores is increasing that provides information according to the traffic line of the customers. In other words, the same product can be purchased in several different stores and the preferred store can be different from the customers by personal preference such as traffic line between stores, location, atmosphere, quality, and price. Krulwich(1997) has developed Lifestyle Finder which recommends a product and a store by using the demographical information and purchasing information generated in the internet commerce. Also, Fano(1998) has created a Shopper's Eye which is an information proving system. The information regarding the closest store from the customers' present location is shown when the customer has sent a to-buy list, Sadeh(2003) developed MyCampus that recommends appropriate information and a store in accordance with the schedule saved in a customers' mobile. Moreover, Keegan and O'Hare(2004) came up with EasiShop that provides the suitable tore information including price, after service, and accessibility after analyzing the to-buy list and the current location of customers. However, Krulwich(1997) does not indicate the characteristics of physical space based on the online commerce context and Keegan and O'Hare(2004) only provides information about store related to a product, while Fano(1998) does not fully consider the relationship between the preference toward the stores and the store itself. The most recent research by Sedah(2003), experimented on campus by suggesting recommender systems that reflect situation and preference information besides the characteristics of the physical space. Yet, there is a potential problem since the researches are based on location and preference information of customers which is connected to the invasion of privacy. The primary beginning point of controversy is an invasion of privacy and individual information in a ubiquitous environment according to researches conducted by Al-Muhtadi(2002), Beresford and Stajano(2003), and Ren(2006). Additionally, individuals want to be left anonymous to protect their own personal information, mentioned in Srivastava(2000). Therefore, in this paper, we suggest a methodology to recommend stores in U-market on the basis of ubiquitous environment not using personal information in order to protect individual information and privacy. The main idea behind our suggested methodology is based on Feature Matrices model (FM model, Shahabi and Banaei-Kashani, 2003) that uses clusters of customers' similar transaction data, which is similar to the Collaborative Filtering. However unlike Collaborative Filtering, this methodology overcomes the problems of personal information and privacy since it is not aware of the customer, exactly who they are, The methodology is compared with single trait model(vector model) such as visitor logs, while looking at the actual improvements of the recommendation when the context information is used. It is not easy to find real U-market data, so we experimented with factual data from a real department store with context information. The recommendation procedure of U-market proposed in this paper is divided into four major phases. First phase is collecting and preprocessing data for analysis of shopping patterns of customers. The traits of shopping patterns are expressed as feature matrices of N dimension. On second phase, the similar shopping patterns are grouped into clusters and the representative pattern of each cluster is derived. The distance between shopping patterns is calculated by Projected Pure Euclidean Distance (Shahabi and Banaei-Kashani, 2003). Third phase finds a representative pattern that is similar to a target customer, and at the same time, the shopping information of the customer is traced and saved dynamically. Fourth, the next store is recommended based on the physical distance between stores of representative patterns and the present location of target customer. In this research, we have evaluated the accuracy of recommendation method based on a factual data derived from a department store. There are technological difficulties of tracking on a real-time basis so we extracted purchasing related information and we added on context information on each transaction. As a result, recommendation based on FM model that applies purchasing and context information is more stable and accurate compared to that of vector model. Additionally, we could find more precise recommendation result as more shopping information is accumulated. Realistically, because of the limitation of ubiquitous environment realization, we were not able to reflect on all different kinds of context but more explicit analysis is expected to be attainable in the future after practical system is embodied.

The Study on the Debris Slope Landform in the Southern Taebaek Mountains (태백산맥 남부산지의 암설사면지형)

  • Jeon, Young-Gweon
    • Journal of the Korean Geographical Society
    • /
    • v.28 no.2
    • /
    • pp.77-98
    • /
    • 1993
  • The intent of this study is to analyze the characteristics of distribution, patter, and deposits of the exposed debris slope landform by aerial photography interpretation, measure-ment on the topographical maps and field surveys in the southern part Taebaek mountains. It also aims to research the arrangement types of mountain slope and the landform development of debris slopes in this area. In conclusion, main observations can be summed up as follows. 1. The distribution characteristics 1)From the viewpoint of bedrocks, the distribution density of talus is high in case of the bedrock with high density of joints, sheeting structures and hard rocks, but that of the block stream is high in case of intrusive rocks with the talus line. 2)From the viewpoint of bedrocks, the distribution density of talus is high in case of the bedrock with high density of joints, sheeting structures and hard rocks, but that of the block stream is high in case of inrtusive rocks with the talus line. 2) From the viewpoint of distribution altitude, talus is mainly distributed in the 301~500 meters part above the sea level, while the block stream is distributed in the 101~300 meters part. 3) From the viewpoint of slope oriention, the distribution density of talus on the slope facing the south(S, SE, SW) is a little higher than that of talus on the slope facing the north(N, NE, NW). 2. The Pattern Characteristics 1) The tongue-shaped type among the four types is the most in number. 2) The average length of talus slope is 99 meters, especially that of talus composed of hornfels or granodiorite is longer. Foth the former is easy to make free face; the latter is easdy to produce round stones. The average length of block stream slope is 145 meters, the longest of all is one km(granodiorite). 3) The gradient of talus slope is 20~45${^\circ}$, most of them 26-30${^\croc}$; but talus composed of intrusive rocks is gentle. 4) The slope pattern of talus shows concave slope, which means readjustment of constituent debris. Some of the block stream slope patterns show concave slope at the upper slope and the lower slope, but convex slope at the middle slope; others have uneven slope. 3. The deposit characteristics 1) The average length of constituent debris is 48~172 centimeters in diameter, the sorting of debris is not bad without matrix. That of block stream is longer than that of talus; this difference of debris average diameter is funda-mentally caused by joint space of bedrocks. 2) The shape of constituent debris in talus is mainly angular, but that of the debris composed of intrusive rocks is sub-angular. The shape of constituent debris in block stream is mainly sub-roundl. 3) IN case dof talus, debris diameter is generally increasing with downward slope, but some of them are disordered and the debris diameter of the sides are larger than that of the middle part on a landform surface. In block stream, debris diameter variation is perpendicularly disordered, and the debris diameter of the middle part is generally larger than that of the sides on a landform surface. 4)The long axis orientation of debris is a not bad at the lower part of the slope in talus (only 2 of 6 talus). In block stream(2 of 3), one is good in sorting; another is not bad. The researcher thinks that the latter was caused by the collapse of constituent debris. 5) Most debris were weathered and some are secondly weathered in situ, but talus composed of fresh debris is developing. 4. The landform development of debris slopes and the arrangement types of the mountain slope 1) The formation and development period of talus is divided into two periods. The first period is formation period of talus9the last glacial period), the second period is adjustment period(postglacial age). And that of block stream is divided into three periods: the first period is production period of blocks(tertiary, interglacial period), the second formation period of block stream(the last glacial period), and the third adjustment period of block stream(postglacialage). 2) The arrangement types of mountain slope are divided into six types in this research area, which are as follows. Type I; high level convex slope-free face-talus-block stream-alluvial surface Type II: high level convex slope-free face-talus-alluvial surface Type III: free face-talus-block stream-all-uvial surface Type IV: free face-talus-alluval surface Type V: talus-alluval surface Type VI: block stream-alluvial surface Particularly, type IV id\s basic type of all; others are modified ones.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

Expression of TIMP1, TIMP2 Genes by Ionizing Radiation (이온화 방사선에 의한 TIMP1, TIMP2 유전자 발현 측정)

  • Park Kun-Koo;Jin Jung Sun;Park Ki Yong;Lee Yun Hee;Kim Sang Yoon;Noh Young Ju;Ahn Seung Do;Kim Jong Hoon;Choi Eun Kyung;Chang Hyesook
    • Radiation Oncology Journal
    • /
    • v.19 no.2
    • /
    • pp.171-180
    • /
    • 2001
  • Purpose : Expression of TIMP, intrinsic inhibitor of MMP, is regulated by signal transduction in response to genotoxins and is likely to be an important step in metastasis, angiogenesis and wound healing after ionizing radiation. Therefore, we studied radiation mediated TIMP expression and its mechanism in head and neck cancer cell lines. Materials and Methods : Human head and neck cancer cell lines established at Asan Medical Center were used and radiosensitivity $(D_0)$, radiation cytotoxicity and metastatic potential were measured by clonogenic assay, n assay and invasion assay, respectively. The conditioned medium was prepared at 24 hours and 48 hours after 2 Gy and 10 Gy irradiation and expression of TIMP protein was measured by Elisa assay with specific antibodies against human TIMP. hTIMP1 promoter region was cloned and TIMP1 luciferase reporter vector was constructed. The reporter vector was transfected to AMC-HN-1 and -HN-9 cells with or without expression vector Ras, then the cells were exposed to radiation or PMA, PKC activator. EMSA was peformed with oligonucleotide (-59/-53 element and SP1) of TIMP1 promoter. Results : $D_0$ of HN-1, -2, -3, -5 and -9 cell lines were 1.55 Gy, 1.8 Gy, 1.5 Gt, 1.55 Gy and 2.45 Gy respectively. n assay confirmed cell viability, over $94\%$ at 24hrs, 48hrs after 2 Gy irradiation and over 73% after 10 Gy irradiation. Elisa assay confirmed that cells secreted TIMP1, 2 proteins continuously. After 2 Gy irradiation, TIMP2 secretion was decreased at 24hrs in HN-1 and HN-9 cell lines but after 10 Gy irradiation, it was increased in all cell lines. At 48hrs after irradiation, it was increased in HN-1 but decreased in HN-9 cells. But the change in TIMP secretion by RT was mild. The transcription of TIMP1 gene in HN-1 was induced by PMA but in HN-9 cell lines, it was suppressed. Wild type Ras induced the TIMP-1 transcription by 20 fold and 4 fold in HN-1 and HN-9 respectively. The binding activity to -59/-53, AP1 motif was increased by RT, but not to SP1 motif in both cell lines. Conclusions : We observed the difference of expression and activity of TIMPs between radiosensitive and radioresistant cell line and the different signal transduction pathway between in these cell lines may contribute the different radiosensitivity. Further research to investigate the radiation response and its signal pathway of TIMPs is needed.

  • PDF

Psychological Make-up of Korean Green Consumerism: A Path Model Analysis (한국록색소비심리구성(韩国绿色消费心理构成):일개로경분석모형(一个路径分析模型))

  • Kim, Joo-Ho;Kim, Yeon-Shin
    • Journal of Global Scholars of Marketing Science
    • /
    • v.20 no.3
    • /
    • pp.249-261
    • /
    • 2010
  • As consumers' concern for the environment has continued to increase, many firms have actively engaged in environmental marketing to achieve their objectives. However, consumers' high concerns about the environment are not always reflected in their purchasing behavior. This indicates the need for an in-depth understanding of the development of green consumption within the individual's belief system. In consideration of psychological approaches, a large body of research has examined the factors underlying ecologically conscious "green" consumer behavior and the interrelationships of these factors. However, most previous studies have concentrated on Western countries. Using a sample of Korean consumers, this study attempts to understand the basis of Korean green consumerism and find universal values that are cross-culturally important in guiding consumers' environmental attitudes and behaviors. To this end, this study relates Schwartz's 10 universal values (Schwartz 1992) to environmental behaviors in a hierarchical model of value-attitude-behavior. With reference to the value-attitude-behavior framework, the conceptual model developed for the study explains what motivations can be manifested in Korean consumers' environmental attitudes, and subsequently how the attitudes affect their green choices. Using the pattern of relationships among values that can be related to environmentalism, the first hypothesis holds that there would be particular relationships between motivational value types and environmental attitudes. Hypothesis 2 assumes that environmental attitudes predict environmental behaviors. On the basis of the claim that favorable attitudes toward the environment may be expressed in many different behaviors, the assumption is that consumers' favorable attitudes toward the environment would be linked to a variety of environmental behaviors because people with high environmental attitudes can be more interested in and knowledgeable about environmental actions. Consistent with H2, H3 hypothesizes that there would be a positive relationship between different types of environmental behavior. A total of 564 university students participated in the study. The sample included 308 men, 254 women, and two participants who did not indicate their gender. The average age of the participants was 22.5 years, with a range of 19 to 39. Regarding majors, special efforts were made to draw the participants from different departments of the university. Data were collected by a survey administered via self-completion questionnaires., which assessed the participants' value priorities, environmental attitudes, and behaviors. Path analysis conducted to test the proposed model found the overall fit to be ${\chi}^2$=72.01 (p=0.00), GFI=0.983, CFI=0.982, NFI=0.970, RMR=0.070, and REMSEA=0.050. Thus, most of the fit measures indicated a good fit of the model with the data, and a hierarchical relationship from values to environmental attitudes to environmental non-purchasing behavior to environmental purchasing behavior was confirmed. An assessment of all the predicted paths by path coefficients led to several major hypothesized effects being confirmed. Out of the ten value types, universalism and power were significantly but conversely related to environmental attitudes. In line with the other studies, these findings confirm that environmental attitudes are an important factor in leading to a variety of green behaviors. Finally, significant relationships were found between environmental purchasing and non-purchasing behaviors. The path analysis supported the idea that universalism values provide a motivation for Korean consumers' greenness and indirectly promote environmental acts through favorable attitudes toward the environment. Participants with high environmental attitudes were found to actively engage in diverse forms of green consumer behavior. This research provides an opportunity to examine cross-cultural differences with respect to values leading to environmentalism, and, further, to verify previous findings. The study also examined the attitude-behavior relationship with respect to three distinct types of environmental behaviors. The different strengths of paths between green attitudes and behaviors suggest that researchers should consider the specificity of behavior explained as an effort to improve the low attitude-behavior correlation. Finally, the findings here illustrate that with increased environmental concerns among people, they come to include more such behaviors in their green portfolios.

A Study on Operation Strategy by Multi-variate Regression of Deagu Arboretum Visitor's Satisfaction (대구수목원 이용객 만족모델을 통한 운영 방안 연구)

  • Kang, Kee-Rae
    • Journal of Korean Society of Forest Science
    • /
    • v.101 no.1
    • /
    • pp.36-45
    • /
    • 2012
  • Education on the environment and plants offered by arboretum for today's people not only contribute to foster a better natural environment in urban region but also provide visitors with decent refreshment environment and beyond. In the study, the author undertook the observation on usage behavior and satisfaction model of arboretum visitors expect and investigated the facilities and programs to be offered by arboretum in order to propose the opinion regarding the service. For observation size of variables in a multiple regression analysis of variables is influencing satisfaction rankings walks the line of flow, the educational effect on the environment, cleanliness of the facility, visits pay, natural beauty, diversity of trees, accessibility and friendliness of staff, expansion of facilities in the arboretum and appeared as a complement. In case of visitor attribute, the residents living near the facility showed the highest visit frequency of more than 5 times, especially as part of taking a walk. This proves that the visit to arboretum is considered as part of everyday life, and thus a new program and walk path as well as movement route are needed to be developed for the visitors. In the question relating to the facilities and operation programs in Daegu Arboretum, particularly the requests by visitors, they responded that the establishment of cultural event, beautiful natural scenery, refreshment and convenience facilities is the most critical issue. In addition, the management on withered trees and bare lands is an urgent issue as well. In this sense, the Operation and Management Strategies based upon the visitor behaviors and model of satisfaction are needed to deal with the adoption of diverse events and festivals joined by local residents, ombudsman program, environmental program development for students and teachers within the region, negligent bare lands and withered tree replacement, and cafeteria facility improvement and supplement as well as the bench marking of other facilities than arboretums located in other regions. These items are thought to be sufficiently dealt with by Daegu Arboretum having no more external resources. It is recognized that the visitor satisfaction begins from a minor thing, and a small difference determines a great satisfaction, and thus the software approach rather than hardware one is in need.

Consideration on Shielding Effect Based on Apron Wearing During Low-dose I-131 Administration (저용량 I-131 투여시 Apron 착용여부에 따른 차폐효과에 대한 고찰)

  • Kim, Ilsu;Kim, Hosin;Ryu, Hyeonggi;Kang, Yeongjik;Park, Suyoung;Kim, Seungchan;Lee, Guiwon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.32-36
    • /
    • 2016
  • Purpose In nuclear medicine examination, $^{131}I$ is widely used in nuclear medicine examination such as diagnosis, treatment, and others of thyroid cancer and other diseases. $^{131}I$ conducts examination and treatment through emission of ${\gamma}$ ray and ${\beta}^-$ ray. Since $^{131}I$ (364 keV) contains more energy compared to $^{99m}Tc$ (140 keV) although it displays high integrated rate and enables quick discharge through kidney, the objective of this study lies in comparing the difference in exposure dose of $^{131}I$ before and after wearing apron when handling $^{131}I$ with focus on 3 elements of external exposure protection that are distance, time, and shield in order to reduce the exposure to technicians in comparison with $^{99m}Tc$ during the handling and administration process. When wearing apron (in general, Pb 0.5 mm), $^{99m}Tc$ presents shield of over 90% but shielding effect of $^{131}I$ is relatively low as it is of high energy and there may be even more exposure due to influence of scattered ray (secondary) and bremsstrahlung in case of high dose. However, there is no special report or guideline for low dose (74 MBq) high energy thus quantitative analysis on exposure dose of technicians will be conducted based on apron wearing during the handling of $^{131}I$. Materials and Methods With patients who visited Department of Nuclear Medicine of our hospital for low dose $^{131}I$ administration for thyroid cancer and diagnosis for 7 months from Jun 2014 to Dec 2014 as its subject, total 6 pieces of TLD was attached to interior and exterior of apron placed on thyroid, chest, and testicle from preparation to administration. Then, radiation exposure dose from $^{131}I$ examination to administration was measured. Total procedure time was set as within 5 min per person including 3 min of explanation, 1 min of distribution, and 1 min of administration. In regards to TLD location selection, chest at which exposure dose is generally measured and thyroid and testicle with high sensitivity were selected. For preparation, 74 MBq of $^{131}I$ shall be distributed with the use of $2m{\ell}$ syringe and then it shall be distributed after making it into dose of $2m{\ell}$ though dilution with normal saline. When distributing $^{131}I$ and administering it to the patient, $100m{\ell}$ of water shall be put into a cup, distributed $^{131}I$ shall be diluted, and then oral administration to patients shall be conducted with the distance of 1m from the patient. The process of withdrawing $2m{\ell}$ syringe and cup used for oral administration was conducted while wearing apron and TLD. Apron and TLD were stored at storage room without influence of radiation exposure and the exposure dose was measured with request to Seoul Radiology Services. Results With the result of monthly accumulated exposure dose of TLD worn inside and outside of apron placed on thyroid, chest, and testicle during low dose $^{131}I$ examination during the research period divided by number of people, statistics processing was conducted with Wilcoxon Signed Rank Test using SPSS Version. 12.0K. As a result, it was revealed that there was no significant difference since all of thyroid (p = 0.345), chest (p = 0.686), and testicle (p = 0.715) were presented to be p > 0.05. Also, when converting the change in total exposure dose during research period into percentage, it was revealed to be -23.5%, -8.3%, and 19.0% for thyroid, chest, and testicle respectively. Conclusion As a result of conducting Wilcoxon Signed Rank Test, it was revealed that there is no statistically significant difference (p > 0.05). Also, in case of calculating shielding rate with accumulate exposure dose during 7 months, it was revealed that there is irregular change in exposure dose for inside and outside of apron. Although the degree of change seems to be high when it is expressed in percentage, it cannot be considered a big change since the unit of accumulated exposure dose is in decimal points. Therefore, regardless of wearing apron during high energy low dose $^{131}I$ administration, placing certain distance and terminating the administration as soon as possible would be of great assistance in reducing the exposure dose. Although this study restricted $^{131}I$ administration time to be within 5 min per person and distance for oral administration to be 1m, there was a shortcoming to acquire accurate result as there was insufficient number of N for statistics and it could be processed only through non-parametric method. Also, exposure dose per person during lose dose $^{131}I$ administration was measured with accumulated exposure dose using TLD rather than through direct-reading exposure dose thus more accurate result could be acquired when measurement is conducted using electronic dosimeter and pocket dosimeter.

  • PDF