• Title/Summary/Keyword: S-N curve

Search Result 720, Processing Time 0.03 seconds

APPROXIMATE ESTIMATION OF THE SURVIVAL RAT IN FISH POPULATION UTILIZING THE LENGTH COMPOSITION (체장조성으로서 생잔율를 추정하는 방법 - I)

  • SHIN Sang Taek
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.9 no.2
    • /
    • pp.143-150
    • /
    • 1976
  • A trial has been made to find out a new method of calculating the survival rate of a fish Population utilizing the length composition data and the characteristics of the frequency curve of the length which usually is normal distribution curve. In this paper, a stochastic method is introduced and applied to calculate the survival rate of yellow croaker caught by Korean trawlers in the Yellow Sea and the East China Sea in 1971. The results are as follows : Mean of survival rate 0.46089 Variance 0.03073 Standard deviation 0.17529 95 percent confidence interval 0.36040-0.56138.

  • PDF

Thermodynamic Analysis of the Low- to Physiological-Temperature Nondenaturational Conformational Change of Bovine Carbonic Anhydrase

  • Hollowell, Heather N.;Younvanich, Saronya S.;McNevin, Stacey L.;Britt, B. Mark
    • BMB Reports
    • /
    • v.40 no.2
    • /
    • pp.205-211
    • /
    • 2007
  • The stability curve - a plot of the Gibbs free energy of unfolding versus temperature - is calculated for bovine erythrocyte carbonic anhydrase in 150 mM sodium phosphate (pH = 7.0) from a combination of reversible differential scanning calorimetry measurements and isothermal guanidine hydrochloride titrations. The enzyme possesses two stable folded conformers with the conformational transition occurring at ~30$^{\circ}C$. The methodology yields a stability curve for the complete unfolding of the enzyme below this temperature but only the partial unfolding, to the molten globule state, above it. The transition state thermodynamics for the low- to physiological-temperature conformational change are calculated from slow-scan-rate differential scanning calorimetry measurements where it is found that the free energy barrier for the conversion is 90 kJ/mole and the transition state possesses a substantial unfolding quality. The data therefore suggest that the x-ray structure may differ considerably from the physiological structure and that the two conformers are not readily interconverted.

Variable amplitude fatigue test of M30 high-strength bolt in bolt-sphere joint grid structures

  • Qiu, Bin;Lei, Honggang;Yang, Xu;Zhou, Zichun;Wang, Guoqing
    • Steel and Composite Structures
    • /
    • v.33 no.3
    • /
    • pp.433-444
    • /
    • 2019
  • Fatigue failure of a grid structure using bolt-sphere joints is liable to occur in a high-strength bolt due to the alternating and reciprocal actions of a suspension crane. In this study, variable amplitude fatigue tests were carried out on 20 40 Cr steel alloy M30 high-strength bolts using an MTS fatigue testing machine, and four cyclic stress amplitude loading patterns, Low-High, High-Low, Low-High-Low, and High-Low-High, were tested. The scanning electron microscope images of bolt fatigue failure due to variable amplitude stress were obtained, and the fractographic analysis of fatigue fractures was performed to investigate the fatigue failure mechanisms. Based on the available data from the constant amplitude fatigue tests, the variable amplitude fatigue life of an M30 high-strength bolt in a bolt-sphere joint was estimated using both Miner's rule and the Corten-Dolan model. Since both cumulative damage models gave similar predictions, Miner's rule is suggested for estimating the variable-amplitude fatigue life of M30 high-strength bolts in a grid structure with bolt-sphere joints; the S-N fatigue curve of the M30 high-strength bolts under variable amplitude loading was derived using equivalent stress amplitude as a design parameter.

Fatigue Safe Life Analysis of Helicopter Rotor Bearingless Hub System Composite Components (헬리콥터 로터 무베어링 허브 시스템 복합재 구성품 피로 안전수명 해석)

  • Kim, Taejoo;Kee, Youngjoong;Kim, Deog-Kwan
    • Aerospace Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.10-19
    • /
    • 2014
  • We designed bearingless rotor hub system which replace mechanical hinge/bearing with composite beam component and conducted fatigue analysis for flexbeam and torque tube. Extension/bending/torsional stiffness was calculated from 2D section analysis using VABS and 2D section structure analysis was applied for strain calculation. S-N curve of each composite material was generated using Wohler equation and fatigue analysis was conducted on weakness section which was decided from static structure analysis. CAMRAD II was used for load analysis and load analysis result was applied HELIX/FELIX standard load spectrum to generate bearingless rotor system load spectrum which was used fatigue safe life analysis.

A Study on Easing Contraction made by different angles About angles on the sleeve cap curve line (재단각도 변화에 따른 오그림에 관한 연구 -소매산둘레선상의 각도를 중심으로-)

  • 이명희;최석철
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.22 no.1
    • /
    • pp.41-48
    • /
    • 1998
  • An investigation made of the easing contraction ratio according to sewing conditions (eased seam angle; 0$^{\circ}$ 20$^{\circ}$ 30$^{\circ}$ 45$^{\circ}$ 60$^{\circ}$ 70$^{\circ}$ 90$^{\circ}$, stitch density; 38 stitches/3 cm(N1.0), 26 stitches/ 3 cm(N1.5), 19 stitches/3 cm(N2.0), 14 stitches/3 cm(N2.5), 12 stitches/3 cm(N3.0), thread; sp 60' s/2) by lockstitch industrial sewing machine with shirring foot. The results abstained were as follows: 1. The lower the stitch density , the higher the easing contraction ratio. 2. The easing contraction ratio at 0$^{\circ}$ and 90$^{\circ}$ were lower than bias angles (20$^{\circ}$, 30$^{\circ}$, 45$^{\circ}$, 60$^{\circ}$, 70$^{\circ}$). 3. As the results of visual test, the maximum easing conditions were Fl -0$^{\circ}$.20$^{\circ}$.30$^{\circ}$.45$^{\circ}$-12 stitches/3 cm(N3.0), 60$^{\circ}$. 70$^{\circ}$. 90$^{\circ}$-14 stitches/3 cm(N2.5), F2 -0$^{\circ}$. 20$^{\circ}$.30$^{\circ}$.60$^{\circ}$.70$^{\circ}$.90$^{\circ}$-19 stitches/ 3 cm(N2.0), 45$^{\circ}$ -14 stitches/3 cm(N2.5), and F3 -0$^{\circ}$.20$^{\circ}$.30$^{\circ}$.45$^{\circ}$.60$^{\circ}$.70$^{\circ}$.90$^{\circ}$-19 stitches/3 cm (N2.0). 4. Approximately easing contraction ratio was obtained as 2.0% (N1.0)~ 10.2% (N3.0) in F1, 6.7% (N1.0)~ 15.7% (N2.0) in F2, and 5.2% (N1.0)~ 12.1% (N2.0) in F3, according to different angles on the sleeve cap curve line. 5. As a resets of SPSS PC) statistics analysis, it confirmed the relations which were observed between easing contration ratio and stitch density, and easing contraction ratio was correlated with bending properties.

  • PDF

Evaluation of Modified Design Fire Curves for Liquid Pool Fires Using the FDS and CFAST (FDS와 CFAST를 이용한 액체 풀화재의 수정된 디자인 화재곡선 평가 연구)

  • Baek, Bitna;Oh, Chang Bo;Lee, Chi Young
    • Fire Science and Engineering
    • /
    • v.32 no.2
    • /
    • pp.7-16
    • /
    • 2018
  • In this study, the previous design fire curve for fire simulation was modified and re-suggested. Numerical simulations with the FDS and CFAST were performed for the n-heptane and n-octane pool fires in the ISO 9705 compartment to evaluate the prediction performances of the previous 1-stage and modified 2-stage design fire curves. The numerical results were compared with the experimental temperature and concentrations of $O_2$ and $CO_2$. The FDS and CFAST simulations with the 2-stage design fire curve showed better prediction performance for the variation of temperature and major species concentration than the simulations with 1-stage design fire curve. Especially, the simulations with the 2-stage design fire curve agreed with the experimental temperature more reasonably than the results with the 1-stage design fire curve. The FDS and CFAST simulations showed good prediction performance for the temperature in the upper layer of compartment and the results with the FDS and CFAST were similar to each other. However, the FDS and CFAST showed poor and different prediction performance for the temperature in the lower layer of compartment.

Assessment of Pollution Levels in the Jangsungcheon Watershed Using Load Duration Curves and Analysis of the Causes

  • Cho, Sohyun;Bak, Jonghun;Lee, Yeong Jae;Kim, Kyunghyun;Jung, Kang Young
    • Journal of Environmental Science International
    • /
    • v.28 no.10
    • /
    • pp.873-885
    • /
    • 2019
  • In this study, a load duration curve was applied to the Jangseongcheon, one of the tributaries of the Yeongsan River, to assess whether the target water quality was achieved. In addition, pollution of the water body was investigated to develop and suggest the optimal management time with respect to polluted flow sections and monthly conditions. The average flow rates of sections JS1 and JS2 were $0.25m^3/s$ and $1.08m^3/s$, respectively. The BOD and T-P for water-quality standards at JS1 were rated at II, whereas the COD and TOC were rated at III, thus indicating a fair level of water quality. By contrast, the BOD at JS2 was rated at III, the T-P at IV, and the TOC at V, indicating poor water quality in this section. The load duration curve was plotted using the actual flow data measured in eight-day intervals for eight years from 2011 to 2018 at locations JS1 and JS2 in the Jangsungcheon Basin. In an assessment using the load duration curve on whether the target water quality was met at location JS1, all of the water quality parameters (BOD, COD, TOC, T-N, T-P, and SS) satisfied the target water quality. By contrast, at location JS2, parameters COD, TOC, T-N, and T-P exceeded target values by more than 50%, indicating the target water quality was not met. The discharge loads of locations JS1 and JS2 were analyzed to identify the reasons the target water quality was exceeded. Results revealed that the land system contributed considerably. Furthermore, the discharge load of JS2 accounted for more than 80% of the load on the entire basin, excluding that of JS1. Therefore, the best method for restraining the inflow of pollutants into the stream near location JS2 must be applied to manage the water quality of the Jangsungcheon.

Comparison of Mathematical Models Applied to F1 Dairy Sheep Lactations in Organic Farm and Environmental Factors Affecting Lactation Curve Parameter

  • Angeles-Hernandez, J.C.;Albarran-Portillo, B.;Gomez Gonzalez, A.V.;Pescador Salas, N.;Gonzalez-Ronquillo, M.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.26 no.8
    • /
    • pp.1119-1126
    • /
    • 2013
  • The objective of this study was to compare the goodness of fit of four lactation curve models: Wood's Gamma model (WD), Wilmink (WL), and Pollott's multiplicative two (POL2) and three parameters (POL3) and to determine the environmental factors affecting the complete lactation curve of F1 dairy sheep under organic management. A total of 5,382 weekly milk yields records from 150 ewes, under organic management were used. Residual mean square (RMS), determination coefficients ($R^2$), and correlation (r) analysis were used as an indicator of goodness of fit for each model. WL model best fitted the lactation curves as indicated by the lower RMS values (0.019), followed by WD (0.023), POL2 (0.025) and POL3 (0.029). The four models provided total milk yield (TMY) estimations that were highly correlated (0.93 to 0.97) with observed TMY (89.9 kg). The four models under estimated peak yield (PY), whereas POL2 and POL3 gave nearer peak time lactation estimations. Ewes lambing in autumn had higher TMY and showed a typical curve shape. Higher TMY were recorded in second and third lambing. Season of lambing, number of lambing and type of lambing had a great influenced over TMY shaping the complete lactation curve of F1 dairy sheep. In general terms WL model showed the best fit to the F1 dairy sheep lactation curve under organic management.

A Study on the Flexural Fatigue Behavior of R/C Beams Repaired with Concrete-Polymer Composites (유기 및 유기재료로 보수된 R/C 보의 휨 피로거동에 관한 연구)

  • 심종성;황의승;배인환;이은호
    • Magazine of the Korea Concrete Institute
    • /
    • v.7 no.6
    • /
    • pp.233-241
    • /
    • 1995
  • In this thesis, the fatigue tests were performed on a series of R /C beams repaired with co& crete-lmlyrner composites to investigate the fatigue bahavior. The three point loading system is used in the fatigue tests. In these tests, relations between the repeated loading cycles and mid-span deflections, number of repeated loading cycles when repaired beams were fractured, the bonding performance of repair materials were observed. On this basis, the mid-span deflections, the crack growth and failure mode of repaired R /C beams were studied. A S-N curve was drawn to present the fatigue strength of repaired beams. From the test results, it was shown that behavior of R /C beams repaired with polymer-cement series were very sirnillar to control beam about bonding performance, mid-span deflections and fatigue strength according to S-N curve drawn by the regression anlysis on the fatigue test results.

The Effects of Solvent and Nonsolvent on Asymmetric Membrane Structure of 6FDA-p-TeMPD Polyimide (6FDA-p-TeMPD 폴리이미드 비대칭막 제조에서 용매와 비용매가 막구조에 미치는 영향)

  • 박노춘;김건중;남세종
    • Membrane Journal
    • /
    • v.8 no.3
    • /
    • pp.157-169
    • /
    • 1998
  • The effects of solvents (DMAc, NMP, 1,4-dioxane) and nonsolvents ($H_2O$, Methanol, n-hexane) on the morphology of 6FDA-p-TeMPD polyimide membrane, prepared by the wet phase inversion method, were studied. In the polymer/solvent/nonsolvent ternary system, the binodal curve, the coagulation value and the relative light transmission were measured, and the solubility parameter difference was calculated. The onset state and rate of liquid-liquid alemixing were predicted and the morphology of membrane was analyzed. It is found that the finger-like pores are formed within discontinuous polymer nodules when the binoclal curve is close to the polymer-solvent (P-S) axis, the coagulation value is small, the reduction of light transmission is easy to occur and the order of solubility parameter difference ($\Delta \delta_{i-j}$) is $\Delta \delta_{S-NS} > \Delta \delta_{P-NS} > \Delta \delta_{P-S}$. The dense skin with small nodules and the sponge type sublayer with macrovoid are formed in the case that the binodal curve is distant from the P-S axis, the onset time of liquid-liquid demixing is long and the order of $\Delta \delta_{i-j}$ is $\Delta \delta_{P-NS} >(\Delta \delta_{S-NS} < > \Delta \delta_{P-S})$. The thick layer of fine nodule coagulation and loosely grown sublayer of nodules appear when the binodal curve is distant from the P-S axis, the onset time of liquid-liquid demixing is very long and the order of $\Delta \delta_{i-j}$$\Delta \delta_{S-NS} > (\Delta \delta_{P-NS}$\lessgtr$ > (\Delta \delta_{P-NS} < >)\Delta \delta_{P-S}$ ).

  • PDF