• Title/Summary/Keyword: S-Duct

Search Result 598, Processing Time 0.026 seconds

Effects of Product Value of Outlet Stores on Customer Satisfaction and Loyalty (아울렛의 제품 가치가 고객 만족도와 충성도에 미치는 영향)

  • Choi, Soon-Hwa;Jung, Yeon-Sung;Kim, Moon-Seop
    • Journal of Distribution Science
    • /
    • v.14 no.4
    • /
    • pp.93-101
    • /
    • 2016
  • Purpose - As more consumers pursue high quality products at reasonable prices, Korean retail companies are increasing investment in expanding their outlet stores. Despite the growing importance of the outlet business, there has been very little empirical research on consumers' outlet shopping behaviors. This study aimed to investigate the relationships between consumers' perceived product value (performance quality, value for money, and social value) of outlet stores and overall shopping satisfaction and the effect of shopping satisfaction on outlet store loyalty. Research design, data and methodology - The authors developed a structural model in which performance quality, value for money, and social value of products are proposed to affect overall outlet shopping satisfaction, thus increasing customer loyalty. To analyze the research model, data were collected from 88 shoppers at suburban outlets. SPSS 21.0 and AMOS 21.0 were utilized to test the hypotheses. The unidimensionality of each construct was supported from the results of the reliability test with Cronbach's α and confirmatory factor analyses. Correlation analysis was performed and the results warranted the nomological validity of the measures. The fit statistics of the overall model analysis demonstrated an acceptable fit(X2(161)=171.651, p=.000; X2/df=1.546; GFI=.821, NFI=.879, TLI=.942, CFI=.953, RMR=.035, RMSEA=.079). Results - The findings are as follows. First, consumers' perceived value of product performance quality had a significant positive effect on overall outlet shopping satisfaction. Consumers, who evaluate performance quality of the product more positively, tend to express stronger satisfaction and happiness about outlet shopping experience. Second, consumers' perceived social value of outlet products influenced their overall satisfaction significantly. Consumers who believe that products of outlet stores enhance self-concepts are more likely to satisfy with outlet shopping experience. However, consumers' perception of outlet products on value for money was not found to significantly influence overall shopping satisfaction. Finally, overall shopping satisfaction had a significant and positive influence on loyalty. Conclusions - While outlet retailers have traditionally focused on promoting competitively priced merchandise, the results of this study suggest that customers' overall satisfaction with outlet shopping is influenced more by the non-price-related product values. In the context of an outlet shopping environment, performance quality and social value of the products were found to be more critical predictors of customer overall satisfaction. Therefore, it would not be efficient for outlet retailers to highlight economic value of their merchandise. Instead, they need to investigate the performance quality of the products regularly and try to deliver quality guaranteed goods to enhance customer satisfaction. Also, outlet retailers should differentiate their businesses by carrying more unique and prestigious brands and emphasize higher social value and symbolic meanings of their products. As competition among outlet retailers are getting fierce, retail companies need to focus on strengthening customer loyalty with a long-term perspective. With a deeper understanding of the relationship between consumers' perceived product values and shopping satisfaction, outlet retailers will be able to develop customer loyalty strategies effectively and to achieve competitive advantage.

Percutaneous Biliary Metallic Stent Insertion in Patients with Malignant Duodenobiliary Obstruction: Outcomes and Factors Influencing Biliary Stent Patency

  • Ji Hye Kwon;Dong Il Gwon;Jong Woo Kim;Hee Ho Chu;Jin Hyoung Kim;Gi-Young Ko;Hyun-Ki Yoon;Kyu-Bo Sung
    • Korean Journal of Radiology
    • /
    • v.21 no.6
    • /
    • pp.695-706
    • /
    • 2020
  • Objective: To investigate the technical and clinical efficacy of the percutaneous insertion of a biliary metallic stent, and to identify the factors associated with biliary stent dysfunction in patients with malignant duodenobiliary obstruction. Materials and Methods: The medical records of 70 patients (39 men and 31 women; mean age, 63 years; range, 38-90 years) who were treated for malignant duodenobiliary obstruction at our institution between April 2007 and December 2018, were retrospectively reviewed. Variables found significant by univariate log-rank analysis (p < 0.2) were considered as suitable candidates for a multiple Cox's proportional hazard model. Results: The biliary stents were successfully placed in all 70 study patients. Biliary stent insertion with subsequent duodenal stent insertion was performed in 33 patients and duodenal stent insertion with subsequent biliary stent insertion was performed in the other 37 study subjects. The median patient survival and stent patency time were 107 days (95% confidence interval [CI], 78-135 days) and 270 days (95% CI, 95-444 days), respectively. Biliary stent dysfunction was observed in 24 (34.3%) cases. Multiple Cox's proportional hazard analysis revealed that the location of the distal biliary stent was the only independent factor affecting biliary stent patency (hazard ratio, 3.771; 95% CI, 1.157-12.283). The median biliary stent patency was significantly longer in patients in whom the distal end of the biliary stent was beyond the distal end of the duodenal stent (median, 327 days; 95% CI, 249-450 days), rather than within the duodenal stent (median, 170 days; 95% CI, 115-225 days). Conclusion: The percutaneous insertion of the biliary metallic stent appears to be a technically feasible, safe, and effective method of treating malignant duodenobiliary obstruction. In addition, a biliary stent system with a distal end located beyond the distal end of the duodenal stent will contribute towards longer stent patency in these patients.

The study of CFD Modelling and numerical analysis for MSW in MBT system (생활폐기물 전처리시스템(MBT)의 동역학적 수치해석 및 모델링에 대한 연구)

  • Lee, Keon joo;Cho, Min tae;Na, Kyung Deok
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.18 no.3
    • /
    • pp.77-86
    • /
    • 2010
  • In this study, the model of the indirect wind suction waste sorting machine for characteristics of the screening of waste was studied using computational fluid dynamics and the drag coefficient for the model and the suction wind speed were obtained. The wind separator are developing by installing a cyclone air outlet to the suction blower impeller waste is selective in a way that does not pass the features and characteristics of the inlet pipe of the pressure loss and separation efficiency can have a significant impact on. Using Wind separator for selection of waste in the waste prior research on the aerodynamic properties are essential. For plastic cases, it is reasonable to take the drag coefficient between 0.8 and 1.0, and for cans, compression depending on whether the cans, the drag coefficient is in the range from 0.2 to 0.7. The separation efficiency of waste as change suction speed was the highest efficiency when the suction speed was 25~26 m/s. Shape of the inlet, depending on how the transfer pipe of the duct pressure loss occurs because the inlet velocity changes through the appropriate design standards to allow for continued research is needed.

Effects of Different Ventilation Systems on Rearing Growing-finisher and Indoor Environment in a High Rise Hog Building (고상식 돈사내에서 환기시스템별 환경조사 및 육성비육돈 사육 효과)

  • Yoo, Y.H.;Jeong, J.W.;Park, K.H.;Song, J.I.;Ko, Y.G.;Kim, S.W.;Lee, I.B.
    • Journal of Animal Environmental Science
    • /
    • v.16 no.3
    • /
    • pp.193-204
    • /
    • 2010
  • The goal of this study was to develop a high-rise hog building(HRHB) for growing-fattening stages. HRHB was two story building and was suitable for specific environment in Korea. Manure was treated in a first floor and pigs were raised on the slatted second floor. Three ventilation systems - 1) duct inlet to wall exhaust system(V1), 2) eave inlet to wall exhaust system(V2), and 3) ceiling inlet to wall exhaust system(V3) - were used. This experiment was conducted during winter and from summer to fall. Air temperature, air speed, ammonia, hydrogen sulfide in HRHB, and swine growth rate were measured. During winter, air temperature in V1 system tended to be slightly high without any effect of outside air temperature. Maximum temperature from summer to fall was between 33.4 and $33.8^{\circ}C$ and there was no significant difference among systems. Continuously measured daily temperature was lower in V2 system than other systems and the fluctuation of air temperature was high. Air speed in V1 and V2 systems were similar (0.02~0.21 m/s), and was 0.04~0.15 m/s in V3 during winter. From summer to fall, air speed in V1, V2, and V3 systems were 0.10~0.41 m/s, 0.10~0.83 m/s, and 0.11~0.26 m/s, respectively. V2 system showed bigger fluctuation of air speed than other systems. During winter, the highest concentrations of ammonia in V1, V2, and V3 systems were 7.0, 3.5, and 8.7 ppm, respectively. Hydrogen sulfide was not detected. The highest concentrations of ammonia from summer to winter in V1, V2, and V3 systems were 6.1, 2.8, and 5.6 ppm, respectively. Swine growth showed no statistical significance among systems. However, daily weight gain was approximately 4% higher in V1 and V3 than in V2. Feed intake/daily weight gain was approximately 4% higher in V1 than other systems. From summer to fall, daily weight gain in V1 and V3 tended to approximately 3% higher than other systems, and feed intake/daily weight gain was approximately 2% higher in V1 than other systems. Hence, V2 system for the ventilation system of HRHB should not be utilized.

Expression of Neuronal Nitric Oxide Synthase (nNOS) in Developing Rat Kidney (분화중인 흰쥐 콩팥의 요세관에서 nNOS의 발현)

  • Song, Ji-Hyun;Ryu, Si-Yun;Kim, Jin;Jung, Ju-Young
    • Applied Microscopy
    • /
    • v.38 no.2
    • /
    • pp.141-148
    • /
    • 2008
  • Nitric oxide (NO) is an important regulator of renal blood flow, glomerular hemodynamics, and tubule transport processes in the kidney. There is also evidence that NO is involved in cell cycle regulation and mitotic division. During development the nNOS expression pattern differs from that observed in adult animals. However, little is known about temporal and spatial patterns of nNOS expression in the developing kidney. The purpose of this study was to establish the time of expression and the distribution of nNOS in the developing rat kidney. Kidneys from 14-, 16-, 17-, 18-, and 20-day-old fetuses, 1-, 4-, 7-, 14-, and 21-day-old pups, and adult animals were preserved and processed for immunohistochemistry. In the adult kidney, nNOS was detected in the parietal epithelium of Bowman s capsule, macula densa, descending thin limb and inner medullary collecting duct. nNOS immunoreactivity appeared first in the distal tubule anlage at 15 days of gestation, and in all epithelial cells of developing thick ascending limbs (TAL) as well as macula densa of 17- and 18-day-old fetuses. From 20 days of gestation to 14 days after birth, nNOS was expressed in the newly formed cortical TAL, which are located in the medullary ray, whereas in mature TAL of juxtamedullary nephrons, nNOS immunolabeling gradually decreased in intensity and became restricted to the macula densa. In inner medullary collecting ducts, nNOS immunoreactivity appeared first at 7 days after birth in the papillary tip and gradually ascended to the border between outer and inner medulla. In the descending thin limb and parietal epithelium of Bowman's capsule, weak nNOS immunoreactivity was observed at 14 days after birth and labeling gradually increased to adult levels at 21 days after birth. These results suggest that differential expression of nNOS in the developing kidney is an important physiological regulator of renal function during kidney maturation.

Effective Fan Noise Control Using Active Noise Control (능동소음제어를 이용한 효과적인 팬소음의 제어)

  • Eom Seung-Sin;Shin Inwhan;Lee Soogab
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • autumn
    • /
    • pp.433-438
    • /
    • 1999
  • This paper describes Active Noise Cancellation/Control(ANC) method that removes the information of the unnecessary noise and doesn't remove the informations of the necessary noise(warning sound, operating sound etc.) for the induced noise of the mechanical system. In this paper, the noise source Is axial fan, and the Feedback Active Noise control method that can effectively control BPF generated from the axial fan is used, and the Filtered-X LMS algorithm for adaptive algorithms is used. The experiments are executed for two case(propagating noise in the duct, emission noise for exterior free field). The part to be removed is BPF noise, and the band-pass filter not to effect to the other frequencies is used. Also, to investigate the effect of the noise reduction for human, we are compared with the results that are controlled for using Loudness before and after. As a results, we are certified that the BPF is decreased only and frequencies outside of BPF are not affected, and we acquire the reduction effects of 6.7 dB Loudness Level, then the frequency to be removed is controlled. Therefore, we can be certified that sound pressure as well as loudness can be effectively decreased for human sound quality

  • PDF

A Study on Regulation Improvement of Local Ventilation System (국소배기장치의 규제개선에 관한 연구)

  • kim, Nam Suk;Kim, Young Suk;Woo, In Sung
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.3
    • /
    • pp.74-83
    • /
    • 2018
  • Anyone who wants to install local ventilation system must obtain a permission from the Ministry of Employment and Labor even if he has permission from the Ministry of Environment. This is because not only the Atmospheric Environmental Protection Act, but also the manufacturing industry's hazardous risk prevention plan under Article 48 Clause 2 of the Industrial Safety and Health Act is to be submitted by 15 days before the construction. Under the current Environmental Protection Act, the Ministry of Environment regulates only the emission of pollutants from local exhaust ventilation systems into the atmosphere and the contents of workers' safety and health within industrial sites are managed by the Ministry of Employment and Labor. Even with the approval of the Ministry of Environment, the number of unsuccessful cases by the Ministry of Employment and Labor has increased, causing a growing discontent among the sites due to production delays and additional costs of improvement. In addition, local exhaust systems that are at greater risk of fire explosion have increased the risk of severe industrial accidents due to fire explosion. This is due to insufficient design of air volume, control speed, return speed, duct size, and risk of fire explosion. This is because the criteria and procedures for approval of local exhaust ventilation systems are similar, but the Industrial Safety and Health Act adds additional screening items for safety and safety of workers and fire and explosion. In this study, the Environment Ministry and the Employment and Labor Ministry seek to find a reasonable way to operate the system by comparing local exhaust ventilation system installation approval standards.

Establishment of an Allo-Transplantable Hamster Cholangiocarcinoma Cell Line and Its Application for In Vivo Screening of Anti-cancer Drugs

  • Puthdee, Nattapong;Vaeteewoottacharn, Kulthida;Seubwai, Wunchana;Wonkchalee, Orasa;Keawkong, Worasak;Juasook, Amornrat;Pinloar, Somchai;Pairojkul, Chawalit;Wongkham, Chaisiri;Okada, Seiji;Boonmars, Thidarut;Wongkham, Sopit
    • Parasites, Hosts and Diseases
    • /
    • v.51 no.6
    • /
    • pp.711-717
    • /
    • 2013
  • Opisthorchis viverrini (O. viverrini) is a well-known causative agent of cholangiocarcinoma (CCA) in humans. CCA is very resistant to chemotherapy and is frequently fatal. To understand the pathogenesis of CCA in humans, a rodent model was developed. However, the development of CCA in rodents is time-consuming and the xenograft-transplantation model of human CCA in immunodeficient mice is costly. Therefore, the establishment of an in vivo screening model for O. viverrini-associated CCA treatment was of interest. We developed a hamster CCA cell line, Ham-1, derived from the CCA tissue of O. viverrini-infected and N-nitrosodimethylamine-treated Syrian golden hamsters. Ham-1 has been maintained in Dulbecco's Modified Essential Medium supplemented with 10% fetal bovine serum for more than 30 subcultures. These cells are mostly diploid (2n=44) with some being polyploid. Tumorigenic properties of Ham-1 were demonstrated by allograft transplantation in hamsters. The transplanted tissues were highly proliferative and exhibited a glandular-like structure retaining a bile duct marker, cytokeratin 19. The usefulness of this for in vivo model was demonstrated by berberine treatment, a traditional medicine that is active against various cancers. Growth inhibitory effects of berberine, mainly by an induction of G1 cell cycle arrest, were observed in vitro and in vivo. In summary, we developed the allo-transplantable hamster CCA cell line, which can be used for chemotherapeutic drug testing in vitro and in vivo.

$^{99m}Tc-DISIDA$ Hepatobiliary Scintigraphic Study in Symptomatic Patients after Various Biliary Surgeries: Regional Emphasis of Recurrent Pyogenic Cholangitis and Intrahepatic Duct Stones (담도계 수술후 증상이 재발한 환자에서의 $^{99m}Tc-DISIDA$ Hepatobiliary Scintigraphy: 재발 농양성 간담도염과 간내 담석 발생빈도의 지역적인 특성을 고려한 연구)

  • Yum, H.Y.;Park, Y.H.;Suh, J.K.;Lee, S.D.;Choi, K.H.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.20 no.2
    • /
    • pp.19-38
    • /
    • 1986
  • 54 patients who had symptoms after biliary operation were studied by $^{99m}Tc-DISIDA$ hepatobiliary scintigraphy for evaluation of clinical utility, with regional emphasis of recurrent pyogenic cholangitis (RPC) and intrahepatic stones. As expected, the most common disease was recurrent pyogenic cholangitis regardless of surgical anastomosis, 58% and next frequent disease was clonorhis sinensis infestation, 26%, stenosis of ampula vater 8%, and chronic hepatitis 4% (20% of patients had hepatitis but they showed clinically and scintigraphically dominallt combined disease feature). 87% of recurrent pyogenic cholangitis was associated with stones in intra or/and extrahepatic ducts and only 11.4% of RPC was found to be associated with Cs-infestation. The scintigraphic diagnosis of RPC was 81.6% and 78.6% of stones was detected by indirect visualization of scintigraphy findings and 71.7% of Cs-infestation was detected by scintigraphy. The characteristic bile flow pattern were described.

  • PDF

Air Fluid Analysis between Porous PE-Plate and Glass in Air-Floating FPD Conveyor System (공기부상 FPD 이송장치에서 다공질판과 글래스 사이의 공기유동 해석)

  • Lho, Tae-Jung;Shon, Tae-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.4
    • /
    • pp.878-885
    • /
    • 2008
  • The FPDs(Flat Panel Displays) such as LCD(Liquid Crystal Display) and PDP(Plasma Display Panel) and OLED(Organic Light Emitting Diode), recently, have been substituted for CRT(Cathode Ray Tube) displays because they have a convex surface, small volume, light weight and lower electric power consumption. The productivity of FPDs is greatly dependent on the area of thin glass panel with 0.6 - 0.8mm thickness because FPDs are manufactured by cutting a large-scaled thin glass panel with patterns to the required product dimensions. So FPD's industries are trying to increase the area of thin glass panel. For example, the thin glass panel size of the 8th generation is 2,200mm in width, 2,600mm in length and 0.7mm in thickness. The air flows both in the thin glass panel and in the porous PE-plate surface were modeled and analyzed, from which a working condition was estimated. The thin glass panel on the porous PE-plate surface with self-lubricating characteristics was investigated and compared with that on the square duct floating bar surface with many holes of 1mm diameter when the thin glass panel contacts the floating bar surface due to malfunction of electric power supply.