• Title/Summary/Keyword: S-100 Standard

Search Result 1,003, Processing Time 0.032 seconds

Correlation between Board Mortar and Defect Occurrence Rate in Apartment Bathroom Wall Tile (공동주택 욕실 벽타일 뒤채움과 하자발생량의 상관관계분석)

  • Hong, Ki;Nam, Dong-Hee;Koo, Kyo-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.55-56
    • /
    • 2023
  • The number of defect disputes occurring in apartment houses is increasing year by year, and among them, disputes caused by defects in tiles account for 28.2% of the total, which is an important defect in tiles. A representative tile defect in the defect dispute is the lack of tile backfill. Another dispute occurred that the standards for each organization are different as the 100% standard of the Ministry of Land, Infrastructure and Transport's building construction standard and 80% standard of the Architectural Institute of Korea's Building Technology Guidelines. In this study, it was analyzed the relationship between the amount of tile backfill and the amount of tile defects based on 100 defect litigation court appraisal documents. It was observed that the amount of defect in tile works tended to decrease as the amount of tile backfill increased. By presenting an appropriate amount of mortar to fill behind tiles in a defect dispute, the effect of reducing the defect dispute can be expected.

  • PDF

Examination of GC-TD sensitivity for reduced sulfur compounds in relation to temporal stability and reproducibility (환원 황화합물의 열탈착 분석기법에 대한 감도의 경시변화 및 재현성에 대한 연구)

  • Hong, One-Feel;Kim, Ki-Hyun
    • Analytical Science and Technology
    • /
    • v.23 no.1
    • /
    • pp.24-35
    • /
    • 2010
  • To learn more about the calibration properties of reduced sulfur compounds (RSCs) by the combination of gas chromatography(GC)-pulsed flame photometric detector (PFPD) and thermal desorption method, a series of calibration experiments were conducted on the basis of both internal and external calibration approaches. For these experiments, gaseous standards of 4 RSCs ($H_2S$, $CH_3SH$, DMS, and DMDS) were prepared at two different concentration levels of both low (10, 20, 50,and 100 ppb) and high ranges (100, 200, 500, and 1000 ppb) along with $CS_2$ as an internal standard. First, the external calibration results were compared between fixed standard volume (FSV) and fixed standard concentration (FSC) method. Secondly, FSV-based calibration results were compared between external and internal calibration results. As FSV method suffers from sensitivity variations less significantly than FSC, the former is recommended to maintain the consistency in GC-TD sensitivity for RSC analysis. In addition, when the calibration data were examined in terms of RSE between external and internal calibration data, the results were not consistent enough to show improvements in internal method. Hence, diverse efforts are desirable to optimize the reproducibility in terms of GC-TD sensitivity for RSC analysis.

Telemetry Standard 106-17 LDPC Encoder Design Using HLS (HLS를 이용한 텔레메트리 표준 106-17 LDPC 부호기 설계)

  • Gu, Young Mo;Lee, Woonmoon;Kim, Bokki
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.48 no.10
    • /
    • pp.831-835
    • /
    • 2020
  • By automatically generating HDL codes from C/C++ source codes, HLS makes it possible to shorten FPGA system developing period through easy timing control and structure change. We designed LDPC encoder for telemetry standard 106-17 with Xilinx Vivado HLS and showed hardware structure can be easily adapted for different purposes through minor C code modification. Synthesis results targeting Spartan-7 xc7s100 device are presented for throughput and hardware complexity comparison.

Design of High Speed LDPC Encoder Based on DVB-S2 Standard (DVB-S2 기반 고속 LDPC 부호기 설계)

  • Park, Gun Yeol;Lee, Seong Ro;Jeon, Sung Min;Jung, Ji-Won
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38C no.2
    • /
    • pp.196-201
    • /
    • 2013
  • In this paper, we proposed high speed LDPC encoder architecture for DVB-S2 standard. In conventional algorithm, the processes of parity calculations are serial fashion. Therefore conventional algorithm need clocks of number of parity. The proposed LDPC encoding architecture is based on a parallel 360 bits-wise operations. The key issues for realizing high speed are using the two kinds of index addresses and make use of memories efficiently. We implemented a half rate LDPC encoder on an FPGA, and confirmed its maximum throughput is up to 10 Gbps on 100MHz clock.

The Pre-Clinical Experiments of the Compounding Antipyretic Analgesics (배합해열진통제(配合解熱鎭痛劑)의 전임상시험(前臨床試驗)에 관(關)한 연구(硏究))

  • Kim, Jae-Wan
    • Journal of Pharmaceutical Investigation
    • /
    • v.10 no.1
    • /
    • pp.4-12
    • /
    • 1980
  • The studies of the compounding analgestic antipyretics were examined by the converted Koster's method (mice) and the converted Mac Donald's method (mice) induced on the three assumption crossover test. And the following results were found. 1. The same effect of the writhing inhibition in this compounding antipyretic dosage by it's oral administration is as follows. Aminopyrine 100mg/kg. (standard), aminopyrine 50mg/kg compounding with chlorpheniramine maleate 2mg/kg., compounding with diphenhydramine hydrochloride 8mg/kg., compounding with atropine sulfate 0.2mg/kg., or compounding with scopolamine hydrobromide 0.2mg/kg. And aspirin80mg/kg., Salicylamide 90mg/kg., sulpyrine 60mg/kg., or phenacetin 70mg/kg. compounding with the same dosage of the adjutants above. 2. The elevation-rate of the reaction threshold in this compounding antipyretic dosage by it's oral administration calculate as follows. When the elevation-rate (ER) of aminopyrine (100mg./kg.) is 1.00 (Standard), ER of aminopyrine (50mg./kg.) compounding with chlorpheniramine maleate (2mg./kg.) calculated 1.42, aspirin (80.mg./kg.) compounding with diphenhydramine hydrochloride (80mg./kg.) calculated 1.18, salicylamide (90mg./kg.) compounding with chlorpheniramine maleate (2mg./kg.) calculated 1.15, sulpyrine (60mg./kg.) compounding with chlorpheniramine maleate(2mg./kg.) calculated 1.28, and ER phenacetin (70mg./kg.) compounding with chlorpheniramine maleate (2mg./kg.) calculated 1.19.

  • PDF

Influence of N-P-K Nutrient Levels on Ozone Susceptibility of Tomato Plants (N-P-K 양분 수준이 토마토의 오존 감수성에 미치는 영향)

  • Ahn, Joo-Won;Ku, Ja-Hyeong
    • Korean Journal of Environmental Agriculture
    • /
    • v.17 no.4
    • /
    • pp.352-357
    • /
    • 1998
  • This experiment was conducted to find out the effects of major nutrient levels(N, P, K) on ozone susceptibility of tomato plants(Lycopersicon esculentum Mill, cv. Pink Glory). Plants were grown in water culture system. A half-strength of Hoagland's nutrient solution was considered as a standard formulation($N_{100}$ $P_{100}$ $K_{100}$). The levels of major nutrients were adjusted through addition or removal of several fertilizer salts from the standard solution. Top growth was significantly decreased at the low nitrogen level or phosphorus removal condition. P- and K-contents of leaves were greatly decreased by removal of salts containing P and K from the nutrient solution. The rate of ozone injury was significantly increased when potassium was removed. However, the influence of nitrogen and phosphorus levels or high potassium level on injury occurrence did not show statistical significance compared to the standard solution. Ozone exposure resulted in reduction of chlorophyll, and increase of ethylene production, electrolyte leakage and malondialdehyde(MDA) contents. These changes were much more enhanced in plants grown at the potassium removal solution. Whereas the activity of superoxide dismutase(SOD) was low at the potassium removal treatment and this tendency remained after ozone exposure. These results indicated that potassium nutrient level in tomato plants is closely associated with the susceptibility to ozone injury.

  • PDF

A Study on the Validity of 'Hepa-S' Hepatitis B Antibody Detecting Reagent after Vaccination of 'Hepa-Vax' (B형 간염백신 'Hepa-Vax' 접종후 항체검사시약 'Hepa-S' kit의 정확도에 관한 연구)

  • Moon, In-Sook
    • Journal of Preventive Medicine and Public Health
    • /
    • v.18 no.1
    • /
    • pp.51-57
    • /
    • 1985
  • To attempt to measure the effect of domestic product P.H.A. kit 'Hepa-S' after completion of 'Hepa-Vax' vaccination schedule, P.H.A. test and R.I.A. test on the 330 healthy adults were carried out. The results obtained were as follow ; 1. The positive anti HBs rate after completion of 'Hepa-Vax' vaccination were; in P.H.A. test with domestic product P.H.A. kit 81.2%, in P.H.A. test with foreign product P.H.A. kit 82.7%, and in R.I.A. test 95.8% 2. Using the result of R.I.A. test as the standard, sensitivity of P.H.A. test with domestic product P.H.A. kit was 84.8% and specificity was 100.0% 3. Using the result of R.I.A. test as standard, sensitivity of P.H.A. test with foreign P.H.A. kit was 86.4% and specificity was 100.0%. 4. The concordance rate of P.H.A. test with domestic product and foreign product kit was 98.5%. On the result of this study, there was no significant difference in the validity between the domestic product P.H.A. kit 'Hepa-S' and the foreign P.H.A. kit $'Hebsgencell^{TM}'$. So that it is recommendable to use domestic product P.H.A. kit instead of foreign product P.H.A. kit.

  • PDF

Analysis on Sanitation Management Practices in Restaurants in Seoul using the Sanitation Grading System Evaluation Index

  • Kim, Hee-Su;Lee, Ae-Rang;Kim, Gun-Hee
    • Food Quality and Culture
    • /
    • v.3 no.1
    • /
    • pp.27-33
    • /
    • 2009
  • This study evaluates the effectiveness of the "Seoul Sanitation Grading System Evaluation Index" developed earlier and to analyze sanitation management practices in restaurants in Seoul, Korea. The categories evaluated were the food management standard, facilities/equipment standard, and essential checking items specified in the law. These items were graded and classified into A ($100{\sim}90$), B ($89{\sim}80$), C ($79{\sim}70$) and Score (less than 69) based on the criteria set by the present researchers. We randomly selected 56 restaurants in five local cities (Jung-gu, Seocho-gu, Jongno-gu, Songpa-gu and Yeongdeungpo-gu) and investigated each by actually visiting the site of business. The achievement rate for food management standard was 80.8%; as for the specific items in the category, it was the highest in food ingredients at 77.1% and the lowest in food storage at 62.1%. For the facilities/equipment standard, the achievement rate was 77.8%; as for the specific items in the category, it was the highest for vermin at 88.1% and the lowest for operation at 70.8%. The achievement rate for overall individual sanitary management was 70.7% and in the category, the lowest score was seen in hand washing at 57.1%. The overall average score of sanitation management practices using the Seoul Sanitation Grading System Evaluation Index in restaurants in Seoul was 73.7, which fell into the C category. As for the number of restaurants in each grade category, there were 10 (17.9%) in each category of A ($100{\sim}90$), B ($89{\sim}80$) and C ($79{\sim}70$) with 30 (53.6%) scoring higher than 70, whereas those scoring less than 69 included 26 (46.4%). The average scores for those restaurants designated by local governments (exemplary restaurants, general restaurants, best Korean restaurants in Seoul) were not significantly different; however, they were higher in franchises than those small restaurants ran by individuals.

  • PDF

A STUDY ON THE RELIABILITY OF THE OPTICAL CARIES ACTIVITY TEST (광학적 치아우식활성 검사법의 신뢰도에 관한 연구)

  • Park, Cheol-Hong;Lee, Nan-Young;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.4
    • /
    • pp.615-623
    • /
    • 2006
  • The purpose of this study was to evaluate the specificity, sensitivity, and diagnostic power of caries activity test using LED fluorescence. The subjects of this study were 55 children of $6{\sim}7$ years old. LED light were irradiated to labial or buccal surface of all teeth. Fluorescence from initial carious lesion of teeth illuminated by an LED light was observed through barrier filter and the number of teeth showing lesion, size and position of lesion were counted. Streptococcus mutans colony counting and dDfFtT rate test were also done and their correlation was compared. And then specificity, sensitivity, diagnostic power of optical caries activity test using LED light were evaluated. 1. There was positive $correlation({\gamma}=0.43)$ between LED fluorescence test and Streptococcus mutans count(P<0.05). 2. When visual examination was defined to standard testing method, the specificity, sensitivity, diagnostic power of LED fluorescence test were 100%, 76.1%, and 100%. 3. When dDfFtT rate was defined to standard testing method, the specificity, sensitivity, diagnostic power of LED fluorescence test were 88.9%, 47.8%, and 95.7%. 4. When S. mutans colony counting was defined to standard testing method, the specificity, sensitivity, diagnostic power of LED fluorescence test were 100%, 58.7%, and 100%. Considering the above results, optical caries activity test using LED light could be regarded as a practical method because of its close relationship with microbiological caries activity test.

  • PDF

Study on Generator Design for Subsequent Negative Stroke of 0.25/100 ${\mu}s$ (0.25/100 ${\mu}s$ 후속 단시간 뇌격전류 발생기 회로 기술)

  • Lee, Tae-Hyung;Cho, Sung-Chul;Eom, Ju-Hong
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1632-1633
    • /
    • 2011
  • In IEC 62305-1 standard, the simple circuit consisting of RLC is used in order to form the fast rise time of 0.25/100 ${\mu}s$. But this circuit is very expensive system because the system is needed very high charging voltage up to 3.5 MV. In this paper, we suggest the generator which generates the current up to 10 kA by using the low charging voltage of the dozen kV. Therefore the generator was installed then we compared measure results with calculated results.

  • PDF