• Title/Summary/Keyword: S/R Valve

Search Result 123, Processing Time 0.035 seconds

Tunneling Magnetoresistance: Physics and Applications for Magnetic Random Access Memory

  • Park, Stuart in;M. Samant;D. Monsma;L. Thomas;P. Rice;R. Scheuerlein;D. Abraham;S. Brown;J. Bucchigano
    • Proceedings of the Korean Magnestics Society Conference
    • /
    • 2000.09a
    • /
    • pp.5-32
    • /
    • 2000
  • MRAM, High performance MRAM using MTJS demostrated, fully integrated MTJ MRAM with CMOS circuits, write time ~2.3 nsec; read time ~3 nsec, Thermally stable up to ~350 C, Switching field distibution controlled by size & shape. Magnetic Tunnel Junction Properties, Magnetoresistance: ~50% at room temperature, enhanced by thermal treatment, Negative and Positive MR by interface modification, Spin Polarization: >55% at 0.25K, Insensitive ot FM composition, Resistance $\times$ Area product, ranging from ~20 to 10$^{9}$ $\Omega$(${\mu}{\textrm}{m}$)$^{2}$, Spin valve transistor, Tunnel injected spin polarization for "hot" electrons, Decrease of MTJMR at high bias originates from anode.

  • PDF

Installation effects on the characteristics of multi-path ultrasonic flowmeter (배관 형상이 다회선 초음파 유량계의 특성에 미치는 영향)

  • Park, K. A.;Choi, Y. M.;Choi, H. M.;Yoon, B. R.;Hwang, K. B.
    • 유체기계공업학회:학술대회논문집
    • /
    • 1999.12a
    • /
    • pp.114-117
    • /
    • 1999
  • Five-path ultrasonic flowmeters (200 and 300 mm diameters) were tested to obtain it's characteristics in a water flow standard system. A five-path ultrasonic flowmeter was installed after various pipe fittings (elbow, valve, tee) or a pump. The distance between flow disturbance source and a flowmeter was main experimental parameter. Without a flow conditioner, a five-path ultrasonic flowmeter shows good characteristics as the distance between flow disturbance source and a flowmeter is longer than 10 diameter of a flowmeter.

  • PDF

Morpho-molecular characterization of diatom Skeletonema pseudocostatum(Thalassiosirales, Bacillariophyta) from the Korean coast (규조류 Skeletonema pseudocostatum Medlin (Thalassiosirales, Bacillariohyta)의 형태적 특징과 분자계통학적 위치)

  • Han, Kyong Ha;Li, Zhun;Park, Joon Sang;Youn, Joo Yeon;Kim, Hyun Jung;Kwak, Kyeong Yoon;Oh, Seok Jin;Shin, Hyeon Ho
    • Korean Journal of Environmental Biology
    • /
    • v.38 no.1
    • /
    • pp.21-29
    • /
    • 2020
  • Morphology of a strain of unspecified Skeletonema species established from Korean coast was examined by light, fluorescence and scanning electron microscopy, and SSU(small subunit) and LSU(large subunit) rDNA of the strain were also sequenced. The specimen was characterized by solitary or short chains, and each cell contained 1-2 chloroplasts. The valve face was slightly convex, and the terminal fultoportula processes (TFPPs) were open and showed narrow distal ends that could be truncated or spiny with claw-like protrusions. The basal part of the TFPPs was tubular and oblique to the cell axis. The intercalary fultoportula processes (IFPPs) were also narrow, completely open, and joined in a 1 : 1 junction. Occasionally, one IFPP was connected with two opposing IFPPs. The morphological features of the specimen were identical to those of Skeletonema pseudocostatum. Molecular phylogeny based on SSU rDNA revealed that the Korean strain is nested within a clade comprising S. pseudocostatum and S. tropicum. However, based on D1-D2 LSU rDNA sequences, a clade including S. pseudocostatum and a Korean strain was separated from the S. tropicum clade. This indicates that the Korean strain can be identified as S. pseudocostatum. This species represents the first record from Korean coastal waters.

Development of 1-axis Exciter for a Seat Vibration Test of Agricultural Tractors(I) - Design of PID Controller for Position Control of 1-axis Exciter - (농용트랙터용 운전자 좌석 진동 시험을 위한 1축 가진 시험기 개발(I) - 1축 가진 시험기 위치 제어를 위한 PID 제어기 설계 -)

  • Yu, Ji-Hoon;Choi, Young-Kyun;Lee, Kyu-Cheol;Kim, Young-Joo;Ryu, Young-Sun;Ryuh, Kwan-Hee
    • Journal of Biosystems Engineering
    • /
    • v.34 no.5
    • /
    • pp.305-314
    • /
    • 2009
  • The purpose of this paper was to design an effective control system of 1-axis exciter for a seat vibration test of agricultural tractors using MATLAB simulation. The developed simulation model was composed with a hydraulic pump, a hydraulic servo valve, a hydraulic cylinder and load system. Also it was verified by comparing the simulation results with experimental results of actual control system in order to optimize the control performance. And in order to improve its control performance, the designed PID controller in this research was tuned using Ziegler-Nichols 2nd law and zero's moving method of PID controller's transfer function. As the result of these research, the developed position control system was able to control the system's position accurately within 5% errors.

ACTIVATED CARBON CANISTER PERFORMANCE FOR A SPARK IGNITION ENGINE

  • CHOI G. H.;CHOI K. S.;CHUNG Y. J.;KIM I. M.;DIBBLE R. W.;HAN S. B.
    • International Journal of Automotive Technology
    • /
    • v.7 no.1
    • /
    • pp.9-15
    • /
    • 2006
  • Prediction of the performance of a carbon canister in vehicle evaporative emission control system has become an important aspect of overall fuel system development and design. A vehicle's evaporative emission control system is continuously working, even when the vehicle is not running, due to generation of vapors from the fuel tank during ambient temperature variations. Evaporative emissions from gasoline powered vehicles continue to be a major concern. The objective of this paper is to clarity the flow characteristics and other such fundamental data for the canister during loading and purging are needed, and this data will prove valuable in the development of the canister. This paper is to evaluate the relationship between carbon canister condition and engine performance during engine operation, and the effects of evaporative emissions on the engine performance were investigated.

Surgical Treatment of Pulmonary Atresia with Intact Ventricular Septum -Effect of the size of tricuspid valve annulus on the surgical outcome- (영아기에 발견된 심실중격이 온전한 폐동맥 폐쇄증의 외과적 수술요법 술전 삼첨판륜 크기 가 수술 결과에 미치는 영향)

  • 이정렬;윤태진
    • Journal of Chest Surgery
    • /
    • v.29 no.10
    • /
    • pp.1081-1089
    • /
    • 1996
  • Pulmonary atresia with intact ventricular septum has continued to have a high surgical mortality and morbidity. This mAy attribute to the non-uniformity of the anomaly. We reviewed a total of 34 infants with pulmonary atresla and intact ventricular septum managed in this hospital between 1987 and 1995. Mean age and body weight were 57.2 (range, 3-208) days and 4.1 (range, B.3∼6.8) kg. The preoperative Z-value of the diameter of the tricuspid valve was less than -2 in 85.2% of patients and less than -4 in 33. 3% . It is well correlated w th right ventricular cavity size (n=27. r10.68, p< 0.05). Coronary artery-right ventricular fistulas were identified in 3 patients, and right ventricular dependency was suspected in 1 Over All hospital mortality was 23.5%(8/34), although it decreased to 16.6%(4124) in 1990s. Subsequent procedures were performed in 6 patients between 3 days and 58 months after Initial palliation : one bidirectional cavopulmonary shunt and 1 Fontan operation after systemic-pulmonary shunt, 3 transannular patch + atrial septal defect closure and 1 additional systemic-pulmonary shunt after polmonary valvectomy or valvotomy. Changes of Z-values of the diameter of tricuspid valve have been followed up in 11 patients between 1 and 66 months postoperatively. Z-values were increased In 5 out of 8 transannular right ventriculAr outflow tract enlargement group and in 1 out of 3 pulmonary valvectomy or valvotomy group. Our data suggest that tailoring a treatment to right ventricular cavity size and coronary anom lies may improve the surgical outcome. A Z-value of the tricuspid valve diameter could be used.

  • PDF

Research and Development of a 2.9 Liter Light-duty DME Truck Using Common Rail Fuel Injection Systems (커먼레일 연료분사 시스템을 장착한 2.9 리터급 경량 DME 트럭의 연구 및 개발)

  • Jeong, Soo-Jin;Park, Jung-Kwon;Oh, Se-Doo;Lee, Gee-Soo;Lim, Ock-Taek;Pyo, Young-Dug
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.20 no.6
    • /
    • pp.107-116
    • /
    • 2012
  • In this study, the trucks(2.9-liter) have been developed to use DME as fuel, and performance test of the vehicle's DME engine, power, emissions, fuel economy and vehicle aspects was conducted. For experiments, the fuel system(common-rail injectors and high-pressure pump included) and the engine control logic was developed, and ECU mapping was performed. As a result, the rail pressure from 40MPa to approximately 65% increase compared to the base injector has been confirmed that. Also, the pump discharge flow is 15.5 kg/h when the fuel rail pressure is 400rpm(40MPa), and the pump discharge flow is 92.1 kg/h when the fuel rail pressure is 2,000rpm(40MPa). The maximum value of full-load torque capability is 25.5 kgfm(based on 2,000 rpm), and more than 90% compared to the level of the diesel engine were obtained. The DME vehicle was developed in this study, 120 km/h can drive to the stable, and calculated in accordance with the carbon-balance method of fuel consumptions is 5.7 km/L.

A Study on Standards for Pressure Relief Valve Vent Pipes from LPG Storage Tanks (LPG용 압력방출밸브 방출관 설치기준 개선방안)

  • Lee, Jin-Han;Eom, Suk-Hwa;Kim, Lae-Hyun
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.4
    • /
    • pp.59-64
    • /
    • 2012
  • The dispersion of gas discharged from the vent pipes of pressure relief valves attached LPG (Liquefied Petroleum Gas) storage tank was studied. In general, vent pipes should be positioned so that they discharge vertically upwards in a safe place, and installed so that, in the event of ignition of discharged gas, flame impingement on any vessel, equipment or piping is avoided[1][2]. In Korea, on the other hand, there are various type of the end of vent pipes because there is no rule for discharge directions from the vent pipes. In this paper, we took 4 types of vent directions from the pipes in to account, such as vertically upward, vertically downward, vertically 4-way and horizontally 2-way direction. A software package, FLACS, was adopted to simulate gas dispersion from the vent pipes. We found that vertically downward, vertically 4-way and horizontally 2-way discharge from vent pipes were undesirable to avoid ignition on near ground. Therefore, it was obvious that vertically upward opening of a vent pipe is the best option to discharge in a safe place.

Development of a Tool for Predicting the Occurrence Time of BLEVE in Small LPG Storage Tanks (LPG소형저장탱크 BLEVE 발생 시점 예측 툴 개발)

  • Chae, Chung Keun;Lee, Jae Hun;Chae, Seung Been;Kim, Yong Gyu;Han, Shin Tak
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.4
    • /
    • pp.74-83
    • /
    • 2020
  • In Korea, about 110,000 LPG small storage tanks of less than three tons have been installed in restaurants, houses and factories, and are used as LPG supply facilities for cooking, heating and industrial use. In the case of combustible liquefied gas storage tanks, the tank may rupture due to the temperature increase of the tank steel plate (approximately 600℃) even when the safety valve is operating normally, causing large-scale damage in an instant. Therefore, in the event of a fire near the LPG small storage tank, it is necessary to accurately predict the timing of the BLEVE(Boiling Liquid Expanding Vapour Explosion) outbreak in order to secure golden time for lifesaving and safely carry out fire extinguishing activities. In this study, we have first investigated the results of a prior study on the prediction of the occurrence of BLEVE in the horizontal tanks. And we have developed thermodynamic models and simulation program on the prediction of BLEVE that can be applied to vertical tanks used in Korea, have studied the effects of the safety valve's ability to vent, heat flux strength of external fires, size of tanks, and gas remaining in tanks on the time of BLEVE occurrence and have suggested future utilization measures.

Reoperation for congenital heart disease (선천성 심장기형에 대한 2차수술로서의 개심술)

  • Ahn, H.;Sung, S.W.;Kim, Y.J.;Roh, J.R.;Suh, K.P.
    • Journal of Chest Surgery
    • /
    • v.19 no.2
    • /
    • pp.280-287
    • /
    • 1986
  • Between March 1978 and August 1985, 29 cases at various congenital heart diseases were reoperated because of remnant shunt of residual anomalies at Seoul National University Hospital. They were consisted of 10 cases of Tetralogy, 4 simple VSD, 6 complicated VSD. 3 partial ECD, and 5 other rare congenital anomalies. The interval between the initial and the second procedure ranged from 1 day to 122 months [mean; 26.9 months]. In 4 cases of them, the second procedure was done during initial hospitalization within 3 weeks post-operatively. The primary operation intended to be corrective surgery except four whose primary operation was palliative or exploratory one even though it was done with extracorporeal circulation. The indication for second operation was mainly residual shunt or valvular obstruction due to patch detachment or inadequate relief of stenotic lesion. Others were paravalvular leak, valvuloplasty failure, prosthetic valve failure, and inadequate primary diagnosis. Four patients were dead [14.3%]; three complicated VSD`s and one Tetralogy. There were 7 cases of nonfatal complication with subsequent improvement except one [diffuse cerebral dysfunction].

  • PDF