• Title/Summary/Keyword: Rural Energy System

Search Result 204, Processing Time 0.024 seconds

Experimental Analysis on the Performance of a Solar Powered Water Pump (태양열 물펌프의 실험적 성능분석)

  • Kim Y. B.;Son J. G.;Lee S. K.;Kim S. T.;La W. J.;Lee Y. K.
    • Journal of Biosystems Engineering
    • /
    • v.29 no.6 s.107
    • /
    • pp.521-530
    • /
    • 2004
  • The solar powered water pump is very ideal equipment because solar power is more intensive when the water is more needed in summer and it is very helpful in the rural area, in which electrical power is not available. The average solar radiation power is $3.488\;kWh/(m^2{\cdot}day)$ in Korea. In this study, the experimental system of the water pump driven by the radiation energy were designed, assembled, tested and analyzed fur realizing the solar powered water pump. Energy conversion ken radiation energy to mechanical energy by using n-pentane as operating material was done and the water pumping cycles were able to be continued. The quantity of the water pumped per cycle ranged from 2 L to 10 L depending on the level of the valve open area far the vapour supply. The average quantity was about 4,366 cc. The thermal efficiency was about $0.018\%$. The pressure level of the n-pentane vapour in flash tank was about $110\~150\;kPa$ and that in the water tank was $93\~130\;kPa$. The pressure in the condenser during cycles was maintained as about 70 kPa. The condensation of the n-pentane vapour in the water tank was increased with the cycles even though the internal and external insulation were done. Air tank performance was better with increasing of the water piston displacement and the water could be pumped with the water piston displacement becoming higher than 6,500 cc.

Microbiological Safety Assessment of a Perilla Leaf Postharvest Facility for Application of a Good Agricultural Practices (GAP) System (농산물우수관리제도(GAP system) 적용을 위한 깻잎의 수확 후 관리시설(APC)에 대한 미생물학적 안전성 평가)

  • Kim, Kyeong-Yeol;Nam, Min-Ji;Lee, Hyo-Won;Shim, Won-Bo;Yoon, Yo-Han;Kim, Se-Ri;Kim, Doo-Ho;Ryu, Jae-Gee;Hong, Moo-Ki;You, Oh-Jong;Chung, Duck-Hwa
    • Korean Journal of Food Science and Technology
    • /
    • v.41 no.4
    • /
    • pp.392-398
    • /
    • 2009
  • This study identified risk factors of cross-contamination of foodborne pathogens and established a good agricultural practice (GAP) system for an agricultural products processing center (APC) for perilla leaves. All samples were collected before and after a standard work shift at the APC, while perilla leaves were also collected after each step in the APC. In addition, the workers and their surroundings were sampled by swabbing. The total plate count (TPC) and coliform count in the water samples increased significantly (p<0.05) to 3.36 and 1.73 log CFU/mL after work, respectively. However, no Escherichia coli and Listeria monocytogenes were detected. The bacterial populations of the workers and their surroundings did not differ significantly (p${\geq}$0.05) before and after work. However, Staphylococcus aureus (<1.66 log CFU) was detected at a high rate (13-50%) in the basket, packing table, gloves and cloth. Although perilla leaves passed through the washing steps, the TPC and coliform bacterial populations on the final products were higher (p${\geq}$0.05) than those of unwashed perilla leaves, which indicates that the washing system was not functioning properly. Accordingly, a GAP system with a better washing system should be employed at this facility.

Growth Performance of Early Finishing Gilts as Affected by Different Net Energy Concentrations in Diets

  • Lee, Gang Il;Kim, Kwang-Sik;Kim, Jong Hyuk;Kil, Dong Yong
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.28 no.11
    • /
    • pp.1614-1623
    • /
    • 2015
  • The objectives of the current experiment were to study the response of the growth performance of early finishing gilts to different net energy (NE) concentrations in diets, and to compare the NE values of diets between calculated NE values and measured NE values using French and Dutch CVB (Centraal Veevoederbureau; Central Bureau for Livestock Feeding) NE systems. In a metabolism trail, the NE concentrations in five diets used for the growth trial were determined based on digestible nutrient concentrations, digestible energy, and metabolizable energy using a replicated $5{\times}5$ Latin square design with 10 barrows (initial body weight [BW], $39.2{\pm}2.2kg$). In a growth trial, a total of 60 early finishing gilts (Landrace${\times}$Yorkshire; initial BW, $47.7{\pm}3.5kg$) were allotted to five dietary treatments of 8.0, 9.0, 10.0, 11.0, and 12.0 MJ NE/kg (calculated, as-is basis) with 12 replicate pens and one pig per pen in a 42-d feeding experiment. The NE and amino acid (AA) concentrations in all diets were calculated based on the values from NRC (2012). Ratios between standardized ileal digestible AA and NE concentrations in all diets were closely maintained. Pigs were allowed ad libitum access to feed and water. Results indicated that calculated NE concentrations in diets (i.e., five dietary treatments) were close to measured NE concentrations using French NE system in diets. The final BW was increased (linear and quadratic, p<0.05) with increasing NE concentrations in diets. Furthermore, average daily gain (ADG) was increased (linear and quadratic, p<0.01) with increasing NE concentrations in diets. There was a quadratic relationship (p<0.01) between average daily feed intake and NE concentrations in diets. Feed efficiency (G:F) was also increased (linear, p<0.01) as NE concentrations in diets were increased. The NE intake per BW gain (kcal NE/kg of BWG) was increased (linear, p<0.01) with increasing NE concentrations in diets that were predicted from both French and Dutch CVB NE systems. Linear regression indicated that predictability of daily NE intake from the BW of pigs was very low for both French ($R^2$, 0.366) and Dutch CVB ($R^2$, 0.374) NE systems. In conclusion, increasing NE concentrations in diets increase BW, ADG, G:F, and NE intake per BW gain of early finishing gilts. The BW of early finishing gilts is not a good sole variable for the prediction of daily NE intake.

Study on the control technique for the heat transportation system using metal hydride (수소저장합금을 이용한 열수송시스템 제어기술 연구)

  • Sim, K.S.;Kim, J.W.;Kim, J.D.;Myung, K.S.
    • Journal of Hydrogen and New Energy
    • /
    • v.11 no.1
    • /
    • pp.43-49
    • /
    • 2000
  • The heat transportation from a complex of industry to a rural area needs more efficient method because the distance between them is usually more than 10km. Conventional heat transportation using steam or hot water via pipe line has limits in transportation distance (about 3~5 km) because of the heat loss and frictional loss in the pipe line. Metal hydride can absorb or discharge hydrogen through exothermic or endothermic reaction. After releasing hydrogen from metal hydride by means of the waste heat from industry, we can transport this hydrogen to urban area via pipe line. In urban areas, other metal alloy reacts with this hydrogen to form metal hydride and produces heat for heating. Cool heat is also obtained if it is possible to use metal hydride with low reaction temperature. Therefore, metal hydride can be used as a media for transportation and storage of heat. $MmNi_{4.5}Al_{0.5}Zr_{0.003}$, $LaNi_5$, $Zr_{0.9}Ti_{0.1}Cr_{0.6}Fe_{1.4}$, $MmNi_{4.7}Al_{0.1}Fe_{0.1}V_{0.1}$ alloys were selected for this purpose and the properties of those metal hydrides were discussed. The design and control techniques were proposed and discussed for this heat transportation system using metal hydride.

  • PDF

Thermal Conductivity from an in-situ Thermal Response Test Compared with Soil and Rock Specimens under Groundwater-bearing Conditions (지하수 부존지역에서의 토질 및 암석 시료와 현장 열응답시험의 열전도도 비교)

  • Kim, Jin-Sung;Song, Sung-Ho;Jeong, Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.23 no.4
    • /
    • pp.389-398
    • /
    • 2013
  • Studies of the thermal properties of various rock types obtained from several locations in Korea have revealed significant differences in thermal conductivities in the thermal response test (TRT), which has been applied to the design of a ground-source heat pump system. In the present study, we aimed to compare the thermal conductivities of the samples with those obtained by TRT. The thermal conductivities of soil and rock samples were 1.32W/m-K and 2.88 W/m-K, respectively. In comparison, the measured TRT value for thermal conductivity was 3.13W/m-K, which is 10% higher than that of the rock samples. We consider that this difference may be due to groundwater flow because abundant groundwater is present in the study area and has a hydraulic conductivity of 0.01. It is natural to consider that the object of TRT is to calculate the original thermal conductivity of the ground, following the line source theory. Therefore, we conclude that the TRT applied to a domestic standing column type well is not suitable for a line source theory. To solve these problems, values of thermal conductivity measured directly from samples should be used in the design of ground-source heat pump systems.

A Study on Performance Evaluation of a Vertically Closed Deep Geothermal Circulation Simulator (수직 밀폐형 심부지열 순환 시뮬레이터의 성능 평가에 관한 연구)

  • Bae, Jung-Hyeong;Lee, Dong-Woon;Yoon, Chung-Man;Ryoo, Yeon-Su;Jeong, Sang-Hwa
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.15 no.5
    • /
    • pp.8-17
    • /
    • 2016
  • While greenhouses have been utilized as a sustainable alternative to traditional soil farming, they are often powered by diesel boilers that necessitate vast amounts of non-renewable energy and emit toxic fumes. Thus, geothermal heat pumps have been proposed as a more energy-efficient substitution for diesel boilers. Currently, most horticultural facilities in the United States use shallow geothermal systems, and are often equipped with horizontal underground heat exchangers as well as heat pump equipment. These shallow geothermal systems require a large drilling site and heat pump to function, which results in high maintenance costs. The heat pump itself consumes a large amount of power, which degrades system performance. Conversely, high temperatures can be attained within a single borehole in deep geothermal vertical closing systems without using a heat pump. This setup can dramatically reduce the power consumption and improve system performance. In this study, we have modeled a circulation simulator after the circulation systems in deep geothermal facilities to analyze a 2000-meter borehole in Naju-Sanpo-myeon. The simulator is operated by manipulating various putative parameters affecting system performance to analyze the system's coefficient of performance.

Vaccine Cold Chain Monitoring System Using IoT Vaccine Fridge for Developing Countries (IoT 백신 냉장고를 사용한 개발도상국 백신 콜드체인 모니터링 시스템)

  • Lyu, Jang-Hyeon;Park, Samuel;Yu, Jong-Ha;Wang, Xin-Lin;Im, Hyuck-Soon;Rhee, Hyop-Seung;Ahn, Sung-Hoon
    • Journal of Appropriate Technology
    • /
    • v.7 no.1
    • /
    • pp.26-32
    • /
    • 2021
  • In the process of vaccine delivery and vaccination, temperature is mostly controlled by an insulated containers containing ice. Moreover, amount of wasted vaccine is significant because the temperature of the vaccine is not properly controlled. A core challenge of vaccination is temperature data monitoring, since it is critical for managing and operating strategical vaccination by health organizations. In this research, a real-time monitoring vaccine carrier system was developed. Temperature, location, and power consumption data of the vaccine carrier were monitored and working performances of the vaccine carrier were tested in both Korea and Tanzania (Arusha and Kilimanjaro regions). For both places, Short Message Service (SMS) communication method was used to send information of the carrier's status. As a result, the monitoring system was able to transmit and receive real-time data of the vaccine carrier status while the vaccine carrier was tested. The vaccine status data can be accessed from any location through the cloud server and web-based user interface.

Chemical Properties of the Individual Asian Dust Particles Clarified by Micro-PIXE Analytical System

  • Ma, Chang-Jin;Kang, Gong-Unn;Kasahara, Mikio;Tohno, Susumu
    • Asian Journal of Atmospheric Environment
    • /
    • v.8 no.3
    • /
    • pp.154-161
    • /
    • 2014
  • The present study was undertaken to evaluate the chemical characteristics of Asian dust (hereafter called "AD") particles with the aid of the most advanced micro-PIXE (Particle-induced X-ray emission) analytical technique. To this end, size-selected particles were sampled on a rural peninsula of Korea (Byunsan, 35.37N; 126.27E) during AD and non-AD periods in 2004. The coarse particle (> $2{\mu}m$) number density during an AD event were 170 times higher than those of the non-AD counterpart. The average net-count of silica in individual particles collected on AD event was roughly 11 times higher than that of non-AD counterpart. The X-ray net-counts of trace elements (Zn, Co, Mn, and V) were also considerably high in AD relative to the non-AD day. Particle classification based on the inter ratio analysis of elemental net-count suggests that a large portion of the coarse particles collected during AD event underwent chemical transformation to a certain degree. The visual interpretation of micro-PIXE elemental maps and elemental localization data in and/or on individual AD particles clarified the internal mixture of AD particles with sea-salt and artificial metallic particles.

Evaluation and Analysis of The Building Energy Saving Performance by Component of Wood Products Using EnergyPlus (EnergyPlus를 이용한 건물 부위별 목질제품 적용에 따른 건축물 에너지 절감 기여도 평가)

  • Seo, Jungki;Wi, Seunghwan;Kim, Sumin
    • Journal of the Korean Wood Science and Technology
    • /
    • v.44 no.5
    • /
    • pp.655-663
    • /
    • 2016
  • Increasing green house gas and it consequent climate change problems are discussed as a global issue. Accordingly, future local green house gas emission will increase up to 40% of the entire local green house gas emission and therefore, efforts to reduce the emission in construction industry is urgently required. Therefore, in this study, heating energy demand was analyzed by using the EnergyPlus simulation according to wood material finishes configuration. EnergyPlus has the entry for a variety of buildings and heating, ventilation, air conditioning (HAVC) system components, in particular buildings, air conditioning systems, and performs simultaneous integrated calculated through the feedback between the heat source unit, a verification program according to the ASHRAE Standard 140-2007 to be. The climate data for the simulation we used the data IWEC in Incheon and Gwangju provided by EnergyPlus. The analysis of simulation model was farm and fishing house standard design drawings: 2012, presented at the Korea Rural Community Corporation. The results of simulation of central region and southern region were effected by wood products of simulation model into the interior finish, exterior finish, windows, wooden structure. Also, it was confirmed that the reduced heating energy demand.

A Study on the Environmental Philosophy and the Ecological Planning for Housing Developments (환경철학의 이해와 생태적 주거의 계획기법에 관한 연구)

  • 현택수
    • Journal of the Korean housing association
    • /
    • v.10 no.4
    • /
    • pp.147-159
    • /
    • 1999
  • As we have come to realize the problems caused by the modern civilization as well as the importance of the preservation of nature. Ecological building and urban design come to attract more attention. Therefore, the object of this study is providing the design factors and improving the design methods for the developments of ecological housing complex, harmonious with environment. Followings are the results of this study: 1. We need to turn to new trend-Ecological architecture which enables the co-exitence of nature and human being to come over the presence and face new decades. 2. Ecological architecture is based on energy-saving system and give people a healty and comfortable atmosphere. 3. In the city area, the house development should be undertaken to minimize the environmental problem through extremely high ehhiciency and technonogy. 4. We need a new development to preserve natural environment in the suburvan and small or medium city. 5. We have to develope the approach method, which is to maintain the frame of present ecological environment, to be in sympathy with geomorphology, to use the natural material in the rural community.

  • PDF