• 제목/요약/키워드: Rupture Life

검색결과 270건 처리시간 0.021초

Spontaneous Splenic Rupture in a Vivax Malaria Case Treated with Transcatheter Coil Embolization of the Splenic Artery

  • Kim, Na Hee;Lee, Kyung Hee;Jeon, Yong Sun;Cho, Soon Gu;Kim, Jun Ho
    • Parasites, Hosts and Diseases
    • /
    • 제53권2호
    • /
    • pp.215-218
    • /
    • 2015
  • An enlarged spleen is considered one of the most common signs of malaria, and splenic rupture rarely occurs as an important life-threatening complication. Splenectomy has been recommended as the treatment of choice for hemodynamically unstable patients. However, a very limited number of splenic rupture patients have been treated with transcatheter coil embolization. Here we report a 38-year-old Korean vivax malaria patient with ruptured spleen who was treated successfully by embolization of the splenic artery. The present study showed that angiographic embolization of the splenic artery may be an appropriate option to avoid perioperative harmful effects of splenectomy in malaria patients.

Mg-Zn-Mn-(Ca)합금의 크리이프 변형거동에 관한 연구 (A Study on the Creep Deformation Behavior of Mg-Zn-Mn-(Ca) Alloys)

  • 강대민;구양;심성보
    • 한국자동차공학회논문집
    • /
    • 제14권5호
    • /
    • pp.73-78
    • /
    • 2006
  • In this paper, creep tests of Mg-Zn-Mn and Mg-Zn-Mn-Ca alloys, which were casted by mold with Mg-3%Zn-1%Mn and Mg-3%Zn-1%Mn-0.2%Ca, were done under the temperature range of 473-573K and the stress range of 23.42-78.00Mpa. The activation energies and the stress exponents were measured to investigate the creep plastic deformation of those alloys, and the rupture lifes of Mg-Zn-Mn alloy were also measured to investigate the fracture behavior. From the results, the activation energy of Mg-Zn-Mn and Mg-Zn-Mn-Ca alloys under the temperature range of 473-493K were measured as 149.87, 145.98KJ/mol, respectively, and the stress exponent were measured as 5.13, 6.06 respectively. Also the activation energies Mg-Zn-Mn and Mg-Zn-Mn-Ca alloys under the temperature range of 553-573K were obtained as 134.41, 129.22KJ/mol, respectively, and tress exponent were obtained as 3.48, 4.63, respectively. Finally stress dependence of rupture life and the activation energy of rupture life of Mg-Zn-Mn under the temperature range of 473-493K was measured as 8.05, 170.0(KJ/mol), respectively, which were a little higher than the results of steady state creep.

Delayed rupture of a posttraumatic retromaxillary pseudoaneurysm causing massive bleeding: a case report

  • Hwang, Jae Ha;Kim, Woo Hyeong;Choi, Jun Ho;Kim, Kwang Seog;Lee, Sam Yong
    • 대한두개안면성형외과학회지
    • /
    • 제22권3호
    • /
    • pp.168-172
    • /
    • 2021
  • Posttraumatic pseudoaneurysm of the face is caused by blunt, penetrating, or surgical trauma. Although its incidence is low, pseudoaneurysm rupture can cause a life-threatening, massive hemorrhage. A 48-year-old man visited our emergency center due to a fall-down accident. Three-dimensional computed tomography (CT) showed a comminuted zygomaticomaxillary complex fracture of the left face. After open reduction and internal fixation, the surgical wound healed without any complications. However, the patient was readmitted 10 days after surgery due to pus-like discharge from the wound. Contrast-enhanced CT to find the abscess unexpectedly revealed a pseudoaneurysm in the left retromaxillary area. Massive oral bleeding occurred on the night of re-hospitalization and emergency surgery was done. The bleeding site was identified as a pseudo-aneurysmal rupture of the posterior superior alveolar artery in the retromaxillary area. Hemostasis was achieved by packing Vaseline gauze in the maxillary sinus using an endoscope. Delayed rupture and massive bleeding of posttraumatic retromaxillary pseudoaneurysm after a zygomaticomaxillary fracture is a low-probability, but high-impact event. Therefore, additional contrast-enhanced CT should be considered to evaluate the possibility of a posttraumatic pseudoaneurysm in cases of severe comminuted zygomaticomaxillary fracture.

Al-Zn-Mg 3원계 알루미늄 합금의 크리프 거동 (Creep Behaviour of Al-Zn-Mg Ternary Aluminum Alloy)

  • 윤종호;황경충
    • 한국자동차공학회논문집
    • /
    • 제12권1호
    • /
    • pp.203-208
    • /
    • 2004
  • To make practical applications of Al-Zn-Mg ternary aluminum alloy effectively in various field, a series of static creep tests under the 16 temperature-stress combination conditions had been performed. The creep tester with constant stress loading was designed and made by the authors and used in this study. The higher the creep temperature rose, the less the stress exponents became. The bigger the applied stresses became, the less values the creep strain activation energy showed. The life prediction constant of Larson-Miller parameter was calculated as about 2.3. In the fractography, the ductile fracture with dimples by intergranular breakage was primarily observed. We can make practical use of these test data in the design, the life prediction and the prevention of the accidents of the thermal facilities, etc.

Blunt Traumatic Cardiac Rupture: Single-Institution Experiences over 14 Years

  • Yun, Jeong Hee;Byun, Joung Hun;Kim, Sung Hwan;Moon, Sung Ho;Park, Hyun Oh;Hwang, Sang Won;Kim, Yong Hwan
    • Journal of Chest Surgery
    • /
    • 제49권6호
    • /
    • pp.435-442
    • /
    • 2016
  • Background: Blunt traumatic cardiac rupture is rare. However, such cardiac ruptures carry a high mortality rate. This study reviews our experience treating blunt traumatic cardiac rupture. Methods: This retrospective study included 21 patients who experienced blunt traumatic cardiac rupture from 1999 to 2015. Every patient underwent surgery. Several variables were compared between survivors and fatalities. Results: Sixteen of the 21 patients survived, and 5 (24%) died. No instances of intraoperative mortality occurred. The most common cause of injury was a traffic accident (81%). The right atrium was the most common location of injury (43%). Ten of the 21 patients were suspected to have cardiac tamponade. Significant differences were found in preoperative creatine kinase-myocardial band (CK-MB) levels (p=0.042) and platelet counts (p=0.004) between the survivors and fatalities. The patients who died had higher preoperative Glasgow Coma Scale scores (p=0.007), worse Trauma and Injury Severity Scores (p=0.007), and higher Injury Severity Scores (p=0.004) than those who survived. Conclusion: We found that elevated CK-MB levels, a low platelet count, and multi-organ traumatic injury were prognostic factors predicting poor outcomes of blunt cardiac rupture. If a patient with blunt traumatic cardiac rupture has these factors, clinicians should be especially attentive and respond promptly in order to save the patient's life.

사형주조한 Mg-Nd-Zr-Zn합금의 고온 크리이프강도 (High Temperature Creep Strength of Mg-Nd-Zr-Zn Alloy in Sand Castings)

  • 강대민;박경도;박지희
    • 한국기계가공학회지
    • /
    • 제10권6호
    • /
    • pp.83-88
    • /
    • 2011
  • Magnesium alloys have been focussed for the applications for lightweight of vehicle and electronics due to their high strength, low specific density and good damping capacity. This paper deals with the creep strength of Mg-Nd-Zr-Zn alloy. For the alloy, pure magnesium(99.9%) was melt with atmosphere of $0.3%SF_6$ and $25%CO_2$. After melting, 0.3% of zinc was inserted to stir for 10min at elevated temperature of $770^{\circ}C$. Master alloys of Mg-15%Nd and Mg-15%Zr were stirred in furnace. The creep tests were performed to obtain creep rate and rupture in the temperature range of 200 to $220^{\circ}C$ and 280 to $310^{\circ}C$ at an applied stress of 156 to 172MPa and 78 to 94MPa, respectively. The deformation mechanism was predicted dislocation climb from measured apparent activation energy and stress exponent. Also the increaser the temperature and stress the lower the stress exponent and activation energy. Finally, LMP parameter gives good information for the predicted creep rupture life.

외상성 하행대동맥류 수술치험 1례 (Traumatic descending aortic aneurysm -Report of one case-)

  • 이신영
    • Journal of Chest Surgery
    • /
    • 제24권5호
    • /
    • pp.505-509
    • /
    • 1991
  • Rupture or laceration of the aorta is a more common result of nonpenetrating traumatic injury than is generally appreciated. If the lesion is promptly diagnosed, a appropriate surgical treatment may be life-saving. Diagnosis may be difficult and at times the rupture may remain clinically silent for variable period.< A 34 - year old male patient had sustained steering wheel injury to his chest during automobile accident 8 weeks prior to admission. The diagnosis of traumatic aneurysm of the aorta was delayed as he was asymptomatic. Surgical repair of false aneurysm of the descending aorta was successfully performed by partial cardiopulmonary bypass through the femoral artery and vein.

  • PDF

Huge gastric mucosal laceration during endoscopy in a patient with hiatal hernia

  • Inmo Kang
    • Journal of Medicine and Life Science
    • /
    • 제21권2호
    • /
    • pp.49-52
    • /
    • 2024
  • Massive gastric mucosal ruptures during upper gastrointestinal endoscopy in patients with esophageal hiatal hernias are rare. However, tearing of the gastric mucosa alone, without tearing of the gastroesophageal junction, is even rarer. This study reports a case of a large mucosal rupture that occurred on the posterior wall of the upper body of the stomach during upper gastrointestinal endoscopy in an 83-year-old woman with an esophageal hiatal hernia while sedated. The patient was treated with endoclips for the rupture.

Alloy 690 증기발생기 전열관 재료의 크리프 거동 평가 (Evaluation of Creep Behaviors of Alloy 690 Steam Generator Tubing Material)

  • 김종민;김우곤;김민철
    • 한국압력기기공학회 논문집
    • /
    • 제15권2호
    • /
    • pp.64-70
    • /
    • 2019
  • In recent years, attention has been paid to the integrity of steam generator (SG) tubes due to severe accident and beyond design basis accident conditions. In these transient conditions, steam generator tubes may be damaged by high temperature and pressure, which might result in a risk of fission products being released to the environment due to the failure. Alloy 690 which has increased the Cr content has been replaced for the SG tube due to its high corrosion resistance against stress corrosion cracking (SCC). However, there is lack of research on the high temperature creep rupture and life prediction model of Alloy 690. In this study, creep test was performed to estimate the high temperature creep rupture life of Alloy 690 using tube specimens. Based on manufacturer's creep data and creep test results performed in this study, creep life prediction was carried out using the Larson-Miller (LM) Parameter, Orr-Sherby-Dorn (OSD) parameter, Manson-Haford (MH) parameter, and Wilshire's approach. And a hyperbolic sine (sinh) function to determine master curves in LM, OSD and MH parameter methods was used for improving the creep life estimation of Alloy 690 material.

Delayed Pulmonary Artery Rupture after Using BioGlue in Cardiac Surgery

  • Woo, Wongi;Hong, Soonchang;Kim, Tae-Hoon;Baek, Min-Young;Song, Suk-Won
    • Journal of Chest Surgery
    • /
    • 제50권6호
    • /
    • pp.474-476
    • /
    • 2017
  • A 56-year-old woman, who underwent cardiac surgery 3 months previously, presented to the emergency room with pulmonary artery rupture due to the cytotoxic effects of BioGlue (CryoLife Inc., Kennesaw, GA, USA). She was successfully treated with surgical management. Although surgical glue can be effectively used for hemostasis, it can induce delayed vascular complications. Therefore, surgical glue should be used cautiously.