• Title/Summary/Keyword: Ruby laser system

Search Result 5, Processing Time 0.023 seconds

Development of 4Hz Medical Ruby Laser System with Double Cavities using Multi-Resonant Converter (다중 공진형 컨버터를 이용한 이중 캐비티 구조의 4Hz 의료용 루비레이저 시스템 개발)

  • Lee, Jae-cheol;Zheng, Tao;Shengxu, Piao;Xu, Guo-Cheng;Kim, Hee-Je
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.8
    • /
    • pp.1207-1211
    • /
    • 2015
  • Various laser systems have been widely used in almost all industrial technologies because they have high energy density, directivity and coherence. Recently the clinical application is becoming wider in medical parts such as incurable disease, diagnosis and so on. Generally, ruby laser beam has the greatest efficacy for removing tattoos, freckle and other skin problem. But current medical ruby laser system has the maximum repetition rate of 2Hz and optical output beam energy of 1J. Many medical doctors really want to have a high repetition ruby laser system because that can reduce the operation time. We investigated a new ruby laser system with high repetition rate of 4Hz using double cavities. Furthermore, we develop a new power supply system adopting zero voltage switching(ZVS) to minimize switching loss by LLC resonant converter designed as 2kW class.

Fabrication of Compact Ruby Laser and its Operation Characteristics (플라즈마 진단용 소형 루비레이저의 제작과 동작특성에 관한 연구)

  • Jin, Yun-Sik;Kim, Hee-Je
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1271-1274
    • /
    • 1995
  • In this paper, design feature and operation characteristics of compact Ruby laser for plasma diagonostics are described. A linear Xe flashlamp and a single elliptical cavity are adopted as optical pumping system. With charging energy of 484J, the maximum output energy of 170mJ, laser pulse width $110{\mu}s$, and slope efficiency 0.09% were obtained. If Q-switch system is added to this laser, we suppose this laser will be quite enough for diagonizing plasma.

  • PDF

Transient Analysis of Five-Layer System Laser Amplifier (오층구조 레이저 증폭기의 과도현상론적해석)

  • 김영권
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.3 no.4
    • /
    • pp.16-24
    • /
    • 1966
  • The LASER Amplifier is treated in the manner of a Fabry-Perot Resonator with an active media, five layers are considered: air, reflector, active medium(ruby), reflector and air. One dimensional scalar wave equations are derived using the method of boundary value probrems in which it is assumed that incident coherent radiation falls normally on the surface wall. All equations are treated from the transient analysis point of view using the Laplace transform nethods, and are arranged steady state region as an amplifier and transient region as a self excited oscillator. Also some remarks are given on the design problem of LASER amplifier in connection with the transient terms involved.

  • PDF

Nano-scale Proteomics Approach Using Two-dimensional Fibrin Zymography Combined with Fluorescent SYPRO Ruby Dye

  • Choi, Nack-Shick;Yoo, Ki-Hyun;Yoon, Kab-Seog;Maeng, Pil-Jae;Kim, Seung-Ho
    • BMB Reports
    • /
    • v.37 no.3
    • /
    • pp.298-303
    • /
    • 2004
  • In general, a SYPRO Ruby dye is well known as a sensitive fluorescence-based method for detecting proteins by one-or two-dimensional SDS-PAGE (1-DE or 2-DE). Based on the SYPRO Ruby dye system, the combined two-dimensional fibrin zymography (2-D FZ) with SYPRO Ruby staining was newly developed to identify the Bacillus sp. proteases. Namely, complex protein mixtures from Bacillus sp. DJ-4, which were screened from Doen-Jang (Korean traditional fermented food), showed activity on the zymogram gel. The gel spots on the SYPRO Ruby gel, which corresponded to the active spots showing on the 2-D FZ gel, were analyzed by a matrix-assisted laser desorption ionization time of flight (MALDI-TOF) mass spectrometric analysis. Five intracellular fibrinolytic enzymes of Bacillus sp. DJ-4 were detected through 2-D FZ. The gel spots on the SYPRO Ruby dye stained 2-D gel corresponding to 2-D FZ were then analyzed by MALID TOF MS. Three of the five gel spots proved to be quite similar to the ATP-dependent protease, extracellular neutral metalloprotease, and protease of Bacillus subtilis. Also, the extracellular proteases of Bacillus sp. DJ-4 employing this combined system were identified on three gels (e.g., casein, fibrin, and gelatin) and the proteolytic maps were established. This combined system of 2-D zymography and SYPRO Ruby dye should be useful for searching the specific protease from complex protein mixtures of many other sources (e.g., yeast and cancer cell lines).

Construction of Laser-heated Pedestal Growth System for Single Crystal Fibers (Fiber형 단결정 성장을 위한 LHPG 장치의 제작)

  • 임기수
    • Korean Journal of Optics and Photonics
    • /
    • v.4 no.1
    • /
    • pp.114-119
    • /
    • 1993
  • We constructed a laser-heated pedestal growth station using a 25 W $CO_2$ laser to grow various single crystal fibers. The LHPG system consists of the optical system which includes a reflaxicon, an elliptic mirror and a parabolic mirror with their centers drilled, and the translation system to move a source and a seed independently. To test the system, we pulled a few ruby fibers with diameter of 600 ${\mu}m$ and length of 2 cm, and studied characteristics of their photoluminescence.

  • PDF