• 제목/요약/키워드: Rubber Materials

검색결과 1,022건 처리시간 0.027초

TENSILE BOND STRENGTH BETWEEN ELASTOMERIC IMPRESSION MATERIALS AND TRAY RESINS DEPENDING ON THE THICKNESS OF THE TRAY ADHESIVE

  • Kim, Tae-Won;Moon, Hong-Seok;Lee, Keun-Woo;Chung, Moon-Kyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • 제44권6호
    • /
    • pp.699-711
    • /
    • 2006
  • Statement of problem. Elastomeric impression materials have been widely used to obtain an accurate impression. However there have not been enough studies on the influence of the thickness of the tray adhesives on the bonding strength between the trays and the elastomeric impression materials. Purpose. In order to understand the relationship between the thickness of the tray adhesive and the tensile bond strength and to suggest the thickness at which the bonding strength is strongest, tensile bond strength related to the thickness of adhesives of 3 different elastomeric impression materials were tested. Materials and methods. 3 impression materials, $Permlastic^{(R)}$. Regular Set(Kerr Corp., Romulus, Michigan, U.S.A.), $Impregum^{TM}$ $Penta^{TM}$(3M ESPE, Seefeld, Germany), and Aquasil Ultra Monophase Regular Set Smart Wetting.(Dentsply Caulk, Milford, Delaware, U.S.A.), were used in this study, and tray adhesives from the same manufacturers of the impression materials were used, which were Rubber Base Adhesive, Polyether Adhesive, and Silfix, respectively. The tray specimens were prepared by autopolymerizing the tray material(Instant Tray Mix, Lang, Wheeling, Illinois, U.S.A.), and a PVC pipe was used to house the impression material. In group A, tray adhesives were applied in multiple thin layers of 1 to 5 and in group B, adhesives were applied only once, in the thickness equivalent to several applications. Lightness($L^*$) of the adhesion surface was measured with a spectrophotometer(CM-3500d, Konica Minolta, Sakai, Osaka, Japan). The tensile bond strength of the elastomeric impression material and the tray resin was measured with universal materials testing machines(Instron, Model 3366, Instron Corp, Nowood, Massachusetts, U.S.A.). A formula between the number of adhesive application layers and the lightness of the adhesion surface was deduced in group A, and the number of adhesive layers in group B was estimated by applying the lightness($L^*$) to the deduced formula. Results. 1. In group A, a statistically significant increase in tensile bond strength appeared when the number of application layers increased from 1 to 2 and from 4 to 5, and no significant difference was present between 2, 3, and 4 layers in Permlastic. In Impregum, the tensile bond strength was significantly increased when the number of adhesive layers increased from 1 to 3, but no significant difference after 3 layers. In Aquasil, the tensile bond strength significantly increased as the number of application layers increased up to 4 but showed no significant difference between 4 and 5. 2. In group B, the tensile bond strength was decreased when the thickness of the adhesive increased in Permlastic. Impregum showed an increased tensile bond strength when the thickness of the adhesive was increased. In Aquasil, the tensile bond strength increased as the number of adhesive application layers increased up to approximately 2.5 layers but it sharply decreased after approximately 4.5. Conclusion. From the study, the common idea that it is better to apply a thin and single coat of tray adhesive needs correction in more detailed ways, and instructions on some of the tray adhesives should be reconsidered since there were several cases in which the tensile bond strength increased according to the increase in the thickness of the adhesives.

Mechanisms of Platelet Adhesion on Elastic Polymer Surfaces: Protein Adsorption and Residence Effects

  • Insup Noh;Lee, Jin-Hui
    • Macromolecular Research
    • /
    • 제9권4호
    • /
    • pp.197-205
    • /
    • 2001
  • Platelet adhesion onto elastic polymeric biomaterials was tested in vitro by perfusing human whole blood at a shear rate of 100 sec$\^$-1/ for possible verification of mechanisms of initial platelet adhesion perfusion of blood on the polymeric substrates was performed after treatments either with or without pre-adsorption of 1% blood plasma, and either with or without residence of the protein-preadsorbed substrate in phosphate buffered solution. The surfaces employed were elastic polymers such as poly(ether urethane urea), poly(ether urethane), silicone urethane copolymer, silicone rubber and poly(ether urethane) with the anti-calcifying agent hydroxyethane bisphosphate. Each polymer surface treated was exposed in vitro to the dynamic, heparinized whole blood perfused for upto 6 min and the surface area of platelets initially adhered was measured by employing in situ epifluorescence video microscopy. The blood perfusion was performed on the surfaces treated at the following three different conditions: directly on the bare surfaces, after protein pre-adsorption and after residence in buffer for 3 days of the surfaces protein pre-adsorbed for 2 h. The effects of blood plasma pre-adsorption on the initial platelet adhesion was surface-dependent. The amount of the adsorbed fibrinogen and the surface coverage area of the adhered platelets were dependent on the surface conditions whether substrates were bare surfaces or protein pre-adsorbed ones. To test an effect of possible morphological (re)orientations of the adsorbed proteins on the initial platelet adhesion, the polymeric substrate pre-adsorbed with 1% blood plasma was immersed in phosphate buffered solution for 3 days and then exposed to physiological blood perfusion. The surface area of the platelets adhered on these surfaces was significantly different from that of the surfaces treated with protein pre-adsorption only. These results indicated that platelet adhesion was dependent on the surface property itself and pre-treatment conditions such as blood perfusion without any pre-adsorption of proteins, and blood perfusion either after protein pre-adsorption or after subsequent substrate residence in buffer of the substrate pre-adsorbed with proteins. Understanding of these results may guide for better designs of blood-contacting materials based on protein behaviors.

  • PDF

Measurement of Surface Strain on Soft Biological Tissues Using Irregular Grid Pattern (불규칙적인 격자망을 이용한 생체 연조직의 곡면변형률 측정)

  • Lee, Jun Sik;Kim, Ki Hong;Kim, Hyung Jong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • 제37권8호
    • /
    • pp.1051-1057
    • /
    • 2013
  • In this study, an automatic surface-strain measurement system called "ASIAS-bio" has been developed. This system can be used even in cases in which it is very difficult to apply a regular grid pattern necessary for measuring surface-strain, such as curved or uneven surfaces; surfaces damaged by corrosion or contamination; or soft materials such as rubber, foam, and biological tissues. This system works independently of the measurement conditions including the material and its surface condition, grid pattern and size, grid marking method, and degree of deformation. A comparison between the strain distributions of the sheet metal parts measured by using this system and those obtained by a commercial system showed that this system was sufficiently reliable. In addition, the deformation of the swine joint capsule and human knee skin was measured by using this system to demonstrate its usefulness.

Noise Analysis and Reduction Methods of the All-in One Window Ventilation System (창호일체형 환기장치의 소음분석 및 저감방안)

  • Park, Chan-Jae;Haan, Chan-Hoon
    • The Journal of the Acoustical Society of Korea
    • /
    • 제32권1호
    • /
    • pp.43-55
    • /
    • 2013
  • The window ventilation system based on the heat recovery device was developed which make air ventilation possible without opening the windows. However, mechanical and aerodynamic noises were come to pass which annoyed people in rooms. In the present study, noise of new window ventilation system was measured in both general room and anechoic chamber. Also, the noise path was detected to find cause of noise generation and vulnerable area of the device. Sound absorptive and insulation materials were applied to mitigate the noise. Finally, an alternative noise control method was suggested which can satisfy with the indoor noise standards. As a result, it was shown that the cause of noise was the low transmission loss in the ventilation system. As a result, it was shown that the main noise source of the ventilation system was the blower and the major cause of noise was the low transmission loss of the ventilation system. It is also concluded that the noise levels complies with the noise standards of 40 dBA when 2 mm rubber sheet is applied inside the ventilation system.

Analysis and Reduction Method of Noise from Head of a Combine Harvester (콤바인 전처리부의 소음 분석과 감소 방안)

  • Kim, Ho-Jung;Park, Young-Joon;Shim, Sung-Bo;Kim, Kyeong-Uk
    • Journal of Biosystems Engineering
    • /
    • 제32권3호
    • /
    • pp.153-159
    • /
    • 2007
  • This study was conducted to measure and analyze the noise from a combine head. The combine head, comprised of a cutting knife assembly, pick-up chains, horizontally conveying chains and vertically conveying chains, had an overall sound level of 101 dBA. The sound levels of each component were, respectively, 98.3 dBA for the cutting knife assembly, 88.9 dBA for the pick-up chains, 79.8 dBA for the horizontally conveying chains and 86.3 dBA for the vertically conveying chains, being equivalent to 54.4%, 18.4%, 6.5% and 13.7% of the overall head noise. The main cause of the head noise was considered the impacts that the joint of the cutting knife assembly made with frame when it oscillated. The impact sound was also generated when the chain lug collided with the chain case. To reduce these impact sound, anti-vibration rubbers were installed on the knife assembly joint and the chain cases. It reduced the head noise by 4 dBA but the overall noise level of the combine head was still high. In order to protect the combine operators more effectively from the noise, a safety cab needs to be installed on the combine.

A Study on Enhancement of the Durability of Permeable Pavement Material (투수성 도로포장재의 내구성 향상에 관한 연구)

  • Oh, Hun-Su;Hong, Young-Keun
    • Elastomers and Composites
    • /
    • 제42권2호
    • /
    • pp.93-101
    • /
    • 2007
  • In this study, for enhancing the durability of permeable pavement material polyurethane(PU) adhesives were developed, and the physical properties upon polymerization and additives were studied. PU polymerization followed the bulk polymerization of free solvent type considering ecological aspect. Additives used in this study were carbon black, calcium carbonate and ultra violet stabilizer. The property changes upon different environment were evaluated with the compressive strength which is the principal measurement of the property of pavement materials. Among polymerized PU, one formulated with esterpolyol and crosslinkable chain extender gave the highest compressive strength of $74.9kgf/cm^2$, better than commercial $60kgf/cm^2$. The strength was the highest when the material specimen contained carbon black and calcium carbonate 20 wt%, respectively. However, UV stabilizer did not show good weathering properties.

Manufacturing a Functional Bolus Using a 3D printer in Radiation Therapy (방사선치료에서 3D 프린터를 이용한 기능적 조직보상체의 제작)

  • Lee, Yi-Seong;Kim, Jeong-Koo
    • Journal of radiological science and technology
    • /
    • 제43권1호
    • /
    • pp.9-14
    • /
    • 2020
  • Commercial plate bolus is generally used for treatment of surface tumor and required surface dose. We fabricated 3D-printed bolus by using 3D printing technology and usability of 3D-printed bolus was evaluated. RT-structure of contoured plate bolus in the TPS was exported to DICOM files and converted to STL file by using converting program. The 3D-printed bolus was manufactured with rubber-like translucent materials using a 3D printer. The dose distribution calculated in the TPS and compared the characteristics of the plate bolus and the 3D printed bolus. The absolute dose was measured inserting an ion chamber to the depth of 5 cm and 10 cm from the surface of the blue water phantom. HU and ED were measured to compare the material characteristics. 100% dose was distributed at Dmax of 1.5 cm below the surface when was applied without bolus. When the plate bolus and 3D-plate bolus were applied, dose distributed at 0.9 cm and 0.8 cm below the surface of the bolus. After the comparative analysis of the radiation dose at the reference depth, differences in radiation dose of 0.1 ~ 0.3% were found, but there was no difference dose. The usability of the 3D-printed bolus was thus confirmed and it is considered that the 3D-printed bolus can be applied in radiation therapy.

Alignment System Development for producing OLED using Fourth-Generation Substrate

  • Park, Jae-Yong;Han, Seok-Yoon;Lee, Nam-Hoon;Choi, Jeong-Og;Shin, Ho-Seon
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2008년도 International Meeting on Information Display
    • /
    • pp.873-878
    • /
    • 2008
  • Doosan Mecatec has developed alignment system for Organic Light-Emitting Diode (OLED) display production using large size substrate. In the present article, The alignment system between the substrate and the mask, which is a core technology for producing the OLED product using the fourth-generation substrate with $730{\times}920mm^2$ or more, will be described by dividing into a substrate loader, a magnet unit, a CCD camera, etc. The substrate loader is optimized through the simulation where the central portion of the substrate droops by about 1.5mm by clamping each of a long side (920mm direction) and a short side (730mm direction) thereof by 6 point and 4 point. A magnet unit using a sheet type of rubber magnet is constituted and a CCD camera model with the specifications capable of minimizing the errors between a clear image and the same image is selected. The system to which an upward evaporation technique of small molecular organic materials will be applied has been developed so that repeatability and position accuracy becomes ${\pm}1{\mu}m$ or less using an UVW type of stage. Also, the vision accuracy of the CCD camera becomes ${\pm}1{\mu}m$ or less and the align process TACT becomes 30sec. or less so that the final alignment accuracy between the substrate and the mask becomes ${\pm}3{\mu}m$ or less. In order to meet an extra-large glass substrate, an evaporation system using an extra-large AMOLED substrate has been developing through a vertical type of an alignment system.

  • PDF

FABRICATION OF TISSUE ENGINEERED MYO-MUCOSAL FLAP BY GRAFTING THE COMPLEX OF AUTOLOGOUS ORAL KERATINOCYTES AND PLATELET RICH PLASMA(PRP) IN A RAT MODEL (백서에서 자가 구강점막세포와 혈소판 농축 혈장의 이식에 의한 점막 근 피판의 조직공학적 제작)

  • Lee, Bu-Kyu;Hwang, Jin-Hyuk
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제33권4호
    • /
    • pp.322-330
    • /
    • 2007
  • Backgrounds: To overcome limited amount of autogenous mucosa for the reconstruction of various mucosal defect including oral mucosal defect, tissue engineered mucosa has been recently introduced. However, introduced conventional technique of tissue engineered mucosa still have serious pitfalls such as long fabrication time, fragility of the reconstructed mucosa, and complexity of the technique. Aim of the study: To examine whether the complex of preconfluent autologous keratinocytes and autologous PRP(Platelet rich plasma) can reconstruct oral mucosa on the muscular flap with easier and faster way compared to conventional mucosal tissue engineering technique. Materials and methods: One day before the operation, oral mucosa(3mm in diameter) were taken and treated for extraction of oral keratinocytes according to the routine manner. The day of operation, oral keratinocytes were prepared in the laboratory and then moved to the operating theater. Autologous PRP was also prepared and then mixed with oral keratinocytes just before grafting on the prepared muscular flap. After keratinocyte-PRP complex was seated, then a sterilized rubber sheet was placed on the graft and the elevated skin flap was replaced and sutured. Biopsies were proceeded at 3, 5, 7, 14 and 21 days. Tissue samples were evaluated clinically, histologically, and immunohistochemically. Results: All of the oral keratinocyte-PRP complexes were successfully grafted on the recipient sites(100%). On 3 days after the operation, 1-2 continuous epithelial layer and many inflammatory cells were observed. On 5 days after the operation, increase of layers of keratinocyte was observed with less inflammatory response. Thickness of the layers was gradually increased from 7 to 21 days after the operation. Cytokeratin confirms epithelium in every specimen. Conclusions: Preconfluent graft of autogenous oral keratinocytes mixed with autogenous PRP have successfully reconstructed myo-mucosal flap. This technique could be a useful alternative for oral mucosal reconstruction in the near future.

Effective Analysis on the Mechanical Behavior of a Refrigerator using Equivalent Material Properties of Multi-layers (다중재질 접합구조의 등가물성을 이용한 효과적 냉장고 구조 변형 분석에 관한 연구)

  • Park, Jeong-Hyun;Lee, Dong-Kyu;Park, Sang-Hu;Park, Ki-Hong;Ha, Byeong-Kuk;Kim, Hyeong-Sik
    • Journal of the Korean Society for Precision Engineering
    • /
    • 제29권11호
    • /
    • pp.1228-1235
    • /
    • 2012
  • A refrigerator has many components which are made from diverse materials such as metal, polymer, plastic, and rubber. So, it generally requires much time and efforts to build up an analysis model in finite element analysis. In this work, to reduce the computational time and efforts a simplified modeling method was proposed for the analysis of a refrigerator. Occasionally, a stick-slip noise occurs in a refrigerator due to relative slip between shelf and inner-case. When we solve the problem by a FE analysis, we should model the structures with detail for considering the contact conditions; by this reason, too many efforts are consumed in the conventional analysis method. Through this work, we shows the concept of simplifying approach and a good agreement with the results of a real model analysis. And also, the evaluation of the proposed method and the application of contact analysis using the simplified model are discussed.