• Title/Summary/Keyword: Rotation movement

Search Result 625, Processing Time 0.033 seconds

Electromyographic Activities of Lower Leg Muscles During Static Balance Control in Normal Adults (정상성인에서 정적 균형 제어 시 다양한 조건에 따른 하퇴 근육 활성도의 특성)

  • Woo, Young-Keun;Park, Ji-Won;Choi, Jong-Duk;Hwang, Ji-Hye;Kim, Yun-Hee
    • Physical Therapy Korea
    • /
    • v.11 no.2
    • /
    • pp.35-45
    • /
    • 2004
  • The purpose of this study was to investigate the correlation and characteristics between electromyographic (EMG) activities of lower leg muscles and the posturographic assessment of static balance control in normal adults. Twenty-four young, healthy adults(12 males, 12 females) participated in the study. Center of pressure (COP) parameters were obtained using force platform as total path distance, total sway area, X mean frequency and Y mean frequency for 20 seconds in the following conditions: (1) comfortable standing with eyes opened or closed, (2) uncomfortable standing (feet together) with eyes opened or closed, (3) virtual moving surround delivered using Head mount display (HMD) with four different moving patterns. The virtual moving patterns consisted of close-far, superior-inferior tilting (pitch), right-left tilting (roll), and horizontal rotation (yaw) movements. Surface electromyographic activites were recorded on the tibialis anterior, peroneus longus, medial and lateral heads of gastrocnemius muscles under each condition. Correlation between the posturographic measures and EMG activities were evaluated. Total path distance and total sway area of COP were significantly increased during uncomfortable standing. EMG activity of tibialis anterior was significantly more during uncomfortable standing and virtual moving surround stimulation than during comfortable standing. Total path distance and sway area of COP during comfortable standing with closed eyes showed significant positive correlation with the EMG activities of the lateral head of gastrocnemius muscle. Total path distances and total sway area of COP during muscle. Total path distances and total sway area of COP during presentation of virtual moving surround also had significant positive correlations with EMG activities of the lateral head of gastrocnemius muscle under close-far movement.

  • PDF

TREATMENT OF ECTOPICALLY ERUPTING FIRST PERMANENT MOLAR IN CHRONIC MYELOGENOUS LEUKEMIA (전신 질환을 동반한 환아에서 나타난 제1대구치 이소맹출의 처치)

  • Kim, Hyun-Jung;Kim, Min-Jeong;Noh, Hong-Seok;Kim, Shin;Jeong, Tae-Sung
    • The Journal of Korea Assosiation for Disability and Oral Health
    • /
    • v.7 no.1
    • /
    • pp.33-37
    • /
    • 2011
  • The ectopic eruption is defined as abnormal eruption which gives to displacement of the teeth and abnormal root resorption of adjacent teeth. The prevalence of ectopic eruption is reported to vary 2~6%, most of them are in the maxilla. Etiologic factors include narrow maxilla, large maxillary teeth, inclined eruption path of the first molar, retruded position of the maxilla and hereditary factor. Irreversible ectopic eruption where the second primary molar is lost often causes mesial tipping and rotation of the permanent molar, unfavorable occlusion and space deficiency for the second premolar. Ectopically erupted teeth should be treated early to maintain normal development of the dentition, harmony of facial growth and occlusal support. The method of the treatment are classified as follows : appliances that is positioned at the contact point for unlocking and the distal movement, fixed appliance that is connected to more than one tooth, and occlusion guiding method after disking or extraction of the second deciduous molar. A case report of a patient with bilaterally ectopic eruption of maxilla and mandible first permanent molar was present. Also, the patient who had experienced the chronic myelogenous leukemia, show various dental developmental complications. The ectopic eruption was treated with a Halterman appliance that was a effective way of correcting of ectopic eruption of the permanent first molar.

Morphologic and positional assessment of temporomandibular joint disk in facial asymmetric patients by magnetic resonance imaging (자기 공명 영상을 이용한 안면비대칭환자의 측두하악관절원반의 형태와 위치에 관한 연구)

  • Zou, Bingshuang;Kim, Tae-Woo;Choi, Soon-Chul
    • The korean journal of orthodontics
    • /
    • v.35 no.5 s.112
    • /
    • pp.398-407
    • /
    • 2005
  • The present study was conducted to examine the morphometrics and function of the disk on both sides among patients with facial asymmetry (FA) and to elucidate plausible correlations between internal derangement (ID) and FA. The sample was composed of 10 males and 27 females with FA. The disk status of all subjects was evaluated by bilateral high resolution magnetic resonance scans in the sagittal (closed and open) and coronal (closed) planes. Five types of disk displacement were identified accordingly. The disk function was diagnosed as normal disk function, disk displacement with reduction, and disk displacement without reduction. The disk shape on sagittal MRI in closed position was classified as bi-concave, biplanar, funnel/hemiconvex, and deformed. The disk position, translation and rotation were also measured. The difference between the shifted side and non-shifted side was analyzed by statistical analysis. Approximately $70\%$ of the patients in the present study showed unilateral or bilateral ID. It was found that anterior disk displacements (ADD), especially rotational ADD, occurred more frequently in the shifted side, while normal disk position was observed mainly in the non-shifted side (p<0.01). The disk of the shifted side showed significantly deformed configuration and inferior-anterior disk position. However, the disk of the non-deviated side showed hyper-mobility during jaw opening movement. These results demonstrate that in FA patients, the disks status of the shifted side is different from that of the non-shifted side, a phenomenon that could be correlated to facial asymmetry.

Display of Irradiation Location of Ultrasonic Beauty Device Using AR Scheme (증강현실 기법을 이용한 초음파 미용기의 조사 위치 표시)

  • Kang, Moon-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.9
    • /
    • pp.25-31
    • /
    • 2020
  • In this study, for the safe use of a portable ultrasonic skin-beauty device, an android app was developed to show the irradiation locations of focused ultrasound to a user through augmented reality (AR) and enable stable self-surgery. The utility of the app was assessed through testing. While the user is making a facial treatment with the beauty device, the user's face and the ultrasonic irradiation location on the face are detected in real-time with a smart-phone camera. The irradiation location is then indicated on the face image and shown to the user so that excessive ultrasound is not irradiated to the same area during treatment. To this end, ML-Kit is used to detect the user's face landmarks in real-time, and they are compared with a reference face model to estimate the pose of the face, such as rotation and movement. After mounting a LED on the ultrasonic irradiation part of the device and operating the LED during irradiation, the LED light was searched to find the position of the ultrasonic irradiation on the smart-phone screen, and the irradiation position was registered and displayed on the face image based on the estimated face pose. Each task performed in the app was implemented through the thread and the timer, and all tasks were executed within 75 ms. The test results showed that the time taken to register and display 120 ultrasound irradiation positions was less than 25ms, and the display accuracy was within 20mm when the face did not rotate significantly.

Using the Arthroscopic Remplissage of Anterior Shoulder Instability with Hill-Sachs Lesion (전방 견관절 불안정성에서 Hill-sachs 병변의 관절경적 Remplissage)

  • Ko, Sang-Hun;Jung, Kwang-Hwan;Shin, Seung-Myeong;Park, Han-Chang
    • Clinics in Shoulder and Elbow
    • /
    • v.14 no.1
    • /
    • pp.53-58
    • /
    • 2011
  • Purpose: We evaluated the minimal 1 year follow-up results (shoulder stability and the clinical and functional results) for the Remplissage technique to fill a Hill-Sachs lesion. Materials and Methods: The subjects were 12 patients who could be followed up for more than 12 months after the "Remplissage" procedures in our hospital from December 2008 to November 2009. Their mean age was 27.9 years old and the mean follow-up was 19 months. The evaluations included the ROM, the ASES score, the KSSI score, the ROWE score and postoperative MRI. Results: On the postoperative functional evaluation after an average of 16 months, the ASES score improved from 50.8 preoperatively to 78.3 postoperatively, the KSSI score improved form 44.5 preoperatively to 81.0 postoperatively and the ROWE score improved from 40.2 preoperatively to 84.3 postoperatively. After an average 14 months for all the cases, the range of movement was nearly in the normal range, which is 178.6${\pm}$18.6 (165~180) degrees for forward flexion and 49.3${\pm}$10 (43~60) degrees for external rotation. Conclusion: For recurrent shoulder instability with a large Hill-Sachs lesion, the Remplissage technique has a good outcome after more than 1 year follow-up in terms of the shoulder stability and the clinical and functional results.

Paleomagnetic Study of the Daedong Group in the Choongnam Coal Field (충남탄전에 분포하는 대동층군에 대한 고지자기학적 연구)

  • Min, Kyung Duck;Um, Jeong-Gi;Kim, Dong Wook;Choi, Yong Hoon;Lee, Youn Soo;Nishimura, Susumu
    • Economic and Environmental Geology
    • /
    • v.25 no.1
    • /
    • pp.87-96
    • /
    • 1992
  • Paleomagnetic study on the sedimentary rocks in the Choongnam Coal Field has been carried out to determine the direction of declination and inclination of NRM and position of paleomagnetic pole, and to investigate the geotectonism and geomagnetic stratigraphy of the sedimentary rocks in the Daedong Group. As a result of paleomagnetic study, the study area can be divided tectonically into two blocks by Baegunsa fault, namely northwestern and southeastern blocks. Site mean declination and inclination of Baegunsa and Seoungjuri Formations in the northwestern block are $23.2^{\circ}$ and $54.9^{\circ}$, respectively. Those of Amisan, Jogyeri, Baegunsa and Seoungjuri Formations in the southeastern block show normal direction with declination and inclination of $-22.1^{\circ}$ and $11.2^{\circ}$, and reversed direction with those of $158.5^{\circ}$ and $-12.6^{\circ}$, respectively. Average paleomagnetic pole position in the northwestern block is located at $212.9^{\circ}E$ and $71.1^{\circ}N$, and that in the southeastern block at $345.7^{\circ}E$ and $53.3^{\circ}N$. This difference suggests relative rotation of about $45^{\circ}$ between two blocks. The paleolatitude of Daedong Group at the time of sedimentation is $5.6^{\circ}N$ much lower than present latitude of $37.7^{\circ}N$. Compared with worldwide Mesozoic paleomagnetic polarity stratigraphy, Amisan Formation is correlated with the lower boundary of Nuanetsi reversal zone in Graham interval, and Baegunsa and Seoungjuri Formations are correlated with just upper part of the upper boundary of Nuanetsi reversal zone, and their geologic ages are Late Triassic to Early Jurassic. The position of paleomagnetic pole acquired from Daedong Group in the study area is different from those in other places. This may be attributed to the different tectonic movement by Daebo Orogeny occurred after the deposition of Daedong Group.

  • PDF

Postural Control in Brain Damage Patients According to Moving Surround (뇌기능 장애 환자의 가상영상(Moving Sorround) 자극에 따른 자세 균형 제어)

  • 김연희;최종덕;이성범;김종윤;이석준;박찬희;김남균
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2002.11a
    • /
    • pp.233-244
    • /
    • 2002
  • The purpose of this study is to assess the ability of balance control in moving surround using head mount device and force platform and to examine the clinical usefulness of COP parameters. Fifteen patients with stroke and healthy persons were participated. COP parameters were obtained as total path distance, frequency of anterior-posterior and medial-lateral component by FFT analysis, weight-spectrum analysis in the two different conditions; (1) in comfortable standing with opened or closed eyes, (2) in virtual moving surround delivered using HMD to four different moving pattern. In virtual moving surround setting, moving pattern was composed of close-far, superior-inferior tilting(pitch), right-left tilting(roll) and horizontal rotation(yaw) movement. In all parameters, the reliebility of COP analysis system was significantly high. Also, the construct validity compared between fifteen patients with stroke and normal persons was excellent in virtual moving surround condition(p

  • PDF

Analysis of Radiation Field and Block Pattern for Optimal Size in Multileaf Collimator (치료조사면 및 블록 유형분석을 통한 적정 다엽 콜리메이터 규모에 관한 연구)

  • Ahn, Seoung-Do;Yang, Kwang-Mo;Yi, Byong-Yong;Choi, Eun-Kyong;Chang, Hye-Sook
    • Radiation Oncology Journal
    • /
    • v.12 no.2
    • /
    • pp.253-262
    • /
    • 1994
  • The patterns of the conventional radiation treatment fields and their shielding blocks are analysed to determine the optimal dimension of the MultiLeaf Collimator (MLC) which is considered as an essential tool for conformal therapy. Total 1109 radiation fields from 303 patients (203 from Asan Medical center, 50 from Baek Hosp and 50 from Hanyang Univ. Hosp.) were analysed for this study. Weighted case selection treatment site (from The Korean Society of Therapeutic Radiology 1993). Ninety one percent of total fields have shielding blocks. Y axis is defined as leaf movement direction and it is assumed that MLC is installed on the cranial-caudal direction. The length of X axis were distributed from 4cm to 40cm (less than 21cm for $95\%$ of cases), and Y axis from 5cm to 38cm (less than 22cm for $95\%$ of cases). The shielding blocks extended to less than 6cm from center of the field for $95\%$ of the cases. Start length for ninety five percent of block is less than 10cm for X axis and 11cm for Y axis. Seventy six percent of shielding blocks could be placed by either X or Y axis direction, $7.9\%$ only by Y axis, $5.1\%$ only by X axis and It is reasonable to install MLC for Y direction. Ninety five percent of patients can be treated with coplanar rotation therapy without changing the collimator angle. Eleven percent of cases of cases were impossible to replace with MLC. Futher study of shielding technique is needed for $11\%$ impossible cases. The treatment field dimension of MLC should be larger than $21cm{\times}22cm$. The MLC should be designed as a pair of 21 leaves with 1cm wide for an acceptable resolution and 17cm long to enable the leaf to overtravel at least 6cm from the treatment field center.

  • PDF

The Effects of Automatically Controlled Rotating Acupuncture on Thermal Allodynia in a Rat Model of Neuropathic Pain: Mediation by Endogenous Opioid System (신경병증성 통증에 대한 자동염전침의 진통효과 및 opioid 기전)

  • Park, Jung-Hyuk;Kim, Sun-Kwang;Na, Hyo-Suk;Moon, Hak-Jin;Min, Byung-Il;Kim, Ki-Hong;Rhim, Sung-Soo;Lee, Soon-Geul;Lee, Sang-Hoon
    • Journal of Acupuncture Research
    • /
    • v.23 no.5
    • /
    • pp.23-29
    • /
    • 2006
  • Objectives : The present study was conducted to evaluate the effects of automatically controlled rotating acupuncture (ACRA) on thermal allodynia in neuropathic pain rats, and to examine whether the endogenous opioid system mediates the effects of ACRA. Methods : For the neuropathic surgery, the right superior caudal trunk was resected at the level between S1 and S2 spinal nerves innervating the tail. Two weeks after the nerve injury, ACRA stimulation with 4 different stimulation conditions (i.e., angle and frequency of rotation: 90o+1Hz, 90o+1/4Hz, 360o+/1Hz, and 360o+1/4Hz) was delivered to the Zusanli (ST36) acupoint for 15 min. The behavioral signs of thermal allodynia were evaluated by the tail immersion test (i.e., immersing the tail in cold $(4^{\circ}C)$ or warm $(4^{\circ}C)$ water and measuring the latency to an abrupt tail movement) before and after the stimulation. In an additional set of experiments, we examined the effects of naloxone (opioid Results : ACRA stimulations under all of the conditions above significantly relieved thermal antagonist, 2mg/kg, i.p.) on the action of ACRA stimulation. allodynia. There is no difference in the anti-allodynic effects among the 4 stimulation conditions. In addition, the effect of ACRA on thermal allodynia was reversed by naloxone pretreatment. Conclusion : These results indicate that ACRA stimulations have relieving effects on thermal allodynia in neuropathic pain rats, irrespective of stimulation parameters, and that this is mediated by the endogenous opioid system.

  • PDF

Optimal Mechanism Design of In-pipe Cleaning Robot (관로 청소 로봇의 최적 설계)

  • Jung, C.D.;Chung, W.J.;Ahn, J.S.;Shin, G.S.;Kwon, S.J.
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.1
    • /
    • pp.123-129
    • /
    • 2012
  • Recently, interests on cleaning robots workable in pipes (termed as in-pipe cleaning robot) are increasing because Garbage Automatic Collection Facilities (i.e, GACF) are widely being installed in Seoul metropolitan area of Korea. So far research on in-pipe robot has been focused on inspection rather than cleaning. In GACF, when garbage is moving, the impurities which are stuck to the inner face of the pipe are removed (diameter: 300 mm or 400 mm). Thus, in this paper, by using TRIZ (Inventive Theory of Problem Solving in Russian abbreviation), an in-pipe cleaning robot of GACF with the 6-link sliding mechanism will be proposed, which can be adjusted to fit into the inner face of pipe using pneumatic pressure(not spring). The proposed in-pipe cleaning robot for GACF can have forward/backward movement itself as well as rotation of brush in cleaning. The robot body should have the limited size suitable for the smaller pipe with diameter of 300 mm. In addition, for the pipe with diameter of 400 mm, the links of robot should stretch to fit into the diameter of the pipe by using the sliding mechanism. Based on the conceptual design using TRIZ, we will set up the initial design of the robot in collaboration with a field engineer of Robot Valley, Inc. in Korea. For the optimal design of in-pipe cleaning robot, the maximum impulsive force of collision between the robot and the inner face of pipe is simulated by using RecurDyn(R) when the link of sliding mechanism is stretched to fit into the 400 mm diameter of the pipe. The stresses exerted on the 6 links of sliding mechanism by the maximum impulsive force will be simulated by using ANSYS$^{(R)}$ Workbench based on the Design Of Experiment(in short DOE). Finally the optimal dimensions including thicknesses of 4 links will be decided in order to have the best safety factor as 2 in this paper as well as having the minimum mass of 4 links. It will be verified that the optimal design of 4 links has the best safety factor close to 2 as well as having the minimum mass of 4 links, compared with the initial design performed by the expert of Robot Valley, Inc. In addition, the prototype of in-pipe cleaning robot will be stated with further research.