• Title/Summary/Keyword: Rotation movement

Search Result 623, Processing Time 0.03 seconds

Effect of adaptive movement on durability and working time of twisted file (Adaptive movement가 twisted file의 내구성과 작업 시간에 미치는 영향)

  • Lee, Sang-Ho;Park, So-Ra;Cho, Kyung-Mo;Park, Se-Hee;Kim, Jin-Woo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.35 no.1
    • /
    • pp.20-26
    • /
    • 2019
  • Purpose: Recently TF-adaptive movement is developed in order to increase the durability of TF files. The purpose of this study was to assess the effects of adaptive movement on durability and performance of twisted files. Materials and Methods: Resin blocks simulating artificial J-shape canals were used for this study. In TFC group, TF-adaptive ML-1 (25/.08 size) files were used to prepare the canals under continuous rotation 500 rpm/4.0 Ncm. In TFA group, TF-adaptive ML-1 (25/.08 size) files were used to prepare the canals under adaptive movement. After preparing each artificial canal, TF files were observed under dental microscope for assessing existence of unwinding, distortion, and fracture. If unwinding of flute was observed, the number of artificial canals until unwinding of flute occurs was recorded. Required time until instruments reach working length and distance of unwinded portion of files from D0 were measured. All test results were conducted by Mann-Whitney U test at a 0.05 level of significance. Results: No Ni-Ti instrument's separation was observed. Number of resin blocks until file unwinding happens and working time was significantly high in TFA group compared to TF group. Distance of distortion from D0 didn't show significant difference between TFA, TF groups. Conclusion: The number of resin blocks prepared until unwinding happens and working time were significantly high in TFA group. The location of unwinding showed no significant difference between 2 groups. Adaptive movement increased the number of canals prepared until unwinding occurs and working time of twisted files.

Kinematical Analysis of Basket with 1/2 Turn to Handstand on Parallel Bars (평행봉 Basket with 1/2 Turn to Handstand 기술 분석)

  • Back, Jin-Ho;Park, Jong-Chul;Lee, Yong-Sik
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.1
    • /
    • pp.165-174
    • /
    • 2007
  • The subject of this study was male apparatus gymnastics athlete who had scored high points doing basket with 1/2 turn on parallel bars. Then 3D motion analysis were used to calculate & analyse kinematic variables of Basket with 1/2 turn to Handstand. 1. The total average time spent for Basket with 1/2 turn took $2.16{\pm}.08sec$, at the downward upward phase took $.58{\pm}0.00sec$, $.23{\pm}.00sec$, at flight phase took $.28{\pm}.01sec$, at connected area phase took $.72{\pm}0.21sec$, at rotation area phase took $.35{\pm}.14sec$. To have a successful performance, there should be faster speed and velocity to rotate at the downward upward phase, then the upward velocity and height must be used adequately. Moreover, the speed must be faster at the flight connect phase to stabilize Center of Mass(CM) for the body, and must secure more time at the rotation area to have more stable performance. 2. After handstand on parallel bars while moving CM to right hand side, and It must be performed with big and magnificent performance with putting both hand's center to far away from the parallel bars. 3. Furthermore, CM must be moved fast from downwards to right hand side, and CM must be moved fast in vertical movement at upward and flight phase to avoid CM from moving back and forth, and left and right. 4. At downwards, the subject must rotate as bis as possible using hip-joint as wide as possible and at upwards, must put his body to vertical to have stable performance. While rotating or turning, it is better to do with bigger shoulder angle and have to make sure that trunk angle must be not scattered. To perform better and more positive in basket with 1/2 turn on parallel bars, the centrifugal force must be used big and fast at downward, and at upward and flight phase, downward movement must change to vertical movement as soon as possible while turning movement must happen at handstand position. Time spent must be shorten at connected area to stabilize CM and turning must be natural as possible while securing the necessary time of movement to well-balanced. Also, the body must be vertically closed from the ground.

Development of Diagnostic Questionnaires for Lumbar Movement System Impairment Syndromes (허리 부위 동태손상증후군의 진단을 위한 설문 문항 개발)

  • Kim, Jeong-Kyun;Kim, Hyunho;Kim, Dong-Won;Park, Jin-Sung;Park, Young-Bae;Park, Young-Jae
    • The Journal of Korean Medicine
    • /
    • v.37 no.1
    • /
    • pp.125-134
    • /
    • 2016
  • Objectives: The aim of this study is to develop diagnostic questionnaires for the lumbar movement system impairment syndrome. Methods: We had reviewed the previous study and literature and organized various checkable items for differential diagnosis of five different lumbar movement system impairment syndromes. Next, we selected items which can be developed as questionnaire items. Finally, we conducted face validity study with eight Korean medicine doctors and survey research for the importance score of the items with three experts. Results: We developed a diagnostic questionnaire as followings: 6 items for lumbar extension syndrome; 5 items for lumbar flexion syndrome; 6 items for lumbar rotation syndrome. With the 2 rounds of survey research, we could bridge the differences of the importance score of each items. Conclusions: Questionnaire for the diagnosis of movement system impairment syndrome was developed. With this questionnaire, objective diagnosis of lumbar movement system impairment syndrome can be expected. This tool may also be used for detecting sub-health status of musculoskeletal systems.

Coordination Pattern of Upper Limb of Sweep Shot Movement in Ice Hockey (아이스하키 스위프 샷(Sweep shot) 동작의 상지의 협응 형태)

  • Choi, Ji-Young;Lee, Eui-Lin
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.4
    • /
    • pp.169-179
    • /
    • 2007
  • The purpose of this study was to investigate the relations between the segments of the body and to qualitatively analyze coordination pattern of joints and segments during Sweep Shot movement in Ice Hockey, by utilizing coordination variables was angle vs. angle plots. By the utilization the three dimensional anatomical angle cinematography, the angles of individual joint and segment according to sweep shot in ice hockey. The subjects of this study were five professional ice hockey players. The reflective makers were attached on anatomical boundary line of body. For the movement analysis three dimensional cinematographical method(APAS) was used and for the calculation of the kinematic variables a self developed program was used with the LabVIEW 6.1 graphical programming(Johnson, 1999) program. By using Eular's equations the three dimensional anatomical Cardan angles of the joint and ice hockey stick were defined. The three dimensional anatomical angular displacement and coordination pattern of trunk and Upper limb(shoulder-elbow, elbow-wrist linked system) showed important role of sweep shot in ice hockey. As the result of this paper, for the successful movement of sweep shot in ice hockey, it is most important role of coordination pattern of trunk-shoulder, shoulder-elbow and elbow-wrist. specially turnk movememt as a proximal segment. Coordination pattern of Upper Limb(upperarm-forearm-hand) of Sweep Shot movement in Ice Hockey that utilizes coordination variables seems to be one of useful research direction to understand basic control mechanisms of Ice hockey sweep shooting linked system skill. this study result showed flexion-extension, adduction-abduction and internal-external rotation of trunk are important role of power and shooting direction coordination pattern of upper Limb of Sweep Shot movement in Ice Hockey.

Evaluation of Real-time Measurement Liver Tumor's Movement and $Synchrony^{TM}$ System's Accuracy of Radiosurgery using a Robot CyberKnife (로봇사이버나이프를 이용한 간 종양의 실시간 움직임 측정과 방사선수술 시 호흡추적장치의 정확성 평가)

  • Kim, Gha-Jung;Shim, Su-Jung;Kim, Jeong-Ho;Min, Chul-Kee;Chung, Weon-Kuu
    • Radiation Oncology Journal
    • /
    • v.26 no.4
    • /
    • pp.263-270
    • /
    • 2008
  • Purpose: This study aimed to quantitatively measure the movement of tumors in real-time and evaluate the treatment accuracy, during the treatment of a liver tumor patient, who underwent radiosurgery with a Synchrony Respiratory motion tracking system of a robot CyberKnife. Materials and Methods: The study subjects included 24 liver tumor patients who underwent CyberKnife treatment, which included 64 times of treatment with the Synchrony Respiratory motion tracking system ($Synchrony^{TM}$). The treatment involved inserting 4 to 6 acupuncture needles into the vicinity of the liver tumor in all the patients using ultrasonography as a guide. A treatment plan was set up using the CT images for treatment planning uses. The position of the acupuncture needle was identified for every treatment time by Digitally Reconstructed Radiography (DRR) prepared at the time of treatment planning and X-ray images photographed in real-time. Subsequent results were stored through a Motion Tracking System (MTS) using the Mtsmain.log treatment file. In this way, movement of the tumor was measured. Besides, the accuracy of radiosurgery using CyberKnife was evaluated by the correlation errors between the real-time positions of the acupuncture needles and the predicted coordinates. Results: The maximum and the average translational movement of the liver tumor were measured 23.5 mm and $13.9{\pm}5.5\;mm$, respectively from the superior to the inferior direction, 3.9 mm and $1.9{\pm}0.9mm$, respectively from left to right, and 8.3 mm and $4.9{\pm}1.9\;mm$, respectively from the anterior to the posterior direction. The maximum and the average rotational movement of the liver tumor were measured to be $3.3^{\circ}$ and $2.6{\pm}1.3^{\circ}$, respectively for X (Left-Right) axis rotation, $4.8^{\circ}$ and $2.3{\pm}1.0^{\circ}$, respectively for Y (Crania-Caudal) axis rotation, $3.9^{\circ}$ and $2.8{\pm}1.1^{\circ}$, respectively for Z (Anterior-Posterior) axis rotation. In addition, the average correlation error, which represents the treatment's accuracy was $1.1{\pm}0.7\;mm$. Conclusion: In this study real-time movement of a liver tumor during the radiosurgery could be verified quantitatively and the accuracy of the radiosurgery with the Synchrony Respiratory motion tracking system of robot could be evaluated. On this basis, the decision of treatment volume in radiosurgery or conventional radiotherapy and useful information on the movement of liver tumor are supposed to be provided.

A Study on Modeling of LD Movement and Measurement of Mass Center using Piezoelectric Element (압전소자를 이용한 레이저디스크 이동현상의 모델링과 질량중심의 위치결정에 관한 연구)

  • Song, Hwa-Seop;Hong, Jun-Hee
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.4 s.97
    • /
    • pp.213-219
    • /
    • 1999
  • Piezoelectric element is deformed by driving voltage pattern. We developed a device of moving LD(laser disk) to use the rapid deformation of piezoelectric element. If driving voltage is changed very rapidly, the difference of acceleration is accurred between spindle motor and LD. To move LD on turn table is attained by utilizing difference of acceleration. This paper describes theoretical and experimental results about the movement of LD and presents to measure the center of mass LD with unbalance force.

  • PDF

A Gait Analysis of the Women with Unilateral Posterior Rotated Ilium : A Clinical Case Report (편측 장골이 후방 회전된 여성의 보행분석 : 임상 사례보고)

  • Yang, Kyung-Hye
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.20 no.1
    • /
    • pp.27-34
    • /
    • 2014
  • Background: The purpose of this clinical case report is to confirm sacroiliac joint misalignment effects on the gait. Methods: A healthy women volunteered to participate in this case report. Measurement of the subject was performed two categories. One is physical examination of the pelvic by inspection, palpation, movement based tests and pain provocation tests. The other one is gait performance measurement by 3 dimentional motion analysis. Results: Diagnosis by physical examination of the subject was Lt. ilium posterior rotation. Pelvic, hip, knee and ankle in the 3 dimensional kinematic data, the most notable result was the ankle. Conclusion: To confirm the effect of the misalignment of the sacroiliac joint on the gait function, it must be evaluated by integrating the movement to the ankle from the lumbar.

A Study on Turning Gait for a Quadruped Walking Robot (사각 보행로보트의 회전 걸음새에 관한 연구)

  • ;;Zeungnam Bien
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.28B no.11
    • /
    • pp.886-896
    • /
    • 1991
  • In this paper a new turning gait is proposed for a quadruped walking robot. The proposed scheme makes it possible to control the translation and orientation of the walking robot simultaneously. At first the feasible leg sequences which can guarantee a positive longitudinal gait stability margin for each direction of movement are found. A method for finding the lifting time of each leg of a feasible leg sequince and selecting an optimal gait among feasible gaits is then suggested. The proposed gait can be appled to control the posture of walking robots and to generate an optimal gait for a desired movement of translation and rotation of the walking robot systematically.

  • PDF

Sensitivity to differences in the extent of neck retraction and rotation movements made with and without vision (시각 차단 유무에 따른 경부 후인과 회전의 운동 감각 비교)

  • Lee, Haejung;Nicholson, Leslie L.;Adams, Roger D.
    • PNF and Movement
    • /
    • v.2 no.1
    • /
    • pp.59-69
    • /
    • 2004
  • 목적 : 본 연구는 경부의 후인과 회전 운동 범위에 있어 운동 감각 역치의 차이를 비교하기 위해 수행되었다. 방법 : 본 연구의 대상자는 19명(10명 남자, 9명 여자 나이 19~30세 평균 23.2, 표준편차 3.3)이 참가하였다. 이 연구에서 운동 감각 역치는 편안히 앉은 자세에서 시각 차단시와 시각 허용시에, constant stimuli의 방법을 사용하여 반복 측정되었으며, 움직임을 수행 하는 과정에서 정지 상태를 유도하여 그 정지동작에서 두 동작의 차이를 평가하였다. 결과 : 본 연구의 결과 후인 운동 감각이 오른쪽 또는 왼쪽 회전 운동 감각 보다 더 민감하게 나타났다. 결론 : 중간 범위의 두 움직임간의 차이를 비교할 때 시각차단 유무는 각 운동 감각에 영향을 미치지 않았다.

  • PDF

Excavation and Building Damage Assessment - Fundamentals (지반굴착과 주변 구조물 손상평가 - 기본개념)

  • 유충식
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.03a
    • /
    • pp.263-270
    • /
    • 2002
  • During deep excavation, changes in the state of stress in the ground mass around the excavation and subsequent ground losses inevitably occur. These changes in the stress and ground losses are reflected on surrounding ground in the form of ground movements, which eventually Impose strains onto nearby structures through translation, rotation, distortion, and possibly damage. A substantial portion of the cost of deep excavations in urban environments is, therefore, devoted to prevent ground movements. Prediction of ground movements and assessment of the risk of damage to adjacent structures has become an essential part of the planning, design, and construction of a deep excavation project in the urban environments. This paper presents excavation-induced ground movement characteristics as well as important issues related to excavation-induced building damage assessment.

  • PDF