Browse > Article
http://dx.doi.org/10.14368/jdras.2019.35.1.20

Effect of adaptive movement on durability and working time of twisted file  

Lee, Sang-Ho (Department of Conservative Dentistry, College of Dentistry, Gangneung-Wonju National University School of Dentistry)
Park, So-Ra (Department of Conservative Dentistry, College of Dentistry, Gangneung-Wonju National University School of Dentistry)
Cho, Kyung-Mo (Department of Conservative Dentistry, College of Dentistry, Gangneung-Wonju National University School of Dentistry)
Park, Se-Hee (Department of Conservative Dentistry, College of Dentistry, Gangneung-Wonju National University School of Dentistry)
Kim, Jin-Woo (Department of Conservative Dentistry, College of Dentistry, Gangneung-Wonju National University School of Dentistry)
Publication Information
Journal of Dental Rehabilitation and Applied Science / v.35, no.1, 2019 , pp. 20-26 More about this Journal
Abstract
Purpose: Recently TF-adaptive movement is developed in order to increase the durability of TF files. The purpose of this study was to assess the effects of adaptive movement on durability and performance of twisted files. Materials and Methods: Resin blocks simulating artificial J-shape canals were used for this study. In TFC group, TF-adaptive ML-1 (25/.08 size) files were used to prepare the canals under continuous rotation 500 rpm/4.0 Ncm. In TFA group, TF-adaptive ML-1 (25/.08 size) files were used to prepare the canals under adaptive movement. After preparing each artificial canal, TF files were observed under dental microscope for assessing existence of unwinding, distortion, and fracture. If unwinding of flute was observed, the number of artificial canals until unwinding of flute occurs was recorded. Required time until instruments reach working length and distance of unwinded portion of files from D0 were measured. All test results were conducted by Mann-Whitney U test at a 0.05 level of significance. Results: No Ni-Ti instrument's separation was observed. Number of resin blocks until file unwinding happens and working time was significantly high in TFA group compared to TF group. Distance of distortion from D0 didn't show significant difference between TFA, TF groups. Conclusion: The number of resin blocks prepared until unwinding happens and working time were significantly high in TFA group. The location of unwinding showed no significant difference between 2 groups. Adaptive movement increased the number of canals prepared until unwinding occurs and working time of twisted files.
Keywords
NiTi file; twisted file; adaptive movement; unwinding;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Cheung GS, Liu CS. A retrospective study of endodontic treatment outcome between nickel-titanium rotary and stainless steel hand filing techniques. J Endod 2009;35:938-43.   DOI
2 Larsen CM, Watanabe I, Glickman GN, He J. Cyclic fatigue analysis of a new generation of nickel titanium rotary instruments. J Endod 2009;35:401-3.   DOI
3 Kim HC, Yum J, Hur B, Cheung GS. Cyclic fatigue and fracture characteristics of ground and twisted nickel-titanium rotary files. J Endod 2010;36:147-52.   DOI
4 Perez-Higueras JJ, Arias A, de la Macorra JC. Cyclic fatigue resistance of K3, K3XF, and twisted file nickel-titanium files under continuous rotation or reciprocating motion. J Endod 2013;39:1585-8.   DOI
5 Bouska J, Justman B, Williamson A, DeLong C, Qian F. Resistance to cyclic fatigue failure of a new endodontic rotary file. J Endod 2012;38:667-9.   DOI
6 Higuera O, Plotino G, Tocci L, Carrillo G, Gambarini G, Jaramillo DE. Cyclic fatigue resistance of 3 different nickel-titanium reciprocating instruments in artificial canals. J Endod 2015;41:913-5.   DOI
7 Ozyurek T. Cyclic Fatigue Resistance of Reciproc, WaveOne, and WaveOne Gold Nickel-Titanium Instruments. J Endod 2016;42:1536-9.   DOI
8 Pedulla E, Lo Savio F, Boninelli S, Plotino G, Grande NM, La Rosa G, Rapisarda E. Torsional and Cyclic Fatigue Resistance of a New Nickel-Titanium Instrument Manufactured by Electrical Discharge Machining. J Endod 2016;42:156-9.   DOI
9 Gambarini G, Piasecki L, Di Nardo D, Miccoli G, Di Giorgio G, Carneiro E, Al-Sudani D, Testarelli L. Incidence of Deformation and Fracture of Twisted File Adaptive Instruments after Repeated Clinical Use. J Oral Maxillofac Res 2016;7:e5.
10 Gambarini G, Plotino G, Piasecki L, Al-Sudani D, Testarelli L, Sannino G. Deformations and cyclic fatigue resistance of nickel-titanium instruments inside a sequence. Ann Stomatol (Roma) 2015;6:6-9.
11 Gambarini G. $TF^{TM}$ Adaptive: a novel approach to nickel-titanium instrumentation. X Endodontic Practice 2014;7:e2.
12 Reddy PJ, Kumar VS, Aravind K, Kumar HT, Vishal M B, Vizaikumar VN, Das R, Vamsilatha K. Canal Shaping with One Shape File and Twisted Files: A Comparative Study. J Clin Diagn Res 2014;8:1-3.   DOI
13 Schafer E, Diez C, Hoppe W, Tepel J. Roentgeno-graphic investigation of frequency and degree of canal curvatures in human permanent teeth. J Endod 2002;28:211-6.   DOI
14 Braga LC, Magalhaes RR, Nakagawa RK, Puente CG, Buono VT, Bahia MG. Physical and mechanical properties of twisted or ground nickel-titanium instruments. Int Endod J 2013;46:458-65.   DOI
15 Shen Y, Cheun GSP. Methods and models to study nickel-titanium instruments. Endodontic Topics 2013;29:18-41.   DOI
16 Gambarini G, Giansiracusa Rubini A, Sannino G, Di Giorgio G, Piasecki L, Al-Sudani D, Plotino G, Testarelli L. Cutting efficiency of nickel-titanium rotary and reciprocating instruments after prolonged use. Odontology 2016;104:77-81.   DOI