• 제목/요약/키워드: Rotation movement

검색결과 623건 처리시간 0.029초

Computational Study of the Magnetically Suspended Centrifugal Blood Pump (2nd Report: Pressure Fluctuation and Stability of Impeller Rotation for Different Volute Shapes)

  • Ogami, Yoshifumi;Matsuoka, Daisuke;Horie, Masaaki
    • International Journal of Fluid Machinery and Systems
    • /
    • 제4권4호
    • /
    • pp.375-386
    • /
    • 2011
  • The turbo-type blood pump studied in this paper has an impeller that is magnetically suspended in a double volute casing. The impeller rotates with minimal fluctuations caused by fluid and magnetic forces. In order to improve stability of the rotating impeller and to facilitate long-term use, a careful investigation of the pressure fluctuations and of the fluid force acting on the impeller is necessary. For this purpose, two models of the pump with different volute cross-sectional area are designed and studied with computational fluid dynamics software. The results show that the fluid force varies with the flow rate and shape of the volute, that the fluctuations of fluid force decrease with increasing flow rate and that the vibratory movement of the impeller is more efficiently suppressed in a narrow volute.

인공 무릎 관절의 3차원 운동 시뮬레이션 (Simulation of Three Dimensional Motion of the Knee Joint in Total Knee Arthroplasty)

  • 김기범;손권;문병영
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1310-1315
    • /
    • 2003
  • Severe osteoarthrosis of the knee joint often requires total knee arthroplasty (TKA) to yield adequate knee function. The knee joint with TKA is expected ideally to restore the characteristics, however, this is not necessarily true in the clinical cases. In this study the motions of the intact joint and the joint after TKA were investigated numerically using computer simulation. For active knee extension from 90 degrees of flexion to full extension, the intact knee joint exhibited anterior tibial translation near the full extension while it showed only rotation for other flexion angles. Physiologic external rotation of the tibia near full extension was also noted in the analytical model. The analysis of the tibial insert of three different shapes (flat, semicurved, and curved types) demonstrated characteristic rotational and sliding motions as well as different contact forces.

  • PDF

CNC 와이어 벤딩기 구동장치 개발 (Gear Train Development for CNC Wire Bending Machine)

  • 조현덕;최성종
    • 한국기계가공학회지
    • /
    • 제7권4호
    • /
    • pp.50-55
    • /
    • 2008
  • CNC wire bending machines are used in industries to make a type variety of wire products such as long links. The machines have a long arm device to rotate in order to remove forming errors by flexibility of wire. Generally, the machines which constructed servo motors in the arm have the rotating range of the arm under 360 degree because the servo motors connect with fixed control devices on frame by many cables. The rotating angle under 360 degree limits working speed and forming geometry. Therefore this study developed a gear train to drive a parts in arm and to be independent on arm rotation movement. The developed gear train can transfer four movements to four components in arm and is consists parallel of four pairs of satellite gear trains. This study constructed the CNC wire bending machine with the developed gear train and verified that the gear train could drive internal components independently on arm rotation.

  • PDF

HMD를 이용한 오디오 재생 기술에서 Latency의 영향 분석 (Effect on Audio Play Latency for Real-Time HMD-Based Headphone Listening)

  • 손상모;조현;김선민
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.141-145
    • /
    • 2014
  • A minimally appropriate time delay of audio data processing is investigated for rendering virtual sound source direction in real-time head-tracking environment under headphone listening. Less than 3.7 degree of angular mismatch should be maintained in order to keep desired sound source directions in virtually fixed while listeners are rotating their head in a horizontal plane. The angular mismatch is proportional to speed of head rotation and data processing delay. For 20 degree/s head rotation, which is a relatively slow head-movement case, less than total of 63ms data processing delay should be considered.

  • PDF

투명조각자기의 고속 FDM 3D 프린팅을 위한 가변 압출 기법 (An Adaptive Extrusion Control Technique for Faster FDM 3D Printing of Lithophanes)

  • 장승호;홍정모
    • 한국CDE학회논문집
    • /
    • 제22권2호
    • /
    • pp.190-201
    • /
    • 2017
  • This paper proposes how to solve a problem of FDM 3D printer's irregular output when changing volume of extrusion, adjusting movement speed of the printer's head and a way to fill new inner part. Existing slicers adjust directly to change the rotation speed of the stepper. In this method, the change of the extrusion area is delayed due to the gap between the stepper and the nozzle, so that precise control is difficult. We control the extrusion area adjusting the moving speed of the print head and making constantly the rotation speed of the stepper. Thus, the output time can be shortened by generating an efficient path having a short travel distance. For evaluation, we applied our method to lithophanes with detailed variation. Comparing existing methods, our method reduced output time at least 30%.

인공 무릎 관절의 3차원 운동 시뮬레이션 (Simulation of Three Dimensional Motion of the Knee Joint in Total Knee Arthroplasty)

  • 문병영;손권;김기범;서정탁
    • 한국정밀공학회지
    • /
    • 제21권9호
    • /
    • pp.188-195
    • /
    • 2004
  • Severe osteoarthrosis of the knee joint often requires total knee arthroplasty(TKA) to yield adequate knee function. The knee joint with TKA is expected ideally to restore the characteristics, however, this is not necessarily 1.ue in the clinical cases. In this study the motion of the intact joint and the joint after. TKA were investigated numerically using computer simulation. For active knee extension from 90 degrees of flexion to full extension, the intact knee joint exhibited anterior tibial translation near the full extension and it showed only rotation at other flexion angles. Physiologic external rotation of the tibia near full extension known as screw home movement was also noted in the analytical model. The analysis of the tibial insert of three different shapes (flat, semicurved, and curved types) demonstrated characteristic rotational and sliding motion as well as different contact forces.

Motion characteristics of a floating wave energy converter with wave activating body type

  • Kim, Sung-soo;Lee, Jae-chul;Kang, Donghoon;Lee, Soon-sup
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제11권1호
    • /
    • pp.244-255
    • /
    • 2019
  • Interest in renewable energy has been increasing in recent years for many reasons, and there have been many studies on new types of wave energy converters and mechanisms for them. However, in this paper, motion characteristics of a wave energy converter with a wave activating body type is studied with an experiment. In order to conduct the experiment, a simple wave activating body type's wave energy converter is proposed. Experimental variations consist of connection type and location. The connection type controls the rotation motions of structures, and the connection location controls the distance between structures. The movement of floating structures, such as rotation, velocity, and acceleration, is measured with a potentiometer and a motion capture camera. Using the recorded data, the motion characteristics derived from the experimental variations are investigated.

가속도계를 이용한 뇌졸중 환자의 보행 측정 (Walking Measures with a Tri-axial Accelerometer in Stroke Patients)

  • 오용섭;우영근
    • PNF and Movement
    • /
    • 제11권2호
    • /
    • pp.31-40
    • /
    • 2013
  • Purpose : The purpose of this study was to measure the center of mass in body with stroke patients using a tri-axial accelerometer during walking. Methods : Twenty-eight patients were recruited and divided into two groups for this study. To measure their walking ability, Timed Up & Go (TUG) test and Fucntioanl Gait Assessment (FGA) were conducted and acceleration at rotation of center of mass (COM) in body were measure for each group. Results : In the comparisons between the two groups, the TUG and FGA were not significant differences and acceleration at rotation of COM was not significant differences also. Conclusion : Our research results suggesting that the accelerometer may be used as a testing tool and ongoing assessment tool for stroke patients during effects of intervention in walking.

자하거 약침과 추나 요법으로 호전된 동결견 치험 3례 (Three Cases of Frozen Shoulder Treated with Hominis Placenta Pharmacopuncture and Chuna Manual Therapy)

  • 김민희;전수형
    • 대한한의학회지
    • /
    • 제44권1호
    • /
    • pp.117-127
    • /
    • 2023
  • Objectives: The purpose of this study is to report the effect of hominis placenta pharmacopuncture and chuna manual therapy in patients with frozen shoulder. Methods: Frozen shoulder was treated with hominis placenta pharmacopuncture and chuna manual therapy, and the overall shoulder pain was measured by visual analog scale (VAS), and the range of motion (ROM) of shoulder movement was evaluated by measuring passive abduction and external rotation and active hand to shoulder blade test. Results: After the treatment, overall shoulder pain was reduced, and ROM of passive abduction and external rotation was increased. Conclusions: The above results show that hominis placenta pharmacopuncture and chuna manual therapy can be used as an effective treatment for frozen shoulder.

공사 차량 충돌 경고 시스템 (Construction Vehicle Collision Warning System)

  • 신성윤;조광현;조승표;신광성
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2022년도 추계학술대회
    • /
    • pp.414-415
    • /
    • 2022
  • 본 논문에서는 작업/고속이동/케빈 회전 동작 중에 주변 360° 전방위에 있는 작업자와 장애물을 98% 이상 자동 인식하고 충돌경고를 안내하고 운전자에게 시야각을 확보해주는 충돌사고 예방 기술을 개발하고자 한다.

  • PDF