• Title/Summary/Keyword: Rotation motion

Search Result 1,119, Processing Time 0.028 seconds

Development of Physics Simulation for Augmented Reality Billiards Content (증강현실 당구 콘텐츠를 위한 물리 시뮬레이션 개발)

  • Kim, Hong-Jik;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.26 no.2
    • /
    • pp.150-159
    • /
    • 2022
  • In this paper, we propose a physics simulation for augmented reality (AR) billiards content. The characteristics of the physics simulation for the proposed AR billiards content are as follows. First, physical equations are derived by calculating the force and moment of inertia applied to the billiards ball to realize the motion of the billiards ball similar to the real one in the AR environment. Then, we determine the velocity and angular velocity of the virtual billiards ball associated with the rotation of the virtual billiards ball with respect to the impact point. Second, using some vectors such as incidnet vector, normal vector, reflection vector, the trajectory of the virtual billiards ball would be implement. these equations are applied to AR environment so that AR billiards content could be implement. This physics simulation allows users to feel like the real world using a virtual pool table and induce them to interact with the real environment. As a result of the experiment, the accuracy range between the path of the real billiards ball and the path of the virtual billiards ball was calculated to be 97.75% to 99.11%. Therefore, it was determined that the performance of the physics simulation for the AR billiards content proposed in this paper performs similarly to the path of the real billiards ball.

Modeling of a rockburst related to anomalously low friction effects in great depth

  • Zhan, J.W.;Jin, G.X.;Xu, C.S.;Yang, H.Q.;Liu, J.F.;Zhang, X.D.
    • Geomechanics and Engineering
    • /
    • v.29 no.2
    • /
    • pp.113-131
    • /
    • 2022
  • A rockburst is a common disaster in deep-tunnel excavation engineering, especially for high-geostress areas. An anomalously low friction effect is one of the most important inducements of rockbursts. To elucidate the correlation between an anomalously low friction effect and a rockburst, we establish a two-dimensional prediction model that considers the discontinuous structure of a rock mass. The degree of freedom of the rotation angle is introduced, thus the motion equations of the blocks under the influence of a transient disturbing force are acquired according to the interactions of the blocks. Based on the two-dimensional discontinuous block model of deep rock mass, a rockburst prediction model is established, and the initiation process of ultra-low friction rockburst is analyzed. In addition, the intensity of a rockburst, including the location, depth, area, and velocity of ejection fragments, can be determined quantitatively using the proposed prediction model. Then, through a specific example, the effects of geomechanical parameters such as the different principal stress ratios, the material properties, a dip of principal stress on the occurrence form and range of rockburst are analyzed. The results indicate that under dynamic disturbance, stress variation on the structural surface in a deep rock mass may directly give rise to a rockburst. The formation of rockburst is characterized by three stages: the appearance of cracks that result from the tension or compression failure of the deformation block, the transformation of strain energy of rock blocks to kinetic energy, and the ejection of some of the free blocks from the surrounding rock mass. Finally, the two-dimensional rockburst prediction model is applied to the construction drainage tunnel project of Jinping II hydropower station. Through the comparison with the field measured rockburst data and UDEC simulation results, it shows that the model in this paper is in good agreement with the actual working conditions, which verifies the accuracy of the model in this paper.

Effects of Rehabilitation Programs with Couching Exercise or Home Exercise on Shoulder Pain, Muscle Strength, and Daily Living Functions in Patients with Shoulder Impingement Syndrome (재활 프로그램을 적용한 코칭 운동과 자가 운동이 견관절 충돌증후군 환자의 견부통증, 근력 및 일상생활기능에 미치는 효과)

  • Kim, Yun-Young;Lim, Kyung-Choon
    • Journal of muscle and joint health
    • /
    • v.29 no.3
    • /
    • pp.141-150
    • /
    • 2022
  • Purpose: This study aimed to investigate the effects of rehabilitation programs with coaching exercise (CE) or home exercise (HE) on shoulder pain, muscle strength, and daily living functions (DLF) in patients with shoulder impingement syndrome. Methods: With quasi-experimental design, thirty patients (15 CE and 15 HE) participated in rehabilitation programs for 12 weeks. At first, data were collected for pain and DLF using questionnaires with testing muscle strength and range of motion. Then, subjects were allowed to receive training on rehabilitation with structured training materials. CE group visited sports center three times a week at P hospital and HE group did self-exercise at home. Data were analyzed using SPSS program. Results: After 12 weeks, both groups showed statistically significant changes in improving pain, muscle strength, and DLF. Compare to HE group, CE group showed a statistically significant improvement in shoulder pain (p=.021), muscle strength in internal rotation (p=.001) and abduction (p=.013) and DLF (p=.012). Conclusion: Rehabilitation programs for patients with shoulder impingement syndrome were effective to improve pain, muscle strength, and DLF. Although CE would bring the better effects, it is possible to apply HE through structured education to patients who are difficult to visit hospitals.

Development of Static Seal for a Liquid Rocket Engine (액체 로켓 엔진 스태틱 실 개발)

  • Jeon, Seong Min;Yoon, Suk-Hwan;Chung, Taegeum
    • Journal of Aerospace System Engineering
    • /
    • v.16 no.4
    • /
    • pp.53-59
    • /
    • 2022
  • Static seals are used to seal high temperature gas and cryogenic fluid under high pressure, at interfaces between liquid rocket engine components such as combustion chamber, turbopump, gas generator, valves, etc. As thermal expansion and contraction at assembly interfaces cause undesirable leakage under cryogenic and high temperature environments, static seals applied for sealing of joint interfaces without relative motion should be designed properly. The additional function of rotation at the sealing face is also required for static seals, when the spherical flange is used for improvement of assembly at misalignment interfaces. In this study, structural analysis and leak tightness test of simulating test rig for several important interfaces are performed, to verify structural integrity of static seals.

Radial Velocity and FWHM Spatial Distribution of [OIII] and H𝛽 Lines of the Type II Seyfert Galaxy Mrk 1 (제2형 세이퍼트 은하 Mrk 1의 [O III]와 H𝛽선의 시선 속도와 FWHM 공간 분포 연구)

  • Hyung, Siek;Lee, Seong-Jae;Cho, Ji Eun
    • Journal of the Korean earth science society
    • /
    • v.43 no.3
    • /
    • pp.351-366
    • /
    • 2022
  • We investigated the kinematic activity of the Type II Seyfert galaxy Mrk 1 based on H𝛽 and [O III] 5007 extracted from the MR 1 grism spectra observed with the OASIS attached to the CFHT 3.6 m telescope. The [O III] forbidden Gaussian line profiles exhibited asymmetric features with an excess of the blue component: (1) strongest at a distance of about 960 pc from the galaxy center, and (2) a wider line width of about ~900 km s-1 in the NS direction of the center. The velocity distributions in the spectral images showed blue or approaching flow motion in the NE zone, while receding in the SW zone, implying the counter-clockwise rotation. The radial velocity data showed that the center of the AGN region appears to be blocked by gas-dust approaching toward the Earth.

Mid-term outcomes of bony increased offset-reverse total shoulder arthroplasty in the Asian population

  • Tankshali, Kirtan;Suh, Dong-Whan;Ji, Jong-Hun;Kim, Chang-Yeon
    • Clinics in Shoulder and Elbow
    • /
    • v.24 no.3
    • /
    • pp.125-134
    • /
    • 2021
  • Background: To evaluate clinical and radiological outcomes of bony increased offset-reverse total shoulder arthroplasty (BIO-RSA) in the Asian population at mid-term follow-up. Methods: From June 2012 to August 2017 at a single center, 43 patients underwent BIO-RSA, and 38 patients with minimum 2 years follow-up were enrolled. We evaluated the clinical and radiological outcomes, and complications at the last follow-up. In addition, we divided these patients into notching and no-notching groups and compared the demographics, preoperative, and postoperative characteristics of patients. Results: Visual analogue scale, American Shoulder and Elbow Surgeons, University of California-Los Angeles Shoulder Scale, and Simple Shoulder Test scores improved significantly from preoperative (5.00, 3.93, 1.72, 3.94) to postoperative (1.72, 78.91, 28.34, 7.66) (p<0.05) outcomes. All range of motion except internal rotation improved significantly at the final follow-up (p<0.05), and the bone graft was well-incorporated with the native glenoid in all patients (100%). However, scapular notching was observed in 20 of 38 patients (53%). In the comparison between notching and no-notching groups (18 vs. 20 patients), there were no significant differences in demographics, radiological parameters, and clinical outcomes except acromion-greater tuberosity (AT) distance (p=0.003). Intraoperative complications included three metaphyseal fractures and one inferior screw malposition. Postoperative complications included ectopic ossification, scapular neck stress fracture, humeral stem relaxation, and late infection in one case each. Conclusions: BIO-RSA showed improved clinical outcomes at mid-term follow-up in Asian population. However, we observed higher scapular notching compared to the previous studies. In addition, adequate glenoid lateralization with appropriate humeral lengthening (AT distance) might reduce scapular notching.

Design of variable 4-bar linkage structure for adjustable driving angle (구동 각도 조절이 가능한 가변형 4절링크 설계)

  • Kim, Sang-Hyun
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.5
    • /
    • pp.591-596
    • /
    • 2022
  • Since 4-bar linkage widely used in various industrial fields has a fixed link length, it is inconvenient to add an independent link structure or control device to change the movement of output link. Therefore, this paper proposes a new concept of variable 4-bar linkage mechanism to selectively adjust the movement of the output link to fit desired situations, and applied to the commercial table fans, which is a representative product using a 4-bar linkage system. The optimal rotation angle steps for efficiency are determined experimentally and the appropriate lengths of linkage to fit each step are calculated analytically. Changes in the linkage length are implemented by the rotational motion using a grooved cylindrical cam and the feasibility of the proposed variable linkage mechanism is verified through fabrication and measurement. The presented variable link mechanism is expected to improve the efficiency of industrial robots and fuel valve systems.

On-line Magnetic Resonance Quality Evaluation Sensor

  • Kim, Seong-Min;McCarthy, Michael J.;Chen, Pictiaw;Zion, Boaz
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1996.06c
    • /
    • pp.314-324
    • /
    • 1996
  • A high speed NMR quality evaluation sensor was designed , constructed and tested . The device consists of an NMR spectrometer coupled to a conveyor system. The conveyor was run at speeds ranging from 0 to 250 mm/s. Spectral of avocado fruits and one-dimensional magnetic resonance images of pickled olives were acquired while the samples were moving on a conveyor belt mounted through a 20Tesla NMR magnet with a 20 mm diameter surface coil and a 150 mm diameter imaging coil respectively. Fro a magnetic resonance spectrum analysis, motion through variations in the magnetic field tends to narrow spectral line width just like using sample rotation in high resolution NMR to narrow spectral line width. Spectrum analysis was used to detect the dry weight of avocado fruits using the ratio oil and water resonance peaks. Good correlations maximum r=0.970@ 50 mm/s and minimum r=0.894@250mm/s ) between oil and water resonance peak ratio and dry weight of avocados were observed at speeds ra ging from0 to 250mm/s. For the application of magnetic resonance imaging (MRI) method, the projections were used to distinguish between pitted and non-pitted olives . Effect of fruit position in the coil was tested and coil degree effects were noticed when projects were generated under dynamic conditions. Various belt speeds (up to 250mm/s) were tested and detection results were compared to static measurements. Higher classification errors were occurred at dynamic conditions compared to errors while olives were at rest.

  • PDF

Automatic Feeding Bottle Washing Machine Usability Evaluation : Infant Product (자동 젖병 세척기 사용성평가 : 영유아 제품)

  • Park, Hye Jin;Kim, Jong Geun;Lee, Seok Jae
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.3
    • /
    • pp.507-514
    • /
    • 2022
  • This study is to compare and analyze the evaluation of cleaning cleanliness and usability according to the muscle activity and cleaning method in the wrist rotation motion when using a bottle washer for women with childbirth experience. To this end, when using an automatic bottle washer and a manual bottle washer, the muscle activity and cleaning cleanliness of the forearm muscles were quantitatively evaluated using equipment, and the effects of variables were analyzed and the following conclusions were obtained. First, it was found that the muscle activity was lower than that of the automatic baby bottle cleaner when using a manual bottle cleaner. Second, the cleanliness was judged to be the best in automatic washing (forward + reverse direction), followed by automatic washing (forward direction) and manual washing. Third, the usability evaluation of the use of the baby bottle washing machine showed higher satisfaction than that of the automatic baby bottle washing machine. Through these conclusions, this study can be used as basic data for product advancement in the future by proving the effectiveness of using an automatic bottle washer.

Radiologic and clinical outcomes of an arthroscopic bridging graft for irreparable rotator cuff tears with a modified Mason-Allen stitch using a plantaris tendon autograft: a case series with minimum 2-year outcomes

  • Hyun-Gyu Seok;Sam-Guk Park
    • Clinics in Shoulder and Elbow
    • /
    • v.26 no.4
    • /
    • pp.406-415
    • /
    • 2023
  • Background: Surgical management of a massive rotator cuff tear (RCT) is always challenging. This study describes the clinical and radiological outcomes of patients who underwent bridging grafts using a plantaris tendon for an irreparable RCT. Methods: Thirteen patients with a massive RCT were treated with arthroscopic interposition of a folded plantaris tendon autograft between June 2017 and January 2020. For clinical evaluation, a visual analog scale (VAS), American Shoulder and Elbow Surgeons (ASES) score, Disabilities of the Arm, Shoulder, and Hand (DASH) score, Constant-Murley score, and range of motion values were collected. For radiographic evaluation, standardized magnetic resonance imaging and ultrasonography were performed to check the integrity of the interposed tendon. Results: A statistically significant improvement at the final follow-up was evident in scores for the VAS (-3.0, P=0.003), ASES (24.9, P=0.002), D ASH (-20.6, P=0.001), and Constant-Murley values (14.2, P=0.010). In addition, significant improvement was shown in postoperative flexion (17.3°, P=0.026) and external rotation (27.7°, P<0.001). In postoperative radiologic evaluations, the interposed tendons were intact at the last examination in 12 of the 13 patients. No complications related to donor sites were reported. Conclusions: An arthroscopic bridging graft for irreparable RCTs using a modified Mason-Allen stitch and a plantaris autograft resulted in improved short-term radiological and clinical outcomes. Graft integrity was maintained for up to 2 years in most patients. Level of evidence: IV.