• 제목/요약/키워드: Rotation Sequence

검색결과 116건 처리시간 0.029초

Immuno Gold 표지법을 이용한 대장균내 Vibrio fluvialis MotX 단백질의 존재 부위 결정 (Detection of the Recombinant MotX Protein Vibrio fluvialis in Escherichia coli with Immuno-Gold Labeling Method)

  • 이종희;박제현;김선회;안선희;공인수
    • 한국수산과학회지
    • /
    • 제35권4호
    • /
    • pp.451-453
    • /
    • 2002
  • The rotation of the flagellar motor is powered by the electrochemical gradient of specific ions across the cytoplasmic membrane. Recently, the gents of the Na'-driven motor have been cloned from marine bacterium of Vibrio sp. and some of the motor proteins have been purified and characterized. Also, motx gene encoding a channel component of the sodium type flagellar motor was identified from Vibrio Huuiaiis (KTCC 2473). The amino acid sequence of MotX protein from V, Huvialis shared 90, 85, $85\%$ identity with V, cholerae, V. alginolyticus, V parahaemolyticus, respectively. We have studied the localization of the expressed MotX protein in Escherichia coli by immune-gold labeling of ultra-thin frozen section. Our observation of the expressed protein indicated that MotX protein could be existed as attachment to inner membrane in E. coli.

멜린 변환을 이용한 모자이크 이미지 생성 (Mosaics Image Generation based on Mellin Transform)

  • 이지현;양황규
    • 한국정보통신학회논문지
    • /
    • 제7권8호
    • /
    • pp.1785-1791
    • /
    • 2003
  • 본 논문은 파노라믹 이미지 생성을 위해 수평 이동 정보와 회전 정보가 있는 비디오 영상을 모자이킹 하는 방법을 제안한다. 멜린 변환 후 나타나는 이미지의 이동 정보와 회전 정보를 이용하여 각 이미지들을 접합하기 위한 투영 행렬을 계산한다. 그리고 모자이크 생성 시 나타날 수 있는 첫 이미지와 마지막 이미지의 누적 오차를 줄이고 전체적으로 접합하기 위해 각각 이미지 사이의 접합을 위한 투영행렬을 누적하여 적용함으로써 오차를 줄여 정확한 모자이크를 만들 수 있다. 지금까지 제안된 모자이킹 기법들은 노이즈에 지나치게 민감하거나 중복성 계산에 있어 시간이 지나치게 많이 소모되는 단점이 있었다. 또한 기존의 기법들은 카메라를 삼각대 위에 고정하여 수평 이동시켜 얻어진 영상만을 다루어, 이미지가 회전되었을 경우 정확한 모자이크 결과를 얻을 수 없었다. 따라서 본 논문에서는 멜린 변환에 기반한 투영행렬을 이용하여 노이즈에 덜 민감하고 이미지의 중복 정보와 이동 정보를 단 시간에 찾아 모자이크하는 방법을 제안한다.

단안영상에서 움직임 벡터를 이용한 영역의 깊이추정 (A Region Depth Estimation Algorithm using Motion Vector from Monocular Video Sequence)

  • 손정만;박영민;윤영우
    • 융합신호처리학회논문지
    • /
    • 제5권2호
    • /
    • pp.96-105
    • /
    • 2004
  • 2차원 이미지로부터 3차원 이미지 복원은 각 픽셀까지의 깊이 정보가 필요하고, 3차원 모델의 복원에 관한 일반적인 수작업은 많은 시간과 비용이 소모된다. 본 논문의 목표는 카메라가 이동하는 중에, 획득된 단안 영상에서 영역의 상대적인 깊이 정보를 추출하는 것이다. 카메라 이동에 의한 영상의 모든 점들의 움직임은 깊이 정보에 종속적이라는 사실에 기반을 두고 있다. 전역 탐색 기법을 사용하여 획득한 움직임 벡터에서 카메라 회전과 배율에 관해서 보상을 한다. 움직임 벡터를 분석하여 평균 깊이를 측정하고, 평균 깊이에 대한 각 영역의 상대적 깊이를 구하였다. 실험결과 영역의 상대적인 깊이는 인간이 인식하는 상대적인 깊이와 일치한다는 것을 보였다.

  • PDF

Evaluating anchorage loss in upper incisors during distalization of maxillary posterior teeth using clear aligners in adult patients: A prospective randomized study

  • Zehra Yurdakul;Nurver Karsli
    • 대한치과교정학회지
    • /
    • 제54권2호
    • /
    • pp.117-127
    • /
    • 2024
  • Objective: To evaluate the effect of clear aligner treatment and differential sequence distalization of maxillary posterior teeth on anchorage loss in the upper incisors (U1s). Methods: This study used lateral cephalometries and digital models of 12 patients treated with 33% sequential distalization (group 1, mean age: 22.9 ± 0.7 years, five males, seven females) and 12 treated with 50% sequential distalization (group 2, mean age: 25.83 ± 0.5 years, three males, nine females) acquired before and after distalization of upper second premolars (U5) and upper first molars (U6) and upper second molars (U7). The amount of distalization was determined as 2.5 mm in both the groups. Independent Samples t test was used to compare normally distributed parameters. Mann-Whitney U and Wilcoxon tests were used to compare parameters that were not normally distributed. Results: In both groups, the posterior teeth significantly moved by tipping distally and the U1s were displaced anteriorly. Increase in maxillary posterior transverse width (P < 0.001) and distopalatal rotation were observed in U5, U6, and U7 after distalization. It was also observed that U1 was significantly more proclined (1.82°; P < 0.001) and protruded (0.62 mm; P < 0.001), and the overjet (0.45 mm; P < 0.001) increased more in group 1 than in group 2. Conclusions: After sequential distalization of maxillary posterior teeth, more anchorage loss was observed in the anterior region in group 1 than in group 2.

자기공명 영상 및 3차원 영상을 이용한 견관절 관절낭-인대의 해부학적 연구. 역동학적 생체연구 (A Study of the Capsuloligamentous Anatomy of the Glenohumeral Joint Using Magnetic Resonance Imaging and Three-Dimensional Imaging. Dynamic In Vivo Study)

  • 박태수;최일용;주경빈;김선일;김준식;백두진
    • 대한관절경학회지
    • /
    • 제4권2호
    • /
    • pp.154-158
    • /
    • 2000
  • 목적 : 정상견관절의 각기 다른 위치에 따른 관절와 상완 인대들의 해부학적 구조 변화를 관찰하고자 하였다. 대상 및 방법 : 정상 견관절 9례에 대하여 생리식염수를 주입하고 외전 및 외 회전의 위치를 달리하여(각각 $0^{\circ}$$0^{\circ},\;45^{\circ}$$25^{\circ},\;90^{\circ}$ 및 최대 외 회전) 자기공명 영상을 각각 촬영하고 이를 이용하여 3차원 영상을 재구성한 후 관절와상완 인대 특히 중 및 하 관절와 상완 인대를 관찰하였다. 결과:. 중 관절와 상완 인대는 $0^{\circ}$ 외전 및 $0^{\circ}$ 외 회전시 상완골 두의 전면 적도를 중심으로 상하부에 걸쳐 이중 곡선 모양으로 비스듬히 위치하였다가, 외전 및 외 회전이 점차 증가하여 $45^{\circ}$$25^{\circ}$에 이르면 점차 상완골 두의 전면 적도 부근에 신장되어 거의 직선에 가까운 비스듬한 주행을 보였으며, $90^{\circ}$ 외전 및 최대 외회전시 상완골 두의 전면 적도의 상부 위치에 다시 곡선 모양을 보였다. 반면 하 관절와 상완 인대는 $0^{\circ}$ 외전 및 $0^{\circ}$ 외 회전시 상완골 두의 전면 하부에서 완만한 곡선 모양으로 위치하였으며, 외전 및 외회전이 증가함에 따라 상완골 두의 전면 적도 아래에 위치하면서 아래쪽으로 볼록한 곡선 모양을 보였다가, $90^{\circ}$ 외전 및 최대 외 회전시 상완골 두의 전면 하부에 거의 직선에 가깝도록 신장되어 비스듬히 위치하였다. 결론 : 견관절을 $45^{\circ}$ 외전 및 $25^{\circ}$ 외 회전 할 때와 $90^{\circ}$ 외전 및 최대 외 회전 시 중 관절와 상완 인대 및 하 관절와 상완 인대가 각각 신장되어 관절와 상완 관절의 중요한 정적 안정화 구조물로서 작용한다고 사료된다.

  • PDF

OPTICAL MULTI-CHANNEL INTENSITY INTERFEROMETRY - OR: HOW TO RESOLVE O-STARS IN THE MAGELLANIC CLOUDS

  • Trippe, Sascha;Kim, Jae-Young;Lee, Bangwon;Choi, Changsu;Oh, Junghwan;Lee, Taeseok;Yoon, Sung-Chul;Im, Myungshin;Park, Yong-Sun
    • 천문학회지
    • /
    • 제47권6호
    • /
    • pp.235-253
    • /
    • 2014
  • Intensity interferometry, based on the Hanbury Brown-Twiss effect, is a simple and inexpensive method for optical interferometry at microarcsecond angular resolutions; its use in astronomy was abandoned in the 1970s because of low sensitivity. Motivated by recent technical developments, we argue that the sensitivity of large modern intensity interferometers can be improved by factors up to approximately 25 000, corresponding to 11 photometric magnitudes, compared to the pioneering Narrabri Stellar Interferometer. This is made possible by (i) using avalanche photodiodes (APD) as light detectors, (ii) distributing the light received from the source over multiple independent spectral channels, and (iii) use of arrays composed of multiple large light collectors. Our approach permits the construction of large (with baselines ranging from few kilometers to intercontinental distances) optical interferometers at the cost of (very) long-baseline radio interferometers. Realistic intensity interferometer designs are able to achieve limiting R-band magnitudes as good as $m_R{\approx}14$, sufficient for spatially resolved observations of main-sequence O-type stars in the Magellanic Clouds. Multi-channel intensity interferometers can address a wide variety of science cases: (i) linear radii, effective temperatures, and luminosities of stars, via direct measurements of stellar angular sizes; (ii) mass-radius relationships of compact stellar remnants, via direct measurements of the angular sizes of white dwarfs; (iii) stellar rotation, via observations of rotation flattening and surface gravity darkening; (iv) stellar convection and the interaction of stellar photospheres and magnetic fields, via observations of dark and bright starspots; (v) the structure and evolution of multiple stars, via mapping of the companion stars and of accretion flows in interacting binaries; (vi) direct measurements of interstellar distances, derived from angular diameters of stars or via the interferometric Baade-Wesselink method; (vii) the physics of gas accretion onto supermassive black holes, via resolved observations of the central engines of luminous active galactic nuclei; and (viii) calibration of amplitude interferometers by providing a sample of calibrator stars.

유기농 답전윤환지 Fusarium thapsinum에 의한 수수 줄기썩음병 (Stalk Rot Caused by Fusarium thapsinum on Sorghum at Organic Paddy-upland Rotation System in Korea)

  • 김병련;한광섭;함수상;강영식;박인희;윤성탁
    • 식물병연구
    • /
    • 제22권4호
    • /
    • pp.293-296
    • /
    • 2016
  • 2016년 6월 말 경기도 안성시의 유기농 답전윤환 시험연구포장의 수수 5개 품종에서 줄기썩음병 증상이 관찰되었다. 초기 병징은 줄기의 표면에 적색의 병반이 형성되고 내부에 흑갈색의 반점이 존재하였다. 이후 진전되면 병반 표면에 연한 오렌지색의 포자가 형성되었다. 병원균을 분리하여 배양하면 균총은 백색에서 연한 오렌지색 또는 연노란색을 나타내고 소형분생포자는 $5-19{\times}2-4{\mu}m$의크기로 1-2개의격막을, 대형 분생포자는 $29-52{\times}3-4{\mu}m$로 4-6개의 격막을 갖고 있었다. 병원균의 분생포자 현탁액으로 수수유묘에 분무접종 3일 후 줄기에 진한 적색의 병반이 형성되었고 병의 진전에 따라 줄기가 고사하여 식물체는 쓰러졌다. 분리된 균주의 균학적 특징, 병원성, rDNA ITS 영역의 염기서열을 기초로 병원균은 F. thapsinum으로 동정되었고, 수수의 줄기썩음병으로 명명하였다.

다목적 방사선 조사장치 개발 및 선량분포특성 (The Development of a Multi-Purpose Irradiator and the Characteristic of Dose Distribution)

  • 이동훈;지영훈;이동한;김윤종;홍승홍
    • 전자공학회논문지SC
    • /
    • 제39권6호
    • /
    • pp.42-48
    • /
    • 2002
  • 다목적 방사선 조사장치의 설계, 제작 및 성능검사에 대해 기술하였다. 세슘-137을 사용한 다목적 방사선조사장치는 생물학에서 저선량 방사선에 대한 영향연구, 혹은 TLD(Thermo Luminescent dosimeter)의 교정을 위해 사용되어진다. 본 조사장치는 방사선 동위원소를 안전한곳에 저장하고 있다가 방사선조사시에만 조사실로 180도 회전하여 설정된 시간만큼 시료에 방사선 조사가 이루어 진 후, 사용이 끝나면 다시 차폐된 저장위치로 복귀하게된다. 제어시스템은 PLC 기반으로 구축하여 저선량율 조사장치의 시제품을 제작하였으며, 또한 컴퓨터를 통해 방사선 조사장치의 제어 및 세부 동작 상태 등을 실시간 검색, 원격제어 및 관리 할 수 있는 종합 관리 프로그램을 개발하였다. 조사실 내부 구성은 시료의 종류에 따라 최대 20RPM까지 다양하게 회전하면서 균일 조사될 수 있도록 조사실 및 챔버를 설계 제작하였으며, 조사실내 넣을 수 있는 조사체 최대 용량은 4.5리터이다. 조사실내의 방사선량의 분포도는 가프크로믹 필름을 사용하여 측정한 결과 2Ci 범위내에서 세슘-137의 경우 공기중에서 0.13cGy/min이었고 일반 물질과 등가인 물에서는 0.11cGy/min로 나타났으며, 오차는 약 ${\pm}$7%의 한도내에서 균일한 분포를 보였다. 또한 실제 누설선량은 조사실 밖 표면에서 최대 0.35mR/hr이였으며 1m 떨어진곳에서는 최대 0.03mR/hr로 허용치 이내였다.

Comparison between Conventional MR Arthrograhphy and Abduction and External Rotation MR Arthrography in Revealing Tears of the Antero-Inferior Glenoid Labrum

  • Jung-Ah Choi;Sang-il Suh;Baek Hyun Kim;Sang Hoon Cha;Myung Gyu Kim;Ki Yeol Lee;Chang Hee Lee
    • Korean Journal of Radiology
    • /
    • 제2권4호
    • /
    • pp.216-221
    • /
    • 2001
  • Objective: To compare, in terms of their demonstration of tears of the anterior glenoid labrum, oblique axial MR arthrography obtained with the patient's shoulder in the abduction and external rotation (ABER) position, with conventional axial MR arthrography obtained with the patient's arm in the neutral position. Materials and Methods: MR arthrography of the shoulder, including additional oblique axial sequences with the patient in the ABER position, was performed in 30 patients with a clinical history of recurrent anterior shoulder dislocation. The degree of anterior glenoid labral tear or defect was evaluated in both the conventional axial and the ABER position by two radiologists. Decisions were reached by consensus, and a three-point scale was used: grade 1=normal; grade 2=probable tear, diagnosed when subtle increased signal intensity in the labrum was apparent; grade 3=definite tear/defect, when a contrast material-filled gap between the labrum and the glenoid rim or deficient labrum was present. The scores for each imaging sequence were averaged and to compare conventional axial and ABER position scans, Student's t test was performed. Results: In 21 (70%) of 30 patients, the same degree of anterior instability was revealed by both imaging sequences. Eight (27%) had a lower grade in the axial position than in the ABER position, while one (3%) had a higher grade in the axial position. Three whose axial scan was grade 1 showed only equivocal evidence of tearing, but their ABER-position scan, in which a contrast material-filled gap between the labrum and the glenoid rim was present, was grade 3. The average grade was 2.5 (SD=0.73) for axial scans and 2.8 (SD=0.46) for the ABER position. The difference between axial and ABER-position scans was statistically significant (p<0.05). Conclusion: MR arthrography with the patient's shoulder in the ABER position is more efficient than conventional axial scanning in revealing the degree of tear or defect of the anterior glenoid labrum. When equivocal features are seen at conventional axial MR arthrography, oblique axial imaging in the ABER position is helpful.

  • PDF

QAM 시스템에서 SE-MMA 블라인드 적응 등화 알고리즘의 성능 (Performance of SE-MMA Blind Adaptive Equalization Algorithm in QAM System)

  • 임승각;강대수
    • 한국인터넷방송통신학회논문지
    • /
    • 제13권3호
    • /
    • pp.63-69
    • /
    • 2013
  • 본 논문은 대역폭 제한과 시분산 특성을 갖는 비선형 통신 채널에서 부호간 간섭을 경감시킬 수 있는 MMA(Multiple Modulus Algorithm) 블라인드 등화 알고리즘의 연산량을 더욱 간소화시킨 SE-MMA (Signed-Error MMA)의 성능에 관한 것이다. training sequence 없이도 채널에서 발생되는 부호간 간섭의 진폭과 위상 회전을 동시에 경감시킬 수 있는 MMA 알고리즘에서 등화기 출력 신호와 송신 신호의 통계적 특성인 Constant Modulus간의 오차 신호를 이용하지만, SE-MMA 알고리즘에서는 오차 신호의 극성만을 이용하게 되어 탭 계수의 갱신을 위한 연산량을 줄일 수 있으며, 이를 H/W 구현하는 경우 단순화할 수 있게 된다. SE-MMA 알고리즘의 성능을 기존의 MMA 알고리즘과 비교하기 위하여 컴퓨터 시뮬레이션을 수행하였으며, 이를 위해 수신측에서의 등화기 출력 신호인 복원된 신호 성상도, 수렴 성능을 나타내는 성능 지수인 MSE, MD (Maximum Distortion) 및 잔류 isi 특성 곡선과 SER을 사용하였다. 시뮬레이션 결과 수렴 속도에서는 SE-MMA가 MMA 보다 빠른 성능을 얻었지만, 정상 상태 이후 성능 지수의 양에서는 열악해짐을 확인하였다.