• Title/Summary/Keyword: Rotation Operation

Search Result 385, Processing Time 0.023 seconds

Development of the Rack-Bar Type Sluice Gate Applying the Hydrostatic Transmission (정유압식 래크바형 수문권양기의 개발)

  • Lee, Seong-Rae
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.7 no.4
    • /
    • pp.15-22
    • /
    • 2010
  • The typical hydraulic hoisting system of the rack-bar type sluice gate is composed of a hydraulic supply unit using an uni-directional pump, a direction control valve, a hydraulic motor, a counter balance valve, and flow control valves. Here, the hydrostatic transmission is applied to the hoisting system of rack-bar type sluice gate to simplify the operation of gate such that the upward and downward direction of gate is simply controlled by the direction of pump rotation. The new hydraulic hoisting system is composed of a bi-directional pump, a hydraulic motor, a counter balance valve, two check valves, two pilot-operated check valves, two relief valves and a shuttle valve. The characteristics of a suggested system are analyzed by computer simulations and experiments.

  • PDF

Development of the Rack-Bar Type Sluice Gate Applying the Hydrostatic Transmission (정유압식 래크바형 수문권양기의 개발)

  • Lee, Seong-Rae
    • 유공압시스템학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.86-92
    • /
    • 2010
  • The typical hydraulic hoisting system of the rack-bar type sluice gate is composed of a hydraulic supply unit using an uni-directional pump, a direction control valve, a hydraulic motor, a counter balance valve, and flow control valves. Here, the hydrostatic transmission is applied to the hoisting system of rack-bar type sluice gate to simplify the operation of gate such that the upward and downward direction of gate is simply controlled by the direction of pump rotation. The new hydraulic hoisting system is composed of a bi-directional pump, a hydraulic motor, a counter balance valve, two check valves, two pilot-operated check valves, two relief valves and a shuttle valve. The characteristics of a suggested system are analyzed by computer simulations and experiments.

  • PDF

A Stream Ciphering Method using a Chaotic System

  • Choi, Hyun-Jun;Seo, Young-Ho;Kim, Dong-Wook
    • Journal of information and communication convergence engineering
    • /
    • v.8 no.4
    • /
    • pp.433-436
    • /
    • 2010
  • In this paper, we presented a ciphering method whose target data is any kind of digital bit-stream. It uses a chaotic system as the main encrypting tool, MISR (Multi-Input Signature Register), and shift-and-rotation function, all of which are exclusive-ORed with the plaintext. Also, it incorporates a cipher text feedback mode such that part of the previously ciphered data is fed back to encrypt the current data. The encryption block size and the amount of feedback data are different at each ciphering operation. Experimental results with the image/video date showed that this method has enough speed and encryption effect with negligible latency time. Thus, we are expecting it to have various application areas that need high speed stream ciphering with high security level.

Development and Operation of Longitudinal Integrated Clerkship Programs in Overseas Medical Schools (외국 의과대학에서의 장기추적통합임상실습 개발과 운영사례)

  • Yeo, Sanghee
    • Korean Medical Education Review
    • /
    • v.20 no.1
    • /
    • pp.6-14
    • /
    • 2018
  • In recent years, Korean medical schools have shown a growing interest in the longitudinal integrated clerkship (LIC) as a means of improving clinical education. Some overseas medical schools have tried the LIC since the 1970s. In the 1990s, several universities in the United States, Canada, and Australia introduced LICs. A variety of studies have confirmed positive results of the LIC. Traditional block-rotation is a discipline-based, inpatient-centered practice. Instead, under the LIC system, a medical student responsible for a panel of longitudinal patients observes developments of their diseases, serving several departments simultaneously. Overseas medical schools have different LIC models depending on their affiliate hospitals' sizes and characteristics. The purpose of this study is to introduce LIC practices in Harvard Medical School and University of California San Francisco, which could be applied by Korean medical schools. This paper also aims to find out the strategies that have been able to help the two US medical schools implement the LIC successfully.

Design of an Electrodynamic Wheel for Transfer of Conductive Rod (전도성 환봉 이송용 동전기 차륜의 설계)

  • Park, Sung-Jun;Jung, Kwang-Suk
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.20 no.3
    • /
    • pp.251-256
    • /
    • 2011
  • Instead of multi-phase ac current, the magnetic field travels spatially through mechanical rotation of permanent magnets at the electrodynamic wheel (EDW). Traveling of magnetic field generally leads to a generation of inductive force in the traveling direction. In this paper, we suggest a spiral EDW to travel the magnetic field in the axial direction of the conductive rod. So, it is possible to levitate and transfer the rod through multi-axial forces by the spiral EDW. However, physical dimensions of permanent magnets constituting EDW influence relative ratios between three-axial forces generated on the rod. Therefore, the sensitivity analysis for design parameters is performed using FEM analysis. The stable operation is verified experimentally.

Numerical Investigation of Flowing Process for Regenerative Beat Exchanger of a Gas Turbine Engine (가스터빈 리제너레이토 내부유동에 관한 수치해석적 연구)

  • Kim Soo Yong;Kovalevsky Valeri P;Goldenberg Victor
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.8 no.4
    • /
    • pp.109-121
    • /
    • 2004
  • A distributed nonlinear mathematical model for investigation of regenerative heat exchangers of both a continuous and periodic operation is described in the paper. The non-iterative numerical integration scheme for conjugate unsteady heat exchange problem of one dimensional flows and two dimensional matrix wall conductivity is developed. Case study of a regenerative heat exchanger with a rotary ceramic matrix is presented. The range of optimum rotation rates of the regenerator providing the greatest calorific efficiency is determined.

Evolutionary Generation of the Motions for Cooperative Work between Humanoid and Mobile Robot (휴머노이드와 모바일 로봇의 협조작업을 위한 진화적 동작 생성)

  • Jang, Jae-Young;Seo, Ki-Sung
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.2
    • /
    • pp.107-113
    • /
    • 2010
  • In this paper, a prototype of cooperative work model for multi-robots system is introduced and the evolutionary approach is applied to generate the motions for the cooperative works of multi-robots system using genetic algorithm. The cooperative tasks can be performed by a humanoid robot and a mobile robot to deliver objects from shelves. Generation of the humanoid motions such as pick up, rotation, and place operation for the cooperative works are evolved. Modeling and computer simulation for the cooperative robots system are executed in Webots environments. Experimental results show the feasible and reasonable solutions for humanoid cooperative tasks are obtained.

A Two-Step Micromirror for Low Voltage Operation

  • Hwang Yong-Ha;Han Seungoh;Lee Byung-Kab;Kim Jae-Soon;Pak James Jungho
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.5C no.6
    • /
    • pp.270-275
    • /
    • 2005
  • In order for the application of the in-vivo endoscopic biopsy, a micromirror which can be driven at a low voltage is required. In this paper, a two-step micromirror composed of bottom electrodes, moving plate and top mirror plate is proposed. Because an electrical wiring of two plates are separated, they can be actuated separately. Therefore, an intermediate moving plate plays an important role in reducing the driving voltage in half. The designed device was fabricated by the surface micromachining. Maximum rotation angle of $6.3^{\circ}$ was obtained by applying DC 48V, while a conventional one-step mirror pulled down at DC 120V. The designed structure can be used in microphotonic applications requiring low driving voltage.

Design and Test of Vacuum Rotary Arc Gap Switch (Vacuum Rotary Arc Gap Switch의 설계 및 시험)

  • 서길수;황동원;이태호;황리호;김희진;이홍식;임근희
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.1
    • /
    • pp.19-24
    • /
    • 2003
  • Design and test results of a VRAG(Vacuum Rotary Arc Gap) switch were presented. To control the damage of electrodes caused by the vacuum arc, Lorentz's force by the radial magnetic field between spiral electrodes was used to rotate the vacuum uc. VRAG switch electrodes were made of the material of CuCr and OFHC. Gap distance between two spiral type electrodes for the rotation of the arc discharge is 8, 10, 12mm. In the cathode, one trigger electrode was inserted into each spiral wing. Normal operation of the VRAG switch was confirmed with 10.6[$mutextrm{s}$]of trigger delay and 2~3[$mutextrm{s}$] of the jitter time. The speed of the vacuum arc was measured to be 0.6 ~ 1[km/s] by a motion analyzer.

Development of an Anti-Seasickness Bed used in Vessel

  • Kim, Young-Bok;Jeong, Ji-Hyun
    • Journal of Power System Engineering
    • /
    • v.18 no.4
    • /
    • pp.112-116
    • /
    • 2014
  • Roll and pitching motions of a vessel can seriously degrade the performance of mechanical systems and the effectiveness of personnel. Many studies on roll stabilization and trimming control system design have focused on stabilizing the vessel through the use of fins, tanks, rudders and flaps. However the ultimate objective of such approaches must be to improve boarding sensitivity. This paper presents an anti-seasickness bed that consists of a rotator and bearing system that does not make use of electric power. The advantages of this system are its simple construction, usefulness, and safe operation. In this study, the rotation angles of the upper plate of a bed according to change weight of the rotator have been calculated to determine the stability. As a result, it can be concluded that proposed stabilizing bed can be of practical use in the field.