• Title/Summary/Keyword: Rotation Operation

Search Result 384, Processing Time 0.032 seconds

The Implementation of the Speed Measurement Board for the Reaction Wheel on the LEO Satellite using the T, M-Method (T-방식과 M-방식을 이용한 저궤도위성용 반작용 휠의 속도측정보드 설계)

  • Lee, Jae-Nyeung;Park, Sung-Hun;Heu, Su-Jin;Lee, Yun-Ki
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.40 no.9
    • /
    • pp.827-832
    • /
    • 2012
  • In this paper, we will design the speed measurement board of LEO Satellite's reaction wheel which has two speed measuring methods as M-Method type and T-Method type. therefore we can use the advantage of two methods. and we will verify the availability of design on the on-board computer at the real LEO Satellite(KOMPSAT-3). In the reaction wheels satellite that can change the satellite's attitude is one of the leading drivers by the rotational inertia of the motor will perform attitude control. Reaction methods for detecting wheel rotation speed generated during a certain period T internal reaction wheel tacho pulse counting M-Method to detect wheel speed and wheel tacho pulses are generated by measuring the time between the detection rate can be divided into T-Method. M-method is simple to implement and benefit measurement time is constant, but slow fall in the velocity measurement accuracy is a disadvantage. In contrast, the time between tacho pulses to measure the T-Method to measure the precise speed at low speed and to measure the time delay is small, has the advantage. However, this method also in the actual implementation and the complexity of the operation at different speeds depending on the speed of operation has the disadvantage.

3-D CT EVALUATION OF CONDYLE HEAD POSITION, MANDIBULAR WIDTH, AND MANDIBULAR ANGLE AFTER MANDIBULAR SETBACK SURGERY (3-D CT를 이용한 악교정수술후의 하악 과두 위치와 하악폭경 및 하악각의 평가)

  • Kim, Jae-Won;Lee, Dong-Hyun;Lee, Su-Youn;Kim, Jae-Hyun;Lee, Sang-Han
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.35 no.4
    • /
    • pp.229-239
    • /
    • 2009
  • The purpose of this study is to evaluate the change in condylar position, width, and angle before and after orthognathic surgery using 3-dimensional computed tomograph. Pre and posterative 3-D CT was taken on 38 patients and through axial, frontal, sagittal measurements and by 3-dimensional reconstruction, the changes in condylar postion, mandibular width and angle were analyzed and others such as the difference in gender, operation and fixation method, setback length and in relation with temporomandibular disorders were done together too. The results were as follows: The inward rotation of condyle in axial condylar angle, the forward movement of right condyle in sagittal anterior-posterior distance, the superior movement of both condyles in sagittal superior-inferior distance, the decrease in gonial angle, the increase in mandibular width, the decrease in distance between the axial coronoid process distance and the increase in the frontal intercondylar distance were statistically significant. There were no statistically significant changes in gender difference, however in the difference in operation method, change in the gonial angle was observed and there was more change in bilateral sagittal split osteotomy group compared to two-jaw surgery group. In the difference in fixation method, the decrease in axial coronoid process distance and the change in sagittal anterior-posterior distance were statistically significant. In the difference in setback, the increase in setback didn't relate directly with the increased change in condyle position. In the relation with temporomandibular disorder, changes in left axial condylar angle and axial coronoid process distance were statistically significant. Changes in condylar position could be observed after the orthognathic surgery but it doesn't seem to have much of a clinical importance. The orthognathic surgery is effective in decreasing the mandibular angle, and it is not related with the temporomandibular disorder.

An Efficient Data Block Replacement and Rearrangement Technique for Hybrid Hard Disk Drive (하이브리드 하드디스크를 위한 효율적인 데이터 블록 교체 및 재배치 기법)

  • Park, Kwang-Hee;Lee, Geun-Hyung;Kim, Deok-Hwan
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.16 no.1
    • /
    • pp.1-10
    • /
    • 2010
  • Recently heterogeneous storage system such as hybrid hard disk drive (H-HDD) combining flash memory and magnetic disk is launched, according as the read performance of NAND flash memory is enhanced as similar to that of hard disk drive (HDD) and the power consumption of NAND flash memory is reduced less than that of HDD. However, the read and write operations of NAND flash memory are slower than those of rotational disk. Besides, serious overheads are incurred on CPU and main memory in the case that intensive write requests to flash memory are repeatedly occurred. In this paper, we propose the Least Frequently Used-Hot scheme that replaces the data blocks whose reference frequency of read operation is low and update frequency of write operation is high, and the data flushing scheme that rearranges the data blocks into the multi-zone of the rotation disk. Experimental results show that the execution time of the proposed method is 38% faster than those of conventional LRU and LFU block replacement schemes in I/O performance aspect and the proposed method increases the life span of Non-Volatile Cache 40% higher than those of conventional LRU, LFU, FIFO block replacement schemes.

A Study of VR Interaction for Non-contact Hair Styling (비대면 헤어 스타일링 재현을 위한 VR 인터렉션 연구)

  • Park, Sungjun;Yoo, Sangwook;Chin, Seongah
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.2
    • /
    • pp.367-372
    • /
    • 2022
  • With the recent advent of the New Normal era, realistic technologies and non-contact technologies are receiving social attention. However, the hair styling field focuses on the direction of the hair itself, individual movements, and modeling, focusing on hair simulation. In order to create an improved practice environment and demand of the times, this study proposed a non-contact hair styling VR system. In the theoretical review, we studied the existing cases of hair cut research. Existing haircut-related research tend to be mainly focused on force-based feedback. Research on the interactive haircut work in the virtual environment as addressed in this paper has not been done yet. VR controllers capable of finger tracking the movements necessary for beauty enable selection, cutting, and rotation of beauty tools, and built a non-contact collaboration environment. As a result, we conducted two experiments for interactive hair cutting in VR. First, it is a haircut operation for synchronization using finger tracking and holding hook animation. We made position correction for accurate motion. Second, it is a real-time interactive cutting operation in a multi-user virtual collaboration environment. This made it possible for instructors and learners to communicate with each other through VR HMD built-in microphones and Photon Voice in non-contact situations.

The Study for EV Charging Infrastructure connected with Microgrid (마이크로그리드와 연계된 전기자동차 충전인프라에 관한 연구)

  • Hun Shim
    • Journal of Internet of Things and Convergence
    • /
    • v.10 no.1
    • /
    • pp.1-6
    • /
    • 2024
  • In order to increase the use of electric vehicles (EVs) and minimize grid strain, microgrid using renewable energy must take an important role. Microgrid may use fossil fuels such as small diesel power, but in many cases, they can be supplied with energy from renewable energy, which is an eco-friendly energy source. However, renewable energy such as solar and wind power have variable output characteristics. Therefore, in order to meet the charging and discharging energy demands of electric vehicles and at the same time supply load power stably, it is necessary to review the configuration of electric vehicle charging infrastructure that utilizes diesel power or electric vehicle-to-grid (V2G) as a parallel energy source in the microgrid. Against this background, this study modelized a microgrid that can stably supply power to loads using solar power, wind power, diesel power, and V2G. The proposed microgrid uses solar power and wind power generation as the primary supply energy source to respond to power demand, and determines the operation type of the load's electric vehicles and the rotation speed of the load synchronous machine to provide stable power from diesel power for insufficient generations. In order to verify the system performance of the proposed model, we studied the stable operation plan of the microgrid by simulating it with MATLAB /Simulink.

Arthroscopic Treatment using Bioabsorbable Knotless Anchor for Anterior Instability of Shoulder (관절경하 생체흡수형 Knotless Anchor를 이용한 견관절 전방 불안정성의 치료)

  • Lee, Yong-Jae;Lee, Tong-Joo;Lim, Kwang-Yul;Kim, Myung-Ku
    • Journal of the Korean Arthroscopy Society
    • /
    • v.8 no.2
    • /
    • pp.103-108
    • /
    • 2004
  • Purpose: This study reported the outcomes following the use of bioabsorbable knotless anchor in patients with anterior instability of shoulder. Methods: We studied fifteen cases with traumatic anterior shoulder instability underwent arthroscopic Bankart repair with bioabsorbable knotless suture anchor between January 2003 and June 2003. Among fifteen patients, fourteen were male and one was female, with a mean patient age of 24 years (range 16-42). The mean follow-up was 14 months (range 12-18 months). We compared with operation time of twenty cases of arthroscopic Bankart repair by the suture anchor technique between January 2002 and October 2002. Results: Neither recurrent dislocation nor subluxation was happened in postoperative follow-up. Mean score for functional evaluation by Rowe et al. was 89.4 and that for patient subjective satisfaction was 87,5. At last follow-up period, average shoulder range of motion for flexion and external rotation was 171$^{\circ}$ and 54$^{\circ}$ respectively. All patients were satisfied except three who had an apprehension at the follow up. During Bankart repair, it took an average of 25.5 minutes for one knot with the use of suture anchor technique whereas an average of 16.5 minutes for one knot with the use of bioabsorbable knotless anchor. Significantly, we saved operation time with the use of bioabsorbable knotless anchor (P<0.05).Conclusion: Repairing the Bankart lesion with the use of knotless anchor technique has the advantage of obtaining good capsular tensioning and saving operation time. And it is considered to be very successful in treating shoulder instability without recurrent dislocation or subluxation.

  • PDF

Treament of Sternal Dehiscence or Infection Using Muscle Flaps (근육편을 이용한 흉골열개 및 감염의 치료)

  • 최종범;이삼윤;박권재
    • Journal of Chest Surgery
    • /
    • v.34 no.11
    • /
    • pp.848-853
    • /
    • 2001
  • Background: Sternal infection or dehiscence after cardiac surgery through median sternotomy is rare. If suitable treatment is not performed for the complication, however, the mortality is high. For 12 patients with sternal dehiscence or infection, we performed wide excision of the infected and necrotic tissue and covered with muscle flap(s) to obliterate the mediastinal dead space. Material and method: Sternal infection or dehiscence occurred in 13 of patients who underwent cardiac surgery One patient, who died of cerebral infarction before the sternal complication was treated, was excluded in this study. The sternal wound complication occurred in 6 of patients with valve replacement and 6 of patients with coronary bypass surgery, respectively. Since 1991, 9 patients underwent definite surgical debridement and muscle transposition as soon as fever was controlled with closed irrigation and drainage. The necrotic tissue and bone was widely excised and the sternal dead space was eradicated with the single flap or the combined flaps of right pectoralis flap(turnover flap), left pectoralis flap(turnover flap or rotation-advancement flap), and right rectus muscle flap. Result : There was no mortality in 12 patients with coverage of muscle flap(s) for sternal infection or dehiscence The mean interval between the diagnosis of sternal complication and the myoplasty was 6.6$\pm$3.9 days. In 4 patients, one pectoralis muscle flap was used, and in 8 patients both pectoralis muscle flaps were used. For each 1 patient and 2 patients in each group, right rectus muscle flap was added. For the last 3 patients, a single pectoralis flap was used to eradicate the mediastinal dead space and the longer placement of the mediastinal drain catheter was needed. One patient, who had suffered from necrosis of left pectoralis flap(rotation-advancement flap) with subsequent chest wall abscess after coverage of both pectoralis flaps, was managed with reoperation using right rectum flap. Conclusion : Sternal dehiscence or infection after cardiac operation can be readily managed with wide excision of necrotic infected tissue(including bone) and muscle flap coverage after short-term irrigation of sternal wound. The sternal(mediastinal) dead space may be completely eradicated with right pectoralis major muscle flap alone.

  • PDF

Clinical and Radiographic Outcome of Shoulder Function after Unreamed Antegrade Intramedullary Nailing for Humerus Fracture: Ultrasonographic Evaluation for Rotator Cuff Integrity (비확공성 전향적 상완골 금속정 고정술후 견관절 기능에 대한 임상적 및 방사선학적 평가: 초음파를 이용한 회전근 개 추시관찰)

  • Baek, Seung-Hoon;Choi, Chang-Hyuk
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.6 no.1
    • /
    • pp.1-9
    • /
    • 2013
  • Purpose: The purpose is to perform objective evaluation for rotator cuff using ultrasonography and validate factors influencing cuff integrity as well as efficacy of follow-up ultrasonography after unreamed antegrade intramedullary nailing for humerus fracture. Materials and Methods: Seventeen patients with an average age of $55.7{\pm}18.6$ years underwent antegrade intramedullary nailing for humerus fracture and follow-up ultrasonography of shoulder joint. Mean follow-up period was $43.5{\pm}32.2$ months. Intraoperative evaluation for preoperative cuff tear was performed, of which four cuffs were repaired by single row repair technique. Clinical evaluation included visual analogue scale (VAS), range of motion, Korean Shoulder Scoring System (KSS) and American Shoulder and Elbow Society (ASES) score. Ultrasonographic evaluation was performed on cuff integrity and protrusion of proximal nail tip as well. Radiographic evaluation included time to union, protrusion of proximal nail tip and migration of proximal interlocking screw which could affect shoulder joint function. Results: Mean VAS at last follow-up was $1.65{\pm}1.84$ points. Range of motion showed forward flexion of $137.0{\pm}33.5^{\circ}$, external rotation of $43.5{\pm}12.7^{\circ}$ and internal rotation of $16.4{\pm}2.0^{\circ}$ while KSS score and ASES score were $79.6{\pm}20.7$ and $83.7{\pm}17.0$ points, respectively. Bone union was demonstrated in all cases and average time to union was $3.4{\pm}1.3$ months. Migration of proximal interlocking screw was shown in 6 cases (35%). On ultrasonographic evaluation, there were normal in 8 (47%), weaving in 4 (24%), partial tear in 5 cases (29%), but no complete tear. Protrusion of proximal nail tip was demonstrated in 8 cases (47%) on plain radiographs whereas in 11 cases (65%) on ultrasonography and was associated with increasing age (p=0.038). Ultrasonographic weaving and partial tear was associated with protrusion of proximal nail tip (p=006), but not with repair of preoperative tear (p>0.05). Conclusion: Because weaving and partial tear on ultrasonography originated from protrusion of proximal nail tip, careful insertion of nail and meticulous repair of cuff during operation lead to stable fixation with satisfactory recovery of shoulder function follow-up ultrasonography can be a useful tool for evaluating protrusion of nail tip and rotator cuff tear, of which diagnosis is difficult on plain X-ray after antegrade intramedullary nailing for humerus fracture.

  • PDF

An Experimental Study on Characteristics of Cooler by Oil Pressure for Decreasing Heat Load in Cold Storage (냉동창고 내 열부하 감소를 위한 유압 구동식 냉각기의 특성에 관한 실험적 연구)

  • Kim, Jae-Dol
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.8
    • /
    • pp.1116-1122
    • /
    • 2009
  • As a result of this study, we reached the following conclusions. With appropriate setting of oil pressure and flow rate, it operated same rotation speed with existing cooler by electrical transmission. In initial operation, a temperature of a cold storage is lower rapidly. As an internal temperature of a cold storage is lower, a decreasing rate of temperature is lower. As a result of comparing the both type, the cooler of oil pressure type showed the following results. The decreasing rate of temperature was more faster and shorter operating time was more shorter than existing cooler of electric type. The actual case of a cold storage, the cooler of oil pressure type can prevent quality deterioration and decrease power consumption. As an internal temperature of a cold storage is lower, power consumption increased rapidly, the oil pressure type showed lower power consumption. COP of two of these types decreased continuously as the internal temperature of a cold storage being reach setting temperature, and that of oil pressure type showed higher amount about 25%. As a setting temperature is lower, the number of refrigerator's operating times are less and operating time is longer, so power consumption is increased in the maintenance of a cold storage's internal temperature, power consumption of hydraulic type showed lower amount about 21~25% in two of these types.

Performance of SE-MMA Blind Adaptive Equalization Algorithm in QAM System (QAM 시스템에서 SE-MMA 블라인드 적응 등화 알고리즘의 성능)

  • Lim, Seung-Gag;Kang, Dae-Soo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.13 no.3
    • /
    • pp.63-69
    • /
    • 2013
  • This paper related with the performance of SE-MMA (Signed-Error MMA) that is the reduction of computational operation number in algorithm than MMA blind eualization algorithm which are possible to elimination of intersymbol interferance in the band limited and time dispersive nonlinear communication channel. In MMA algorithm which are possible to reduction of amplitude and phase rotation by intersymbol interference that is occurred in channel without using the training sequence, it uses the error signal that is the difference of the equalizer output and constant modulus, the statisticlly characteristic of transmitted signal. But in SE-MMA, it uses the polarity of the error signal, then it is possible to reduce the updating the tap coefficient and to simplify the H/W implementation. The computer simulation were performed in order to compare the performance of SE-MMA and conventional MMA algorithm. For this, the recovered signal constellation that is the output of the equalizer, the convergence performance by MSE, MD (maximum distortion) and residual isi characteristic learning curve, SER were used. As a result of simulation, the SE-MMA has more fast convergence speed than the MMA. But in the other index after reaching the seady state, it gives more worst performance values in the used index.