• Title/Summary/Keyword: Rotation Effect

Search Result 1,344, Processing Time 0.028 seconds

Effect of Crop Rotation System on Soil Chemical Properties and Ginseng Root Rot after Harvesting Ginseng (인삼 연작지에서 윤작물 작부체계가 토양화학성 및 인삼뿌리썩음병 발생에 미치는 영향)

  • Lee, Sung Woo;Lee, Seung Ho;Park, Kyung Hoon;Jang, In Bok;Jin, Mei Lan;Seo, Moon Won
    • Korean Journal of Medicinal Crop Science
    • /
    • v.25 no.4
    • /
    • pp.244-251
    • /
    • 2017
  • Background: The application of crop rotation systems may reduce the occurrence of soil-borne diseases by releasing allelochemicals and by subsequent microbial decomposition. Methods and Results: For reduction of ginseng root rot by the crop rotation system, after harvesting 6-year-old ginseng, fresh ginseng was grown along with continuous cultivation of sweet potato, peanut, and bellflower. Growth of 2-year-old ginseng was significantly inhibited in the continuous cultivation than in the first cultivation. Sweet potato, peanut and bellflower cultivations assisted in obtaining normal yields of ginseng in the first year after the harvest of 6-year-old ginseng. Salt concentration, potassium and sodium contents were gradually decreased, and, organic matter was gradually increased through cirp rotation. Phosphate, calcium and magnesium contents were not altered. The density of the root rot fungus was gradually decreased by the increase in crop rotation; however it was decreased distinctly in the first year compared to the second and third year. The severity of root rot disease tended to decrease gradually by the increase of crop rotation. Conclusions: Short-term crop rotation for three years promoted the growth of ginseng, however root rot infection was not inhibited significantly, although it was somewhat effective in lowering the density of the root rot pathogen.

The Comparative Study on Effect of Jungsongouhyul Phamacopuncture and Electroacupuncture in Patients with Acute Traumatic Shoulder Pain (급성 외상성 어깨 통증 환자에 대한 중성어혈약침과 전침의 효과에 관한 비교 연구)

  • Ji, Min Jung;Lim, Seong Chul;Kim, Jae Soo;Lee, Hyun Jong;Lee, Yun Kyu
    • Journal of Acupuncture Research
    • /
    • v.31 no.4
    • /
    • pp.205-211
    • /
    • 2014
  • Objectives : The purpose of this study is to report the effect of Jungsongouhyul phamacopuncture and electroacupuncture on patients with acute traumatic shoulder pain. Methods : The patients with acute traumatic shoulder pain were diagnosed by blood stasis and divided two groups. One group was treated byJungsongouhyul phamacopuncture. The other group was treated by electroacupuncture. Each group was treated 3 times a week for 2 weeks. The results were measured by visual analog scale(VAS), range of abduction and internal rotation. Results : Two groups had no significant differences before treatment. Jungsongouhyul phamacopuncture group had effects on VAS, range of abduction and internal rotation significantly. Electroacupuncture group also had effects on VAS, range of abduction and internal rotation significantly. But there was no significant differences between two groups. Conclusions : Jungsongouhyul phamacopuncture and electroacupuncture have effect on patients with acute traumatic shoulder pain significantly.

Faraday Rotation of the Hoya FR5 and FR4 Glasses at Cryogenic Temperature (저온에서 Hoya FR5 및 FR4 유리의 Faraday 회전)

  • 이현곤;원영희;이경수
    • Korean Journal of Optics and Photonics
    • /
    • v.6 no.4
    • /
    • pp.352-358
    • /
    • 1995
  • Measurements of the Faraday rotation and magnetization of terbium-doped Hoya FR5 glass and cerium-doped Hoya FR4 glass have been made as a function of temperature T in the range 4.2 K -10 K and of magnetic field H of up to 80 kG at the $Ar^+$ laser wavelength of 514.5nm. The saturations of magnetization and Faraday rotation above H/T> $5kG.K^{-1}$ can be analyzed by the quantum theory of paramagnetism. Calculated parameters show that the large Verdet constant of $Ce^{3+}$ glass is due to the effective $4f\rightarrow5d$ electric dipole transition effect and that of $Tb^{3+}$ glass is due to the magnetization effect.effect.

  • PDF

VARIATION IN THE GROWTH PATTERN OF THE FACE: A LONGITUDINAL COMPUTERIZED RECTILINEAR CEPHALOMETRIC STUDY (안면골의 성장회전에 관한 연구)

  • Kim, Il-Bong;Sung, Jae-Hyun;Chung, Kyu-Rhim
    • The korean journal of orthodontics
    • /
    • v.15 no.1
    • /
    • pp.123-140
    • /
    • 1985
  • Variation in the facial pattern and effect of the rotational jaw growth on the facial proportion were studied in serial cephalometric radiographs of 40 Korean children (25 boys, 15 girls) ranging in age from 6 to 13 years. According to Y-axis (N-S-Gn) growth change during the 7 years of period, the subject who had exhibited 'wave-like' manner of Y-axis growth change within ${\pm}\;2^{\circ}$ was classified to the Parallelwise group and the subject who had exhibited Y-axis increase more than $+2^{\circ}$ was classified to the Clockwise rotation group and the subject who had exhibited Y-axis decrease more than $-2^{\circ}$ was classified to the Counterclockwise rotation group. For the comparison of each group, a total of 22 morphologic variables were employed and the data were analyzed by means of computer morphometrics and statistical methods. On the basis of the finding of this study, the following trends were established. 1. The Parallelwise group was $75\%$, the Clockwise rotation group was $12.5\%$ and the Counter-clockwise rotation group was $12.5\%$. 2. The growth pattern of cranial base was related to the rotation of mandible. 9. Maxillary prognathism was occured in the Counterclockwise rotation group and the rotation of palatal plane was occured in the Clockwise rotation group. 4. Mandibular prognathism was occured in the Parallelwise and the Counterclockwise rotation groups, especially in the Counterclockwise rotation group. 5. The degree of maxillo-mandibular divergency was constant in the Clockwise rotation group but decreased in the Counterclockwise rotation and the Parallelwise groups, especially in the Counterclockwise group. 6. There were no differences in the size of the anterior upper facial height (N-ANS) and the posterior lower facial height ((Go-Me)-PNS) but there were differences in the size of the anterior lower facial height (ANS-Me) and the posterior upper facial height ((S-N)-PNS) between each group. 7. The growth increment and the size of the facial depth was not related to the growth pattern of the face but the growth increment and the size of the facial height was related to the growth pattern of the face. 8. Proportional change due to the facial growth rotation was concentrated in the anterior lower face. 9. The most apparent difference between each group was happened in the size of the posterior cranial base (S-Ba) and the facial length (S-Gn).

  • PDF

Self Reversal Effect of the High-pressured Diatomic Sulfur in the Electrodeless Sulfur Discharge Lamp (무전극 황방전등에서 고압 이원자 황($S_2$)의 자체 역전 효과)

  • Chu, Jang-Hee;Goo, Sun-Geun;Park, Ki-Jun;Yi, Young-Woo
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.11
    • /
    • pp.609-615
    • /
    • 2000
  • A prototype electrodeless sulfur lamp was developed and investigated the spectroscopic characteristics. The emission spectra of $S_2$ in the microwave-discharged eletrodeless sulfur lamp (ESL) were studied at various input power. The emission spectra of the ESL shift to longer wavelength with increasing of the input power. We have shown that this is due to the self reversal effect in the high pressure gas discharge. We also show that the self reversal effect increases as the rotation of the discharged bulb. The spectral distribution of the ESL shifts about 45 nm toward visible region from UV region due to the rotation of the lamp bulb.

  • PDF

Effect of 8 Direction Incline and Rotation Exercise on Pain and Dynamic Balance in the Patients with Chronic Low Back Pain (8방향 경사와 회전 운동이 만성요통환자의 통증과 동적균형에 미치는 영향)

  • Goo, Bong-Oh;Park, Min-Chull;Song, Yoo-Yik;Cho, Ye-Rim
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.9
    • /
    • pp.285-292
    • /
    • 2010
  • The purpose of this study is to investigate the effect of 8 direction incline and rotation exercise on pain and dynamic balance in the patients with chronic low back pain(CLBP). 20 patients who were diagnosed with CLBP were included for the study. 10 patients(experimental group) were treated by modality{Hot Pack(H/P), Transcutaneous Electric Nerve Stimulation(TENS), Ultra Sound(U/S)} and then performed 8 direction incline and rotation exercise. The other 10 patients(control group) were only treated by modality. The therapeutic intervention was taken three times a week for 6 weeks. Dynamic balance was assessed by Star Excursion Balance Test(SEBT) and pain was assessed by Visual Analog Scale(VAS). VAS scores of both groups were decreased. However, the experimental group was more significantly decreased than the control group. The dynamic balance of both groups was significantly increased in anterior, posterior, medial, lateral direction. But experimental group was more significantly increased than the control group. In conclusion, 8 direction incline and rotation exercise was effective on pain and dynamic balance in CLPB.

The Effect of Spanwise Flow and Wing Rotation on the Aerodynamic Characteristics in Flapping Motion (날개 길이방향 유동과 날개 회전이 날개짓 운동의 공기역학적 특성에 미치는 효과)

  • Oh, Hyun-Taek;Choi, Hang-Cheol;Chung, Jin-Taek;Kim, Kwang-Ho
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.35 no.9
    • /
    • pp.753-760
    • /
    • 2007
  • In a 3-D flapping motion, the spanwise flow is generated while the wing is moved on the stroke plane. And at the end of each stroke, the rotational circulation is generated due to a wing rotation. In this study, to evaluate the effect of spanwise flow and wing rotation on the aerodynamic characteristics in 3-D flap 753ping motion, a 3-D flapping motion was compared with a 2-D translating motion. In each flapping motion, the aerodynamic forces were measured with respect to the angles of attack and Reynolds number. The aerodynamic forces generated by 2-D translating motion were higher than those generated by 3-D flapping motion. While the lift of 3-D flapping motion was increased until the angle of attack $60^{\circ}$ at mid-stroke, the lift generated by 2-D translating motion was decreased above the angle of attack 40° at mid stroke. Also, at the end of each stroke, the aerodynamic forces were increased rapidly due to wing rotation.

Discharge Characteristics of Rotating Orifices with Length-to-Diameter Ratios and Inlet Corner Radii (길이 대 직경 비와 입구 모서리 반경에 따른 회전 오리피스의 송출 특성)

  • Ha, Kyoung-Pyo;Kang, Se-Won;Kauh, Sang-Ken
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.7
    • /
    • pp.957-966
    • /
    • 2000
  • The effect of rotation on the discharge coefficient of orifices with various length-to-diameter ratios and two different inlet corner radii was studied. Length-to-diameter ratios of the orifices range from 0.2 to 10, while the inlet shapes are square edged, or round edges of radius-to-diameter ratio of 0.5. From the experiment, we found that rotational discharge coefficient and Rotation number, when based on ideal exit velocity of the orifice considering momentum transfer from the rotor, describe the effect of rotation very well. In this study, the discharge coefficients of rotating orifices are shown to behave similar to those of the well-known non-rotating orifices. For both rotating and non-rotating orifices, the discharge coefficients increase with the length-to-diameter ratio until a maximum is reached. The flow reattachments in the relatively short orifices are responsible for the increase. The coefficient then decreases with the length-to-diameter ratio due to the friction loss along the orifice bore. The length-to-diameter ratio that yields maximum discharge coefficient, however, increases with the Rotation number because the increased flow-approaching angle requires larger length-to-diameter ratio for complete reattachment. The length-to-diameter ratio for complete reattachment is shorter for round edged orifices than that of square edged orifices by about a unit length-to-diameter ratio.

A Rotation Resistant Logo Embedding Watermark on Frequency Domain (회전 변환에 강인한 주파수 영역 로고 삽입 워터마크 방법)

  • Lee, In-Jung;Lee, Hyoung;Min, Joon-Young
    • Proceedings of the Korea Society of Information Technology Applications Conference
    • /
    • 2006.06a
    • /
    • pp.730-736
    • /
    • 2006
  • In this paper, we propose a rotation resistant robust logo embedding watermarking technique. Geometric manipulations make the detection process very complex and difficult. Watermark embedding ill the normalized image directly suffers from smoothing effect due to the interpolation during the image normalization. This can be avoided by estimating the transform parameters using image normalization technique, instead of embedding in the normalized image. Conventional rotation resistant schemes that use full frame transform. In this paper, we adopt $8{\times}8$ block DCT and calculate masking using a spatio-frequency localization of the $8{\times}8$ block DCT coefficients. Experimental results show that the proposed algorithm is robust against rotation process.

  • PDF

Design and Analysis of a Wrist Rotation Module Prototype for Partial Hand Amputees: Effects on Upper Limb Movement (부분 손 절단자를 위한 프로토 타입의 손목 회전 모듈 디자인 제안과 상지 움직임의 영향 분석)

  • Seoyoung Choi;Wonwoo Cho;Keehoon Kim
    • The Journal of Korea Robotics Society
    • /
    • v.18 no.4
    • /
    • pp.367-375
    • /
    • 2023
  • Most partial hand amputees experience limited wrist movement, which hinders the efficient functioning of upper limb, affecting hand-to-use coordination and the usability of the prosthetic hand. This limitation can lead to secondary musculoskeletal issues due to repetitive compensatory movement patterns. However, current partial hand prosthetic lack rotational wrist movement due to challenges in accommodating various hand shapes and limited space. In our study, we proposed a prosthetic hand with a wrist rotation module for partial hand amputees, aiming to reduce compensatory movement. To validate the proposed wrist rotation module, we conducted motion analysis during reach-to-grasp task. Furthermore, during the Jebsen-Taylor hand function test, we evaluated both the effect on upper limb movement and the usability of the prosthetic hand, comparing configurations with and without the wrist rotation module. The results showed that the prosthetic hand equipped with rotational wrist movements reduces compensatory movements and promotes efficient upper limb movement patterns. This finding highlights the value of incorporating a wrist rotation module in prosthetic hands to improve upper limb movement for partial hand amputees.