• Title/Summary/Keyword: Ropeless elevator

Search Result 7, Processing Time 0.031 seconds

A Study on the Design of PM Exited Transverse Flux Linear Motor for Ropeless Elevator (Ropeless 승강기용 영구자석여자 횡자속 선형전동기 설계에 관한 연구)

  • Gang, Do-Hyeon;Bang, Deok-Je;Kim, Jong-Mu;Jeong, Yeon-Ho;Kim, Mun-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.3
    • /
    • pp.145-151
    • /
    • 2000
  • The topological investigations regarding magnetic circuit geometry and winding form of the transverse flux machine have brought up a variety of constructable arrangements with different features for several types of application[1, 2]. Here with, a novel PM-exited linear motor with inner mover, based on the transverse flux configuration leads to a considerable increase in power density for moving part. In this study we designed PM-exited transverse flux linear motor for ropeless elevator, whose output power density is higher and weight is lighter than conventional linear synchronous motors. When the designed motor in this study is applied to ropeless elevator, it is possible to increase power density more than 400% comparing with PM exited linear synchronous motor. The result of this study can be utilized for ropeless elevator or gearless direct linear moving system with high output[3].

  • PDF

Study of Drive Control System for Ropeless Elevator (로프리스 엘리베이터 구동제어기 개발연구)

  • Kim, Youn-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.8
    • /
    • pp.3634-3641
    • /
    • 2012
  • This paper introduced a previous study which suggest ways to improve problems of drive control system of Ropeless Elevator when developing prior to commercialization of Ropeless Elevator. In particular, this study also manufactured motor, linear speed sensor and the miniature systems to study the implementation of the Ropeless Elevator drive. This study examined the problem of conventional PI controller through the speed control test and focused on the advanced controller based on disturbance observer for Ropeless Elevator drive. The results of this study confirmed the feasibility of the Ropeless Elevator and showed the satisfactory results of drive control techniques. This study also extracted many more problems that still need to be improved in the future for commercializing such as the sensor, high-performance controller, precision structures, safety devices and so on.

A Preceding Study on Drive System of the Ropeless Elevator (로프리스 엘리베이터 구동시스템 선행연구)

  • Kim, Youn-Hyun;Kim, Sol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.1
    • /
    • pp.402-410
    • /
    • 2014
  • This paper suggests a preceding study to introduce implementing problems and improving direction when commercializing a ropeless elevator. In this study, the implementation of the study of pilot systems in order to produce the ropeless elevator and also build a linear velocity sensor, this system is applied to the speed control experiment was investigated through testing. Speed control test is carried out in all track including a curved section. This study verified the feasibility of the ropeless elevator and its drive controller is good enough to be accepted. This study also extracted many more problems that still need to be improved in the future for commercializing such as the sensor, high-performance controller, precision structures, safety devices, efficiency improvements and so on.

A Selection of PM-LSM Topology Structure for Ropeless Elevator System (Ropeless 엘리베이터 시스템용 영구자석 선형동기전동기 구조에 관한 연구)

  • Jin, Sang-Min;Chung, Koon-Seok;Zhu, Yu-Wu;Cho, Yun-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.973.1_974.1
    • /
    • 2009
  • One of the most important technical improvement required for ropeless elevator system to become practical is the improvements in overall system efficiency. Moreover, the predominant drawback of permanent magnet (PM) linear synchronous motor (LSM) is large detent force. Therefore, for the given volume the selection of high power density PM-LSM with low detent force is very imperative. In this paper, we will investigate the characteristics of thrust and detent force of PM-LSM under different motor topology structure. Finally, the long stator double-sided iron core type PM-LSM with fractional slot winding is the best choice for the ropeless elevator system.

  • PDF

The Ropeless Elevator: New Transportation System for High-rise Buildings (and Beyond)

  • Belmonte, Martina;Trabucco, Dario
    • International Journal of High-Rise Buildings
    • /
    • v.10 no.1
    • /
    • pp.55-62
    • /
    • 2021
  • The paper reports the result of a 2-year long research conducted by CTBUH on the design possibilities enabled by the Ropeless and Multidirectional elevator systems, investigating how such a significant innovation (or better to say revolution) in the vertical transportation could affect tall buildings first and cities then. The purpose of the study is to prefigure the adoption of ropeless and multidirectional cabins for tall buildings mobility, with the aim to overcome the evolutionary bottleneck of the high-rise building type due to the exclusively vertical direction of transport, which limited, over the years, the design possibilities in terms of height, shape and relations with the surrounding environment. CTBUH research team, together with professionals in the field and supporting academic advisors, developed a series of design considerations on plan organizations, dispatching alternatives and on the integration of horizontal direction in the circulation, with the aim of anticipating potential and criticality arising from the application of ropeless and multidirectional systems.

Design of PM Excited Transverse Flux Linear Motor of Inner Mover Type

  • Kang Do-Hyun;Ahn Jong-Bo;Kim Ji-Won;Chang Jung-Hwan;Jung Soo-Jin
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.5B no.2
    • /
    • pp.137-141
    • /
    • 2005
  • A transverse flux, PM-exited linear motor (TFM-LM) with inner mover was designed and built. Its output power density is higher and its weight is lower than those of the conventional PM exited linear synchronous motors (PM LSM). To obtain the maximum thrust force under the given volume, the thrust force density with respect to the ratio of the slot width and the length of pole pitch is analyzed by the 3-dimension finite element method (FEM). Finally, calculated static thrust forces was compared with the experimental values. The calculated and measured performance of the transverse flux, PM-exited linear motor with inner mover revealed great potential for system improvements by reducing the mass of the linear motor. For examples, when this motor was applied to a ropeless elevator, it was possible to increase the power density by more than 400% over the conventional PM-LSM. The results of this study recommend this type of motor for the ropeless elevator or gearless direct linear driving system.

Detent Force Minimization of Permanent Magnet Linear Synchronous Motor for Ropeless Elevator System Using Response Surface Method (반응표면법을 이용한 로프리스 엘리베이터용 영구자석 선형 동기전동기의 디텐트력 최소화)

  • Lee, Sang-Gun;Chung, Koon-Seok;Zhu, Yu-Wu;Kim, Do-Sun;Cho, Yun-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.812_813
    • /
    • 2009
  • 본 논문에서 로프리스 엘리베이터용 영구자석형(PM) 선형동기전동기(LSM)의 디텐트력을 저감하기 위하여 반응표면법(RSM)을 이용한 디텐트력의 최소화 설계 방법을 제안하였다. RSM을 이용하여 정수 슬롯형과 분수 슬롯형 PM-LSM의 설계변수를 추론하고 유한요소법(FEM)으로 디텐트력을 구하였다. 반응표면법과 유한요소법의 해석결과를 토대로 분수 슬롯형 PM-LSM이 주어진 체적의 엘리베이터 시스템에 적합한 형상임을 입증한다.

  • PDF