• Title/Summary/Keyword: Root mean square of power

Search Result 245, Processing Time 0.03 seconds

Stochastic micro-vibration response characteristics of a sandwich plate with MR visco-elastomer core and mass

  • Ying, Z.G.;Ni, Y.Q.;Duan, Y.F.
    • Smart Structures and Systems
    • /
    • v.16 no.1
    • /
    • pp.141-162
    • /
    • 2015
  • The magneto-rheological visco-elastomer (MRVE) is used as a smart core to control the stochastic micro-vibration of a sandwich plate with supported mass. The micro-vibration response of the sandwich plate with MRVE core and supported mass under stochastic support motion excitations is studied and compared to evaluate the vibration suppression capability. The effects of the supported mass and localized magnetic field on the stochastic micro-vibration response of the MRVE sandwich plate are taken into account. The dynamic characteristics of the MRVE core in micro-vibration are described by a non-homogeneous complex modulus dependent on vibration frequency and controllable by applied magnetic fields. The partial differential equations for the coupled transverse and longitudinal motions of the MRVE sandwich plate with supported mass are derived from the dynamic equilibrium, constitutive and geometric relations. The simplified ordinary differential equations are obtained for the transverse vibration of the MRVE sandwich plate under localized magnetic fields. A frequency-domain solution method for the stochastic micro-vibration response of sandwich plates with supported mass is developed based on the Galerkin method and random vibration theory. The expressions of frequency-response functions, response power spectral densities and root-mean-square velocity responses of the plate in terms of the one-third octave frequency band are obtained for micro-vibration evaluation. Finally, numerical results are given to illustrate the large response reduction capacity of the MRVE sandwich plate with supported mass under stochastic support motion excitations, and the influences of MRVE parameters, supported mass and localized magnetic field placement on the micro-vibration response.

Configuration of a 16-Element Array Antenna Design to Improve Signal Detection Performances (신호탐지 정확도를 높이기 위해 최적 배열형상을 고려한 16소자 배열안테나 설계)

  • Jang, Doyoung;Yoo, Sungjun;Wang, Jinchun;Lee, Jun-Yong;Choo, Hosung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.30 no.6
    • /
    • pp.438-444
    • /
    • 2019
  • In this paper, we proposed a 16-element array antenna design to improve signal detection performances. The array antenna characteristics, such as mutual coupling, pattern deviation, and half power beamwidth of the active element, were examined to obtain an optimal spacing between individual elements. The single element of the array antenna consists of an indirect feed using L-shaped feed and shorted radiating patch to achieve a broadband operation. Root mean square(RMS) errors based on the incident angle of the signal were calculated to verify the signal detection performance of the proposed antenna. The results demonstrate that the proposed array antenna with optimal spacing is suitable for detecting interference signals with low RMS error.

The Effect of a Target Controlled Infusion of Low-Concentration Ketamine on the Heart Rate Variability of Normal Volunteers (정상인 자원자에서 목표농도조절주입법으로 투여한 저농도의 케타민이 심장박동수변이도에 미치는 영향)

  • Jung, Jai Yun;Lee, Jun Ho;Lee, Jeong Seok;Kim, Yong Ik
    • The Korean Journal of Pain
    • /
    • v.22 no.1
    • /
    • pp.39-46
    • /
    • 2009
  • Background: Ketamine has an indirect sympathetic stimulation effect. We investigated heart rate variability (HRV) as a marker of cardiac autonomic function after a target controlled infusion (TCI) of ketamine with a plasma concentration of 30 or 60 ng/ml. Methods: In 20 adult volunteers, the mean of the R wave to the adjacent R wave interval (RRI), the range of RRI, the root mean square successive difference of intervals (RMSSD), the total power, the low frequency (LF, 0.04-0.15 Hz) power, the high frequency (HF, 0.15-0.4 Hz) power, the normal unit HF (nuHF), the normal unit LF (nuLF), the LF/HF ratio and the SD1 and the SD2 in the Poincare plot were measured before and after a TCI of ketamine. We observed for any psychedelic symptoms or sedation. Results: There were no differences in the mean and range of the RRI, RMSSD, total power, LF power, HF power, nuHF, nuLF, LF/HF ratio, SD1 and SD2 between before and after ketamine administration. The OAA/S score was higher and there were more psychedelic symptoms with a 60 ng/ml plasma concentration than with a 30 ng/ml plasma concentration. Conclusions: This study did not show any effect of a low plasma concentration of ketamine on the autonomic nervous system.

Doppler Radar System for Long Range Detection of Respiration and Heart Rate (원거리에서 측정 가능한 호흡 및 심박 수 측정을 위한 도플러 레이더 시스템)

  • Lee, Jee-Hoon;Kim, Ki-Beom;Park, Seong-Ook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.4
    • /
    • pp.418-425
    • /
    • 2014
  • This paper presents a Ku-Band Doppler Radar System to measure respiration and heart rate. It was measured by using simultaneous radar and ECG(Electrocardiogram). Arctangent demodulation without dc offset compensation can be applied to transmitted I/Q(In-phase & Quadrature-phase) signal in order to improve the RMSE(Root Mean Square Error) about 50 %. The power leaked to receiving antenna from the transmitting antenna is always generated because of continuously opening the transceiver of CW(Continuous Wave) Doppler radar. As the output power increase, leakage power has an effect on the SNR(Signal-to-Noise Ratio) of the system. Therefore, in this paper, leakage cancellation technique that adds the signal having the opposite phase of the leakage power to the leakage power was implemented in order to minimize the decline of receiver sensitivity. By applying the leakage cancellation techniques described above, it is possible to measure the heart rate and respiration of the human at a distance of up to 35 m. the heart rate of the measured data at a distance of 35 m accords with the heart rate extracted from the ECG data.

Analysis, Design and Implementation of a Soft Switching DC/DC Converter

  • Lin, Bor-Ren
    • Journal of Power Electronics
    • /
    • v.13 no.1
    • /
    • pp.20-30
    • /
    • 2013
  • This paper presents a soft switching DC/DC converter for high voltage application. The interleaved pulse-width modulation (PWM) scheme is used to reduce the ripple current at the output capacitor and the size of output inductors. Two converter cells are connected in series at the high voltage side to reduce the voltage stresses of the active switches. Thus, the voltage stress of each switch is clamped at one half of the input voltage. On the other hand, the output sides of two converter cells are connected in parallel to achieve the load current sharing and reduce the current stress of output inductors. In each converter cell, a half-bridge converter with the asymmetrical PWM scheme is adopted to control power switches and to regulate the output voltage at a desired voltage level. Based on the resonant behavior by the output capacitance of power switches and the transformer leakage inductance, active switches can be turned on at zero voltage switching (ZVS) during the transition interval. Thus, the switching losses of power MOSFETs are reduced. The current doubler rectifier is used at the secondary side to partially cancel ripple current. Therefore, the root-mean-square (rms) current at output capacitor is reduced. The proposed converter can be applied for high input voltage applications such as a three-phase 380V utility system. Finally, experiments based on a laboratory prototype with 960W (24V/40A) rated power are provided to demonstrate the performance of proposed converter.

A High-Efficiency High-Power Step-Up Converter with Low Ripple Content

  • Kang Jeong-il;Roh Chung-Wook;Moon Gun-Woo;Youn Myung-Joong
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.708-712
    • /
    • 2001
  • A new phase-shifted parallel-input/series-output (PI SO) dual inductor-fed push-pull converter for high-power step­up applications is proposed. This converter is operated at a constant duty cycle and employs an auxiliary circuit to control the output voltage with a phase-shift between the two modules. It features a voltage conversion characteristic which is linear to changes in the control input, and high step-up ratio with a greatly reduced switch turn-off stress resulting in a significant increase in the converter efficiency. It also shows a low ripple content and low root-mean-square (RMS) current in the output capacitor. The operational principle is analyzed and a comparative analysis with the conventional pulse-width-modulated (PWM) PISO dual inductor-fed push-pull converter is presented. A 50kHz, 800W, 350Vdc prototype with an input of 20-32Vdc has also been constructed to validate the proposed converter. The proposed converter compares favorably with the conventional counterpart and is considered well suited to high-power step-up applications.

  • PDF

An Improved Photovoltaic System Output Prediction Model under Limited Weather Information

  • Park, Sung-Won;Son, Sung-Yong;Kim, Changseob;LEE, Kwang Y.;Hwang, Hye-Mi
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.5
    • /
    • pp.1874-1885
    • /
    • 2018
  • The customer side operation is getting more complex in a smart grid environment because of the adoption of renewable resources. In performing energy management planning or scheduling, it is essential to forecast non-controllable resources accurately and robustly. The PV system is one of the common renewable energy resources in customer side. Its output depends on weather and physical characteristics of the PV system. Thus, weather information is essential to predict the amount of PV system output. However, weather forecast usually does not include enough solar irradiation information. In this study, a PV system power output prediction model (PPM) under limited weather information is proposed. In the proposed model, meteorological radiation model (MRM) is used to improve cloud cover radiation model (CRM) to consider the seasonal effect of the target region. The results of the proposed model are compared to the result of the conventional CRM prediction method on the PV generation obtained from a field test site. With the PPM, root mean square error (RMSE), and mean absolute error (MAE) are improved by 23.43% and 33.76%, respectively, compared to CRM for all days; while in clear days, they are improved by 53.36% and 62.90%, respectively.

Mid- and Short-term Power Generation Forecasting using Hybrid Model (하이브리드 모델을 이용하여 중단기 태양발전량 예측)

  • Nam-Rye Son
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.4_2
    • /
    • pp.715-724
    • /
    • 2023
  • Solar energy forecasting is essential for (1) power system planning, management, and operation, requiring accurate predictions. It is crucial for (2) ensuring a continuous and sustainable power supply to customers and (3) optimizing the operation and control of renewable energy systems and the electricity market. Recently, research has been focusing on developing solar energy forecasting models that can provide daily plans for power usage and production and be verified in the electricity market. In these prediction models, various data, including solar energy generation and climate data, are chosen to be utilized in the forecasting process. The most commonly used climate data (such as temperature, relative humidity, precipitation, solar radiation, and wind speed) significantly influence the fluctuations in solar energy generation based on weather conditions. Therefore, this paper proposes a hybrid forecasting model by combining the strengths of the Prophet model and the GRU model, which exhibits excellent predictive performance. The forecasting periods for solar energy generation are tested in short-term (2 days, 7 days) and medium-term (15 days, 30 days) scenarios. The experimental results demonstrate that the proposed approach outperforms the conventional Prophet model by more than twice in terms of Root Mean Square Error (RMSE) and surpasses the modified GRU model by more than 1.5 times, showcasing superior performance.

Evaluation of Horticultural Therapy on the Emotional Improvement of Depressed Patients by Using Heart Rate Variability (심박변이도를 이용한 우울증 환자의 정서개선에 미치는 원예치료 효과 분석)

  • Song, Mi-Jin;Kim, Mi-Young;Sim, Iee-Sung;Kim, Wan-Soon
    • Horticultural Science & Technology
    • /
    • v.28 no.6
    • /
    • pp.1066-1071
    • /
    • 2010
  • To evaluate the effect of horticultural therapy (HT) on the emotional improvement of depressed patients, computer-based heart rate variability (HRV) was compared with self-report scale (SRS) known as existing subjective evaluation method. SRS included four test areas: mental stress scale (MSS), physical stress scale (PSS), Beck anxiety inventory (BAI), and Beck depression inventory (BDI). HRV was itemized into four parameters: standard deviation of the N-N intervals (SDNN), square root of mean squared difference of successive N-N intervals (RMSSD), total power (TP), and low-frequency/high-frequency ratio (LF/HF ratio). Thirty patients with depression at the same mental hospital participated in this study. 15 patients of the treatment group received HT once a week for three months, but the control group did not during the same period. As a result, the emotional improvement in treatment group was clearly identified through HRV as well as SRS. The significant difference was shown at three test areas (MSS, BAI, and BDI, $p$ < 0.001) in SRS and at one parameter (total power, $p$ < 0.05) in HRV. There was noticeable increase in SDNN, RMSSD, and LF/HF ratio in treatment group after HT activity, but no significant difference. Although all parameters of HRV did not show significance, the possibility of HRV as an objective evaluation method to HT was recognized in this study. These results also implied that HT was efficient in the mental and physical regeneration of the depressed patients in both subjective and objective evaluation methods.

The Intertidal Area in Lake Sihwa After Operation of the Tidal Power Plant (조력발전소 가동 후 시화호 내 조간대의 면적 변화)

  • Kim, Minkyu;Koo, Bon Joo
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.18 no.4
    • /
    • pp.310-316
    • /
    • 2015
  • The intertidal area in Lake Sihwa formed after operation of Sihwa-Lake tidal power plant and the change of the area in Lake Sihwa by period were analyzed. For computation of the intertidal area, remote sensing techniques were applied and high resolution Digital Elevation Model (DEM) was generated with root mean square (rms) error 14.4 cm. The intertidal area was $165.1km^2$ in 1910s, $115.2km^2$ in 1991 before completion of Sihwa dyke, $5.6km^2$ in 2010 during the period on operation of sluice gate, and $20.3km^2$ in 2013 after operation of Sihwa tidal power plant. Intertidal in Lake Sihwa was nearly dissipated after completion of Sihwa dyke, but significantly increased with operation of Sihwa tidal power plant from April 2012 as developing a regular tide environment and increasing of sea water flux. The re-formation of tidal flat of Sihwa Lake is an uncommon case. This study that precisely analyzed on the area of artificially formed Sihwa tidal flat would be applicable for management and making conservation plan.