• Title/Summary/Keyword: Root canal systems

Search Result 67, Processing Time 0.022 seconds

The instrument-centering ability of four Nickel-Titanium instruments in simulated curved root canals (만곡된 레진 모형 근관에서 4종의 엔진 구동형 니켈-티타늄 기구의 근관 중심율 유지 능력)

  • Ku, Jae-Hoon;Chang, Hoon-Sang;Chang, Seok-Woo;Cho, Hwan-Hee;Bae, Ji-Myung;Min, Kyung-San
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.2
    • /
    • pp.113-118
    • /
    • 2006
  • The aim of this study was to evaluate the ability of newly marketed NRT instruments to maintain the original root canal configuration and curvature during preparation in comparison with the three existing instruments in simulated root canals. Simulated canals in resin blocks were prepared with ProFile. K3, ProTaper and NRT instrument (n = 10 canals in each case). Pre- and post-operative images were recorded, and assessment of canal shape was completed with a computer image analysis program. The data were analyzed statistically using the One-way ANOVA followed by Duncan s test. The ability or instruments to remain centered in prepared canals at 1-, 2-mm levels was significantly better in ProFile groups than in other groups (p < 0.05). The change of centering ratio in NRT groups at 5-mm level was significantly greater than ProFile group and at 6- and 7-mm level than all other groups (p < 0.05). Although the NRT system was comparable to other systems in regards to its ability to maintain the canal configuration of apical portion, this system was more influenced by the mid-root curvature due to its stainless-steel files for coronal preflaring.

Mandibular lateral incisor with four root canals: A unique case of double tooth diagnosed using multidetector computed tomography

  • Gupta, Sunil Kumar;Gupta, Jaya;Acharya, Shashi Rashmi;Ather, Amber
    • Imaging Science in Dentistry
    • /
    • v.43 no.2
    • /
    • pp.123-128
    • /
    • 2013
  • Double tooth is a dental anomaly consequent to fusion of two or more teeth or gemination of a single tooth. This report describes a unique case of double tooth in relation to a mandibular lateral incisor exhibiting the presence of four root canals. The role of conventional radiography and advanced three-dimensional imaging techniques in the better assessment of complex root canal systems and their aid in endodontic management has also been highlighted.

Comparison of screw-in effect of three NiTi file systems used by undergraduates (학생들이 사용한 세 종류 NiTi file systems의 screw-in effect 비교)

  • Oh, Seung-Hei;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.6
    • /
    • pp.477-484
    • /
    • 2006
  • The purposes of this study were to compare the apical terminus width of simulated curved root canal prepared with three NiTi file systems used by undergraduates for evaluation the effects of flute angle and pitch or radial land on reducing screw-in effect and to determine more safe NiTi file system for inexperienced operators. Fifty inexperienced undergraduate students prepared 150 simulated curved root canals in resin blocks with three NiTi file systems ; ProFile$^{(R)}$, Hero Shaper$^{(R)}$, K3$^{TM}$. The electric motor set at a speed of 300 rpm and torque of 30 in a 16 : 1 reduction handpiece was used. The simulated root canal was prepared to ISO #25 sizes with each file system. The scanned images of pre- and post-instrumented canal of resin block were superimposed. To evaluate the screw-in effect of three NiTi file systems, apical terminus width of root canal was measured from superimposed images and statistical analysis was performed. There were significant differences in three NiTi flle systems. ProFile$^{(R)}$ had significantly smaller width than Hero Shaper$^{(R)}$ and K3$^{TM}$"" (P < 0.05), but no significant difference was observed between K3$^{TM}$ and Hero Shaper$^{(R)}$. Under the condition of this study, active file system (Hero SHaper$^{(R)}$, K3$^{TM}$) with variable pitch and helical angle had more screw-in effect than passive file system (ProFile$^{(R)}$) with constant pitch and helical angle. It seems that the radial lands play more important role in reducing screw-in effect.

Comparative evaluation of the effectiveness of ultrasonic tips versus the Terauchi file retrieval kit for the removal of separated endodontic instruments

  • Pruthi, Preeti Jain;Nawal, Ruchika Roongta;Talwar, Sangeeta;Verma, Mahesh
    • Restorative Dentistry and Endodontics
    • /
    • v.45 no.2
    • /
    • pp.14.1-14.7
    • /
    • 2020
  • Objective: The aim of this study was to perform a comparative evaluation of the effectiveness of ultrasonic tips versus the Terauchi file retrieval kit (TFRK) for the removal of broken endodontic instruments. Materials and Methods: A total of 80 extracted human first mandibular molars with moderate root canal curvature were selected. Following access cavity preparation canal patency was established with a size 10/15 K-file in the mesiobuccal canals of all teeth. The teeth were divided into 2 groups of 40 teeth each: the P group (ProUltra tips) and the T group (TFRK). Each group was further subdivided into 2 smaller groups of 20 teeth each according to whether ProTaper F1 rotary instruments were fractured in either the coronal third (C constituting the PC and TC groups) or the middle third (M constituting the PM and TM groups). Instrument retrieval was performed using either ProUltra tips or the TFRK. Results: The overall success rate at removing the separated instrument was 90% in group P and 95% in group T (p > 0.05) The mean time for instrument removal was higher with the ultrasonic tips than with the TFRK (p > 0.05). Conclusion: Both systems are acceptable clinical tools for instrument retrieval but the loop device in the TFRK requires slightly more dexterity than is needed for the ProUltra tips.

Comparison of vibration characteristics of file systems for root canal shaping according to file length

  • Seong-Jun Park;Se-Hee Park ;Kyung-Mo Cho ;Hyo-Jin Ji ;Eun-Hye Lee ;Jin-Woo Kim
    • Restorative Dentistry and Endodontics
    • /
    • v.45 no.4
    • /
    • pp.51.1-51.10
    • /
    • 2020
  • Objectives: No studies have yet assessed vibration characteristics according to endodontic file length. Accordingly, the objective of the present study was to examine the vibration characteristics according to nickel-titanium file length and to compare these characteristics between different file systems. Materials and Methods: A total of 45 root canal models were divided into 3 experimental groups (n = 15 each) based on the file system used (ProTaper Gold [PTG], ProTaper Next, or WaveOne Gold [WOG]). Each experimental group was further divided into 3 subgroups according to file length (21, 25, or 31 mm). An electric motor (X-SMART PLUS) was used in the experiment. For each file system, vibrations generated when using a size 25 file were measured and used to calculate the average vibration acceleration. The differences in vibrations were analyzed using 1-way analysis of variance and the Scheffé post hoc test with a confidence interval of 95%. Results: In the PTG file system, significantly lower vibration acceleration was observed when using a 21-mm file than when using a 31-mm file. In the WOG file system, significantly stronger vibration acceleration was observed when using a 31-mm file than when using 21- or 25-mm files. Regardless of the file length, the WOG group exhibited significantly stronger vibration acceleration than the other 2 experimental groups. Conclusions: In clinical practice, choosing a file with the shortest length possible could help reduce vibrations. Additionally, consideration should be given to vibrations that could be generated when using WOG files with reciprocating motion.

THE EFFECTS OF CELL WALL PROTEINS OF STREPTOCOCCUS SPP. ON DNA SYNTHESIS OF L929 CELLS AND THEIR SDS-PAGE PATTERNS (연쇄 구균의 세포벽 단백질이 L929 세포의 DNA합성에 미치는 영향 및 SDS-PAGE 양상에 관한 연구)

  • Lee, Se-Jong;Im, Mi-Kyung
    • Restorative Dentistry and Endodontics
    • /
    • v.20 no.1
    • /
    • pp.71-95
    • /
    • 1995
  • Bacteria have been regarded as a one of major etiologic factors in root canal infections. In endodontic treatment the effective removal of pathogenic microorganisms in the root canal is the key to successful outcome. Bacterial cell wall components may play an important role in the development of pulpal and periapical disease. The purpose of this study was to evaluate the effect of sonic extracts of Streptococcus spp. on cultured L929 cells and to characterize cell wall protein profiles of Streptococcus spp. Streptococcus spp. were isolated from infected root canals and identified with Vitek Systems(Biomeriux, USA). Five streptococci, namely S. sanguis, S. mitis, S uberis, S. mutans (ATCC 10449) and S. faecalis (ATCC 19433) weere enriched in brain heart infusion broth. Cell pellets were sonicated and cell wall extracts were dialyzed and membrane filtered. Prepared cell wall proteins were applied to cultured L929 cell. The cell reaction were evaluated by monitoring DNA synthesis, cell numbers and the change of cell morphology. The total cell wall protein profiles of microorganisms were characterized by sodium dodecyl sulfate polyacrylamide-gel eledruphoresis(SDS-PAGE). DNA synthesis of L929 cells were reduced by the increasing concentration of sonic extracts. DNA synthesis was significantly suppressed in more than $50{\mu}g$/ml of sonic extract conentration in five streptococci. S. nutans (ATCC 10449) showed stronger suppression on DNA synthesis than remaining four streptococci, which had the similar effect on DNA synthesis. Analysis of DNA synthesis measured by [$^3H$]-thymidine uptake was more sensitvie method than cell counting. Sonic extracts affected the microscopic findings of L929 cells. The protein profiles indicated that all five strains shared two major proteins with molecular masses of 70.8 and 57.5 kD respectively. S. uberis and S. mutans shared common minor proteins of which molecular weights were 147.9 and 112.2 kD respectively. However some minor proteins were unique for S. mitis, S. uberis and S. faecalis.

  • PDF

Determining the reliability of diagnosis and treatment using artificial intelligence software with panoramic radiographs

  • Kaan Orhan;Ceren Aktuna Belgin;David Manulis;Maria Golitsyna;Seval Bayrak;Secil Aksoy;Alex Sanders;Merve Onder;Matvey Ezhov;Mamat Shamshiev;Maxim Gusarev;Vladislav Shlenskii
    • Imaging Science in Dentistry
    • /
    • v.53 no.3
    • /
    • pp.199-207
    • /
    • 2023
  • Purpose: The objective of this study was to evaluate the accuracy and effectiveness of an artificial intelligence (AI) program in identifying dental conditions using panoramic radiographs(PRs), as well as to assess the appropriateness of its treatment recommendations. Materials and Methods: PRs from 100 patients(representing 4497 teeth) with known clinical examination findings were randomly selected from a university database. Three dentomaxillofacial radiologists and the Diagnocat AI software evaluated these PRs. The evaluations were focused on various dental conditions and treatments, including canal filling, caries, cast post and core, dental calculus, fillings, furcation lesions, implants, lack of interproximal tooth contact, open margins, overhangs, periapical lesions, periodontal bone loss, short fillings, voids in root fillings, overfillings, pontics, root fragments, impacted teeth, artificial crowns, missing teeth, and healthy teeth. Results: The AI demonstrated almost perfect agreement (exceeding 0.81) in most of the assessments when compared to the ground truth. The sensitivity was very high (above 0.8) for the evaluation of healthy teeth, artificial crowns, dental calculus, missing teeth, fillings, lack of interproximal contact, periodontal bone loss, and implants. However, the sensitivity was low for the assessment of caries, periapical lesions, pontic voids in the root canal, and overhangs. Conclusion: Despite the limitations of this study, the synthesized data suggest that AI-based decision support systems can serve as a valuable tool in detecting dental conditions, when used with PR for clinical dental applications.

Combination of a new ultrasonic tip with rotary systems for the preparation of flattened root canals

  • Karina Ines Medina Carita Tavares ;Jader Camilo Pinto ;Airton Oliveira Santos-Junior ;Fernanda Ferrari Esteves Torres ;Juliane Maria Guerreiro-Tanomaru ;Mario Tanomaru-Filho
    • Restorative Dentistry and Endodontics
    • /
    • v.46 no.4
    • /
    • pp.56.1-56.11
    • /
    • 2021
  • Objectives: This study evaluated 2 nickel-titanium rotary systems and a complementary protocol with an ultrasonic tip and a small-diameter instrument in flattened root canals. Materials and Methods: Thirty-two human maxillary second premolars with flattened canals (buccolingual diameter ≥4 times larger than the mesiodistal diameter) at 9 mm from the radiographic apex were selected. The root canals were prepared by ProDesign Logic (PDL) 30/0.01 and 30/0.05 or Hyflex EDM (HEDM) 10/0.05 and 25/0.08 (n = 16), followed by application of the Flatsonic ultrasonic tip in the cervical and middle thirds and a PDL 25/0.03 file in the apical third (FPDL). The teeth were scanned using micro-computed tomography before and after the procedures. The percentage of volume increase, debris, and uninstrumented surface area were analyzed using the Kruskal-Wallis, Dunn, Wilcoxon, analysis of variance/Tukey, and paired and unpaired t-tests (α = 0.05). Results: No significant difference was found in the volume increase and uninstrumented surface area between PDL and HEDM (p > 0.05). PDL had a higher percentage of debris than HEDM in the middle and apical thirds (p < 0.05). The FPDL protocol resulted in less debris and uninstrumented surface area for PDL and HEDM (p < 0.05). This protocol, with HEDM, reduced debris in the middle and apical thirds and uninstrumented surface area in the apical third (p < 0.05). Conclusions: High percentages of debris and uninstrumented surface area were observed after preparation of flattened root canals. The HEDM, Flatsonic tip, and 25/0.03 instrument protocol enhanced cleaning in flattened root canals.

EXPERIMENTAL STUDY ON SEALING QUALITY OF POLYCARBOXYLATE CEMENT USED AS ROOT CANAL SEALER (카복실레이트 세멘트를 근관(根管) 충전재(充塡材)로 사용(使用) 시(時) 근관(根管) 폐쇄성(閉鏁性)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Hwang, Young-Hwan
    • Restorative Dentistry and Endodontics
    • /
    • v.2 no.1
    • /
    • pp.32-37
    • /
    • 1976
  • The author has studied comparatively the sealing quality of polycarboxylate cement, one of the newest dental cement systems, and zinc oxide eugenol cement by means of penetration of 2% methylene blue solution through the root apex of human teeth in 72 cases as time elapsed. Followings are the results obtained from this study. 1) In all groups, there was no increase in penetration related to increased time of immersion in the dye. 2) In polycarboxylate cement groups, there was a significant difference in depth of dye penetration of each tooth, but in zinc oxide eugenol cement group, there was a slight difference. 3) The depth of dye penetration of zinc oxide eugenol cement group is slightly lower than that of poly carboxylate cement groups. 4) In polycarboxylate cement groups, Carbolit cement group showed comparatively lower grade of dye penetration than Carbo cement group.

  • PDF

COMPARISON OF SCREW-IN EFFECT FOR SEVERAL NICKEL-TITANIUM ROTARY INSTRUMENTS IN SIMULATED RESIN ROOT CANAL (모형 레진 근관에서 수종의 전동 니켈-티타늄 파일에 대한 screw-in effect 비교)

  • Ha, Jung-Hong;Jin, Myoung-Uk;Kim, Young-Kyung;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.4
    • /
    • pp.267-272
    • /
    • 2010
  • Screw-in effect is one of the unintended phenomena that occurs during the root canal preparation with nickel-titanium rotary files. The aim of this study was to compare the screw-in effect among various nickel-titanium rotary file systems. Six different nickel-titanium rotary instruments (ISO 20/.06 taper) were used: $K3^{TM}$ (SybronEndo, Glendora, CA, USA), $M_{two}$ (VDW GmbH, Munchen, Germany), NRT with safe-tip and with active tip (Mani Inc., Shioya-gun, Japan), ProFile$^{(R)}$ (Dentsply-Maillefer, Ballaigues, Switzerland) and ProTaper$^{(R)}$ (Dentsply-Maillefer, Ballaigues, Switzerland). For ProTaper$^{(R)}$, S2 was selected because it has size 20. Root canal instrumentations were done in sixty simulated single-curved resin root canals with a rotational speed of 300 rpm and single pecking motion. A special device was designed to measure the force of screw-in effect. A dynamometer of the device recorded the screw-in force during simulated canal preparation and the recorded data was stored in a computer with designed software (LCV-USE-VS, Lorenz Messtechnik GmbH, Alfdorf, Germany). The data were subjected to one-way ANOVA and Tukey's multiple range test for post-hoc test. P value of less than 0.05 was regarded significant. ProTaper$^{(R)}$ produced significantly more screw-in effects than any other instruments in the study (p < 0.001). $K3^{TM}$ produced significantly more screw-in effects than $M_{two}$, and ProFile$^{(R)}$ (p < 0.001). There was no significant difference among $M_{two}$, NRT, and ProFile$^{(R)}$ (p > 0.05), and between NRT with active tip and NRT with safe one neither (p > 0.05). From the result of the present study, it was concluded, therefore, that there seems significant differences of screw-in effect among the tested nickel-titanium rotary instruments. The radial lands and rake angle of nickel-titanium rotary instrument might be the cause of the difference.