• Title/Summary/Keyword: Root Resolution

Search Result 309, Processing Time 0.03 seconds

ALVEOLAR BONE LOSS & BONE DENSITY CHANCES DURING THE FIRST YEAR A COMPARATIVE STUDY ON FOUR TYPES OF ROOT-FORM ENDOSSEOUS DENTAL IMPLANT SYSTEMS (치근형 골내 임플란트의 초기 1년간 치조골 소실 및 골 밀도 변화에 관한 연구)

  • Jung Young-Chul;Han Chong-Hyun;Lee Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.32 no.3
    • /
    • pp.455-469
    • /
    • 1994
  • Regular radiographic examination has been considered an essential diagnositic method for osseointegrated dental implantation. This study investigated marginal bone loss through the measurement on periapical radiographs and changes in bone density through digital subtraction image radiographic method around 88 endoseous root-form dental implants in 43 human subjects. Four types of endosseous dental implants were investigated : Standard series, Mini series and Hex-lock system of Steri-Oss Dental implant system, and $Br{\aa}nemark$-type implant from 3i dental implant system, in a 3 month interval for a total period of 12 months. The results were as follows : 1. Rapid bone loss occurred in the first 3 months in all 4 groups, and the bone level stabilized at the first thread of the implant fixtures. Amount of bone loss for 12 months showed correlation with the length of the polished neck portion. 2. Most of the implant systems showed resorption of alveolar bone up to the polished neck portion although a long polished neck could delay the resolution. 3. Alveolar bone loss apical to the polished neck portion stabilized at the first thread of the fixtures with no correlation to either the time of exposure of the polished neck or types of implant systems. 4. No changes in bone density around the implant threads were observed throughout the experimental period. Bone density decreased at the marginal bone, and increased at the newly-formed alveolar crest. These results indicate that most of the alveolar bone loss occur within the first 12 months after installation of endosseous root-form dental implants resulting in the exposure of polished neck portions, and the bone level stabilizes thereafter at the first thread portions of the implant fixtures. The experimental period of 12 months seems insufficient for observing changes in bone density, and a long-term observation should be needed.

  • PDF

A Study on the Retrieval of River Turbidity Based on KOMPSAT-3/3A Images (KOMPSAT-3/3A 영상 기반 하천의 탁도 산출 연구)

  • Kim, Dahui;Won, You Jun;Han, Sangmyung;Han, Hyangsun
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.6_1
    • /
    • pp.1285-1300
    • /
    • 2022
  • Turbidity, the measure of the cloudiness of water, is used as an important index for water quality management. The turbidity can vary greatly in small river systems, which affects water quality in national rivers. Therefore, the generation of high-resolution spatial information on turbidity is very important. In this study, a turbidity retrieval model using the Korea Multi-Purpose Satellite-3 and -3A (KOMPSAT-3/3A) images was developed for high-resolution turbidity mapping of Han River system based on eXtreme Gradient Boosting (XGBoost) algorithm. To this end, the top of atmosphere (TOA) spectral reflectance was calculated from a total of 24 KOMPSAT-3/3A images and 150 Landsat-8 images. The Landsat-8 TOA spectral reflectance was cross-calibrated to the KOMPSAT-3/3A bands. The turbidity measured by the National Water Quality Monitoring Network was used as a reference dataset, and as input variables, the TOA spectral reflectance at the locations of in situ turbidity measurement, the spectral indices (the normalized difference vegetation index, normalized difference water index, and normalized difference turbidity index), and the Moderate Resolution Imaging Spectroradiometer (MODIS)-derived atmospheric products(the atmospheric optical thickness, water vapor, and ozone) were used. Furthermore, by analyzing the KOMPSAT-3/3A TOA spectral reflectance of different turbidities, a new spectral index, new normalized difference turbidity index (nNDTI), was proposed, and it was added as an input variable to the turbidity retrieval model. The XGBoost model showed excellent performance for the retrieval of turbidity with a root mean square error (RMSE) of 2.70 NTU and a normalized RMSE (NRMSE) of 14.70% compared to in situ turbidity, in which the nNDTI proposed in this study was used as the most important variable. The developed turbidity retrieval model was applied to the KOMPSAT-3/3A images to map high-resolution river turbidity, and it was possible to analyze the spatiotemporal variations of turbidity. Through this study, we could confirm that the KOMPSAT-3/3A images are very useful for retrieving high-resolution and accurate spatial information on the river turbidity.

Tissue-specific systemic responses of the wild tobacco Nicotiana attenuata against stem-boring herbivore attack

  • Lee, Gisuk;Joo, Youngsung;Baldwin, Ian T.;Kim, Sang-Gyu
    • Journal of Ecology and Environment
    • /
    • v.45 no.3
    • /
    • pp.143-151
    • /
    • 2021
  • Background: Plants are able to optimize defense responses induced by various herbivores, which have different feeding strategies. Local and systemic responses within a plant after herbivory are essential to modulate herbivore-specific plant responses. For instance, leaf-chewing herbivores elicit jasmonic acid signaling, which result in the inductions of toxic chemicals in the attacked leaf (tissue-specific responses) and also in the other unattacked parts of the plant (systemic responses). Root herbivory induces toxic metabolites in the attacked root and alters the levels of transcripts and metabolites in the unattacked shoot. However, we have little knowledge of the local and systemic responses against stem-boring herbivores. In this study, we examined the systemic changes in metabolites in the wild tobacco Nicotiana attenuata, when the stem-boring herbivore Trichobaris mucorea attacks. Results: To investigate the systemic responses of T. mucorea attacks, we measured the levels of jasmonic acid (JA), JA-dependent secondary metabolites, soluble sugars, and free amino acids in 7 distinct tissues of N. attenuata: leaf lamina with epidermis (LLE), leaf midrib (LM), stem epidermis (SE), stem pith (SP), stem vascular bundle (SV), root cortex with epidermis (RCE), and root vascular bundle (RV). The levels of JA were increased in all root tissues and in LM by T. mucorea attacks. The levels of chlorogenic acids (CGAs) and nicotine were increased in all stem tissues by T. mucorea. However, CGA was systematically induced in LM, and nicotine was systematically induced in LM and RCE. We further tested the resource allocation by measuring soluble sugars and free amino acids in plant tissues. T. mucorea attacks increased the level of free amino acids in all tissues except in LLE. The levels of soluble sugars were significantly decreased in SE and SP, but increased in RV. Conclusions: The results reveal that plants have local- and systemic-specific responses in response to attack from a stem-boring herbivore. Interestingly, the level of induced secondary metabolites was not consistent with the systemic inductions of JA. Spatiotemporal resolution of plant defense responses against stem herbivory will be required to understand how a plant copes with attack from herbivores from different feeding guilds.

THE STUDY OF AERO-ACOUSTICS CHARACTERISTIC BY BOUNDARY CONDITIONS (경계조건에 따른 공력음향 특성에 관한 연구)

  • Lee, S.S.;Kim, J.S.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.75-80
    • /
    • 2009
  • The present paper focuses on the analysis of aero-acoustics characteristic by several boundary conditions. In this simulation, a high-order and high-resolution numerical schemes are used for the accurate computation of compressible flow with several boundary conditions including characteristic boundary conditions as well as extrapolation and zonal characteristic boundary condition. These boundary conditions are applied to the computation of two dimensional circular cylinder flows with Mach number of 0.3 and Reynolds number of 400. The computation results are validated with measurement datum and other computation results for the Strouhal frequency of vortex shedding, the mean drag coefficient and root-mean-square lift for the unsteady periodic flow regime. Secondary frequency is predicted by three kinds of boundary conditions characteristic.

  • PDF

Estimation of Insolation over the Oceans around Korean Peninsula Using Satellite Data

  • Park, Kyung-Won;Kim, Young-seup;Sang, Chung-Hyo
    • Proceedings of the KSRS Conference
    • /
    • 1999.11a
    • /
    • pp.227-230
    • /
    • 1999
  • Surface solar radiation over the sea is estimated using Visible and Infrared Spin Scan Radiometer data onbord Geostationary Meteorological Satellite(GMS) 5 for January, 1997 to December 1997 in clear and cloudy conditions. The hourly insolation is estimated with a spatial resolution of 5$\times$ 5 km grid. The island pyranometer belonging to the Japan Meteorological Agency is used for validation of the estimated insolation. It is shown that the estimated hourly insolation has RMSE(root mean square) error of 104 W/$m^2$. The variability of the hourly solar radiation was investigated on 3 areas over seas around Korean Peninsula. The solar radiation of East Sea is similar to Yellow Sea. The maximum value of solar radiation is on June of year. The maximum value in south sea is on August because weather is poor by low pressure and front in June

  • PDF

Microsurgical Excision of Symptomatic Sacral Perineurial Cyst with Sacral Recapping Laminectomy : A Case Report in Technical Aspects

  • Seo, Dae-Hyun;Yoon, Kyeong-Wook;Lee, Sang Koo;Kim, Young-Jin
    • Journal of Korean Neurosurgical Society
    • /
    • v.55 no.2
    • /
    • pp.110-113
    • /
    • 2014
  • Perineurial cysts (Tarlov cysts) are lesions of the nerve root that are often observed in the sacral area. There is debate about whether symptomatic perineurial cysts should be treated surgically. We presented three patients with symptomatic perineurial cyst who were treated surgically, and introduced sacral recapping laminectomy. Patients complained of low back pain and hypesthesia on lower extremities. We performed operations with sacral recapping technique for all three. The outcome measure was baseline visual analogue score and post operative follow up magnetic resonance images. All patients were completely relieved of symptoms after operation. Although not sufficient to address controversies, this small case series introduces successful use of a particular surgical technique to treat sacral perineural cyst, with resolution of most symptoms and no sequelae.

Design of a Digital PWM Controller for a Soft Switching SEPIC Converter

  • Nashed, Maged N.F.
    • Journal of Power Electronics
    • /
    • v.4 no.3
    • /
    • pp.152-160
    • /
    • 2004
  • This paper presents analysis, modeling, and design of a low-harmonic, isolated, active-clamped SEPIC for future avionics applications. Simpler converter dynamics, high switching frequency, zero voltage-Transition-PWM switching, and a single-layer transformer construction result. This paper describes complete design of a digital controller for a high-frequency switching power supply. Guidelines for the minimum required resolution of the analog-to-digital converter, the pulse-width modulator, and the fixed-point computational unit is derived. A design example based on a SEPIC converter operating at the high switching frequency is presented. The controller design is based on direct digital design approach and standard root-locus techniques.

Electrical Power and Energy Reference Measurement System with Asynchronous Sampling (비동기 샘플링에 의한 전력과 에너지 측정 기준시스템)

  • Wijesinghe, W.M.S.;Park, Young-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.684_685
    • /
    • 2009
  • A digital sampling algorithm that uses a two high resolution integrating Voltmeters which are synchronized by Phase Lock Loop (PLL) time clock for accurately measuring the parameters, active and reactive power, for sinusoidal power measurements is presented. The PLL technique provides high precision measurements, root mean square (rms), phase and complex voltage ratio, of the AC signal. The system has been designed to be used at the Korean Research Institute of Standards and Science (KRISS) as a reference power standard for electrical power calibrations. The test results have shown that the accuracy of the measurements is better than $10 {\mu}W/VA$ and the level of uncertainty is valid for the power factor range zero to 1 for both lead and lag conditions. The system is fully automated and allows power measurements and calibration of high precision wattmeters and power calibrators at the main power frequencies 50 and 60 Hz.

  • PDF

A Study on the Performance Improvement in Sidelobe Suppression for Pulse Compression of LFM Signal (LFM 신호의 펄스압축에 대한 부엽억제 성능향상 기법연구)

  • Shin, Jeong-Hoon
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.9 no.3
    • /
    • pp.95-100
    • /
    • 2006
  • The pulse compression technique using Linear FM signal is commonly used for improving the performance of both the detection range and range resolution in radar system. In general, the compressed LFM waveform has relatively large sidelobe level which may prevent a target from being detected when strong jammer or clutter signal is near the target signal. In this paper, we propose a new weighting method which uses the square-root weight to suppress the sidelobe level. Typical applications are missile seekers and tracking radar systems where target tracking range is available prior to the signal processing. By computer simulation, we show that the performance of the proposed method is better than that of the conventional weighting methods in terms of sidelobe suppression.

An Implementation of Discrete Mathematical Model for ECG waveform

  • Yimman, Surapun;Deeudom, Mongkon;Ittisariyanon, Jirawat;Junnapiya, Somyot;Dejhan, Kobchai
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.852-856
    • /
    • 2005
  • This paper proposes a new design of the ECG simulator with high resolution by using small amount of memories based on discrete least square estimation equations instead of reading the stored data inside the look-up table. The experimental results have shown that the ECG simulator using discrete least square estimation equations can display the bipolar limb leads ECG signals with low PRD (percent root-mean-square difference) while taking the less amount of memories than the previous method which used the look-up table to store ECG data for ECG simulation.

  • PDF