• Title/Summary/Keyword: Room-temperature distribution

Search Result 422, Processing Time 0.025 seconds

Goss Texture Development of Asymmetrically Rolled IF Steel Sheet (비대칭 압연한 IF 강 판의 Goss 집합조직 발달)

  • Kim, I.;Nam, S.K.;Kim, G.H.;Lee, D.N.
    • Transactions of Materials Processing
    • /
    • v.26 no.3
    • /
    • pp.150-155
    • /
    • 2017
  • To obtain the Goss texture, {110}<001>, IF steel sheets were asymmetrically rolled by 50-89% reduction in the thickness at room temperature and subsequently annealed at 200, 900, and $1200^{\circ}C$ in a box furnace under air atmosphere. The asymmetrically rolled specimens and annealed specimens show well-developed Goss texture, {110}<001>. After the IF steel sheets were asymmetrically rolled at room temperature and subsequently annealed at $900^{\circ}C$ for 1 h in a box furnace under air atmosphere, the intensity of the Goss texture, {110}<001> was high in the IF steel sheets.

Synthesis of Submicron Silver Particle Using Room Temperature Ionic Liquids (상온 이온성 액체를 이용한 미세 은 입자 제조)

  • Yoo, Kye Sang
    • Applied Chemistry for Engineering
    • /
    • v.23 no.1
    • /
    • pp.14-17
    • /
    • 2012
  • Submicron silver particles were synthesized by chemical reduction with various room temperature ionic liquids. The size and distribution of silver particles were significantly affected by the anion type of ionic liquids and this is mainly attributed to the different abilities of the anions to coordinate with the silver particle, leading to various coagulation of silver particles. Among ionic liquids, 1-butyl-3-methylimidazolium hexafluorophosphate was the most effective to synthesize submicron silver particles.

Preparation of Porous Silica-Pillared Montmorillonite: Simultaneous Intercalation of Amine-Tetraethylorthosilicate into H-Montmorillonite and Intra-Gallery Amine-Catalyzed Hydrolysis of Tetraethylorthosilicate

  • Gwon, O Yun;Park, Gyeong Won;Jeong, Sun Yeong
    • Bulletin of the Korean Chemical Society
    • /
    • v.22 no.7
    • /
    • pp.678-684
    • /
    • 2001
  • Porous silica-pillared montmorillonites were prepared by simultaneous intercalation of dodecylamine-TEOS [tetraethylorthosilicate, Si(OC2H5)4] into the H-montmorillonite and intragallery amine-catalyzed hydrolysis of TEOS. Mixtures of the H-montmorillonite, dodecylamine and TEOS at molar ratios of 1 : 2 : 15-30 and 1 : 2-6 : 20 resulted to swollen and viscous gel once at room temperature, allowing intercalation compounds which dodecylamine and TEOS were simultaneously intercalated into interlayer of H-montmorillonite. The hydrolysis of the gallery TEOS was conducted in water solution for 40 min at room temperature, affording siloxane-pillared H-montmorillonite. Calcination of samples at 500 $^{\circ}C$ in air resulted in silica-pillared montmorillonite with large specific surface areas between 403 and 577 m2 /g, depending on the reaction stoichiometry. The reaction at H-montmorillonite : dodecylamine : TEOS reaction stoichiometries of 1 : 2 : 15 and 1 : 4 : 20 resulted in high specific surface areas and mesopores with a narrow pore size distribution. Result indicates that the intragallery-amine catalyze the hydrolysis of gallery-TEOS and simultaneously have a role of gallery-templated micellar assemblies.

Field Measurements and CFD Simulations of Indoor Thermal Environments in the Assembly Hall (대형 강의실의 실내 열환경 실측 및 컴퓨터시뮬레이션 비교 연구)

  • Yoon, JaeOck
    • KIEAE Journal
    • /
    • v.4 no.3
    • /
    • pp.179-186
    • /
    • 2004
  • The evaluation of the indoor environment of the Assembly Hall in the University, which is designed to be a large space, requires efficient design of its heating system that takes into consideration natural convection and the characteristics of the occupant's spaces. Indoor thermal environment was measured in the field and simulated with CFD code. The estimations of temperature distribution and indoor airflow distribution must be carried out simultaneously, as the thermal stratification is induced by natural convection flows. In order to simulate the even distribution of factors affecting the indoor environment, including temperature and airflow, Phoenics is used. The turbulent flow model adopted is the RNG k- model. The inlets and outlets of the air-conditioning systems, material and thermal properties, and the size of the test room ($35m{\times}18m{\times}10m$) are used for the simulation. Since the Assembly Hall is symmetric, half of the space is simulated. A Cartesian grid is used for calculation and the number of grids are respectively $60{\times}45{\times}35$. The results of the computer simulation during winter conditions are compared with the measurements at the typical points in the assembly hall with the heating system. After evaluating the results of the computer simulations, the methods of the heating system and layout are suggested.

Effectiveness Assessment on the Soil Temperature of KMA as Ground Heat Source Using CFD in Pit Area (CFD를 이용한 기상청 지중온도의 피트부분 지중열원 유용성 평가에 관한 연구)

  • Min, Joon Ki;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.8 no.5
    • /
    • pp.49-54
    • /
    • 2008
  • The experimental of temperature, humidity and velocity was taken from the underground pit which utilized the system of ground heat source quite similar to the cool-pit system. Also, through CFD analysis, one could review the effectiveness of analysis of future alternatives. Furthermore, the temperature range of mock up cool-pit system was analyzed by inputting the weather data of annual average soil temperature provided by KMA(Korea Meteorological Administration) into the fluid simulation of anticipated heat distribution. Firstly, the difference between the temperature of air exhaust of the pit or the temperature of air supply of the compressor room and the experimental data for the month of May from the CFD analysis came out to be $0.6^{\circ}C$ and $0.9^{\circ}C$ respectively with tolerance of 3.1% and 4.7%. Secondly, the difference between the temperature of air exhaust of the Pit or the temperature of air supply of the compressor room and the experimental data for the month of July from the CFD analysis came out to be $0.8^{\circ}C$ and $1.1^{\circ}C$ respectively with tolerance of 3.3% and 4.5%. Thirdly, for the month of May, the difference between the experimental data taken for the air exhaust of the Pit or the air supply of the compressor room and soil temperature provided by KMA for monthly and yearly average temperature of Jeonju region came out be $1.9^{\circ}C$ and $1.8^{\circ}C$ respectively with tolerance of 10.7% and 9.8%. Fourthly, for the month of July, the difference between the experimental data taken for the air exhaust of the Pit or the air supply of the compressor room and soil temperature provided by KMA for monthly and yearly average temperature of Jeonju region came out be $1.1^{\circ}C$ and $1.4^{\circ}C$ respectively with tolerance of 4.5% and 5.8%. The result of above experiments allowed us to establish CFD model set up as a verification tool that is based on experimental data collected within the Pit area. Also, one could confirm the possibility to apply weather data of soil temperature provided by KMA in order to anticipate proper value for CFD analysis.

Stress distribution of near the interface on high temperature fatigue in ceramic/metal bonded joints (세라믹/금속접합재의 고온피로에 따른 접합계면의 응력분포)

  • 박영철;허선철;윤두표;김광영
    • Journal of Ocean Engineering and Technology
    • /
    • v.10 no.2
    • /
    • pp.106-119
    • /
    • 1996
  • The ceramic has various high mechanical properties such as heat, abrasion, corrosion resistance and high temperature strength compared with metal. It also has low speciffic weight, low thermal expansibillity, low thermal conductivity. However, it could not be used as structural material since it is brittle and difficult for the machining. Therefore, there have been many researches to attempt to join ceramic with metal which is full of ductillity in order to compensate the weakness of ceramic.The problem is that residual stress develops around the joint area while the ceramic/metal joint material is cooled from high joining temperature to room temperature due to remarkable difference of thermal expansion coefficients between ceramic and metal. Especially, the residual stress at both edges of the specimen reduces the strngth of joint to a large amount by forming a singular stress field. In this study, two dimensional finite element method is attempted for the thermal elastic analysis. The joint residual stress of ceramic/metal developed in the cooling process is investigated and the change of joint residual stress resulted from the repetitive heat cycle is also examined. In addition, it is attempted to clarify the joint stress distribution of the case of tensile load and of the case of superposition of residual stress and actual loading stress.

  • PDF

A Numerical Study on the Fire Behavior Phenomena in a Special Fire Protection Compartment (특수 방호공간에서 가상화재의 발생으로 인한 화재거동에 관한 수치적 연구)

  • Kim, Tae-Kuk;Son, Bong-Sei
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.1 no.1 s.1
    • /
    • pp.157-163
    • /
    • 2001
  • The objective of the present study is to predict the characteristics of the fire and smoke propagations in a clean room. Numerical calculations have been performed by using the finite volume method to obtain temperature and velocity distributions in the clean room. In odor to account for the turbulent flow characteristics, the standard $k-{\varepsilon}$ model is used. From this study, it was found that the fire propagation could be fully developed only after 150 seconds when the ventilation system in the clean room was off. And the smoke mass fraction showed a similar distribution as the gas temperature. Since the simulated fire was proceeded up to $20{\sim}30%$ of the room within 60 seconds. it could be recommended that the occupants should be evacuated from the room within 30 seconds.

  • PDF

Low Temperature Test of HWR Cryomodule

  • Kim, Heetae;Kim, Youngkwon;Lee, Min Ki;Park, Gunn-Tae;Kim, Wookang
    • Applied Science and Convergence Technology
    • /
    • v.25 no.3
    • /
    • pp.47-50
    • /
    • 2016
  • Low temperature test for half-wave resonator (HWR) cryomodule is performed at the superfluid helium temperature of 2 K. The effective temperature is defined for non-uniform temperature distribution. Helium leak detection techniques are introduced for cryogenic system. Experimental set up is shown to make the low temperature test for the HWR cryomodule. The cooldown procedure of the HWR cryomodule is shown from room temperature to 2 K. The cryomodules is precooled with liquid nitrogen and then liquid helium is supplied to the helium reservoirs and cavities. The pressure of cavity and chamber are monitored as a function of time. The vacuum pressure of the cryomodule is not increased at 2 K, which shows leak-tight in the superfluid helium environment. Static heat load is also measured for the cryomodule at 2.5 K.

Prediction of Airflow and Temperature Field in a Room With Convective Heat Source (열원이 존재하는 작업장내 기류 및 온도장 예측)

  • Jung, Yu-Jin;Ha, Hyun-Chul;Kim, Tae-Hyeung;Yoo, Guen-Jong
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.11 no.1
    • /
    • pp.78-84
    • /
    • 2001
  • A CFD simulation of airflow and temperature field in a heated room has been described in this paper. The thermal wall jet created by a radiator greatly influences the airflow pattern, temperature distribution. The area close La a heat source has a higher risk of air-borne contamination and imposes a harmful effect on occupants in that area. The predicted flow field, temperature results show good agreement with the measured data. As the results were compared with experimental data, the applicability of CFD was satisfactorily verified. Also, the CFD simulation can capture the natural convective flow features. If a CFD simulation is applied ventilation design with a heat source, An effective design will be attained. Further study is required to improve the accuracy of CFD simulation.

  • PDF

The Study for Evaluation of Thermal Comfort in Passenger Cabin on Cruise Ship (크루즈선 객실의 공조 쾌적성 평가에 관한 연구)

  • Koo, Keun-Hae;Lee, Ho-Ki;Choi, Jae-Woong;Lee, Jae-Keun
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.48 no.1
    • /
    • pp.62-66
    • /
    • 2011
  • The present work focuses on the evaluation of thermal comfort in passenger cabin of a cruise ship. A computational fluid dynamics (CFD(Airpak)) is used to calculate air velocity and temperature distribution in the passenger cabin as well as PMV and PPD. The CFD is used to simulate two different cases, room unit system and wardrobe duct system. Both of cases are simulated in summer environment condition. The room unit system and wardrobe duct system are compared and evaluated by ISO 7730 thermal comfort categories. The performance of room unit system is shown to be more effective for this typical case of passenger cabin.