• Title/Summary/Keyword: Room-temperature distribution

Search Result 420, Processing Time 0.023 seconds

Local transport properties of coated conductors by laser-scan imaging methods

  • Kim, Gracia;Jo, William;Nam, Dahyun;Cheong, Hyeonsik;Moon, Seoung Hyun
    • Progress in Superconductivity and Cryogenics
    • /
    • v.18 no.2
    • /
    • pp.1-4
    • /
    • 2016
  • To observe the superconducting current and structural properties of high critical temperature ($T_c$) superconductors (HTS), we suggest the following imaging methods: Room temperature imaging (RTI) through thermal heating, low-temperature bolometric microscopy (LTBM) and Raman scattering imaging. RTI and LTBM images visualize thermal-electric voltages as different thermal gradients at room temperature (RT) and superconducting current dissipation at near-$T_c$, respectively. Using RTI, we can obtain structural information about the surface uniformity and positions of impurities. LTBM images show the flux flow in two dimensions as a function of the local critical currents. Raman imaging is transformed from Raman survey spectra in particular areas, and the Raman vibration modes can be combined. Raman imaging can quantify the vibration modes of the areas. Therefore, we demonstrate the spatial transport properties of superconducting materials by combining the results. In addition, this enables visualization of the effect of current flow on the distribution of impurities in a uniform superconducting crystalline material. These imaging methods facilitate direct examination of the local properties of superconducting materials and wires.

Optimal Design for Indoor Thermal Environment based on CFD Simulation and Genetic Algorithms (CFD 연성해석과 유전자 알고리즘을 이용한 실내 열환경 최적설계에 관한 연구)

  • 김태연;이윤규
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.2
    • /
    • pp.111-120
    • /
    • 2004
  • The optimal design method of indoor thermal environment using CFD coupled simulation and genetic algorithms (GA) is developed in this study. CFD could analyze the thermal environment considering the distribution of temperature, velocity, etc. in a room. Therefore, It would be appropriate to use CFD for the optimal design method considering their distribution. In this paper, the optimal design means the most appropriate boundary conditions of the room among the conditions where the design target of indoor therm environment is achieved. Two step optimal indoor thermal environment design method is proposed. It includes the GA for searching the optimal indoor thermal environment design. To examine the performance of this method, the optimal design of hybrid ventilation system, which uses the natural cross ventilation and the radiation-cooling panel is conducted. The optimal design which satisfies the design target (thermal comfort, minimum cooling load, minimum vertical temperature difference) is found using two step optimal design method.

Analysis of Temperature Distributions in Spray Coating Room (스프레이 코팅 룸의 온도분포 해석)

  • Kim, Nam Woong;Kim, Sung-Yong;Kim, Kug Weon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.11
    • /
    • pp.7667-7671
    • /
    • 2015
  • Recently, Zinc coating is often used with environment friendly features and high performance. Generally The coating temperature is one of main factors for determining coating thickness and coating ability, so the optimal coating temperature is strongly required. In this paper, the thermo-flow simulation considering the air flow inside the coating rooms for analyzing the temperature distributions of Zinc spray coating room was performed. Two spray coating rooms, preheating room and drying room were all modeled by SolidWorks program and the temperature distributions were analyzed by Flow simulation program. The analysis results were verified with the measured data by thermal image camera. The characteristics of temperature distributions of the first spray room and the second spray room were understood and the results showed that the temperatures of two spray coating room were low compared with the target temperature $25^{\circ}C$. To the exclusion of heater addition, the simulation with all the same conditions exclusive the exhaust fan was performed, which showed that the temperatures of the first and the second spray rooms increased by $6.2^{\circ}C$ and $5.8^{\circ}C$. This analysis can be applicable for designing a new spray coating room for improving performance.

Studies on the Flame Temperature Measurement of the Propagating Flame (전파화염에서의 화염온도측정에 관한 연구)

  • ;;Jeung, In Seuck
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.1 no.4
    • /
    • pp.182-189
    • /
    • 1977
  • The propagating flame temperature of the Propane-Air premixture by using 30.$\mu$ and 50.$\mu$ diameter platinum sensing wires, that is, Two Wires Correction Method, Through the constant volume burining inside the 150mm diameter, 30mm height combustion chamber under the circumstances of the atomospheric pressure, and the room temperature was determined. Also the temperature distribution across High Temperature Region, i.e. Flame Front, and the temperature profile behind the flame the front have been obtained.

Experimental Study on Heat Flow According to the Wind Velocity in an Underground Life Space (지하생활공간 화재시 풍속에 따른 열유동 특성 연구)

  • Kim, Young-No;Suk, Chang-Mok;Kim, Wha-Jung
    • Fire Science and Engineering
    • /
    • v.21 no.3
    • /
    • pp.61-68
    • /
    • 2007
  • The purpose of this study analyzes heat flows and fire behavior through a reduced-scale model experiments about change of wind velocity in underground life space. When the wind velocity is increased the temperature rise time of the fire room was risen fast. And temperature of fire room was increased. And increase of wind velocity displayed maximum temperature at an opening of the fire room. Heat flows by fire spread increase size of smoke occurrence and flame, and displayed high temperature distribution in passageway than inside of neighborhood department promoting eddy flow spread as wind velocity increases. Finally, heat flows are decided by wind and wind velocity at fire of underground life space, and Wind velocity increases, temperature increase and decrease could confirm that is gone fast.

A Study on the Flame Temperature Measurement of the Transiently Propagating Flame by using Platinum-Hot-Wire-Resistance-Thermometry (열선백금저항선을 이용한 과도적 전파화염의 화염온도측정에 관한 연구)

  • 정인석;조경국;황상순
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.7 no.3
    • /
    • pp.94-101
    • /
    • 1985
  • The flame temperature of LPG-air premixture flame was measured by extrapolation of limiting case corresponding to the infinitely thin diameter of Platinum-resistance-hot-wire. LPG-air premixture flame, initially under atmospheric pressure and room temperature, propagates downward from top of the model combustion chamber maintained at constant pressure through the whole combustion process. Analytical calculation technique was also applied to determine full temperature history or spatial temperature distribution from flame reaction zone to burnt gas region.

  • PDF

Reduction of Drawing Process in Warm Forming Steel Sheets using Oil Pan (온간성형공법을 이용한 오일팬 드로잉공정 단축)

  • 최이천
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1999.03b
    • /
    • pp.88-94
    • /
    • 1999
  • This study is to investigate the effects of warm deep drawing with steel sheets of SCP3C and SCP1 for improving deep drawability. Experiments were carried out in various working conditions such as forming temperature and lubricantion. The effect of lubricantion and temperature on drawabillity of steel sheets as well as thickness distribution of drawn oil pan were examined and discussed. One step forming at room temperature and uniform distribution of thickness was achieved at optimum formability for lubricantion. The optimum forming temperature was obtained that both the die and the blankholder were heated to 10$0^{\circ}C$ while the punch was cooled by circulating coolant of $0^{\circ}C$.

  • PDF

Kinetics of Athermal Martensitic Transformation in Yttria Doped Zirconia

  • Pee, Jae-Hwan;Choi, Eui-Seok;Hayakawa, Motozo
    • Journal of the Korean Ceramic Society
    • /
    • v.42 no.11 s.282
    • /
    • pp.718-721
    • /
    • 2005
  • The high temperature tetragonal phase of zirconia containing $1.40{\~}1.60\;mol\%$ of yttria can be fully retained at room temperature by rapid cooling. The metastable tetragonal phase transforms into the monoclinic phase athermally upon subzero cooling. The transformation exhibited an athermal burst transformation. The effects of yttria content and grain size on the athermal martensitic transformation were studied in detail. The burst temperature linearly decreased with increasing yttria content or decreasing grain size. To consider the distribution of martensite nuclei, the Weibull modulus of the athermal martensitic transformation was evaluated from the distribution of the burst transformation temperature. From the Weibull analysis, the distribution of embryos appears to be more homogeneous than that of the defects responsible for the fracture of similar material.

Determination of the Harvest Date and Ripening Phase of 'Seolhyang' Strawberry (시설재배된 설향딸기의 수확시기가 수확후 품질에 미치는 영향)

  • Hong, Sae Jin;Eum, Hyang Lan
    • Journal of Bio-Environment Control
    • /
    • v.29 no.1
    • /
    • pp.62-72
    • /
    • 2020
  • The purpose of this study was to investigate the quality characteristics of ripe fruit based on harvest date and to examine the ripening phase of 'Seolhyang' strawberry suitable for room temperature, cold-chain, and low temperature distribution. The strawberries were harvested six times between December 20 to May 9. The appropriate maturity of strawberries is characterized by the firmness of approximately 2.9-3.0 N, and SSC remained above 8.6 °Brix until March and declined after April. The quality index values that determine the maturity stage of strawberries should be red color, Hunter a value ranging from 32 to 37, and hue angle of 36-45℃. For the after-ripening experiment, the progression rate of the ripening stage determined based on strawberry color was 10%/day at room temperature, 5%/day at 10-12℃, and 3%/day at 5℃. Thus, strawberries should be harvested at 80% coloring stage for distribution at room temperature and at least 90% for low temperature storage to maintain the merchantability. Besides, strawberries harvested at 70% coloring stage at room temperature and strawberries harvested below 80% coloring stage at low temperatures below 5℃ had lost commercial value before reaching 100% coloring stage.