• Title/Summary/Keyword: Room temperature spray

Search Result 119, Processing Time 0.027 seconds

STUDY OF CORRELATION BETWEEN WETTED FUEL FOOTPRINTS ON COMBUSTION CHAMBER WALLS AND UBHC IN ENGINE START PROCESSES

  • KIM H.;YOON S.;LAI M.-C.
    • International Journal of Automotive Technology
    • /
    • v.6 no.5
    • /
    • pp.437-444
    • /
    • 2005
  • Unburned hydrocarbon (UBHC) emissions from gasoline engines remain a primary engineering research and development concern due to stricter emission regulations. Gasoline engines produce more UBHC emissions during cold start and warm-up than during any other stage of operation, because of insufficient fuel-air mixing, particularly in view of the additional fuel enrichment used for early starting. Impingement of fuel droplets on the cylinder wall is a major source of UBHC and a concern for oil dilution. This paper describes an experimental study that was carried out to investigate the distribution and 'footprint' of fuel droplets impinging on the cylinder wall during the intake stroke under engine starting conditions. Injectors having different targeting and atomization characteristics were used in a 4-Valve engine with optical access to the intake port and combustion chamber. The spray and targeting performance were characterized using high-speed visualization and Phase Doppler Interferometry techniques. The fuel droplets impinging on the port, cylinder wall and piston top were characterized using a color imaging technique during simulated engine start-up from room temperature. Highly absorbent filter paper was placed around the circumference of the cylinder liner and on the piston top to collect fuel droplets during the intake strokes. A small amount of colored dye, which dissolves completely in gasoline, was used as the tracer. Color density on the paper, which is correlated with the amount of fuel deposited and its distribution on the cylinder wall, was measured using image analysis. The results show that by comparing the locations of the wetted footprints and their color intensities, the influence of fuel injection and engine conditions can be qualitatively and quantitatively examined. Fast FID measurements of UBHC were also performed on the engine for correlation to the mixture formation results.

Preparation and Characterization of Pamidronate-loaded PLGA Wafer for the Treatment of Bone Resorption (골 재흡수 치료를 위한 파미드로네이트를 함유한 이식형 생분해성 PLGA 웨이퍼의 제조와 특성결정)

  • 유제영;김상욱;강길선;성하수;정제교
    • Polymer(Korea)
    • /
    • v.26 no.5
    • /
    • pp.680-690
    • /
    • 2002
  • Implantable biodegradable wafers were prepared with pamidronate -loaded poly (L-lactide-co-glycolide) (PLGA, 75 : 25 mole ratio by lactide to glycolide, molecular weight : 20000 and 90000 g/mole) by direct compression method for the sustained release of pamidronate to investigate the possibility for the treatment of bone resorption. Pamidronate-loaded PLGA powders were prepared by means of physical mixing and spray drying with the control of formulation factors and characterized by scanning electron microscope and X-ray diffractometer. The pamidronate-loaded PLGA powders fabricated into wafers by direct compression under the constant pressure and time at room temperature. These wafers were also observed for their structural characteristic, release pattern, and degradation pattern. The release rate of pamidronate increased with increasing their initial loading ratio as well as increasing wafer thickness. The molecular weight of PLGA affects the release pattern : the higher molecular weight of PLGA, the faster release rate. It can be explained that the higher viscosity of high molecular PLGA solution at same concentration tends to aggregate PLGA and pamidronate resulting in unstable pharmaceutical dosage form. This system had advantages in terms of simplicity in design and obviousness of drug release rate and nay be useful as an implantable dosage form for the treatment of aural cholesteatoma.

Quality Characterization of Salmon Oil Microencapsulated with Various Wall Materials (다양한 피복물질을 이용한 연어 오일의 미세캡슐화 및 품질 특성)

  • LIM, Hyun-Jung;PARK, Seul-Ki;KIM, Min-Jeong;LEE, Won-Kyung;MIN, Jin-Ki;CHO, Young-Je
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.27 no.5
    • /
    • pp.1334-1342
    • /
    • 2015
  • The aim of this study was to investigate the quality characterization of salmon oil microencapsulated with maltodextrin (MD), cyclodextrin (CD), sodium caseinate (SC), arabic gum (AG) and WPI. After spray drying to ambient temperature, the salmon oil powders were packed (single package) and placed at room temperature ($25^{\circ}C$) for 30 day. The quality characterization of salmon oil powder including total oil (%), extractable oil (%), encapsulation efficiency (%), fatty acid, SEM, pH, acid value (AV), peroxide value(POV) were investigated. Salmon oil was microencapsulated with a high power yield (> 80%); including the formulation MD/SC and MD/SC/WPI. The microencapsules of MD/SC/WPI presented spherical shapes, smooth texture and non-porous surfaces. The pH of MD/SC/WPI varied from 6.11 to 5.99 (p>0.05). The AV of MD/SC/WPI varied from 4.74 to 4.61 (p>0.05). The pH and AV were not significantly different. The POV of MD/SC/WPI increased with storage day (p<0.05). It was concluded that MD/SC/WPI could delay lipid oxidation and high yield (82.55%) of salmon oil powder.

Effects of Change in Heat Release Rate on Unsteady Fire Characteristics in a Semi-Closed Compartment (반밀폐된 구획에서 발열량 변화에 따른 비정상 화재특성)

  • Hwang, Cheol-Hong
    • Fire Science and Engineering
    • /
    • v.26 no.2
    • /
    • pp.75-83
    • /
    • 2012
  • An experimental study was conducted to investigate the effects of change in heat release rate on unsteady fire characteristics of under-ventilated fire in a semi-closed compartment. A standard doorway width of the full-scale ISO 9705 room was modified to 0.1 m and the flow rate of heptane fuel was increased linearly with time using a spray nozzle located at the center of enclosure. Temperature, heat flux, species concentrations and heat release rate were continuously measured and then global equivalence ratio (GER) concept was adopted to represent the unsteady thermal and chemical characteristics inside the compartment. It was observed that there was a significant difference in unsteady behavior between global and local combustion efficiency, and the GERs predicted by ideal and measured heat release rate were also shown different results in time. The unsteady behaviors of temperature, heat flux and species concentrations were represented well using the GER concept. It was important to note that CO concentration was gradually decreased with the increase in GER after reaching its maximum value in the range of 2.0~3.0 of global equivalence ratio. In addition, the experimental data on unsteady thermal and chemical behaviors obtained in a semi-closed compartment will be usefully used to validate a realistic fire simulation.

Efficiency Test for Surface Protecting Agents for the Chemical Resistance of Concrete Structures Using Sulfur Polymers (Sulfur Polymer를 사용한 콘크리트 구조물용 내화학성 표면보호재의 성능 평가)

  • Lee, Byung-Jae;Lee, Eue-Sung;Chung, Woo-Jung;Kim, Yun-Yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.5
    • /
    • pp.1-8
    • /
    • 2014
  • Structures requiring chemical resistance are usually coated with surface protecting agents, but the cost for maintenance and re-construction is incurred due to the low durability. Therefore, in this study, sulfur was polymerized and the performance was examined so that it could be used as the concrete surface protecting agents for structures requiring chemical resistance. The evaluation results indicated that for the spray of the sulfur polymer surface coating agents, the application of the gravity type was appropriate; and for the number of coating times, about 3 cycle spray gave the best results. For the surface condition of the concrete to be coated with the surface protecting agents, outstanding quality was obtained above room temperature ($20{\sim}30^{\circ}C$), and the bond strength increased as the temperature increased. The evaluation results of the strength characteristics depending on the filler content of the surface protecting agents indicated that about 20~40% filler mixing contributed to the strength improvement as it reduced the shrinkage of the sulfur polymer. Also, the mixing of silica showed larger increase in the bond strength than the mixing of fly ash, and the most outstanding bond strength characteristics could be obtained by the mixing of both silica and fly ash. In the case of the chemical resistance, the strength reduction was minimized and outstanding chemical resistance was obtained when the fly ash and silica were substituted by 20%, respectively. The performance evaluation of the chloride ion penetration indicated that for the specimens coated with the sulfur polymer surface protecting agents, the chloride ion penetration resistance increased by 29~48% compared to the specimen without the coating of the surface protecting agent. The examination of the coating condition of the surface protecting agents, compressive strength, bond strength, chemical resistance, and salt damage resistance indicated that in the range of this study, the optimal level was when the silica and fly ash were substituted by 20%, respectively, as the filler for the sulfur polymer.

A Research on Thermal Properties & Fire Resistance of A Water Film Covered Glazing System for Large Atrium Space (대규모 아트리움에 적용되는 수박형성 유리벽의 열적 특성 및 내화성능에 관한 연구)

  • 박형주;지남용
    • Fire Science and Engineering
    • /
    • v.13 no.4
    • /
    • pp.38-55
    • /
    • 1999
  • In order practically to use fire-defective glazing materials for the compartment wall where a fire-protection rating is mandated, there have been many trials internationally, This research focuses on a feasibility that, if certain water film covered all surface of glass, the glazing system can endure without breaking out under the compartment fire. First of all, a water film spray system was specially designed to wet the entire surface of the glass and also to have tiny small amount of water rebounded from the surface after emitted from nozzles. After this system has proven to have perfect performance, small-scale tests were done to find out if the water film covered glazing system react to the high temperature curve in a small furnace room. Finally, on basis of the obtained data, full-scale experiments were done so that water-film covered glazing system can pass the Korean Standard (KS) test for fire resistance, KS F2257.

  • PDF

Persistence and Dislodgeable Residues of Chlorpyrifos and Procymidone in Lettuce Leaves under Greenhouse Condition (상추의 생산단계별 Chlorpyrifos 및 Procymidone의 잔류허용기준 설정)

  • Kim, Young-Sook;Park, Ju-Hwang;Park, Jong-Woo;Lee, Young-Deuk;Lee, Kyu-Seung;Kim, Jang-Eok
    • Korean Journal of Environmental Agriculture
    • /
    • v.21 no.2
    • /
    • pp.149-155
    • /
    • 2002
  • Two pesticides commonly used for lettuce cultivation including chlorpyrifos and procymidone were subjected to a field residue trial to ensure safety of terminal residues in the harvest. After pesticides were applied at standard and double rates in a foliar spray, leaf persistence of their residues was investigated far 10 days prior to harvest. Even though far exceeded the tolerances, initial leaf residues were rapidly dissipated with time and remained only 0.4$\sim$7.2% of the residues in the harvest. As well fitted by the first-order kinetics, biological half-lives of the pesticide residues in lettuce leaves ranged 1.2$\sim$2.6 days. Slow dissipation of the residues in the harvest was observed during storage at room temperature and 4$^{\circ}C$ for 7 days. Portions of dislodgeable residues which resided in detergent washings decreased as time elapsed. Patterns in dissipation and distribution of dislodgeable residues were not largely affected by the application rate of pesticides. It is concluded that timing of pesticide application, that is, pre-harvest interval would be the first factor to determine the terminal residue level in edible portions of lettuce.

Studies on the Nature and Pathogenicity of Nuclear Polyhedrosis Virus of the Fall Webworm, Hyphantria cunea (Drury) (흰불나방 핵다각체병바이러스의 성상과 병원성에 관한 연구)

  • Im Dae Joon;Hyun Jae Sun;Paik Woon Hah;Lim Jong Sung
    • Korean journal of applied entomology
    • /
    • v.18 no.1 s.38
    • /
    • pp.1-10
    • /
    • 1979
  • An inclusion forming virus isolated from a fan webworm, Hyphantria cunea, in 1975 was identified as a nuclear polyhedrosis virus. With the virus isolated in Korea, it was considered that the virus would be one of the valuable microorganism in microbial control. In this connection, 1) the shape and size of the virus for identification, 2) susceptibility of the various instar larvae to the virus, 3) the effects of storage condition on the pathogenicity and the cross infection of the virus to the larvae of Bombyx mori were examined. The results are summarized as follows; 1. The polyhedron was tetrahedron or hexahedron of $2\mu$ in size and the rod-shaped virus particles consisting of $2\~14$ rods in a bundle were $330m{\mu}\times35m{\mu}$ in size. 2. The hexagonal nuclear polyhedra were found only in the nucleus of the midgut cells but were variable in size. 3. The $LD_{50}$ values for the various instar larvae of H. cunea were $8.377\times10^4\;PIBs/ml$ for the second, $4.974\times10^5\;PIBs/ml$ for the fifth instar larvae. The $LT_{50}values$ for $10^6\;PIBs/ml$ were 9.6 days for the second, 11.5 days for the third, 12.0 days for the fourth and 17 days for the fifth instar larvae. 4. The susceptibility of H. cunea to the nuclear polyhedrosis virus was greater in the first generation than in the second generation. 5. The effect of the storage conditions on the pathogenicity of the nuclear polyhedra was less in refrigerator $(5^{\circ}C)$ and in freezing $(-80^{\circ}C)$ than in room temperature $(18.5^{\circ}C)$, especially as air-dried polyhedra than as suspension. The pathogenicity of the polyhedra seemed to decrease by sunlight during storage as cadavers, since rather greater decrease in pathogenicity was found in sunny condition than in shady condition. 6. The effective spray concentration was $6.4\times10^7\;PIBs/ml$ in the field and its $LT_50$ values for the third and the fifth instar larvae were 4.8 days and 14.2 days, respectively. 7. No cross infections were found in the nuclear polyhedrosis virus between H. cunea and B. mori. larvae.

  • PDF

무령왕릉보존에 있어서의 지질공학적 고찰

  • 서만철;최석원;구민호
    • Proceedings of the KSEEG Conference
    • /
    • 2001.05b
    • /
    • pp.42-63
    • /
    • 2001
  • The detail survey on the Songsanri tomb site including the Muryong royal tomb was carried out during the period from May 1 , 1996 to April 30, 1997. A quantitative analysis was tried to find changes of tomb itself since the excavation. Main subjects of the survey are to find out the cause of infiltration of rain water and groundwater into the tomb and the tomb site, monitoring of the movement of tomb structure and safety, removal method of the algae inside the tomb, and air controlling system to solve high humidity condition and dew inside the tomb. For these purposes, detail survery inside and outside the tombs using a electronic distance meter and small airplane, monitoring of temperature and humidity, geophysical exploration including electrical resistivity, geomagnetic, gravity and georadar methods, drilling, measurement of physical and chemical properties of drill core and measurement of groundwater permeability were conducted. We found that the center of the subsurface tomb and the center of soil mound on ground are different 4.5 meter and 5 meter for the 5th tomb and 7th tomb, respectively. The fact has caused unequal stress on the tomb structure. In the 7th tomb (the Muryong royal tomb), 435 bricks were broken out of 6025 bricks in 1972, but 1072 bricks are broken in 1996. The break rate has been increased about 250% for just 24 years. The break rate increased about 290% in the 6th tomb. The situation in 1996 is the result for just 24 years while the situation in 1972 was the result for about 1450 years. Status of breaking of bircks represents that a severe problem is undergoing. The eastern wall of the Muryong royal tomb is moving toward inside the tomb with the rate of 2.95 mm/myr in rainy season and 1.52 mm/myr in dry season. The frontal wall shows biggest movement in the 7th tomb having a rate of 2.05 mm/myr toward the passage way. The 6th tomb shows biggest movement among the three tombs having the rate of 7.44mm/myr and 3.61mm/myr toward east for the high break rate of bricks in the 6th tomb. Georadar section of the shallow soil layer represents several faults in the top soil layer of the 5th tomb and 7th tomb. Raninwater flew through faults tnto the tomb and nearby ground and high water content in nearby ground resulted in low resistance and high humidity inside tombs. High humidity inside tomb made a good condition for algae living with high temperature and moderate light source. The 6th tomb is most severe situation and the 7th tomb is the second in terms of algae living. Artificial change of the tomb environment since the excavation, infiltration of rain water and groundwater into the tombsite and bad drainage system had resulted in dangerous status for the tomb structure. Main cause for many problems including breaking of bricks, movement of tomb walls and algae living is infiltration of rainwater and groundwater into the tomb site. Therefore, protection of the tomb site from high water content should be carried out at first. Waterproofing method includes a cover system over the tomvsith using geotextile, clay layer and geomembrane and a deep trench which is 2 meter down to the base of the 5th tomb at the north of the tomv site. Decrease and balancing of soil weight above the tomb are also needed for the sfety of tomb structures. For the algae living inside tombs, we recommend to spray K101 which developed in this study on the surface of wall and then, exposure to ultraviolet light sources for 24 hours. Air controlling system should be changed to a constant temperature and humidity system for the 6th tomb and the 7th tomb. It seems to much better to place the system at frontal room and to ciculate cold air inside tombs to solve dew problem. Above mentioned preservation methods are suggested to give least changes to tomb site and to solve the most fundmental problems. Repairing should be planned in order and some special cares are needed for the safety of tombs in reparing work. Finally, a monitoring system measuring tilting of tomb walls, water content, groundwater level, temperature and humidity is required to monitor and to evaluate the repairing work.

  • PDF