• Title/Summary/Keyword: Room fire

Search Result 528, Processing Time 0.022 seconds

Finite Element Analysis and Material Characteristics of Fire Spray Nozzle for Ship Engine Room (선박 엔진룸의 소화용 분무노즐의 재료특성 및 유동해석)

  • Bae, Dong-Su;Lee, Jin-Kyung
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.22 no.5
    • /
    • pp.553-559
    • /
    • 2019
  • Various types of nozzles have been used to cope with fire in ships. However, in Korea, precise nozzles that perform fine spraying function are required for fire fighting in case of fire in a ship, and most of these nozzles depend on imports. Therefore, in this study, we developed various types of nozzles to develop the water spray nozzle for evolving fire in the engine room of the ship, and developed an optimal nozzle through flow analysis and fire test. For this purpose, we selected the materials that can satisfy the characteristics of existing nozzle materials and developed the design technology and processing technology in the nozzle considering fluid flow to achieve optimal water spraying performance. In order to develop an optimal nozzle, the flow through the finite element analysis was first analyzed and the nozzle was manufactured. As a result of flow analysis of the developed nozzle, the maximum velocity at the outlets of four holes at 0.3 MPa was about 3m/s and about 0.15 MPa. In addition, when the pressure at the inlet was 1.8 MPa, it showed the outlet speed of about 18m/s and a pressure of 1.2 MPa.

Numerical Analysis on Flow Characteristics in the Pressurized Air Supply Smoke Control System (급기가압 제연설비의 내부 유동특성에 대한 수치해석)

  • Ko, Gwon-Hyun
    • Fire Science and Engineering
    • /
    • v.31 no.4
    • /
    • pp.52-58
    • /
    • 2017
  • This study investigated the pressure difference distribution and the flow characteristics among room, ancillary room, and stair case by carrying out the numerical simulations on the air flow inside the pressurized air supply smoke control system. Numerical simulations were conducted to analyze pressure and velocity distribution of compartments by pressurized air supply for the air-leakage test facility which was built to measure the effective leakage area. In this study, the leakage of air was considered by locating the narrow slit onto fire door and window of room. Simulated results using this method precisely followed the previous experimental results for the pressure differences between the stair case and ancillary room. Predicted results showed that the local leakage of air rarely affected the overall flow pattern and pressure distribution. Although the average velocity over the door between room and ancillary room satisfied the regulation for fire safety, it was certified the unsafe outflow to ancillary room could be occurred in the local position such as the upper part of the door.

Numerical Study on Air Egress Velocity of Ancillary Room Pressurization Systems in Apartment Fires (공동주택 화재 시 부속실 가압 시스템의 방연풍속에 관한 수치해석적 연구)

  • Kim, Byeongjun;Yang, Ying;Shin, Weon Gyu
    • Fire Science and Engineering
    • /
    • v.34 no.4
    • /
    • pp.78-86
    • /
    • 2020
  • In this study, numerical simulations were performed on the air egress velocity of pressurization systems in an ancillary room when a fire occurred in an apartment house. The relationship between the air supply flow rate of a damper and air egress velocity at a fire door is predicted to be linear. Additionally, a minimum flow rate of the damper, which meets national fire safety standards for air egress velocity, i.e., 0.7 m/s can be estimated. Air egress velocity at the fire door is analyzed according to the supply air direction and installation height of the damper. When the damper has an upward supply air direction and is installed at a high level, the egress velocity at the top section of the fire door is larger, whereas the soot concentration at the ancillary room is lower than when the supply direction of the damper is downward. Therefore, it is found that increasing the air egress velocity at the top section of the fire door helps to efficiently prevent the inflow of smoke.

Parameter Effects on the Time to Reach Flashover Conditions in Single Room Fires (건물화재의 플래시오버 도달 시간에 영향을 미치는 인자들에 관한 연구)

  • Kim, Hyeong-Jin;Lilley, David-G.;Baek, Byung-Joon;Pak, Bock-Choon
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1384-1388
    • /
    • 2003
  • In structural fires, flashover is characterized by the rapid transition in fire behavior from localized burning of fuel to the involvement of all combustibles in the enclosure. An investigation of parameter effects on the time to reach flashover conditions in a typical single room fire is undertaken using a zone method (FAST) and Thomas method. Major parameters affecting the time to reach flashover are found to be fire growth rate, ventilation opening area and internal room surface. The results of the FAST and the Thomas Method give very similar results of the time to reach flashover..

  • PDF

Experimental Study of the Blowoff Flame Phenomena Due to Changes of Balcony Length (발코니 길이변화에 의한 화염분출성상의 실험적 고찰)

  • Kim, Hoe-Cheon;Sohn, Jang-Yeul;Park, Hyung-Ju
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.3
    • /
    • pp.235-244
    • /
    • 2007
  • In the case of the fire outburst within a partitioned space, it can disappear inside it through smoldering process if the fire cannot obtain sufficient imflammability. On the contrary, if it obtains it, the fire is not restricted within the room, spreading to the higher levels beyond outside windows and the compartment room. The method to prevent the fire spread through windows is considered to build a balcony or equip with sprinkler facilities. This case study is to identify which effects and controlibility a balcony brings about on the spread of fire through a full scale model experiment. In order to understand the effects of fire spread on the upper levels of the room on fire by changing the length of balcony, the temperature was measured, radiant heat was investigated, and products of combustion were analyzed. The result showed that when fire occured, longer length of the balcony, which linked to the outside wall of the apartments, led to the blocking of the fire spread, lower level of radiant heat, and significantly less transfer of toxic gases, and the driving force of the outburst of flame was identified as the attractive force due to the turbulence of uncombusted gases, which exist on the upper level of the outbursting flame.

An Experimental Study on the Automobile Engine Room Fire Using the Extinguishing Agents (소화약제를 이용한 자동차 엔진룸 화재 실험에 관한 연구)

  • Han, Yong-Taek;Kim, Dong-Ho;Kwon, Sung-Pil
    • Fire Science and Engineering
    • /
    • v.28 no.4
    • /
    • pp.1-7
    • /
    • 2014
  • Several complex devices and equipments are installed in the car's engine room, including various kind of oils or other flammable materials. So re-ignition is very likely to take place in it. In addition, it is restrictive for the driver or the occupant to open the bonnet and to spray the fire extinguisher in the engine room due to the high possibility of explosion. Therefore, a fire extinguishing system, which can detect a fire and inject the fire extinguishing agent to extinguish it, and fire extinguishing agents including HFC-227ea, which can stand the high temperature within the engine room and hold the viscosity sufficient to keep it in the kind of foam, were developed and tested. And the suffocation effect and the cooling effect come from the fire extinguishing principle of the foam fire extinguishing agent and the inhibiter catalyst effect come from the one of HFC-227ea was led simultaneously, and fire extinguishing agents without the secondary damage caused by residuals after the fire extinguishment like a case of the powder fire extinguishing agent, were developed. And experiments using a vehicle collision after the discharge is complete, foreign material can be removed without extinguishing the advantage that experimental results obtained.

A Fire Hazard Assessment of Interior Finish Materials (건물 내장재의 화재위험성 평가 방법)

  • 김운형
    • Fire Science and Engineering
    • /
    • v.12 no.2
    • /
    • pp.17-28
    • /
    • 1998
  • To propose a new fire hazard assessment criteria of interior finish materials, the properties and incident heat flux of interior finish materials in a compartment fires are investigated and compared by using flame spread model developed by Quintiere. The properties considered on which fire growth depend are including flame heat flux and thermal inertia, lateral flame spread parameter, heat of combustion and effective heat flux and thermal inertia, lateral flame spread parameter, heat of combustion and effective heat of gasfication. ISO Room Corner Test(9705) is applied in the model and the time for total energy release rate to reach 1MW is examined. The results are compared for the 24 different materials tested by EUREFIC. Dimensionless parameter a, b and ${\gamma}$b are used to develope a new method in which fire hazard of interior finish materials can be classified resulting from correlation between b and flashover time. Results show that if b greater than about zero, flashover time in the ISO Room-Corner Test is principally proportional to ignition time only.

  • PDF