• 제목/요약/키워드: Room fire

검색결과 531건 처리시간 0.022초

Water-blocking Asphyxia of N95 Medical Respirator During Hot Environment Work Tasks With Whole-body Enclosed Anti-bioaerosol Suit

  • Jintuo Zhu;Qijun Jiang;Yuxuan Ye;Xinjian He;Jiang Shao;Xinyu Li;Xijie Zhao; Huan Xu;Qi Hu
    • Safety and Health at Work
    • /
    • 제14권4호
    • /
    • pp.457-466
    • /
    • 2023
  • Background: During hot environment work tasks with whole-body enclosed anti-bioaerosol suit, the combined effect of heavy sweating and exhaled hot humid air may cause the N95 medical respirator to saturate with water/sweat (i.e., water-blocking). Methods: 32 young male subjects with different body mass indexes (BMI) in whole-body protection (N95 medical respirator + one-piece protective suit + head covering + protective face screen + gloves + shoe covers) were asked to simulate waste collecting from each isolated room in a seven-story building at 27-28℃, and the weight, inhalation resistance (Rf), and aerosol penetration of the respirator before worn and after water-blocking were analyzed. Results: All subjects reported water-blocking asphyxia of the N95 respirators within 36-67 min of the task. When water-blocking occurred, the Rf and 10-200 nm total aerosol penetration (Pt) of the respirators reached up to 1270-1810 Pa and 17.3-23.3%, respectively, which were 10 and 8 times of that before wearing. The most penetration particle size of the respirators increased from 49-65 nm before worn to 115-154 nm under water-blocking condition, and the corresponding maximum size-dependent aerosol penetration increased from 2.5-3.5% to 20-27%. With the increase of BMI, the water-blocking occurrence time firstly increased then reduced, while the Rf, Pt, and absorbed water all increased significantly. Conclusions: This study reveals respirator water-blocking and its serious negative impacts on respiratory protection. When performing moderate-to-high-load tasks with whole-body protection in a hot environment, it is recommended that respirator be replaced with a new one at least every hour to avoid water-blocking asphyxia.

아두이노를 이용한 소규모 서버 룸 환경 모니터링 시스템의 설계 및 구현 (Design and Implementation of a Small Server Room Environment Monitoring System by Using the Arduino)

  • 이효승;오재철
    • 한국전자통신학회논문지
    • /
    • 제12권2호
    • /
    • pp.385-390
    • /
    • 2017
  • IT기술의 발달로 기업의 각종업무, 공장 자동화시스템, 병원 의료시스템 등 다양한 방면에서 전산화된 시스템을 도입하여 운영하고 있으며 시스템이 정지되었을 경우 모든 업무가 정지될 정도로 전산 시스템의 중요도는 그 어떠한 것보다 중요하다 할 수 있을 것이다. 이러한 상황에서 시스템의 정상 운영을 위해 서버실의 온도, 습도, 화재등과 같은 환경 관리에도 항상 신경을 써야 한다. 이러한 소규모 서버실 운영을 위해서는 담당자가 신경 쓰지 않는 상황에서 24시간 독자적으로 환경 모니터링을 하고 이벤트 발생 시 실시간으로 담당자에게 알려주는 저비용의 시스템이 필요하다고 생각되며 이러한 문제를 해결하기 위해 데몬 프로세스와 아두이노를 기반으로 한 장비의 연동 결과 담당자에게 실시간 환경 데이터를 제공하고 특정 이벤트 발생 시 그 이벤트에 대한 내용을 제공하여 그로인해 발생할 수 있는 문제 등을 미연에 방지 할 수 있을 것으로 기대한다.

$CO_2$소화제 노즐수에 따른 유동특성 및 소화제농도분포에 대한 연구 (A Study of the Characteristics of Flow and the Distribution of $CO_2$ Agent Concentration According to the Number of $CO_2$ Agent Nozzle)

  • 박찬수
    • 한국화재소방학회논문지
    • /
    • 제19권2호
    • /
    • pp.37-44
    • /
    • 2005
  • 가스계소화설비인 $CO_2$소화장치의 구성 중 $CO_2$노즐수에 따른 유동특성 및 $CO_2$소화제 농도분포를 분석하기 위하여 $CO_2$ 노즐수를 변화시키면서 전산모사실험을 3차원 비정상상태로 수행하였다. 실제 선박의 기관실을 방호공간으로 선정하여 유동장과 $CO_2$소화제 농도장을 계산하였다. $CO_2$소화제 노즐수를 2개에서 4개로 증가시킬 경우는 낮은 농도분포를 나타냈고, $CO_2$소화제 노즐수를 6개 이상으로 증가시킬 경우는 전 영역에 영향을 미치는 재순환 유동이 형성되었다. $CO_2$소화제 노즐수를 4개 이상 증가시킬 경우는 0.36이하의 등농도선대가 확장 또는 수축되었다. 따라서 $CO_2$ 소화장치 설계 시 적정한 소화제노즐수와 노즐배열을 고려해야 할 것으로 생각된다.

온도상승에 따른 배선용 차단기의 동작특성에 관한 연구 (A Study on the Operating Characteristics of Molded Case Circuit Breakers according to Temperature Rise)

  • 정다운;김재호
    • 한국안전학회지
    • /
    • 제30권5호
    • /
    • pp.8-13
    • /
    • 2015
  • Molded Case Circuit Breakers (MCCBs) are typically used to provide over current protection for electrical safety caused by short circuit faults and overloads in indoor low voltage power systems. The MCCB automatically connects and disconnects loads from the electrical source when the current reaches a value and duration that will cause an excessive. However, the MCCB sometimes is not interrupted due to a malfunction, nuisance tripping, or in a fire. Ensuring electrical safety is very important in a indoor low voltage power system. This paper presents the operating characteristics of MCCBs according to a temperature rise from room temperature to 160 degrees Celsius delivered by a radiant panel heater. The ABS 54c(rated current: 30A) of the hydraulic magnetic trip type was used in the experiments. The signals of temperature, voltage, and current were measured using the high accuracy Signal Conditioning Extensions for Instrumentation (SCXI) measurement system with the LabVIEW program manufactured by National Instruments. The operating characteristics were measured as functions of current amplitude and ramp-up rate. The MCCB tripping time decreased as a result of increasing current amplitude and ramp-up rate under a temperature rise condition, because the temperature and level of the current are directly proportional to the tripping time. Additionally, an instantaneous operation was observed after 8 times of the rated current, and the MCCB began to melt a surface temperature of around 300 degrees Celsius of. The experimental results coincided well with the operating curve.

온도 및 절연체에 따른 케이블의 단선시간 특성 해석 (Fusing Time Characteristics Analysis of Cable according to Temperature and Insulator)

  • 김주희;강신동;김재호
    • 한국안전학회지
    • /
    • 제33권5호
    • /
    • pp.15-20
    • /
    • 2018
  • This paper describes the fusing time characteristics of Light PVC Sheathed Circular Cord(VCTF) and Tray Frame Retardant(TFR) cables according to increased temperature under over current condition. The experimental equation will be used to determine the validity and reliability of the test results. The over current flowed 3, 5 and 10 times higher than the amount of allowable current using DC power supply with DAQ(Data Acquisition) measurement system. An infrared radiation heater, which was controlled by a variable AC auto transformer, was used to increase the temperature from room temperature to 50, 100 and 150 degrees Celsius. First, two type of cables were analyzed those with different cross-sectional areas with in the same structure and those with different structures with in the same cross-sectional areas. Then, it was determined how fusing time had been influenced according to the cross-sectional areas and different structures, respectively. The cable resistance was increased by joule heating according to increasing temperature. Therefore, the allowable current of cable is decreased. Finally, the fusing time of the cable was decreased due to increased temperatures at current flow, which were 3 times the amount of allowable current. The instantaneous breakdown was observed when current flow was 5 and 10 times over the amount of allowable current. The fusing time is directly affected by the structure of cable insulation.

전기 히터의 형상에 따른 시뮬레이션 열 해석 연구를 통한 융합 기술 연구 (Convergence Technique Study through Simulation Thermal Analysis due to the Shape of Electric Heater)

  • 이정호;조재웅
    • 한국융합학회논문지
    • /
    • 제6권6호
    • /
    • pp.241-246
    • /
    • 2015
  • 추운 겨울철 실내를 따뜻하게 해주는 발열 및 난방기구들은 필수적인 요소이며, 2000년대부터 이러한 난방기구들의 사용량은 급격하게 증가하고 있다. 하지만, 화재 사고와 화재의 위험성 역시 증가하고 있다. 따라서 본 연구에서는 보다 안전한 난방기구의 설계를 위하여 시중에서 판매되는 세라믹, 카본 및 근적외선 히터들로서의 세 가지 형상의 전기히터들을 참고하여 3D 모델링하였으며, 이들 모델들을 가지고 열 해석을 수행하여 열변형량과 열응력 등에 따른 내구성을 연구하였다. 본 연구에서 도출된 연구 결과들을 바탕으로 각 형상에 따른 전기히터 모델들의 내구성을 예측할 수 있었고, 궁극적으로 보다 안전한 내화성이 있는 새로운 난방기구의 개발에 기여할 수 있었다. 또한 디자인 면에서 융합 기술로의 접목도 가능하여 미적인 감각을 나타낼 수 있다.

119 구급 신고 분석: 대화 시간 및 내용을 중심으로 (An Analysis of 119 Emergency Calls: Focused on Conversation Time and Contents)

  • 장경호;강경희
    • 한국화재소방학회논문지
    • /
    • 제32권4호
    • /
    • pp.103-109
    • /
    • 2018
  • 119 종합상황실의 상황 요원은 화재, 구조, 구급 등의 위기 상황을 처음으로 인지하고 대응 체계를 가동시켜야 하는 중요한 역할을 수행하고 있다. 특히 119 구급 신고와 관련하여 상황 요원의 신속하고 정확한 수보 활동은 환자의 생명은 물론 예후를 결정할 수 있다. 이에 본 연구에서는 2014년 4월 8일부터 12월 31일의 ${\bigcirc}{\bigcirc}$시 신고 접수, 출동, 구급활동 자료를 이용해 상황 요원과 신고자의 대화 회전 수와 대화 시간, 그리고 대화 구조 및 순서의 시간 등을 접수 경로와 중증도에 따라 분석하였다. 상황 요원과 신고자의 대화 분석은 향후 상황관리단계에 따른 조치 사항 또는 행동 매뉴얼의 개발이나 개선에 활용할 수 있을 것으로 기대된다.

플랜트 사고 대응 훈련을 위한 탈출 및 조치 경로 설계 기법 개발 (Development of Escape and Rescue Path-taking Method for Plant Accident Response Training)

  • 김형진;박찬국;이재용;이춘식
    • 한국가스학회지
    • /
    • 제21권6호
    • /
    • pp.61-69
    • /
    • 2017
  • 플랜트 사고 발생 시 현장 운전원, 제어실 운전원 및 소방관 등이 취해야 할 가장 중요한 사항은 사고 현장으로부터의 탈출과 사고 현장으로의 사고 진압 처리를 위한 진입일 것이다. 이 두 가지 중요한 행동은 서로 상반된 방향으로 진행해야 하는 조치이며, 사고 대응 이동 경로에 대한 훈련을 평상시에 훈련함으로써, 사고의 확산을 방지하고 효율적인 사고 대응을 할 수 있다. 이와 같은 필요성에 의해 본 연구에서는 플랜트 사고 대응 훈련을 위한 탈출 및 조치 경로 설계 기법을 개발하였다. 활용 방안으로는, 운전원 및 소방관들의 사고 발생 시점의 플랜트 내 실시간 위치로부터 사고 탈출 및 조치 경로를 계산하여 플랜트 안전훈련시스템에 이동 경로 정보를 제공함으로써, 안전 훈련 시나리오에 적용하여 현실적이고 효과적인 훈련 효과를 제공할 수 있을 것으로 기대된다.

차동식스포트형열감지기 현장점검용 표준화기기 개발에 관한 연구 (A Study on the Development of Standardization Tester for the Field Inspection of the Rate of Rise Spot Type Heat Detector)

  • 김시국;육현대;양승현;지승욱;이춘하
    • 한국화재소방학회논문지
    • /
    • 제23권3호
    • /
    • pp.85-92
    • /
    • 2009
  • 본 논문은 차동식스포트형열감지기 현장점검용 표준화기기 개발에 관한 연구이다. 현재 소방점검 시 차동식스포트형열감지기의 성능확인을 위해 사용되는 점검기기(4 Type)들을 실험대상으로 선정하여 문제점을 찾고, 도출된 문제점을 바탕으로 차동식스포트형열감지기 형식승인 시 감도시험기준과 동일한 온도조건인 실온보다 $30^{\circ}C$ 높은 온도로 자동설정 할 수 있고 설정된 온도를 계속 유지할 수 있는 기능과 풍속 조건인 풍속 85cm/s를 유지할 수 있는 차동식스포트형열감지기 현장점검용 표준화기기의 회로를 설계하고 시제품을 제작하였다. 개발된 시제품의 성능확인 결과 차동식스포트형열감지기의 형식승인시험 시 감도시험조건과 동일한 성능이 나타나는 것을 확인하였다.

SEA-Pro를 이용한 어선실습선 한미르호의 피난 분석 (Analysis of evacuation for fishery training ship HANMIR using SEA-Pro)

  • 김원욱;김석재
    • 수산해양기술연구
    • /
    • 제57권3호
    • /
    • pp.228-235
    • /
    • 2021
  • Marine accidents caused by ships are very diverse, such as collision, sinking, stranding, grounding and fire. In particular, persons on passenger ship are unspecified and not trained, so it makes evacuation harder. For this reason, an evacuation plan that considers diverse situation in ship is needed. Effective evacuation planning requires training in consideration of various evacuation situations. In this paper, we investigated the time elapsed on evacuation in various situations from "HANMIR," the fishery training ship of the Korean Institute of Maritime and Fisheries Technology, using a Ship Evacuation Analysis Program (SEA-Pro) which is introduced to the society. We assumed a situation that has not only inconveniences for real training but also the possibilities of happening. Not all trainees are resting in their cabin, so we assumed positions such as they are in the bridge or engine room and applied fire and flooding situations. We assumed that the time for alerting the situation would be short, so we applied only elapsed time of movement. Those analyses could be helpful in three ways. The first is predicting the consequence of possible accidents. There are some conditions that can be appliable to this model, such as the decreased area of sight in those situations. The second is concluding the optimal limit of carriage and placement of safety instruments on building a new ship. The third is to be a base data for ships to make a new effective evacuation plan based on these analyses.