• Title/Summary/Keyword: Room acoustic

Search Result 253, Processing Time 0.03 seconds

Automation of electrical acoustic experimental apparatus for the directivity measurement of sound (소리의 지향성 측정을 위한 전기음향실험기기의 자동화)

  • Jarng, Soon-Suck;Ko, Jae-Ha
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.574-576
    • /
    • 2004
  • The directivity of the sound pressure increases the sensitivity of the incoming sound from specific directions. The directivity measurement of the sound pressure is usually done in an anechoic room using a sloping motor. In this paper a replaceable anechoic chamber was designed for the acoustic directivity pattern measurement. Electrical equipments were interfaced with a PC for experiment automatic control. Some comparative results are shown in the result.

  • PDF

Automatic control of experimental apparatus for sound's directivity measurement direction acoustic wave (소리의 방향성 측정을 위한 실험기기의 자동제어)

  • Jarang, Sun-Suck;Ko, Jae-Ha;Lee, Je-Hyeong
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.591-594
    • /
    • 2004
  • The directivity of the sound pressure increases the sensitivity of the incoming sound from specific directions. The directivity measurement of the sound pressure is usually done in an anechoic room using a steping motor. In this paper a replaceable anechoic chamber was designed for the acoustic directivity pattern measurement. Electrical equipments were interfaced with a PC for experiment automatic control. Some comparative results are shown in the result.

  • PDF

Optimum Design of High Voltage Fuse Holder with a Built-in Acoustic Absorber System (흡음장치를 내장한 고전압 퓨즈홀더의 최적설계에 관한 연구)

  • Jin, Yeung-Jun;Lee, Hae-Won;Hwang, Yu-Sub
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.1
    • /
    • pp.8-14
    • /
    • 2011
  • Noise and vibration are likely to disturb the sensory system of human body leading to psychological stress and thereby property damage. In this research, a cut out switch(COS) with a built-in acoustic absorber along with a COS fuse broken was developed to reduce percussion noise. This new system is based on a design approach that combines existing absorber systems: expansion type, resonator type, and acoustic absorber type silencer The noise performance of the new system was simulated using the $SYSNOISE^{TM}$ software under optimized parameters: the diameter of perforated plate 2 mm, the plate thickness 3 mm, the width of expansion room 25 mm, the impinging vortex room 14 mm, and the noise absorbtion room 10 mm. The results showed that it reduced noise by approximately 41.1 dB compared to the current systems available in the market. Furthermore, it showed reduced noise by approximately 12 dB more than a product with an acoustic absorber of the Fault Tamer(USA).

A Study on the Prediction of Building Equipment Noise Generates at Machine Room (기계실에서 발생하는 설비소음의 예측에 관한 연구)

  • You, Hee-Jong;Jung, Eun-Jung;Kim, Jae-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.6
    • /
    • pp.476-484
    • /
    • 2007
  • Recently, in accordance with the buildings are becoming to large-sizes, high-stories, the large scaled facilities and equipments in machine room are quite demanding, and the generated noise volume according to this situation is on increasing. Since such noise is becoming to the object of a serious civil appeal, it is the real situation that a reduction countermeasure against the machine room equipment noise is keenly necessitated. On such viewpoint, this study has recorded, measured the noises which were generated from each individual as same as the whole equipped machines and tools, on the object of the dormitory machine rooms of the 3 colleges that haying mutually different peculiarities, then after grasp-ing their characters and acoustic powers, this research has verified its prediction possibility and the authenticity by comparison the estimated numerical value with the actually measured numerical value through the acoustic simulation. After grasping the prediction possibility in such way, by utilization of the sound absorption material in the machinery room, from the stage of design, the soundproof measures for the noise reduction at machine room could be regulated effectively, and it is also considered that such data would be utilized as the fundamental material for an establishment of the measure for sound insulation.

Architectural Acoustics Design of multipurpose Auditorium in S-high school (S고등학교(高等學校) 다목적(多目的) 강당(講堂)의 건축음향설계(建築音響設計))

  • Ju, Duck-Hoon;Yun, Jae-Hyun;Kim, Jae-Soo
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2008.04a
    • /
    • pp.436-440
    • /
    • 2008
  • Among those various facilities attached to the school building, the Auditorium is being utilized for not only the Exercise Activity but also for many purposes such as Culture, Public Performance, Education, Assembly and so on. In order to utilize in maximum such function of the multipurpose auditorium, an adequate acoustic design with regard to the Clarity of Voice and Music in accordance with its use-purpose should be accompanied. However, as the most part of multipurpose auditoriums is designed with high ceiling-height by its peculiar character, and due to use of the material of strong reflexibility, it is appearing the defect that excessively exposes the reverberation of sound. In order to make out an optimal acoustic condition within the broad space such as an auditorium, the acoustic characteristics must be considered from the planning stage, however in the most case, those acoustic problems are being settled through the repair works after construction. On such viewpoint, this Study intends to analyze the room acoustic characteristics from the planning stage using a computer simulation based on the blueprint of multipurpose auditorium in S High School located in Gwangju. It is considered that the material analyzed in such way could be practically applied as a fundamental material enables to improve the acoustic capability when a similar broad space is planned hereafter.

  • PDF

Effects of the Complexity of 3D Modeling on the Acoustic Simulations and Auralized Sounds (3D 모델의 구체성이 건축음향 시뮬레이션 및 가청화시재에 미치는 영향)

  • Park, Chan-Jae;Haan, Chan-Hoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.30 no.1
    • /
    • pp.22-32
    • /
    • 2011
  • The present study examined the effects of the complexity of the 3D models on the results of acoustic simulation which is the predominant tool of the acoustical design of buildings. Also, the effects of the 3D model on the auralized sounds were investigated. In order to carry out the study, four 3D models with different levels of complexity were introduced for a real auditorium which have different numbers of surfaces in the persuit of the guidance of odeon room acoustic software. The set-up of models was also based on the level of transition order of the program. And the acoustic experiments were performed measuring room acoustic parameters including SPL, RT, C80, D50. Acoustic computer simulations were performed using four different models. Then, the results of the computer modeling were compared with the measured acoustical parameters. In addition, sound sources were recorded in the field and auralized sounds were made in convolution with the impulse source made from acoustic modeling. Then, subjective tests were undertaken using auralized sounds. As the results, it was found that the result of the acoustic simulation were closer to the real room acoustic properties when 3D model was more particularly made. For the subjective test, the listening materials were acknowledged as similar with the real sound source when more complex 3D model was used. Then, it could be concluded that the complexity of the 3D model affects the results of the acoustic modeling as well as subjective tests.

A Robust Stereophonic Acoustic Echo Canceler Using Delayless Subband Adaptive Filter

  • Lee, Won-Cheol
    • The Journal of the Acoustical Society of Korea
    • /
    • v.17 no.1E
    • /
    • pp.20-29
    • /
    • 1998
  • This paper proposes a new stereophonic acoustic echo canceler with deploying delayless subband adpative filters. Due to the storong correlation between stereo signals, a stereophonic acoustic echo canceler is suffering from the slow convergence and the misalignment for estimating impulse responses corresponding to true echo paths at receiving room. Specially, dual adaptive filters for echo cancellation are significantly affected by the abrupt change of the transmission room environment so that the impariments on voice communication could be experienced. To prevent these performance degradations, this paper proposes a robust subband echo canceler employing pre-processing block so as to enhance the convergence speed and provide the insusceptibility to the environment change at transmission room.

  • PDF

Development of shipboard large-sized low-noise room unit with multiple outlets (다수의 출구를 가진 선박용 대형 저소음 룸유닛 개발)

  • Kim, Sang-Ryul;Kim, Hyun-Sil;Lee, Sung-Hyun;Park, Geun-Hyo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.600-605
    • /
    • 2012
  • In this paper, the acoustic performance of a shipboard large-sized room unit is studied. The room unit is a kind of rectangular absorptive chamber with a partition whose surface absorptive material with fabric skin is attached to. The room unit has one inlet and three outlet. At the inlet, a plane damper is installed to control the flow rate. The acoustic performance of a prototype room unit is measured using a HVAC mock-up. It is shown that its insertion loss is comparable with that of a commercially-used room unit but the developed room unit generates flow noise higher than the other one. The major source of flow noise is analyzed by NADS-R, the noise analysis program for room unit. Cone-shaped dampers are proposed to be used as the damper of a room unit to reduce flow noise. It is shown that the cone-shaped damper decrease flow noise remarkably.

  • PDF

Development of Shipboard Large-sized Low-noise Room Unit with Multiple Outlets (다수의 출구를 가진 선박용 대형 저소음 룸유닛 개발)

  • Kim, Sang-Ryul;Kim, Hyun-Sil;Lee, Sung-Hyun;Park, Keun-Hyo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.5
    • /
    • pp.468-473
    • /
    • 2012
  • In this paper, the acoustic performance of a shipboard large-sized room unit is studied. The room unit is a kind of rectangular absorptive chamber with a partition whose surface absorptive material with fabric skin is attached to. The room unit has one inlet and three outlets. At the inlet, a plane damper is installed to control the flow rate. The acoustic performance of a prototype room unit is measured using a HVAC mock-up. It is shown that its insertion loss is comparable with that of a commercially-used room unit but the developed room unit generates flow noise higher than the other one. The major source of flow noise is analyzed by NADS-R, the noise analysis program for room unit. Cone-shaped dampers are proposed to be used as the damper of a room unit to reduce flow noise. It is shown that the cone-shaped damper decrease flow noise remarkably.

An Experimental Study on the Acoustic Characteristic of Korean Traditional Houses in Chonnam Province (전남 지방 전통주택의 음향특성에 관한 실험적 연구)

  • Lee, Tai-Gang;Kim, Hyung-Ryul;Kim, Hang;Choi, Eun-Suk;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.686-689
    • /
    • 2005
  • This study aims to analyzed the acoustics characteristics of Korean Traditional Houses in Chonnam Province varied with lay out and floor plane to reflect the way of control for environmental condition. These houses are surveyed the reverberation time and level difference between rooms of the main living room and other main floored room, master room and kitchen. As a result, the reverberation time of traditional rooms are below 0.6 second, and the sound insulation performance of Korean traditional door are mostly very low grade with D-15. The level difference between rooms are low grade not to meet minimum class except between main living room and master room away from main living building.

  • PDF