• Title/Summary/Keyword: Room Unit

Search Result 702, Processing Time 0.026 seconds

A Study on the Improving Speech Intelligibility of Emergency Broadcast Equipment in the Apartments (공동주택 내 비상방송설비의 음성명료도 실태 분석 및 재실자 인지성 개선방안 연구)

  • Oh, So-Young;Cho, Hyun-Min;Lee, Young-Ju;Lee, Min-Joo;Yoon, Myung-Oh
    • Fire Science and Engineering
    • /
    • v.32 no.4
    • /
    • pp.60-68
    • /
    • 2018
  • Due to the complicated plan structure of the apartment units and the improved room-to-room sound insulation performance, it is difficult to communicate and recognize the fire situation by emergency broadcast equipment. In this study, speech intelligibility was measured and analyzed for three types of apartment unit by emergency broadcast equipment on various measurement points. Simulations were also conducted to improve the speech intelligibility. As a result of field measurements 72, 84, and 101 Type were not satisfied with NFSC standard of 90 dBA at the point of 1 m distance from source. In addition, it was evaluated that 75 dBA and CIS 0.7 of NFPA standard was not satisfied at all measurement points except for the 72 Type at living room point with door opened condition. Based on the door opened condition of the bedroom, it satisfied the NFPA of 75 dBA and CIS 0.7 in each bedroom when more than 90 dBA was satisfied at the 1 m separation point provided in NFSC standard.

Clean Room Structure, Air Conditioning and Contamination Control Systems in the Semiconductor Fabrication Process (반도체 웨이퍼 제조공정 클린룸 구조, 공기조화 및 오염제어시스템)

  • Choi, Kwang-Min;Lee, Ji-Eun;Cho, Kwi-Young;Kim, Kwan-Sick;Cho, Soo-Hun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.25 no.2
    • /
    • pp.202-210
    • /
    • 2015
  • Objectives: The purpose of this study was to examine clean room(C/R) structure, air conditioning and contamination control systems and to provide basic information for identifying a correlation between the semiconductor work environment and workers' disease. Methods: This study was conducted at 200 mm and 300 mm semiconductor wafer fabrication facilities. The C/R structure and air conditioning method were investigated using basic engineering data from documentation for C/R construction. Furthermore, contamination parameters such as airborne particles, temperature, humidity, acids, ammonia, organic compounds, and vibration in the C/R were based on the International Technology Roadmap for Semiconductors(ITRS). The properties of contamination control systems and the current status of monitoring of various contaminants in the C/R were investigated. Results: 200 mm and 300 mm wafer fabrication facilities were divided into fab(C/R) and sub fab(Plenum), and fab, clean sub fab and facility sub fab, respectively. Fresh air(FA) is supplied in the plenum or clean sub fab by the outdoor air handling unit system which purifies outdoor air. FA supply or contaminated indoor air ventilation rates in the 200 mm and 300 mm wafer fabrication facilities are approximately 10-25%. Furthermore, semiconductor clean rooms strictly controlled airborne particles(${\leq}1,000{\sharp}/ft^3$), temperature($23{\pm}0.5^{\circ}C$), humidity($45{\pm}5%$), air velocity(0.4 m/s), air change(60-80 cycles/hr), vibration(${\leq}1cm/s^2$), and differential pressure(atmospheric pressure$+1.0-2.5mmH_2O$) through air handling and contamination control systems. In addition, acids, alkali and ozone are managed at less than internal criteria by chemical filters. Conclusions: Semiconductor clean rooms can be a pleasant environment for workers as well as semiconductor devices. However, based on the precautionary principle, it may be necessary to continuously improve semiconductor processes and the work environment.

Composting of Compostable Household Wastes in a Home Composter without Additives (소형 퇴비화용기에 의한 가정쓰레기의 무첨가 퇴비화)

  • Seo, Jeoung-Yoon;Lee, Geun-Sun;Choi, Hyoung-Sub
    • Korean Journal of Environmental Agriculture
    • /
    • v.17 no.2
    • /
    • pp.160-163
    • /
    • 1998
  • In this study, the compostable household wastes from a house were composted in a home composter without adding any bulking agent and microorganisms. Every day wastes of 1kg were added to the composter during the experimental period. The following results were obtained : 1. Each component of the compostable household wastes generated every day showed very difference. 2. While composting proceeded at room temperature by suppling 1,1322 l air per hour, the composting material maintained the water content of 74.36 ${\sim}$ 85.14%, whereas while composting proceeded at $45^{\circ}C$ by suppling 427 l air per hour, the compost had optimal water content. The electric power of 132kwh a month was required by operating the composting unit at $45^{\circ}C$. 3. During 20 day, decomposition of 28% at room temperature and 44% at $45^{\circ}C$ were obtained respectively. 4. The accumulation of inorganic compound contents were not shown during the composting period, However, the content of salt and Cd was very high. Therefore, using the compost for agriculture has to be careful. 5. The biofilter removed the odorous substants efficiently at the room temperature due to increasing surface loading.

  • PDF

A Methodology for Making Military Surveillance System to be Intelligent Applied by AI Model (AI모델을 적용한 군 경계체계 지능화 방안)

  • Changhee Han;Halim Ku;Pokki Park
    • Journal of Internet Computing and Services
    • /
    • v.24 no.4
    • /
    • pp.57-64
    • /
    • 2023
  • The ROK military faces a significant challenge in its vigilance mission due to demographic problems, particularly the current aging population and population cliff. This study demonstrates the crucial role of the 4th industrial revolution and its core artificial intelligence algorithm in maximizing work efficiency within the Command&Control room by mechanizing simple tasks. To achieve a fully developed military surveillance system, we have chosen multi-object tracking (MOT) technology as an essential artificial intelligence component, aligning with our goal of an intelligent and automated surveillance system. Additionally, we have prioritized data visualization and user interface to ensure system accessibility and efficiency. These complementary elements come together to form a cohesive software application. The CCTV video data for this study was collected from the CCTV cameras installed at the 1st and 2nd main gates of the 00 unit, with the cooperation by Command&Control room. Experimental results indicate that an intelligent and automated surveillance system enables the delivery of more information to the operators in the room. However, it is important to acknowledge the limitations of the developed software system in this study. By highlighting these limitations, we can present the future direction for the development of military surveillance systems.

DEVELOPMENT OF INVERTER AND POWER CAPACITORS FOR MILD HYBRID VEHICLE (MHV) - TOYOTA "CROWN"

  • Shida, Y.;Kanda, M.;Ohta, K.;Furuta, S.;Ishii, J.
    • International Journal of Automotive Technology
    • /
    • v.4 no.1
    • /
    • pp.41-45
    • /
    • 2003
  • The 42V Mild Hybrid System has been released into market by Toyota for the first time in the world in 2001. The set-up employs an inverter unit to control the motor/generator (MG) electronically. The driving system called such as Toyota Mild Hybrid System (TMHS) has additional new functions to conventional internal combustion engines. When stopping vehicle, the engine stops promptly. When starting vehicle, by releasing the brake pedal MG starts the vehicle at the same time (EV-driving mode). When stepping on the accelerator pedal, or after a given period of time the engine firing occurs and the engine-driving mode starts. When running by motor, the power is supplied to the motor from 36V battery through the inverter. High outputs and instant responses are required for Inverter. At the same time, the compact volume is required to fit into the limited space of the engine room. The compact size and high output are also required to Power Capacitor used for this inverter. The power capacitors has been newly developed, shaped in "flat" type, suitably for the inverter. The points of developments on inverter and power capacitor are described in this paper.his paper.

UV Sensitivity of Korean Skin and The Effects of Factors affecting SPF Determination (한국인 피부의 자외선 감수성과 SPF 측정치에 미치는 인자의 영향)

  • 이병곤
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.17 no.1
    • /
    • pp.1-17
    • /
    • 1991
  • Multiport-600 Solar SimulatorR is one of the most recent and convenient in-strument for evaluation of sun protection factor(SPF). In this study, we examined the practicability of the SPF determining system using Multiport -600 and the effects of several factors-light sources, seasons and experimental animals-on the minimal erythema dose(MED) and SPF. We also tested the UV sensitivity according to the sites of Korean people, And the ultraviolet radiation reaching the earth's surface In Seoul have been observed for one year. As a result of this study, the determinig system for SPF using Multiport-600 was proved to be a good system in accuracy and time-saving. The biological activity of fluorescence UV lamp of PUVA-800R was significantly higher than natural light or solar simulator with Xe arc lamp, and the determined MED became lower in inverse proportion to room temperature rise. Skin sensitivity by ultraviolet adiation was hights. in order \circled1 back \circled2 inns, upper arm \circled3 outer upper arm \circled4 foream. We also observed that UV radiation intensity was highest at noon in july and 1 sun burn unit(MED) was 28 minutes at that time.

  • PDF

Analysis on Living Factor and Actual State of Indoor Thermal Environment in Apartment Units during Winter (아파트의 겨울철 실내온열환경 실태와 생활요인 분석)

  • Choi, Yoon-Jung;Jeong, Youn-Hong
    • Journal of the Korean housing association
    • /
    • v.19 no.4
    • /
    • pp.97-105
    • /
    • 2008
  • The purposes of this study were to determine the actual state of the indoor thermal environment in apartment units and to analyze the relationship between the living factors and indoor thermal elements. The field surveys consisted of measurements of physical elements and observations of living factors. In addition, the residents of 20 apartment units were interviewed to survey their subjective response. Field surveys were carried out from January to March 2007. Measuring elements were air temperature, globe temperature, and relative humidity. The results showed that the average of indoor temperature for the houses was $21.2{\sim}27.2^{\circ}C$, while 4 houses exceeded the comfort zone. The average of globe temperature for the houses was $21.3{\sim}27.5^{\circ}C$, while 6 houses exceeded the comfort zone. The mean relative humidity was $19.5{\sim}58.8%$, which is a relatively dry condition. The residents' average clothing value was $0.39{\sim}0.89$ clo(average 0.68 clo). The average thermal sensation vote on each room was $4.2{\sim}4.8$, which is 'neutral' to 'slightly warm'. Living factors had significant effect on indoor temperature in regression analysis were ventilation time(outdoor air exchange), opening time of door through balcony, and gas cooker use time.

A Treatment Case of Delayed Aortic Injury: The Patient with Posterior Rib Fracture

  • Park, Hyun-Seok;Ryu, Se-Min;Cho, Seong-Joon;Park, Sung-Min;Lim, Sun-Hye
    • Journal of Chest Surgery
    • /
    • v.47 no.4
    • /
    • pp.406-408
    • /
    • 2014
  • A 66-year-old male patient arrived at the emergency room with a crush injury to his chest. Multiple rib fractures, hemothorax on both sides, left scapular fracture, liver laceration, and retroperitoneal hematoma were found upon the radiologic examination. After closed thoracostomy, the patient had been initially admitted to the intensive care unit, but he was transferred to the general ward on the next day. On the 4th post-trauma day, the patient complained of severe pain and there was bloody drainage through the chest tube. This case is an exploration with the consideration of the possibility of major bleeding and the subsequent repair of the descending thoracic aorta. This case is regarded as a case in which the aorta wall was damaged as the sharp margin of the fractured ribs caused continuous irritation.

A Study of Developing Wear Tester to Measure and Minimize Particle Levels in Cleanroom (장비 구동부품 기인 Particle 평가를 위한 마모측정기의 개발에 관한 연구)

  • Park, Kwang Hee;Noh, Kwonhak;Chang, Sung Ho;Lee, Jonghwan;Cha, Young Cheul;Chun, Hae Dong
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.36 no.2
    • /
    • pp.1-7
    • /
    • 2013
  • Cleanroom could be largely classified into industrial cleanroom that can be contaminated by particles and bio-cleanroom that can be contaminated by biological particles. Electrical manufacturing companies producing precision machines and electrical parts essentially have industrial cloom facilities and clean technologies to produce defects free products due to particles. Industrial cleanroom should be controlled in respect of 4M1E to prevent from foreign materials of sub-micro unit and to keep out contamination sources from outside. In this paper, a concept for a quantitative methodology to measure the particles from running components was suggested by combining both newly making clean booth such as wear tester and laser particle counter.

A Study on the Analytical Technique for the Actual Conditions of Fundamental Facility for Education in University Campus - Focused on the Case of C University Campus in Gyeongbuk - (대학 캠퍼스 교육기본시설 운용실태 분석기법에 관한 연구 - 경북 소재 C대학의 사례를 중심으로 -)

  • Kim, Chi-Hwan
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.9 no.1
    • /
    • pp.41-51
    • /
    • 2010
  • It is high level of management activity for the fixed property of building to operating spaces for education in university campus. Therefore, this study is focused on definition of the factors for analyzing the actual conditions of space operation and application of them to C university campus in Gyeongbuk in the aspect of infrastructure of university and efficiency of space operation. These analytical factors are the rate of lecture and experimentation room, the rate of theoretical and experimental subject in curriculum and unit area for infrastructure and the rate of use, turnover rate and occupation rate per lecture for space operation. If the analytical factors of space operation are systemized as program module for space operation, the space management system of university campus will be characterized on the foundation of university information system. And it will be able to support the decision making about space management. It needs to integrate various type of information and data of university to increase the efficiency of decision making.