• Title/Summary/Keyword: Room Constant

Search Result 632, Processing Time 0.029 seconds

Physical Properties of $Ba_{1-x}Sr_x(Mg{1/3}Nb_{2/3})O_3$Ceramics ($Ba_{1-x}Sr_x(Mg{1/3}Nb_{2/3})O_3$ 세라믹스의 물리적 특성)

  • 김부근;김재윤;김강언;정수태;조상희
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.325-328
    • /
    • 1999
  • The physical and electrical properties of $\textrm{Ba}_1$ $_{x}\textrm{Sr}_{x}$($\textrm{Mg_{1/3}Nb_{2/3}}$)$\textrm{O}_3$ (x =0, 0.2, 0.4, 0.6, 0.8, 1.0) ceramics were investigated. The Bal $_{x}\textrm{Sr}_{x}$($\textrm{Mg_{1/3}Nb_{2/3}}$)$\textrm{O}_3$ systems were shown that the hexagonally ordered superlattices were increased with increasing x values. The relative densities of all samples were over 97% theoretical densities. The dc resistivities of samples were $10^{13}$ - $10^{14}$$\Omega\textrm{cm}$at room temperature, these values were nearly constant at 130(x=0)-$230^{\circ}C$ (x=l). However, the resistivities of samples decreased rapidly above those temperature and their activation energies were from 1.0 to 1.52 eV. The relative dielectric constant was 33(BMN) and 30.6(SMN) respectively. And the highest value was shown at x=0.4 and the value was 34.3. The temperature coefficient of dielectric constant was -61 ppm/$^{\circ}C$(BMN) and 79 ppm/$^{\circ}C$ (SMN) respectively.

  • PDF

Actual operation characteristics to evaluate the performance of heat pump outdoor unit in the constant temperature chamber (항온챔버에서 히트펌프 실외기의 성능을 평가하는 실제 운전)

  • Jong-Ryeol Kim
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.23 no.3
    • /
    • pp.123-128
    • /
    • 2022
  • A lot of research is being done to develop a high-efficiency heat pump to save energy, and research to reduce or eliminate the phenomenon of frost occurring in the outdoor unit coil is also being conducted at the same time. In order to conduct a study that does not cause frost on the outdoor unit of the heat pump regardless of the season, a constant temperature chamber like a general room that can be tested under the same conditions as in the natural state was built. The experiment was conducted by providing an environment similar to the natural state to the outdoor unit of the heat pump installed in the constant temperature chamber. As a result, the lower the outdoor temperature, the lower the efficiency of the heat pump. It wat confirmed that the lower the value, the longer it is.

A Study on the Room Temperature Properties of Domestic Molding Sand depending on the Variations of Sand Grain Distribution and Grain Shape. (국산주물사(國産鑄物砂)의 입도분포(粒度分布)와 입형(粒形)에 따른 상온성질(常溫性質)에 관(關)한 연구(硏究))

  • Kang, Min-Jeon;Lee, Kye-Wan
    • Journal of Korea Foundry Society
    • /
    • v.4 no.1
    • /
    • pp.5-11
    • /
    • 1984
  • Green compressive strength, permeability, deformation, flowability, compactability and green hardness values at room temperature are dependable on the grain distribution and grain shape. The results obtained under constant moisture (4% for sand) and bentonite (8% for sand) were as follows; 1. With decreasing grain size, surface area of sand grain was increased. 2. With decreasing grain size, coefficient of angularity was increased. 3. As surface area increased from $8926.43cm^2$ to $21211.16cm^2$ , green compressive strength was increased from $210.93\;g/cm^2$ to $449.98\;g/cm^2$, hardness was increased from 76.7 to 82.3, but permeability was decreased from $411.7\;{\frac{\;cc\;{\cdot}\;cm\;}{atm\;{\cdot}\;cm^2\;{\cdot}\;min.}}$ to $113.7\;{\frac{\;cc\;{\cdot}\;mm\;}{atm\;{\cdot}\;cm^2\;{\cdot}\;min.}}$ 4. As surface area increased from $8926.43\;cm^2$ to $21211.16\;cm^2$, flowability was decreased from 82.3% to 80.8%, deformation was decreased from $67.1\;cm\;{\times}\;10^{-3}$ to $54.6\;cm\;{\times}\;10^{-3}$, but compactability was increased from 44.8% to 54.3%. 5. Room temperature properties of molding sand were affected by variation of surface area.

  • PDF

Deformation Properties of TiC-Mo Eutectic Composite at High Temperature (TiC-Mo 공정복합재료의 고온 변형특성)

  • Shin, Soon-Gi
    • Korean Journal of Materials Research
    • /
    • v.23 no.10
    • /
    • pp.568-573
    • /
    • 2013
  • The deformation properties of a TiC-Mo eutectic composite were investigated in a compression test at temperatures ranging from room temperature to 2053 K and at strain rates ranging from $3.9{\times}10^{-5}s^{-1}$ to $4.9{\times}10^{-3}s^{-1}$. It was found that this material shows excellent high-temperature strength as well as appreciable room-temperature toughness, suggesting that the material is a good candidate for high-temperature application as a structure material. At a low-temperature, high strength is observed. The deformation behavior is different among the three temperature ranges tested here, i.e., low, intermediate and high. At an intermediate temperature, no yield drop occurs, and from the beginning the work hardening level is high. At a high temperature, a yield drop occurs again, after which deformation proceeds with nearly constant stress. The temperature- and yield-stress-dependence of the strain is the strongest in this case among the three temperature ranges. The observed high-temperature deformation behavior suggests that the excellent high-temperature strength is due to the constraining of the deformation in the Mo phase by the thin TiC components, which is considerably stronger than bulk TiC. It is also concluded that the appreciable room-temperature toughness is ascribed to the frequent branching of crack paths as well as to the plastic deformation of the Mo phase.

Theoretical Review and Experiment on Applicability of Double Skin Facade Ventilated by Fans (팬을 부착한 이중외피의 이론적 검토 및 적용성에 대한 실험 연구)

  • Lim, Ji-Hye;Sohn, Jang-Yeul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.9
    • /
    • pp.605-613
    • /
    • 2010
  • Double skin facade(DSF) ventilated by fans consists of a normal external and an internal envelope. In this glass layer, the installed fan replaces an air inlet for the control of air flow through the cavity. The purpose of this paper is to investigate physical theory and to analyze the applicability of fans installed in a DSF. The experiment was conducted in 2 rooms. One room has a DSF with installed fans and the other one has a typical window. The room ventilated through a DSF which fans are installed was always kept warmer than the other room, ventilated directly from the outdoors. The average increase of the supplied air temperature through the DSF ventilated by fans was $6.54^{\circ}C$ at 78CMH, $6.2^{\circ}C$ at 95CMH, and $3.7^{\circ}C$ at 120CMH. As a result, the DSF with installed fans was appropriate for installation in rooms. It supplies outdoor fresh air heated through a cavity and ventilates a constant air volume.

Hall Effect and Resistivity of Amorphous $Fe_{83-x}Zr_{7}B_{10}Nb_{x}$ Alloys

  • Lee, Soo-Hyung;Yu, Seong-Cho;Xu, Jun-Hau;Rao, K.V.;Noh, Tae-Hwan;Kang, Il-Koo;Rhie, Kungwon
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.5
    • /
    • pp.841-845
    • /
    • 1995
  • The effect of small addition of Nb on the electrical resistivity and Hall coeffcient of the amorphous $Fe_{83}Zr_{7}B_{10}$ alloy and annealed ones ones below the crystallization temperature were investigated, which has been considered to be suitable for high frequency core material. At room temperature, their resistivities $\rho$ and the spontaneous Hall coeffcients $R_{s}$ are $~1.6\;{\mu}{\Omega}m$ and $~3{\times}10^{-8}m^{3}/As$, respectively. $R_{s}$ and $\rho$ are decreased with increasing temperature from 100 K to room temperature. Side-jump effect was adopted to analyze the effect of the small variation of conentration and annealing. The quantity of $R_{s}/{\rho}^{2}$ at room temperature, which is directly related to the electronic structure of the mother alloy, remained almost a constant except as quenched one as it can be predicted from the side-jump effect. The unexpected temperature dependence of $R_{s}/{\rho}^{2}$ measured at low fields much below Tc is left as a question.

  • PDF

HALL EFFECT AND RESISTIVITY OF AMORPHOUS $Fe_{83-x}Zr_{7}B_{10}Nb_{x}$ ALLOYS

  • Lee, Soo-Hyung;Yu, Seong-Cho;Xu, Jun-Hau;Rao, K.V.;Noh, Tae-Hwan;Kang, Il-Koo;Rhie, Kungwon
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.5
    • /
    • pp.772-777
    • /
    • 1995
  • The effect of small addition of Nb on the electrical resistivity and Hall coefficient of the amorphous $Fe_{83}Zr_{7}B_{10}$ alloy and annealed ones below the crystallization temperature were investigated, which has been considered to be suitable for high frequency core material. At room temperature, their resistivities $\rho$ and the spontaneous Hall coefficients $R_{s}$ are $~1.6\;{\mu}{\Omega}m$ and $~3{\times}10^{-8}m^{3}/As$, respectively. $R_{s}$ and $\rho$ are decreased with increasing temperature from 100 K to room temperature. Side-jump effect was adopted to analyze the effect of the small variation of concentration and annealing. The quantity of $R_{s}/{\rho}^{2}$ at room temperature, which is directly related to the electronic structure of the mother alloy, remained almost a constant except as quenched one as it can be predicted from the side-jump effect. We suggested the temperature dependence of $R_{s}/{\rho}^{2}$ can be compared to Ms{T}.

  • PDF

Production of SCC Flaws and Evaluation Leak Behavior of Steam Generator Tubes (누설 및 파열실험용 SCC 결함 전열관 제작 및 누설거동 평가)

  • Hwang, Seong-Sik;Jung, Man-Kyo;Park, Jang-Yul;Kim, Hong-Pyo
    • Corrosion Science and Technology
    • /
    • v.8 no.5
    • /
    • pp.188-192
    • /
    • 2009
  • A forced outage due to a steam generator tube leak in a Korean nuclear power plant was reported.1) Primary water stress corrosion cracking has occurred in many tubes in the plant, and they were repaired using sleeves or plugs. In order to develop proper repair criteria, it is necessary to understand the leak behavior of the tubes containing stress corrosion cracks. Stress corrosion cracks were developed in 0.1 M sodium tetrathionate solution at room temperature. Steam generator(SG) tubes with short cracks were successfully fabricated with a restricted solution contact method. The leak rates of the degraded tubes were measured at room temperature. Some tubes with 100 % through wall cracks showed an increase of leak rate with time at a constant pressure.

Numerical and Experimental Analyses Examining Ozone and Limonene Distributions in Test Chamber with Various Turbulent Flow Fields

  • ITO, Kazuhide
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.16 no.3
    • /
    • pp.89-99
    • /
    • 2008
  • Indoor ozone has received attention because of its well-documented adverse effects on health. In addition to the inherently harmful effects of ozone, it can also initiate a series of reactions that generate potentially irritating oxidation products, including free radicals, aldehydes, organic acids and secondary organic aerosols (SOA). Especially, ozone reacts actively with terpene. The overarching goal of this work was to better understand ozone and terpene distributions within rooms. Towards this end, the paper has two parts. The first describes the development of a cylindrical test chamber that can be used to obtain the second order rate constant $(k_b)$ for the bi-molecular chemical reaction of ozone and terpene in the air phase. The second consists of model room experiments coupled with Computational Fluid Dynamics (CFD) analysis of the experimental scenarios to obtain ozone and terpene distributions in various turbulent flow fields. The results of CFD predictions were in reasonable agreement with the experimental measurements.

A Study on the Formations of Thermal Stratification of Furniture Fire (가구화재시 열적성층의 형성에 관한 연구)

  • 허만성
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.24-29
    • /
    • 1996
  • The objective of this research is to study on the formations of thermal stratification in a room in case of several furniture fires such as trashcan, chair, carpet, sofa, mattress and wardrobe as a fire starter in a residential room by performing the experimental studies. The uniformly distributed fire in case of carpet showed that the ignition and the initial growth period were relatively short while the fully developed period was considerably long. The concentrated fires such as the mattress and wardrobe showed that the ignitions and the initial growth periods were relatively long. When fire spread to only one direction, like the case for the trashcan with a regular shape, there was one peak of temperature profile, and for the irregular shaped furniture such as chair, sofa, mattress and wardrobe, there were two or more peaks. The interface heights for the furniture fires were around 1(m) mataining constant state. However, at the time of the maximum temperature, the interface height was lowered to 0.25(m)-0.75(m) from the floor

  • PDF